| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Agreement Executed |
Tender Value
₹1.2 Cr
EMD Value
₹50,000
Closing Date
11 Dec 2024, 2:00 pmClosed
The Superintending Engineer, KWA, PH Circle, Thiru
Office of the Superintending Engineer, KWA, PH Circle, Thiruvalla, Pathanamthitta
DEPOSIT WORK- Manneera- Peruvali Water Supply scheme Construction of 6m dia- Intake Well cum pump House G L Sump, Booster Pump Houses, Pressure Filter and distribution Net Works with Over Head Tank at Thalamanam- etc.
2024_KWA_696758_1
25/2024-25/KWA/ PHC/TVLA (Rt-2)
Open Tender
Civil Works - Water Works
Item Rate
365 days
Thannithodu
As per NIT conditions and submitted Tender Documents
5 documents required · 5 mandatory
₹6,508
₹50,000
22 May 2025
15 Oct 2024
12 Dec 2024
15 Oct 2024
11 Dec 2024
15 Oct 2024
15 Oct 2024 - 11 Dec 2024
Amount
Design and Construction of 6.00 m dia. Intake well cum Pump House at Thattathikkayam Area of Kallar
OD279140/2023-2024:Charges for design and preparation of Good For Construction (GFC) drawings (both structural architectural) through an accredited Structural Engineer/Govt. Accredited Agency after conducting Soil Investigation at Well site (Soil investigation including mobilization of equipment boring taking samples, conducting tests and providing report with analysis and recommendation for foundation/structure). The charges include the vetting charges for M/s WASCON/Reputed Engineering College faculty, submission of 3 set of minimum A3 size Drawings , soft copy of drawing in AUTOCAD , Soil investigation charge and including any other design consultation charges complete as per direction of Departmental Engineer - In - Charge of the work
2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
100.3.6.11:Earthwork in open well excavation (in or under water) for wells of diameter above 3.5m and up to 6.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
100.3.6.12:Earthwork in open well excavation (in or under water) for wells of diameter above 3.5m and up to 6.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift from 1.5m to 3.0m including neat banking.
100.4.8:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 4.5m (3.0m to4.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
100.4.9:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 6.0m (4.5m to 6.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD277163/2023-2024:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 7.5m (6m to 7.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD277164/2023-2024:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 9m (7.5m to 9.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD277165/2023-2024:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 10.5m (9m to 10.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.52.S.1:Sub Data for providing Earth filled cement bags including cutting of the Earth, filling, conveying and placing in position.
100.52.S.2:Sub Data for Filling with contractor's own earth (excluding rock) in the core portion of the earthen bund by consolidating each deposited layer by ramming and watering, as per direction of the departmental officers.
100.52.S.4:Sub Data for Conveying and providing bamboo poles for reinforcing the temporary bund including the cost materials and labour charges etc. complete.
100.52.S.5:Sub Data for Dismantling the sand / earth filled cement bag from the foundation site of bund, apron on both sides, counter wall and removing the sand/earth from the bag and disposing the damaged cement bags properly as per the direction of the department officers including all cost of labour charges etc complete.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
9.97.1:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
13.71:Lettering with black Japan pint of approved brand and manufacture
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
OD277166/2023-2024: Supplying 300 mm ID ,HDPE pipe end and 32mm thick MS flange conveying within initial lead ,inserting the MS flange to pipe end and jointing Sub End at end of the pipe at 2000c using welding jack and welding mirror capable to withstand a pressure of 16Kg/cm2 including all labour and hire for appliances and equipments,cost of all specials, electric energy charges etc complete as per direction.
OD277167/2023-2024:Casting RCC sleeves for fixing 300 mm ID HDPE pipe spaced at 100cm C/C as per design with C:C 1:11/2:3 using 20mm nominal size broken stone and supplying suitable size anticorrosive 25mm dia, 40cm long - T bolts and nuts 8Nos/Each, 4 nos 25 mm pvc ,15 cm long pipe bit (for inserting the sleeve for bolt hole) including hire charges for form work, watering ,curing etc but excluding cost of cement etc complete as per direction.
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
100.98.475:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 300mm.
OD277169/2023-2024:Providing toilet facilities (such as two number tap fittings, one number 200 liter capacity synthetic water tank ,necessary pipe laying for connecting water line and sewerage systems) for operators
OD277170/2023-2024:Supplying and fixing septic tank of 500 litres and all other specials required for interconnection of tank with W/C.(White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps,Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid’,Providing and fixing soil, waste and vent pipes:,Supply of PVC Tap,<br>) etc Required earth work excavation for fixing the tank under earth of required slope and level site complete as per direction of dept officers
OD279146/2023-2024:Supplying and fixing 300 mm DI D/F wall casting pipe including specials as per Direction of dept officers
100.10.11:Laying HDPE pipes (IS : 4984) on land portion including conveying within initial lead and aligning the pipes, electro-fusion welding using automatic or semi-automatic electrofusion machines, testing the pipeline thus fabricated to suit the hydraulic working pressure and after testing, aligning the pipeline, lowering the pipe in position into the trenches already made, testing the line to suitable pressure with potable water before back filling and levelling the trenches including all labour charge, hire for appliances etc., complete but excluding cost of pipe and fittings: 315mm Nominal Outside Diameter Pipes.
100.98.144:Supply of HDPE Pipe PE 100 (IS 4984/1995), 8kg, 315mm Outer Dia.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.10:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock Requiring Blasting.
100.1.11:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 3m but not exceeding 4.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m in Hard Rock Requiring Blasting.
Bidder Name
Anil Kumar
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1086536.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .