Vadodara Division (Pratapnagar): Electrical works in connection with construction of new DRM Office building and other infrastructure.
BRC-EL-P-24-26-27~WR
BRC-EL-P-24-26-27
Open
Works - General
12 Months
Vadodara, Gujarat
₹0
₹3.9 L
23 Sept 2026
23 Sept 2026
8 Oct 2026
125 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | Below/Par | ||
| — | — | — | 1,78,84,996 | ||
| — | 30.00 | — | — | ||
| Providing smart aluminium track - The price shall cover for supply, fixing, testing and commissioning of Smart Aluminium track of PHILIPS/WIPRO/CROMPTON/BAJAJ make. The track shall be of Aluminium structure with fool-proof design to avoid reverse connecting. The track shall have three wires (one phase) with enhanced earth connecting function. The track shall be powder painted in Black/Grey/White colour and shall be supplied in lengths of 1 meter or 2 meters to suit site requirement. The price shall also cover for supply, fixing, testing and commissioning of joints for Aluminium track. The joints shall have three wires (one phase) with enhanced earth connecting function. The joints shall be powder painted in Black/ Grey/White colour and shall be supplied as straight, Tee shaped or angular shaped to suit site requirement. The tracks and joints shall be CQC certified. | — | — | — | 63,000 | |
| — | 43.00 | — | — | ||
| Providing spot/track LED light fitting, 20 Watt - The price shall cover for supply, fixing, testing and commissioning of track/recess mounted spot light for sculptures/artifacts/murals of PHILIPS/ WIPRO/CROMPTON/BAJAJ make. The luminaries shall have compact and aesthetic design and excellent thermal management. Specifications are as under -Lumen - 2000 Lumen, Power - 20 Watt, System Efficacy - 100 Lumen/Watt, Standard Deviation Colour Matching - <5, CCT - 3000° to 4000° K, CRI - 80 and Beam Angle - 24° | — | — | — | 3,22,500 | |
| — | 300.00 | — | — | ||
| Supply and providing three-core flexible Copper wire, 24/0.2 mm conforming to IS: 694, 1100 Volt grade for connection to LED fittings - The price shall cover for supply and connection of three-core, flexible copper wire of size 24/0.20 mm, ISI marked, PVC insulated, conforming to IS: 694, 1100 Volt grade from the existing overhead line/catenary/junction box to LED street light fitting as per site conditions. The connection cord shall be protected by suitable size of heavy duty flexible PVC conduit. | — | — | — | 9,300 | |
| — | 1500.00 | — | — | ||
| Supply of copper cable, single-core 10.0 sq mm - The price shall cover for supply of XLPE sheathed and insulated, LTUG cable, single-core, 10.0 sq. mm, stranded Copper conductor, 1100 Volt grade conforming to IS: 7098 Part I (latest), ISI marked. A copy of test certificate shall be submitted along with the cable. | — | — | — | 2,23,500 | |
| — | 500.00 | — | — | ||
| Supply of copper cable, four-core 6.0 sq mm - The price shall cover for supply of XLPE sheathed and insulated, LTUG cable, four-core, 6.0 sq. mm, stranded Copper conductor, 1100 Volt grade conforming to IS: 7098 Part I (latest), ISI marked. A copy of test certificate shall be submitted along with the cable. | — | — | — | 3,04,500 | |
| — | 1500.00 | — | — | ||
| Supply of copper cable, four-core 10.0 sq mm - The price shall cover for supply of XLPE sheathed and insulated, LTUG cable, four-core, 10.0 sq. mm, stranded Copper conductor, 1100 Volt grade conforming to IS: 7098 Part I (latest), ISI marked of. A copy of test certificate shall be submitted along with the cable. | — | — | — | 14,25,000 | |
| — | 40.00 | — | — | ||
| Supply, installation, testing and commissioning of RCBO, two-pole, 40 Amp with outdoor type MS enclosure - The price shall cover for supply, fixing, testing and commissioning of RCBO, two-pole, 40 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. | — | — | — | 1,10,360 | |
| — | 20.00 | — | — | ||
| Supply, installation, testing and commissioning of RCBO, four-pole, 40 Amp with outdoor type MS enclosure - The price shall cover for supply, fixing, testing and commissioning of RCB0, four-pole, 40 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. | — | — | — | 64,980 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of RCBO, four-pole, 63 Amp with outdoor type MS enclosure - The price shall cover for supply, fixing, testing and commissioning of RCBO, four-pole, 63 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. | — | — | — | 36,210 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of RCBO, four-pole, 100 Amp with outdoor type MS enclosure - The price shall cover for supply, fixing, testing and commissioning of RCBO, four-pole, 100 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. | — | — | — | 65,420 | |
| — | 1.00 | — | — | ||
| Providing lighting control board with MCB DP, 32 Amp - 1 No, Time Switch, 16 Amp - 1 No and Single Phase Contactor, 32 Amp - 1 No - The price shall cover for supply, fixing, testing and commissioning of lighting control board fabricated from CRCA sheet steel, powder coated with grey finish, dust and vermin proof, water resistant with metallic door complete with MCBs of 10 KA breaking capacity. The board shall be equipped with incomer MCB TPN, 10 KA breaking capacity, 32 Amp rating - 1 No, Time switch, 16 Amp - 1 No, Single-phase contactor of rating 32 Amp - 1 No. The board shall be completely wired with multi-stranded copper wire of suitable capacity and shall be provided with heavy duty connectors of suitable capacity for termination of incoming and outgoing wires and shall be provided with two nos of earthing terminals on each side of the board and riveted metallic caution board in three languages. | — | — | — | 4,850 | |
| — | 5.00 | — | — | ||
| Providing lighting control board with MCB DP 32 Amp - 2 Nos, Time Switch, 16 Amp - 2 Nos and Single Phase Contactor, 32 Amp - 2 Nos - The price shall cover for supply, fixing, testing and commissioning of lighting control board fabricated from CRCA sheet steel, powder coated with grey finish, dust and vermin proof, water resistant with metallic door complete with MCBs of 10 KA breaking capacity. The board shall be equipped with incomer MCB DP, 10 KA breaking capacity, 32 Amp rating - 2 Nos, Time Switch, 16 Amp - 2 Nos, Single-phase contactor of rating 32 Amp - 2 Nos. The board shall be completely wired with multi-stranded copper wire of suitable capacity and shall be provided with heavy duty connectors of suitable capacity for termination of incoming and outgoing wires and shall be provided with two nos of earthing terminals on each side of the board and riveted metallic caution board in three languages. | — | — | — | 26,095 | |
| — | 10.00 | — | — | ||
| Providing Distribution Board, double-door, with incomer MCCB, four-pole, 63 Amp - 1 No and outgoing MCB DP, 20/32 Amp - 10 Nos - The price shall cover for fabrication, supply, fixing, testing and commissioning of pre-fabricated Distribution Board fabricated from 18 SWG CRCA sheet steel, powder coated with grey enamel, double door, wall/floor mounted, dust and vermin proof, water resistant, confirming to relevant IS and complete with MCCBs and MCBs. The Distribution Board shall be suitable for surface/concealed mounting. The board shall fabricated for three-phase, four-wire, 440 Volt AC, 50 Hz supply system and shall consist of the following switchgears/ accessories - (a) Incomer - MCCB, four-pole, 63 Amp, with thermal-magnetic release range 50 - 63 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection. The MCCB shall be supplied with spreader terminals and rotary handle --- 1 No (b) Outgoing -MCB DP, 10 KA breaking capacity, 20/32 Amp ---- 10 Nos (c) Bus bar for main circuit and neutral shall have uniform cross section and made from electrolytic tinned copper as per relevant standards with colour coded, heat shrinkable, PVC insulated and having current density of 1.6 Amp/sq. mm cross sectional area --- 1 set (d) Multi LED type indication lamp for three-phases --- 1 Set (e) Cable glands of required sizes --- LOT (f) Two earth terminals of 12 mm diameter G.I. nut/bolt with washers shall be provided in the LT panel and all sheet steel section shall be electrically connected with a separate G.I. earth strip of 50 x 6 mm size across the panel at bottom. (g) Metallic Caution Board in three languages riveted to the panel board --- 2 Nos | — | — | — | 1,99,370 | |
| — | 30.00 | — | — | ||
| Providing Distribution Board, double-door with incomer MCB TPN, 63 Amp - 1 No, RCBO, four-pole, 63 Amp - 1 Nos and outgoing MCB TPN, 32 Amp - 3 Nos and MCB DP, 32 Amp - 6 Nos - The price shall cover for supply, fixing, testing and commissioning of pre-fabricated, double door, MCB distribution board fabricated from CRCA sheet steel, powder coated with grey finish, dust and vermin proof, water resistant with metallic door complete with MCBs of 10 KA breaking capacity. The Distribution Board shall be suitable for surface/concealed mounting. The Distribution Board shall be equipped with incomer MCB TPN, 63 Amp - 1 No, RCBO, four-pole, 30 mA sensitivity, 63 Amp - 1 No and outgoing MCB TPN, 32 Amp - 3 Nos and MCB DP, 32 Amp - 6 Nos. The board shall be completely wired with multi-stranded copper wire of suitable capacity and shall be provided with heavy duty connectors of suitable capacity for termination of incoming and outgoing wires and shall be provided with two nos of earthing terminals on each side of the board and riveted metallic caution board in three languages. | — | — | — | 9,00,510 | |
| — | 2.00 | — | — | ||
| Providing Distribution Board with incomer MCCB, four-pole, 125 Amp - 1 No and outgoing MCB TPN, 63 Amp - 3 Nos and MCB DP, 25/32 Amp - 9 Nos - The price shall cover for fabrication, supply, fixing, testing and commissioning of pre-fabricated Distribution Board fabricated from 18 SWG CRCA sheet steel, powder coated with grey enamel, double door, wall/floor mounted, dust and vermin proof, water resistant, outdoor type confirming to relevant IS and complete with MCCBs and MCBs. The Distribution Board shall be suitable for surface/concealed mounting. The board shall be fabricated for three-phase, four-wire, 440 Volt AC, 50 Hz supply system and shall consist of the following switchgears/accessories - (a) Incomer - MCCB, four-pole, 125 Amp, with thermal-magnetic release range 100 - 125 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection. The MCCB shall be supplied with spreader terminals and rotary handle --- 1 No (b) Outgoing -MCB TPN, 10 KA breaking capacity, 63 Amp ---- 3 NosMCB DP, 10 KA breaking capacity, 25/32 Amp ---- 9 Nos (c) Bus bar for main circuit and neutral shall have uniform cross section and made from electrolytic tinned copper as per relevant standards with colour coded, heat shrinkable, PVC insulated and having current density of 1.6 Amp/sq. mm cross sectional area --- 1 set (d) Multi LED type indication lamp for three-phases (Red, Yellow and Blue) with protection fuses --- 1 Set (e) Cable glands of required sizes --- LOT (f) Two earth terminals of 12 mm diameter G.I. nut/bolt with washers shall be provided in the LT panel and all sheet steel section shall be electrically connected with a separate G.I. earth strip of 50 x 6 mm size across the panel at bottom. (g) Metallic Caution Board in three languages riveted to the panel board --- 2 Nos | — | — | — | 76,882 | |
| — | 1.00 | — | — | ||
| Providing outdoor type fountain pump panel with MCB TPN, 63 Amp - 1 No, MCB DP, 16 Amp - 4 Nos, DOL starter suitable for 1.0 HP pump, fountain lighting controller for three circuits and suitable connectors - The price shall cover for fabrication, supply, fixing, testing and commissioning of outdoor type fountain pump panel fabricated from 18 SWG CRCA sheet steel, powder coated with grey enamel, double door, wall/floor mounted, dust and vermin proof, water resistant, outdoor type confirming to relevant IS and complete with MCCBs and MCBs. The board shall be fabricated for three-phase, four-wire, 440 Volt AC, 50 Hz supply system and shall consist of the following switchgears/ accessories - (a) MCB TPN, 10 KA breaking capacity, 63 Amp ---- 1 No (b) MCB DP, 10 KA breaking capacity, 16 Amp ---- 4 Nos (c) Direct-On-Line starter operating on 415 Volt, three-phase, AC supply suitable for fountain pump up to 5.0 HP capacity with relay range of 9 to 15 Amp ---- 1 No (d) Cable glands and heavy-duty connectors of required sizes --- LOT (e) Earthing terminals ---- 2 Nos (f) Metallic Caution Board in three languages riveted to the panel board --- 2 Nos | — | — | — | 41,620 | |
| — | 8.00 | — | — | ||
| Providing Distribution Board with incomer MCCB, four-pole, 125 Amp - 1 No and outgoing MCB TPN, 63 Amp - 12 Nos - The price shall cover for fabrication, supply, fixing, testing and commissioning of pre-fabricated Distribution Board fabricated from 18 SWG CRCA sheet steel, powder coated with grey enamel, double door, wall/floor mounted, dust and vermin proof, water resistant, outdoor type confirming to relevant IS and complete with MCCBs and MCBs. The Distribution Board shall be suitable for surface/concealed mounting. The board shall be fabricated for three-phase, four-wire, 440 Volt AC, 50 Hz supply system and shall consist of the following switchgears/accessories - (a) Incomer - MCCB, four-pole, 125 Amp, with thermal-magnetic release range 100 - 125 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection. The MCCB shall be supplied with spreader terminals and rotary handle --- 1 No (b) Outgoing -MCB TPN, 10 KA breaking capacity, 63 Amp ---- 12 Nos (c) Bus bar for main circuit and neutral shall have uniform cross section and made from electrolytic tinned copper as per relevant standards with colour coded, heat shrinkable, PVC insulated and having current density of 1.6 Amp/sq. mm cross sectional area --- 1 set (d) Multi LED type indication lamp for three-phases (Red, Yellow and Blue) with protection fuses --- 1 Set (e) Cable glands of required sizes --- LOT (f) Two earth terminals of 12 mm diameter G.I. nut/bolt with washers shall be provided in the LT panel and all sheet steel section shall be electrically connected with a separate G.I. earth strip of 50 x 6 mm size across the panel at bottom. (g) Metallic Caution Board in three languages riveted to the panel board --- 2 Nos | — | — | — | 5,42,056 | |
| — | 1.00 | — | — | ||
| Providing Distribution Board with incomer MCCB, four-pole, 125 Amp - 1 No and outgoing MCB TPN, 63 Amp - 12 Nos with time switch - 2 Nos and contactor - 2 Nos - The price shall cover for fabrication, supply, fixing, testing and commissioning of pre-fabricated Distribution Board fabricated from 18 SWG CRCA sheet steel, powder coated with grey enamel, double door, wall/floor mounted, dust and vermin proof, water resistant, outdoor type confirming to relevant IS and complete with MCCBs and MCBs. The Distribution Board shall be suitable for surface/concealed mounting. The board shall be fabricated for three-phase, four-wire, 440 Volt AC, 50 Hz supply system and shall consist of the following switchgears/ accessories - (a) Incomer - MCCB, four-pole, 125 Amp, with thermal-magnetic release range 100 - 125 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947- 2 with adjustable overload and short circuit settings and inbuilt instantaneous protection. The MCCB shall be supplied with spreader terminals and rotary handle --- 1 No (b) Outgoing -MCB TPN, 10 KA breaking capacity, 63 Amp ---- 12 Nos (c) Time switch, 16 Amp and Single phase contactor of rating 32 Amp --- 2 sets (d) Bus bar for main circuit and neutral shall have uniform cross section and made from electrolytic tinned copper as per relevant standards with colour coded, heat shrinkable, PVC insulated and having current density of 1.6 Amp/sq. mm cross sectional area --- 1 set (e) Multi LED type indication lamp for three-phases (Red, Yellow and Blue) of L&T/Schneider/Siemens/ C&S/ABB/BCH make with protection fuses --- 1 Set (f) Cable glands of required sizes --- LOT (g) Two earth terminals of 12 mm diameter G.I. nut/bolt with washers shall be provided in the LT panel and all sheet steel section shall be electrically connected with a separate G.I. earth strip of 50 x 6 mm size across the panel at bottom. (h) Metallic Caution Board in three languages riveted to the panel board --- 2 Nos | — | — | — | 76,937 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of 200 KVAR Automatic Power Factor Correction capacitor panel - The price shall cover for supply, fixing, testing and commissioning of Intelligent Automatic Power Factor Correction (APFC) capacitor panel suitable for 433 Volt AC, 50 Hz, three- phase, four-wire system, floor mounted with base channel made up of 16 SWG CRCA sheets steel, all bolted construction with PU gasket suitable for indoor installation, dust and vermin proof with detachable cable gland plates at the bottom for cable entry, totally compartmentalized with separate compartments for capacitors, with seven-tank process of surface treatment and powder coating with Siemens grey shade and 3.0 mm mounting plate with IP:55 degree of protection incorporating, with auto and manual switching option for individual capacitors. Scope of work includes design, manufacturing, supply, installation, testing and commissioning of APFC Panel of 200 kVAR capacity in seven-step, 40 stages as per the specifications given in Annexure-XXI of tender document. | — | — | — | 1,50,407 | |
| — | 3.00 | — | — | ||
| Providing Distribution Panel, double-door, outdoor type, wall/floor mounted with incomer MCCB, four-pole, 200 Amp - 2 Nos, On-Load Change Over Switch, four-pole, 200 Amp - 1 No and outgoing MCCB, four-pole, 125 Amp - 2 Nos and MCCB, four-pole, 63 Amp - 4 Nos with multifunctional meter, indication lamps, earthing terminal etc - The price shall cover for design, supply, installation, testing and commissioning L.T. distribution board fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design. The LT panel shall be indoor/outdoor, rectangular cubicle type, dust and vermin proof suitable for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 6,54,297 | |
| — | 2.00 | — | — | ||
| Providing outdoor type, double-door, wall/floor mounted, Distribution Panel with incomer MCCB, four-pole, 250 Amp - 2 Nos and outgoing MCCB, four-pole, 125 Amp - 8 Nos with multifunctional meter, indication lamps, earthing terminal etc - The price shall cover for design, supply, installation, testing and commissioning L.T. distribution board fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor, rectangular cubicle type, dust and vermin proof suitable for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 4,38,318 | |
| — | 1.00 | — | — | ||
| Providing Distribution Panel, double-door, outdoor type, wall/floor mounted with incomer MCCB, four-pole, 400 Amp - 1 No and outgoing MCCB, four-pole, 200 Amp - 4 Nos and MCCB, four-pole, 125 Amp - 4 Nos with multifunctional meter, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. distribution board fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design. The LT panel shall be indoor/outdoor, rectangular cubicle type, dust and vermin proof suitable for three-phase, four- wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 2,25,295 | |
| — | 3.00 | — | — | ||
| Providing Distribution Panel with incomer MCCB, four-pole, 250 Amp - 2 Nos, On-load Change Over Switch, four-pole, 250 Amp - 1 No and outgoing MCCB, four-pole, 125 amp - 4 Nos, MCCB, four-pole, 63 Amp - 2 Nos with multifunctional meter, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. distribution board fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design. The LT panel shall be indoor/outdoor, rectangular cubicle type, dust and vermin proof suitable for three-phase, four- wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 7,19,706 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of outdoor type, double-door, Distribution Panel with incomer MCCB, four-pole, 200 Amp - 2 Nos and outgoing MCCB, four-pole, 125 Amp - 4 Nos, MCCB, four-pole, 63 Amp - 4 Nos with multifunctional meter, indication lamps, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. distribution board fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design. The LT panel shall be indoor/outdoor, rectangular cubicle type, dust and vermin proof suitable for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 2,48,101 | |
| — | 1.00 | — | — | ||
| Providing HT Panel Board (one incomer and three outgoing) for 11 KV, 800 Amp, 26.2 KA/sec indoor type VCB panel (horizontal drawer and horizontal isolation type) with all protection relays, CTs, PTs, meters etc. - The price shall cover for supply, fixing, testing and commissioning of 11 KV, 500 MVA, 800 Amp, 26.2 KA/second rating one incoming and three outgoing VCB, indoor type, Metal clad horizontal isolation, horizontal draw out type with 230 Volt AC motor operated mechanism with manual operating mechanism suitable for installation in three-phase, three-wire effectively earthed system which should as per sub clause 5.3 of IEC Publication 694 as detailed in IS: 13118/1991 and should be suitable for indoor installation. Mounting of VCB in panel should be rack in and rack out type as per IS: 13118. The design, construction and rating of the VCB should be as per relevant ISS. Each VCB panel (i.e. incoming and outgoing) shall also have arrangement for tripping and indication and alarm arrangement with Buchholz relay, OTI and WTI of transformer. Note - The enclosure of VCB shall be such that all manual operation for operating VCB can be done after closing the doors of VCB to ensure safety of operating personnel. All the spring charging, metering and indication supply to be given from individual PT of each VCB panel. Technical Specifications of HT Panel are given in Annexure-XXI of tender document. HT Panel shall consist of four Nos of 11 KV, 800 Amp, three-phase, 26.2 KA, VCB. | — | — | — | 12,73,838 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Main Distribution Panel with incomer Air Circuit Breaker, EDO type, microprocessor based, four-pole, 800 Amp - 2 Nos and outgoing MCCB, four-pole, 630 Amp - 4 Nos with multifunctional meter, indication lamps, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning of Main Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design. The LT panel shall be indoor, rectangular-cubicle type, dust and vermin proof suitable for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 14,76,036 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Distribution Transformer, 500 KVA, 11000/433 Volt, three-phase complete with all accessories and foundation - The price shall cover for supply of 500 KVA, 11000/433 Volt, three-phase, Power Transformer including installation and commissioning. Technical Specifications of Distribution Transformer, 500 KVA are given in Annexure-XXI of tender document. | — | — | — | 9,25,453 | |
| — | 5.00 | — | — | ||
| Providing online UPS, 2.0 KVA cap with 120 minutes backup - Supply, fixing, testing and commissioning of Online UPS, 2.0 KVA capacity with isolation transformer and 120 minutes backup complete with all accessories, IGBT PWM based system suitable for single phase, 230 Volt 50 Hz AC input and single phase 230 Volt, sine wave, 50 Hz AC output, floor mounting type with indicative backup time of 120 minutes with minimum 6400 VAH, SMF VRLA batteries.Specifications are as under -Capacity - 2 KVAInput Voltage - 160 - 260 Volt, Single-phase, 50 Hz ACPF - Minimum 0.9 at full loadOverall efficiency - 90% at Rated LoadOverload capacity - Deliver a minimum overload at 125% for 10 minutes and 150% for 30 seconds.Operating temperature - 0 to 40 deg CTotal harmonic distortion - Maximum 3% for linear loads and 5% for Non linear loadsCrest factor - 3.1Noise level - Maximum 55 dbBattery - SMF type battery, 42 AH, 12 Volt - 8 NosWarranty - Minimum five (5) years for UPS and two (2) years for batteries | — | — | — | 4,50,965 | |
| — | 703.00 | — | — | ||
| Digging of cable trench 450/600 mm wide and 900 mm deep in all types of soil including hard, rocky etc. - The price shall cover for digging of 450/600 mm wide and 900 mm deep trench in all types of soil including soft, rocky as per cable route plan and filling back the trench after laying of cables. This also includes clearing of roots of trees and bushes and other temporary obstructions on the selected route. | — | — | — | 88,578 | |
| — | 50.00 | — | — | ||
| Digging of cable trench 100 mm wide and 200 mm deep in concrete/tar road/platform and refilling to its original position after laying of cable in 50 mm diameter HDPE pipe - The price shall cover for digging of cable trench of size 100 x 200 mm deep in concrete/tar road/platform surface and its refilling/plastering after laying of cable in 50 mm diameter HDPE pipe in existing trench. Supply and laying of HDPE pipe, 50 mm diameter is included in the scope of work. | — | — | — | 20,300 | |
| — | 2230.00 | — | — | ||
| Supply and laying of DWC pipe, 120 mm diameter - The price shall cover for supply of Double Wall Corrugated (DWC) HDPE pipe of 120 mm diameter. DWC HDPE pipe shall have corrugation on outer wall but inner wall shall be plain conforming to IS: 14930 Part I and II amended from time to time. The pipes shall be "ISI" marked. Accessories like HDPE snap fit coupler with neoprene 'O' ring shall be part of supply to make the joints water/damp proof. The strength and stiffness class of the pipe shall be SN4 and SN8 respectively.The price shall also cover for laying the DWC pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast. In case of any hard/stony soil, contractor should adopt new technology method in push through method. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 3,70,180 | |
| — | 1020.00 | — | — | ||
| Supply and laying of HDPE pipe, 110 mm diameter by pushing method under track/road - The price shall cover for supply of HDPE (High Density Polyethylene) pipe of 110 mm nominal diameter as per IS 4984-1995 with accessories required for laying such as coupler, bend etc. as per specifications given in Annexure-XXI of tender document. The price shall also cover for laying the HDPE pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast/road. In case of any hard/ stony soil, contractor should adopt new technology method in push through method by machine boring. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 14,55,540 | |
| — | 300.00 | — | — | ||
| Supply and erection of G.I. perforated cable tray of size 150 x 100 x 100 mm on MS frame with cover - The price shall cover for fabrication, supply and fixing of M.S. perforated cable tray, hot dip galvanized as per latest ISS/BSS of size 150 x 100 x 100 mm and 2.0 mm approximate thickness with appropriate cover of thickness 1.6 mm. The cable tray shall be fixed horizontally or vertically at site and the existing LT cables shall be laid/shifted in the cable tray by disconnecting from the panel/switch end and reconnecting as per site requirement duly tied with suitable clamps with GI nuts, bolts and washers in a safe and secure manner. The fixing clamps shall be fabricated from 50 x 50 x 6 mm MS angle or 50 x 6 mm MS flat duly painted and fixed at approximate distance of 1.5 to 2.0 meter apart with 2" long dowel/fisher rack bolts. The tray shall be fabricated in lengths of 2.0 m and couplers shall be provided at joints. The cable tray cover shall be fixed with GI screws. | — | — | — | 2,55,600 | |
| — | 20.00 | — | — | ||
| Providing uPVC pipe, 50 mm diameter - The price shall cover for supply of uPVC pipe of 50 mm nominal bore diameter and working pressure of 14 kg/sq. cm along with coupling, elbow, tee etc for protection of cable. The upright cable shall be encased in uPVC pipes for mechanical protection. The pipe shall be clamped with flat MS clamp at each location on upright cable length. uPVC Pipe shall be as per ASTM-D:1785.The price shall also cover for laying the uPVC pipes in ground/road and under the track by digging open trench method. Each length of the pipes shall be joined together using proper size of uPVC coupler and properly aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 3,540 | |
| — | 1150.00 | — | — | ||
| Supply and fixing of PVC maxi trunking of size 100 x 50 mm - The price shall cover for supply, fixing, testing and commissioning of ISI marked PVC Maxi Trunking of size 100 x 50 mm with all accessories. The PVC Maxi trunking shall be fixed at site by fabricated clamp of 18 SWG GI sheet at a distance not more than 1.5 meters by machine screw/GI nut bolts, washers etc. The existing power cables shall be laid in the PVC Maxi trunking properly dressed and secured by means of suitable clamps/fasteners etc. | — | — | — | 5,56,600 | |
| — | 3230.00 | — | — | ||
| Laying of cable in trench - The price shall cover for laying, testing and commissioning of LTUG armoured cable in existing trench/pipe and its connection at both ends. The cable shall be tested with 500 Volt Megger earth tester before laying it in the trench. The cable cores shall be tested for continuity, absence of cross phasing, Insulation Resistance between conductors to earth/armour and between conductors. The results should be recorded in presence of railways' representative. A composite cable layout plan on ferro-print or computerized print duly laminated in A-4 size should be submitted by the contractor to this office as well as site in-charge after laying of cable. Cables shall be supplied by railways at site engineer's stores. | — | — | — | 67,830 | |
| — | 1050.00 | — | — | ||
| Laying of cable on wall/cover shed/existing tray with MS clamp - The price shall cover for laying, testing and commissioning of LTUG armoured cable on wall/cover shed/in existing tray and its connection at both ends. The cable shall be tested with 500 Volt Megger before laying it in the tray. The cable cores shall be tested for continuity, absence of cross phasing, Insulation Resistance between conductors to earth/armour and between conductors. The results should be recorded in presence of railways' representative. A composite cable layout plan on ferro-print or computerized print duly laminated in A-4 size should be submitted by the contractor to site engineer and Divisional Office after laying of cable. | — | — | — | 33,600 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of 5.0 meter height G.I. street light octagonal pole, double arm complete with all accessories and foundation - The price shall cover for supply, erection and commissioning of 5.0-meter height double arm, G.I. Street light octagonal pole as per the specifications given in Annexure-XXI of tender document. | — | — | — | 3,09,300 | |
| — | 10.00 | — | — | ||
| Providing decorative pole 3.0/3.5 meter height for facade lighting complete with foundation etc - The price shall cover for supply of Mild Steel Decorative Pole of 3.0/3.5 meter length with cast aluminium mounting ring at top. The pole shall be conical in design with a round cross-section. The diameter shall be approximately 70 mm at bottom and 50 mm at top. The thickness of pole shall be 1.5 mm. The pole shall be supplied with a mounting base (suitable for grouting) of thickness 6.0 mm and 130 mm diameter. The mounting base shall be provided with four nos of mounting holes. Holes of suitable diameter with rubber grommet for cable entry shall be provided at top and bottom of the pole.The price shall also cover for erection of the pole, including digging of pole pit of suitable depth and casting of foundation with cement, sand and metal in the ratio of 1:3:6. The foundation shall be of 250 mm diameter of suitable depth and 300 mm height above ground level. The pole foundation top surface above ground level shall have a smooth finish and straight alignment. All items such as cement, sand, metal, foundation bolts, nuts etc. required for execution of this item shall be arranged by the contractor.The price shall also cover for supply, fixing, testing and commissioning of pole mounted junction of SMC model No. GSJB-3020 of SINTEX or similar make for terminating the incoming and outgoing cables and connecting wire of street lights. Junction box shall be complete with suitable connectors and fuse unit for streetlight. Complete unit shall be mounted on the pole by means of suitable hardware, terminal strips, cable glands, clamps etc.After erection of the pole in truly vertical position, it shall be painted with two coats of red oxide paint and one coat of enamel paint as per the colour decided by Railways. Enamel paint shall be of make Asian/Nerolac/ Berger. The coping/foundation above the ground level shall be white washed. | — | — | — | 1,60,000 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing and commissioning of 100 Watt LED flood light fixture with dedicated lens optic asymmetric distribution for facade elevation - The price shall cover for supply of 100 Watt Universal, sixteen colour changing LED Flood Light luminary with lens and mounting bracket for outdoor purpose, IP: 66 rating. The luminary shall be of aluminium body suitable for operation on 230 Volt, 50 Hz AC supply.The luminary shall have 16 colour options with dimmable feature and shall be provided with the remote controller for selecting the colour and adjusting brightness as desired. The luminary shall have flash, strobe, fade and smooth modes. The flash mode shall change colours every one second and the strobe mode shall change colours every three seconds. The fade and smooth mode shall provide colour gradient lights. The luminary shall have excellent heat dissipation, wide beam angle of 120 degree. Flexible metal bracket on the lamp body, allowing installing the light flexibly, including ceiling mounted, wall mounted, and ground mounted. The lamp body shall be adjustable to 150. The remote controller should easily change colours, brightness or modes with a press of the button. The luminary shall be of OSRAM/SURYA/SYSKA/OREVA/ WIPRO make.The price shall also cover for fixing, testing and commissioning of the luminary on existing M.S. Pole. The connection to the luminary shall be carried out through ISI marked, PVC insulated, flexible, three-core copper wire of size 24/0.20 mm from junction box as per site conditions. | — | — | — | 2,06,850 | |
| — | 200.00 | — | — | ||
| Providing illuminated glow signage board made from panaflex and vinyl sheet material with backlit LED module lighting - The price shall cover for fabrication, supply, fixing, testing and commissioning of LED backlit signage board as per detail specification as under -The LED Glow Sign Board of required size with suitable depth shall be visible from both sides. The board shall be well supported and the structure should be prepared to bear wind pressure and also self weight. Before manufacturing, the structural design should be got approved from site engineer. The board shall be fabricated from 18 SWG G.I. sheet. The vinyl sheet of size 0.5 mm thickness fully stretched shall be fixed between M.S. square section and from the top it should be supported by S.S. angle of size 25 x 25 mm fixed by machine screw. The vinyl sheet material shall be got approved from site engineer. The vinyl sheet should be illuminated from inside by LED strip/module of clear cool white color, 6500° CCT, 5.00 mm diameter LEDs of uniform intensity and luminosity for excellent and uniform visibility. The intensity of the illumination shall be such that it shall be possible to read the information clearly from a distance of 25 meters approximately. LED modules shall be supplied with electronic starter/driver. The board shall be provided with a heavy duty connector strip of bakelite material of 16 Amp capacity fitted on the board. All power supply units shall be of Switch Mode Power Supply type (SMPS) suitable for operation from AC sources ranging from 80 to 270 Volt, 50 Hz AC, single phase. All power units shall be tested at 50% load of maximum working capacity. The LED system wattage should be 6 Watt (max) per square feet and lux level shall be 1700 (±10%) Lux at 2 feet distance inside the surface. Provision shall also be made for 01 No. earth terminal and suitable numbers of louvers on both sides shall be provided for proper heat dissipation. A wire mesh shall also be provided to prevent entry of lizards and other insects. The matter, size of letter and language of signage board to be digitally printed on the vinyl sheet shall be given by the concerned site engineer. The board shall be fixed/hanged using a suitable size of clamp made from GI flat not less than 25 x 4 mm in the platform cover shed/offices/service buildings as per site requirement and connection shall be given through a three core PVC insulated copper flexible cable of size 24/0.20 mm protected by 19 mm diameter heavy duty PVC flexible conduit. | — | — | — | 1,72,400 | |
| — | 2.00 | — | — | ||
| Providing LED based "INDIAN RAILWAYS" logo board in Hindi and English languages of size 8 feet x 6 feet - The price shall cover for providing LED illuminated Glow Signage Logo Board. The scope of work involves design, fabrication, installation, testing and commissioning of LED illuminated Logo of INDIAN RAILWAYS and WESTERN RAILWAYS in Hindi and English as per the following specifications -The size of board shall be 8 feet x 6 feet. The board shall read as "INDIAN RAILWAYS" in Hindi and English on the periphery of the logo. The logo board shall be of box type fabricated from G.I. sheet of 22 SWG with a opening of suitable size with water tight gaskets at a suitable location for maintenance and connection purpose. The size of letter i.e. width and height shall be proportionate to the size of board size and the letters and stars shall be illuminated by providing super flux LED of low heat with extra bright light. One module of three LEDs shall be taken for every 9 square inch (approximately). The power LEDs shall be duly fixed in cups by silica gel or fusing gum. The LEDs shall be of Osram/Philips/GE/Lumiled/Wipro/Lednium make. The LEDs are to be glued with base of the acrylic letters along with wiring of appropriate size of flexible copper wire. The wiring has to be carefully done so as to avoid fusing. The LED module should be electrically connected with proper polarity. The SMPS, drivers and controllers for colour LED module shall be of suitable capacity and quantity and shall be provided in a weather and vermin proof box with efficient ventilation and heat dissipation. The input voltage to the drivers shall be 230 Volt, 50 Hz AC and the output voltage shall be 24 Volt DC. The SMPS are installed to regulate the voltage and wattage of the complete circuit. The SMPS input voltage shall be in the range of 190 to 260 Volt, 50 Hz, AC and the output voltage shall be 9 to 24 Volt at Wattage of 48 to 150 Watt. This shall be designed as per the site requirement. All the letters and seventeen Stars shall be fixed on ACP sheet and the entire sheet shall be supported on a suitable size of MS angle frame from the backside to withstand the maximum wind pressure or as advised by site-in-charge. The logo shall be digitally printed using high quality vinyl sheet of 2 mm thickness or unbreakable polycarbonate sheet and shall be illuminated with LED tube lights of suitable rating and quantity to have uniform brightness. The LED Logo Sign Board shall be connected to electric supply in a proper manner and one Time Switch of daily dial type and Single- Phase Contactor shall be provided to operate the board automatically. The Time Switch and the Single-Phase Contactor shall be fixed in a waterproof MS box provided with hinged door and pad locking arrangement. The box and M.S. angle frame structure shall be painted with two coats of red oxide primer and enamel paint of reputed make. The LED Logo Sign Board shall be fixed a suitable location on M.S angle frame of size 40 x 40 x 5 mm with requisite hardware to withstand gusty winds and storm. Before manufacturing of supporting structure the drawing shall be approved from the site supervisor. The entire structure shall be earthed properly. The colour code of LEDs, Letters and Stars shall be as per latest Railway Board norms. The Logo Board shall be provided at top of the building. | — | — | — | 2,28,336 | |
| — | 400.00 | — | — | ||
| Design, manufacture, display, installation of wall/hanging/floor mounting type signage/directional boards in flat/half elliptical/ Parabolic/Triangular shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2.0 mm thickness. The text/graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed/router cut on monomeric calendared vinyl of 70 um thickness and shall be firmly pasted on display sheets/Retro Reflective Boards. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement to be provided by the contractor with their own materials, labour, all Tools & Plants, lead, lift, transportation etc including all applicable taxes. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The scope of work covers Divisional Railway Manager's Office, Pratapnagar, Vadodara. Technical Specifications for Elliptical/Parabolic/Flat Signage Boards are given in Annexure-XXI of tender document. The work shall be carried out as per the "Guidelines on Standard Signages at Stations on Indian Railways, 2023" issued by the Ministry of Railways, Government of India. The work shall be executed strictly as per the specifications given in the document which is attached as Annexure. Colour scheme, font sizes, directional arrows, materials, fabrication, text, pictogram shall be as given in the document. | — | — | — | 8,75,600 | |
| — | 50.00 | — | — | ||
| Supply and laying of HTUG, XLPE cable, three-core, 120 sq mm - The price shall cover for supply of XLPE insulated and PVC sheathed cable, three-core, 120 sq mm, Aluminium conductor, screened, armoured, shielded cable conforming to IS: 7098 (Part -II) (amended up to date) for 11 KV earthed system. The cable shall be supplied at the site of work. A copy of the manufacturer's Test Certificate and authorized dealer's invoice shall be submitted along with the cable. The cable shall be tested with a 5.0 KV Megger before and after laying and the values to be recorded jointly with site engineer. | — | — | — | 64,350 | |
| — | 800.00 | — | — | ||
| Supply and laying of HTUG, XLPE cable, three-core, 95 sq mm - The price shall cover for supply of XLPE insulated and PVC sheathed cable, three-core, 95 sq mm, Aluminium conductor, screened, armoured, shielded cable conforming to IS: 7098 (Part -II) (amended up to date) for 11 KV earthed system. The cable shall be supplied at the site of work. A copy of the manufacturer's Test Certificate and authorized dealer's invoice shall be submitted along with the cable. The cable shall be tested with a 5.0 KV Megger before and after laying and the values to be recorded jointly with site engineer. | — | — | — | 12,81,600 | |
| — | 8.00 | — | — | ||
| Supply, fixing, testing and commissioning of indoor type, heat shrinkable, cable end termination kit for three-core, 11 KV, 120 sq mm XLPE HT cable - The price shall cover for supply, jointing, testing and commissioning of 11 KV indoor type heat shrinkable cable end box for 11 KV, three-core, 120 sq. mm XLPE cable. The individual cores of the cables shall be properly identified to avoid cross connections of the core while connecting them to the corresponding phases. The contractor shall engage skilled cable jointer for making the end termination and it should be provided only in presence of Railways' representative after taking proper shut down. Proper size of cable gland and lugs shall be provided for termination of cable. The cable shall be tested with a 5.0 KV Megger before and after laying and the values to be recorded jointly with site engineer. | — | — | — | 93,216 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of outdoor type, heat shrinkable, cable end termination kit for three-core, 11 KV, 120 sq mm XLPE HT cable - The price shall cover for supply, jointing, testing and commissioning of 11 KV outdoor type heat shrinkable cable end box for 11 KV, three- core, 120 sq. mm XLPE cable. The individual cores of the cables shall be properly identified to avoid cross connections of the core while connecting them to the corresponding phases. The contractor shall engage skilled cable jointer for making the end termination and it should be provided only in presence of Railways' representative after taking proper shut down. Proper size of cable gland and lugs shall be provided for termination of cable. The cable shall be tested with a 5.0 KV Megger before and after preparation of joint and the values to be recorded jointly with site engineer. | — | — | — | 19,052 | |
| — | 4.00 | — | — | ||
| — | 10.00 | — | — | ||
| — | 200.00 | — | — | ||
| Providing G.I. Earth wire, 8 SWG in PVC sleeve along with cable - The price shall cover for supply and laying of soft G.I. wire of 8 SWG covered with black coloured PVC sleeve of superior quality and laid along with PVC LTUG cable properly fixed and connecting earthing terminals of each panel. | — | — | — | 4,400 | |
| — | 550.00 | — | — | ||
| Providing PVC insulated and sheathed, single core, multi-stranded, Aluminium conductor cable, 10.0 sq. mm - The price shall cover for supply of single core, PVC insulated and sheathed, stranded, Aluminium conductor of 10 sq. mm cross sectional area conforming to IS 1554 - Part-1. The cable shall be flame retardant, should not support combustion and shall be self-extinguishing.The price shall also cover for laying of the cable for earth continuity from different points as advised by site engineer. | — | — | — | 13,200 | |
| — | 400.00 | — | — | ||
| Providing GI earthing strip of size 25 x 4 mm in PVC sleeve - The price shall cover for supply and laying of G.I. earthing strip of 25 x 4 mm size covered with black coloured PVC sleeve of superior quality from earth pit to control/distribution panel board. The earthing strip when laid on wall shall be fixed by means of suitable size of GI clamps and screws. | — | — | — | 32,400 | |
| — | 34.00 | — | — | ||
| Providing maintenance free earthing - The price shall cover for providing maintenance free earthing as per the following specifications - 1. High tensile-low carbon steel rod having diameter not less than 17 mm complying with requirements of BS 4360 Grade 43A or EN10025:2-004 S275JR, molecularly bonded by 99.99% pure high conductivity copper on outer surface with copper coating thickness of 250 micron or more, Length 3000 mm (minimum). Certificates from NABL approved labs shall be submitted with test results. 2. Copper earth bus-bar of size 250 mm x 50 mm x 6 mm having electrical conductivity of 101% IACS, minimum 99.9% copper content shall be exothermically welded to rod with 4 holes of 12 mm diameter (two on each side) for connecting earthing conductor. 3. Earth Enhancement compound should have characteristics as mentioned in the RDSO specifications. It should have low resistivity preferably below 0.2 Ohm-meter, supplied in sealed bags (minimum 75 kg per pit for 5' x 5' x 10' size pit and minimum 50 kg per pit for 300 mm bore type pit. The bags shall be marked with manufacturer's name or trade name, quality, Batch No. and date of manufacture. Certificates from NABL approved labs shall be submitted with test results, for at least following parameters - (i) Composition of Earth Enhancement compound (ii) Resistivity - <2 Ohm-meter (iii) pH value - >7 but <9 (iv)Moisture retaining capacity - >10% at 105 degrees Celsius (v) Water solubility - <5%. 4. Backfill material - Good quality soil or excavated soil free from sand, gravel and stones shall be used for backfilling. 5. Earth pit of size 5 feet x 5 feet x 10 feet or min 300 mm bore up to 10 feet using earth auger shall be made. 6. Inspection chamber - A concrete box of 300 x 300 x 300 mm (inside dimensions) and 50 mm thickness of wall, with smooth cement plaster finish shall be provided on the top of the pit. A concrete lid, painted black, approximately 50 mm thick with pulling hooks shall be provided to cover the earth pit. PVC sleeve shall be provided in concrete wall to take out earthing connections. 7. On backside of the cover, date of the testing and average resistance value shall be written with yellow paint on black background. 8. Instead of copper bus- bar and strips mentioned in the drawing, a GI main bus-bar of minimum size 300 mm x 75 mm x 8 mm to be installed on nearby wall etc. It shall be connected to earthing with two GI strips of 50 mm x 6 mm size each, up to a distance of 10 meters from earth bus-bar (minimum 3 meters x 2 Nos GI strips to be supplied). 9. Earthing shall generally be carried out in accordance with the requirement of I.E. Rules, 1956, as amended from time to time and shall confirm to IS: 3043 of 1987 with latest amendment. 10. The earth value shall be measured and recorded at the site by painting on earth pit or nearest wall along with date of testing. It shall be less than 2 Ohms and neutral to earth voltage shall be less than 3 Volt. 11. Earthing performance after a year of installation shall be jointly checked and measured. It should be less than 2 Ohm. 12. General arrangement of the earth system shall be as the drawing given in Annexure-XXI of tender document. | — | — | — | 3,52,342 | |
| — | 6.00 | — | — | ||
| Providing copper plate earthing - The price shall cover for providing Copper plate earthing made from Copper plate of 600 mm x 600 mm x 3.15 mm thick (approximately) buried at not less than 2.5 m deep in soil along with charcoal and salt layer alternately. The earth connection should be made with PVC insulated stranded copper conductor of 16 mm2 from earth electrode to earthing bus bar/apparatus. The earth pit shall be 4 m away from the other earth pits and at least 30 m away from the earth pit of Lightning Arrestor. The potential difference between earth and neutral of filtered/stabilized source should be less than 2 Volt. The earthing installation should be provided with RCC circular box with cover and G.I. "J" bolts. The earthing should be carried out as per IS 3043/1987 or latest and relevant I.E. regulations. The contractor shall maintain the earth resistance below 0.5 and joint testing report along with railways' representative shall be submitted to the site-in-charge. | — | — | — | 75,042 | |
| — | 1.00 | — | — | ||
| Dismantling, shifting and re-installation, testing and commissioning of existing DG Set, 415 Volt, three-phase, 250 KVA capacity complete with AMF Control Panel and foundation - The price shall cover for removal of existing old LT Panel from DG Set Room and shifting at new location as directed by Site Engineer. The scope of work involves removal of existing Old LT panel from the DG Set room and shifting it in a safe and secure manner to the new location as directed by site engineer. The scope of work also includes safe disconnection of all incoming and outgoing cables from the panel before re-installation and their subsequent reconnection after the panel has been installed. Requirement of termination lugs for all the cables is considered to be in the scope of work. A PCC (1:2:4, M-20 grade) foundation of weight 2.5 times the operating weight of the Genset with enclosure or as recommended by the Genset manufacturer OEM/OEA, whichever is higher, is required to be provided and is included in scope of work for SITC of Genset. 300 mm of this foundation height should be above the ground level. The length and breadth of foundation should be at least 250 mm more on all sides than the size of enclosure. Genset should be mounted on AVM's inside the enclosure. Design of the foundation as recommended by the OEM shall be submitted by the contractor before execution of work along with the drawings. Sufficient space should be available around the Genset for inspection and service. | — | — | — | 63,228 | |
| — | 4.00 | — | — | ||
| Removal of unused existing rail poles complete with overhead line spans and other accessories and shifting the released poles - The price shall cover for removal of existing rail/tubular poles and complete structure and other accessories by digging pole from base with required tools, tackles and manpower in a safe and secure manner. The dismantled rail/round poles, cross-arms, insulators, M.S. clamps, G.I. pipes and released fittings if any shall be segregated, transported and handed over to the site engineer at his office/stores with delivery challan. | — | — | — | 8,952 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TechSpecsofEnergyEfficientLEDBasedLuminaire.pdf
ATTACHMENT
RailwayBoardsletterNo.2018_CE-I_CT_9dated04.06.18.pdf
ATTACHMENT
WesternRailwaysSpecificationsforACBLTPanelsMCCBandMCB.pdf
ATTACHMENT
2024_06_03InstructionforincorporatingtheJPOCircularetc_ProvisionsintheTenderDocumentforallworksrequiringdiggingworksclosetoRly1.pdf for cable
ATTACHMENT
BankGuaranteeverification.pdf
ATTACHMENT
SignagesStandardSizes-PtI.pdf
ATTACHMENT
SignagesStandardSizes-PtII.pdf
ATTACHMENT
TenderDocument-BRC-EL-P-23-26-27NEWGCC.pdf
ATTACHMENT
2024_06_03InstructionforincorporatingtheJPOCircularetc_ProvisionsintheTenderDocumentforallworksrequiringdiggingworksclosetoRly1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .