| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.2 Cr+₹8.8 L (8.03%)Rejected-AOC 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.2 Cr+₹8.8 L (8.03%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹1.3 Cr+₹19.0 L (17.3%)Rejected-AOC | ₹1.3 Cr+₹19.0 L (17.3%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹1.3 Cr+₹20.1 L (18.3%)Rejected-AOC HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹1.3 Cr+₹20.1 L (18.3%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹1.4 Cr+₹29.2 L (26.6%)Rejected-AOC D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | UTTAR PRADESH | 250004 | ₹1.4 Cr+₹29.2 L (26.6%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
12 Nov 2022, 6:00 pmClosed
CWE HILLS Dehradun
HQ CWE HILLS Dehradun, Mall Road, Dehradun Cantt- 248003
ADDN/ ALTN CUM SPECIAL REPAIRS OF THREE OTM (160 OR) ACCN AT RAIWALA
2022_MES_556498_1
86377/RWL/E8
Open Tender
Civil Works
Item Rate
240 days
AGE I Raiwala
Class B Category a(i)
7 documents required · 7 mandatory
₹1,000
Yes
AGE(I) Raiwala
₹2.2 L
Yes
24 Dec 2022
8 Oct 2022
19 Nov 2022
8 Oct 2022
12 Nov 2022
31 Oct 2022
Amount
Surface dressing n exc 15 cm deep and getting out in soft/ loose soil and removing surplus soil to a distance n.exc. 50m and making good surface complete all as specified and directed.
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation etc / for laying of cable etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removal of surplus spoil to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Removing excavated material exc 1.5Km but n.exc 5.0 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for PCC (1:7:12) Type F2 (40 mm graded aggre-gate) as in foundations, sunken portion filling and mass-concrete complete all as specified and directed.
M&L for post construction anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for Cement concrete ( reinforced) including removal of debris etc to a distance out side MoD land complete all as specified and directed.
M&L for RCC (1:2:4) Nominal mix (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed.
M&L for RCC (1:2:4) Nominal mix (using 20mm graded stone aggregates) as in Chajjas/ fins/ facia of roof slab complete all as specified and directed.
M&L for formwork for rough finish to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for formwork for rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed.
M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and directed.
M&L of treatment of spalled concrete cover of RCC section as per manufacturer’s instructions with following course of description below :- (a) Prepration of existing surfaces like chipping of unsound weak / loose concrete/cover of reinforcement & support the structure provisionally during repair work and maintaining them in position till required (b) Clean exist reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, etc, complete and applying two coats of alkaline rust converting primer Sika RustOff-100 or equivalent with a coverage of 350gm/sqm on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats.
(c) Providing and application of zinc rich epoxy antocorrosive protective coating for rebar corrosion protection system Sika Friazinc R® or equivalent in 2 coats of 0.4 kg/m2. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/mm2 according to ASTM C 882-78. (d) Fixing additional TMT rebar Fe415 in various structural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive Sika AnchorFix 3030 Tropical or equivalent complete incl drilling of 10-16 mm dia upto 100 mm deep for rebaring complete all as specified and directed. Note : TMT bar shall be measured and paid separatly.
(e) Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacture specification including preparation of surface by chipping and thoroughly cleaning of surface complete wherever required with with Sikadur®-32 LP or equivalent in consumption of 0.4 kg/m2. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strength should be 10 MPa. (f) Rebuilding the section of structutal damaged spalled concrete or RCC elements to its original size in average thickness of 15-20mm by providing and applying with pre-batched, one component fiber reinforced cementitious patch repair mortar Sika® MonoTop® -122 F or equivalent having compressive strength >= 50 N/mm2 (28 days) according to ASTM C 109; flexural strength >= 5N/ mm2 (7 days) according to ASTM C 293-79.
M&L for drilling 12mm dia x 200mm deep in various structrural elements such as columns, beams and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with epoxy acrylate based anchoring adhesive complete all as specified and directed.
Demolition of brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with old size full brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for brick work with old size half brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
Supply only WPC integral water proofing compound complete all as specified and directed.
Demolition of concrete (un-reinforced)of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of PCC in ground floor and pavings not exc 15 cm thickness below or above ground level including removal of rubbish out side MOD land complete all as specified and directed.
Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any othet loose material and removing the demolished material outside the MOD land complete all as specified and directed.
M&L for PCC (1:1.5:3) type A-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed with integral water proofing compound as per manufactur direction). Note :- integral water proofing compound will be measured and paid seperately.
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregates, as in kerb/ benching/ coping, bed plates, for fixing of hold fast, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D2, (40 mm graded stone agg) as in sub base of floor/ hardstanding/ footpath complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B0 (12.5 mm graded stone agg) as in sub floor of flooring complete all as specified and directed.
M&L for 30mm thick PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate, as in floor mixed with polymer modified repair mortar (SBR Latex liquid polymer) as per manufacturer direction complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately.
Roughening surface of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc complete all as specified and as directed.
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
M&L for 15mm thick plastering on fair faces of brick wall in CM (1:6) surface finished even and fair complete all as specified and directed.
M&L for 15mm thick plastering in CM (1:4) on fair faces of brick work or concrete walls external surfaces of toilets area, shaft and RCC column with polymer modified repair mortar (SBR Latex liquid polymer will be mixed as per manufactur direction and paid separately under relevent item of Sch A) complete all as specified and directed.
M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed. Note :- WPC (Liquid type) shall be measured and paid separately as supply only.
M&L for 10mm thick rendering on fair faces surface in cement plaster (1:3) as in ceiling and fininshed surface even and fair complete all as specified and directed.
M&L for preparing old decorated plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot and applying two coats of white wash complete all as specified and as directed.
M&L for three coats of white wash on new ceiling surfaces including preparation of surfaces complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.
Note:- (i) The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I). (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
M&L for preparation of old decorated surface of exterior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint of required shade (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of point and as directed at site by Engineer-in-Charge.
Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour and T&P required for preparation of surface are demand to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I). (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
M&L for preparation of newly plastered surface of interior wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacturer of paint/ distemper and as directed at site by Engineer-in-Charge.
Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of old decorated surface of interior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge .
Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I).
S&F 5mm thick beveled edge best quality looking mirror of size 600x450 mm with 30mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 6mm thick AC bldg board complete all as specified and directed.
S&F 150mm stainless steel peg set complete all as specified and directed.
S&F plain mild steel wire 4mm dia (GI wire), galvanised class 3, fixed with GI pipes along with straining and necessary fittings in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes etc complete all as specified and directed.
S&F mild steel adjustable hook both side (min 250mm to 300mm), solid body, fixed to walls with suitable fastener for fitment of steel wire hanging lines complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of following size complete all as specified and directed:-
Area not exc 1.5 sqm each
Area exc 1.5 sqm but not exc 4 sqm each
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) including refixing in the other opening of following size complete all as specified and directed:-
Area not exc 1.5 sqm each
Taking down and refixing shutters in the same opening of any description including easing and adjusting, of following size complete all as specified and directed:-
Area exc 1.0 sqm but not exc 2.0 sqm each
M&L for MS fastner of size 200 to 250mm for fixing wooden door frame and like in postion complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other frames/ chowkhat of following size comprising of virgin PVC polymer having K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction :-
Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable and variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. (ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately.
50mm x 100mm size
65mm x100mm size
65mm x 125mm size
S&F flush shutters, ISI mark, solid core construction with block board core and ply wood face panels, commercial type on both sides for following thickness complete all as specified and directed:-
35mm thick
M&L for 30mm thick factory made solid WPC (wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texteure, including stainless steel wire mesh shall be fixed with 15 x15 mm square tube in side rails with screwing 8 x 28 heat metal zink coated screw can be remove or fix again after changing of wire mesh, when needed. The density of the shall be as per manufacture instruction compete all as specified and directed.
M&L for 30mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk stainless steel screws complete all as specified and directed. Note: stainless steel butt hinges and necessary stainless steel screws shall be paid separately.
S&F factory made steel windows with side hung shutters (glazed and gauged shutter both) including box type hinges with steel handle, Z-section handle and steel peg stay complete with glazing bars, dovetailed or welded including a shop coat of red oxide zinc chrome primer complete all as specified and directed. Note :- (i) Measurements shall be taken and paid compositly for frame, glazed and gauged. (ii) Grill shall be measured and paid seperately under respective item. (iii) No extra claim shall be entertained on this ground.
S&F factory made steel ventilators with top hung shutter including box type hinges with steel handle and Z-section handle and steel peg stay complete with glazing bars, dovetailed or welded including a shop coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer including preparation of new wood or wooden base surface over 10cm width or grith complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised (ISI marked) of following size complete all as directed and specified:-
150 mm long
125 mm long
S&F anodised aluminium barrel tower bolts (ISI marked) of extruded section of following size complete all as directed and specified:-
300 mm long
200 mm long
S&F anodised aluminium sliding door bolt (ISI marked) with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of following size complete all as specified and directed:-
300mm long
S&F stainless steel non magnetic butt hinge (ISI marked) of following size complete all as specified and directed:-
S&F floor door stopper (ISI Marked) of aluminium alloy body and tongue anodised, with hard drawn steel spring, fixed in floor of following size complete all as specified and directed :-
150mm long (overall length of cover plate)
S&F 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate (ISI Marked) complete complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or wire staples complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and or riveted or forged into spikes, framed, barred iron door, ladders, fencing work ect. conforming to Fe-290 Gde E-165 complete all as specified and directed. Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts), providing and fiitings angle cleats, fish plates, gusset plate etc., also for welding plumbing, truing up and fixing complete. No claim whatso ever shall be entertained by Govt on this account.
S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete.
S&F stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for following bore of pipe complete all as specified and directed :-
100mm bore pipe
75mm bore pipe
Demolition of existing roof treatment i.e APP membrane including cement mortar screed, brick tiling including mud mortar or lime concrete and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material and removing unserviceable material, outside of A 1 defence land complete all as specified and directed. Note for all item of roof treatment :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof. (b) The rates quoted shall deemed to be included for these items. (c) The work will be measured only after stage passing by AGE(I).
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone agg) mixed with Liquid intergal water proofing compoud as per manufacturer direction and finishing the surface even and smooth with out using extra cement as in roof padding/ leveling course of slope over roof to receive roof treatment complete all as specified and directed. Note :- Liquid intergal water proofing compoud shall be measured and paid separately as supply only.
M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface complete all as specified and directed.
M&L for 15mm thick protection plaster in CM (1:4) as in floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ) complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately..
M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
Note : (i) The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor. (ii) The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items.
Supply only SBR Latex liquid polymer of approved make complete all as specified and directed.
M&L for two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge complete all as specified and directed. Note : Ponding test :- After water proofing coating, ponding test willl be done for ponding for 48 Hrs.
M&L for 40mm dia GI pipe, medium grade, as in spout pipe, projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge complete all as specified and as directed.
M&L factory made, 70 mm thick, precast steel fibre reinforced concrete (SFRC) of any shape and size, manhole/ drain cover (medium duty) with and including handle, of 8mm dia MS TMT bar @150mm c/c in both way and 0.80 mm thick MS sheet frame epoxy painted provided to manhole/drain cover to prevent from chipping of edge complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed .
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty/ wooden/ PVC/ aluminium beading, in square n. exc 0.5 sqm in each pane complete all as specified and as directed.
S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight per sqm not exc 4kg complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises from MoD land complete all as specified and as directed.
M&L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick, of following size, as in floor etc with and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed :- Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I).
Area of each tile exc 0.06 Sqm but not exc 0.11 Sqm.
M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8mm thick, as in dado etc incl 10 mm thick rendering in CM (1:3), set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I)
S&F in repairs for stainless steel non magnetic curtain rod of 25mm dia with and including fixing brackets and decorative type knobs (as approved by AGE (I)/ GE both side of each rod complete all as specified and directed. Note: - Measurement will be taken between end point of knobs.
S&F aluminium door seal upto 1200mm long on bottom of door complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic seat and cover, white, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., complete all as specified and directed.
S&F in repair vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed.
S&F vitreous china bowl urinal flat back size of 465 x 355 x 265 mm, white with grating, union for discharge pipe on bracket excluding flushing cistern flush pipe complete and all as specified and directed.
S&F brass CP urinal spreader fixing with 15 mmdia pipe complete and all as specified and directed.
S&F in repair vitreous china wash hand basin, white, flat back, size 550mm x 400mm excluding taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed. Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc.
Supply only 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, of following capacity of tank complete all as specified and as directed:-
Capacity 1000 Ltrs
S&F ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes or brass ferrule and fixed of following size complete all as specified and as directed :-
20mm bore ( minimum weight 210gms)
S&F in repair PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approvrd by GE complete all as specified & directed. MAKE: Parryware, Model E8090 SLIMLINE or equivalent model of make as specified in appendix.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of following size complete all as specified and as directed :-
110 mm bore
75 mm bore
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of following size complete all as specified and as directed :-
110 mm bore
75 mm bore
S&F PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of following size complete all as specified and as directed :-
110 mm bore
75 mm bore
S&F PVC (SWR) bends with access door any radius of following size complete all as specified and as directed :-
110 mm bore
75 mm bore
S&F PVC (SWR) junction single, (single T) equal or unequal of following size complete all as specified and as directed :-
110 mm bore
75 mm bore
S&F PVC (SWR) vent cowl of following size complete all as specified and as directed :-
75 mm bore
S&F PVC (SWR) multi floor trap, out let dia 75mm, plain with grating including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) floor trap, out let dia 75mm, plain with grating including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) P trap, out let dia 110mm, plain with grating including jointing with solvent complete all as specified and as directed.
S&F 110mm PVC (SWR) WC connector with lip ring complete all as specified and as directed.
S&F 110mm PVC (SWR) WC connector with lip ring complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required of following size complete all as specified & directed :-
100mm bore
Demolition and breaking up drain pipes (PVC/ SGSW/ AC/ RCC pipe) of following bore of pipe, set in cement mortar complete all as specified and as directed:-
100mm bore
M&L concrete bed to pipes in PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for following bore sewer pipe line complete all as specified and directed :-
100mm bore
M&L for salt glazed stone ware (SGSW) pipe, grade A, ISI marked, laid in trenches and jointed in CM (1:1) for following bore of pipe complete all as specified and directed :-
100mm bore
S&F in repair towel rail 600mm long of PTMT fixed with and including CP brass screws and wooden cleats having min weight 190 gms complete all as specified and directed.
S&F glass self assembly consisting of 5.5mm thick sheet glass self 12cm wide with chromium plated bracket guard and rail 60cm long and fixed with CP screws and wood cleats with wall complete all as specified and directed.
M&L for louvres and jallies of precast cement concrete (1:2:4) type B0 (12.5mm graded aggregate), measured solid, including all mouldings but excluding frame (Pre cast frame shall be measured separately) set in CM (1:4) of following size complete all as specified and directed:- Note:- Precast RCC Jallies shall be procured from approved manufacturer as approved by AGE(I).
50mm thick
S&F in repair gunmetal globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed, for following bore complete all as specified and directed:-
20 mm bore
S&F in repairs 15mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle or concealed screwed both ends for iron pipe or for unions complete all as specified and directed. Note for all CP item :- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S&F in repair 15mm bore stop angle valve, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 15 mm bore bib taps, chromium plated, fancy type, long body, cast copper alloy with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed .
S&F in repair 15 mm bore brass chromium plated shower rose 125mm size complete all as specified and as directed.
Supply only PVC connection 15 mm size with PTMT nut of following length complete all as specified and directed :-
S&F in repair 127mm dia round grating chromium plated complete all as specified and directed.
M&L for mirror polished machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 15mm thick screed bed in cement mortar (1:3) complete all as specified and as directed Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
M&L for machine cut kota stone stair case trade flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 15mm thick screed bed in cement mortar (1:3) complete all as specified and as directed. Note : Only one stone piece on one trade with nosing one side must be use.
Description same all as per item No 122 above, but as in riser of steps ( 10-12mm thick Kota stone ) over and including 10mm thick rendering in cement mortar (1:3) complete all as specified and as directed. Note : Only one stone piece on one riser must be use.
M&L for rubbing and mirror polishing to old kota stone flooring to give high gloss finish complete all as specified and as directed.
M&L for 18-20mm thick pre polished udaipur green stone (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including rubbing and polishing over and including 15mm thick screed bed in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of stone complete all as specified and as directed.
M&L for chequered cement concrete tiles, ISI Marked, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors over and including 15mm thick screed bed in cement mortar (1:4) for following size of tile complete all as specified and as directed:-
30cm x 30cm x 25mm thick
S&F soap dish recessed type (stainless steel) fixed with CP screws and wood cleats with wall complete all as specified and directed.
Taking up or down steel water tubing (GI Pipe) and connections of following bore complete all as specified and as directed :-
15mm bore
20mm bore
S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling of following bore complete all as specified and as directed :-
15mm bore
20mm bore
25mm bore
Refixing old galvanised steel water tubing, with all new fittings (ISI Marked) and fixed to wall, floor and ceiling of following bore complete all as specified and as directed :-
20mm bore
M&L for cutting chases in brick wall, pinning in and making good in cement mortar (1:3) to match with existing surface for following girth complete all as specified and as directed :-
Cutting not exc 10cm girth.
M&L for cutting holes into or through brick walls built in cement mortar and making good in cement mortar (1:3) or PCC (1:2:4) type B1 to match with existing surface of following superficial area complete all as specified and as directed :-
Superficial area not exc 150 sqcm
M&L for cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed.
M&L for forming jambs etc to opening including cutting toothing and properly bonding in to old work also facing, jointing and pointing to match exisiting work complete in CM (1:4) complete all as specified and as directed.
S&F low density polythene pipe (LDPE) of pressure rating 6 Kgf / sqcm fixed to wall or laid in floor etc including fittings of following size complete all as specified and as directed :-
32 mm bore
M&L for writing letters or figures (Block, Roman, Italic or Indian) not exc 30cm high complete all as specified and as directed.
M&L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and including in CM (1:4) mixed with WPC /PCC (1:3:6) type B0 /Bk work in CM (1:4) as required at site and as directed by Engr-in-Charge.
Dismantling and taking down old unserviceable point wiring of any type (light, fan, socket, power etc) complete with fitting such as switches, sockets, ceiling roses, pendants, lamp holders, light fitting etc including CI/ pressed steel terminals, switch box and making good the disturbed surface of wall/ floor etc to match with the existing surfaces of wall/ floor complete all as specified and directed. Note :- (i) If the contractor fail to make good the disturbed surface of wall/ floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute, the decision of Accepting Officer will be final and binding. (ii) Old fittings/ fixtures / accessories like switches, sockets, lamp holders, regulators etc., if found in serviceable condition shall be removed carefully for reuse in the work or taking on charge. (iii) Only old unserviceable items will be considered in credit Sch.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit "medium grade" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:- Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
One light point controlled by two way 5 Amp switch.
Descrition same all as per item No 139 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S&F modular switch piano, 1module, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed.
S&F modular switch piano, 1module, flush type button 15/16 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed.
S&F modular socket outlet, 2 module, five pin 2 in 1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed.
S&F modular socket outlet, 2 module, five pin 2 in1, 15 Amps, flush type, 230 volts AC circuit complete all as specified and directed.
S&F ceiling rose surface bakelite 65 x 25mm dia three terminals complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
S&F LED building security light 1 x 20W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including making necessary electric connection with 1.5 Sqmm, 3 core, PVC insulated copper conductor cable 1100 Volt grade complete all as specified and as directed.
Dismantling and taking down unserviceable sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH, PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:- NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs.
2x4 Sqmm + 1x4 Sqmm earth wire with PVC conduit 20mm dia or more
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated, PVC sheathed, steel armoured, aluminum stranded conductor LT UG cable (Conforming to IS 7098), ISI marked, in trenches / ducts / through GI pipes under roads of following size complete all as specified and directed:- Note:- The earth work, GI pipe shall be measured and paid sepretely.
50 Sqmm, 3½ core.
M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose.
Supply and laying cable protection bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed.
M&L for road cutting of size min 15cm width x 10cm depth for laying of cable including making good the road with PCC (1:3:6) type C2 complete all as specified and directed.
S&F galvanized steel water tubing (GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole of following bore complete as specified and directed :- Note : MS Clamp, nut bolts and washer shall be measured and paid seperatly for fixing with pole etc.
50mm bore
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed.
Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Disconnecting and taking out old damaged existing main switch/ distribution board of MCB/MCCB of any description from wall with and including all fitting and fixture and making good to disturbed surface of wall/ floor to match with the existing wall/ floor etc complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 240V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps rating having following capacity complete all as specified and directed:-
DB SPN, 8 way
S&F connecting & testing sheet metal enclsoure double door type for MCCB DB VTPN 4 way with MCCB 4 pole, adjustable thermal & fixed magnetic type 40-50 Amp, 16 KA, 4 pole complete all as specified and directed. Note: Set the MCCB as per builidng load and distribute the load before charge the load.
S&F connecting & testing MCB, 'B' series/ curve, 230V with rupturing capacity 10 KA of following capacity complete all as specified and directed:-
MCB 6 to 32Amp, SP.
MCB 6 to 32Amp, SPN.
S&F air fresh fan AC single phase 230/240 Volt of size 300mm sweep, metallic body powder coated painted finish, power consumption 50W, air displacement 1290 Cum/Hr, RPM-900 complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed surfaces of wall complete all as specified and directed.
Supply and hanging ceiling fan five star rating with double ball bearing 350 RPM, 1200mm sweep, working on 140-285 Volts AC 50 Hz, PF 0.99 with super energy efficient BLDC motor & power consumption shall not more than 28W under standard test condition along with down rod, canopy and all accessories, with smart remote control, all as supplied by manufacturer and making necessary electrical connection with 3 core flexible copper conductor 1100 volts grade of suitable size (not less than 1.5 sqmm) and length including and making necessary electric connection etc complete all as directed. Note: Contractor shall submit the guarantee from manufacturer for ceiling fan for minimum 3 years for any defects developed during the period.
M/S Manmohan Singh Anand
AKANSHA.ASSOCIATES
M/s Arihant Builders
MOHAN LAL GUPTA
VEE SONS BUILDERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .