Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹28.3 LAccepted-AOC 45 38 15 JAGANNADHAPURAM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | 1 | Accepted-AOC Being Lowest | |
| 2 | 2₹29.9 L+₹94,758 (3.27%)Rejected-Finance | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹33.0 L+₹4.0 L (13.8%)Rejected-Finance | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹33.7 L+₹4.7 L (16.1%)Rejected-Finance 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 4 | Rejected-Finance Not L-1 | |
| 5 | 5₹35.9 L+₹6.9 L (23.7%)Rejected-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | 5 | Rejected-Finance Not L-1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
31 Jan 2020, 6:00 pmClosed
Lt Col Vijay Singh GE
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR MAINTENANCE OF WIRING DBS SUB MAIN WIRING FITTINGS AND EARTHING AT MPETA AND NAMAC AREA UNDER AGE EM OF GE ND VISAKHAPATNAM
2020_MES_313725_1
8872
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
visakhapatnam
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE ND Visakhapatnam
₹86,000
Yes
19 Feb 2020
10 Jan 2020
6 Feb 2020
10 Jan 2020
31 Jan 2020
25 Jan 2020
Amount
The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- [i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time. [ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE. [iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places. [iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work).
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including pressed steel/welded MS terminal boxes made of 2.0mm thick mild steel sheet with 3mm thick hylem sheet top cover including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell / 5 Amps socket point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.
All as per item No. 2 above but for 5 Amps socket point on the same board
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including pressed steel/welded MS terminal boxes made of 2.0mm thick mild steel sheet with 3mm thick hylem sheet top cover including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell / 5 Amps socket point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for B47]
All as per item No. 4 above but for 5 Amps socket point on the same board
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 4.0 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including pressed steel/welded MS terminal boxes made of 2.0mm thick mild steel sheet with 3mm thick hylem sheet top cover including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for 15 Amps socket point on independent board including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 4.0 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including pressed steel/welded MS terminal boxes made of 2.0mm thick mild steel sheet with 3mm thick hylem sheet top cover including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for 15 Amps socket point on independent board including taking down old point wiring with fittings & fixtures complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for cutting, chasing, pinning in and making good disturbed surfaces as required to the satisfaction of Engineer-in-Charge]
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including pressed steel/welded MS terminal boxes made of 2.0mm thick mild steel sheet with 3mm thick hylem sheet top cover including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point controlled by two Nos, two way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.
S & F, Switch Piano, flush type, single pole, one way, 5 Amps, 230 Volt complete all as specified.
S & F, Switch Piano, flush type, single pole, Two way, 5 Amps, 230 Volt complete all as specified.
S & F electronic fan regulator, socket type complete all as specified and directed.
S & F, Bell electric, AC, single pole, 230 Volt complete all as specified.
S & F, Bell push, flush type, 5 Amps, 230 Volt complete all as specified.
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body fixed in repairs complete all as specified.
S & F switch socket combination multipurpose 3 pin, 5 Amps controlled by one 5Amps switch complete all as specified and directed.
S & F switch socket combination, multipurpose, 2 in 1, 3 Pin, 5/15 Amps, flush type, universal controlled by one switch 15 Amps, 250 volts, complete all as specified and directed
Taking down existing ceiling fan of any type and sweep from any position and refixing the same in original position after necessary cleaning for dust, grease, removing defective / burnt out winding and rewinding with super enamelled copper wire of suitable size and applying one coat of synthetic enamel paint (spray painting) including filling the cavities with filler including replacement of defective spares complete all as specified and directed by the Engineer-in-Charge. [Spares shall be measured and paid seperately]
Supply only bearing suitable for ceiling fans of any sweep
Supply only capacitor 2.5 mfd suitable for ceiling fans of any sweep
Supply only fan clamp with rubber bush and nuts & bolts suitable for ceiling fans of any sweep
Supply only down rod 450mm long suitable for ceiling fan of 1200mm sweep
Supply only down rod 1200mm long suitable for ceiling fan of 1200mm sweep
Taking down existing light fittings of any type and size and refixing the same in new location complete all as directed
S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and 1800 to 2000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F LED tube light fittings, 2 feet long of 900 to 1000 lumens of cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
Taking down existing exhaust fan / Air circulator / Pedestal fan of any type and sweep from any position and refixing the same in original position after necessary cleaning for dust, grease, removing defective / burnt out winding and rewinding with super enamelled copper wire of suitable size and applying one coat of synthetic enamel paint (spray painting) including filling the cavities with filler including replacement of defective spares complete all as specified and directed by the Engineer-in-Charge.
S & F Building Security light LED type 4500 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge.
S & F Building Security light LED type 2500 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge.
S & F Batten suitable for LED T8 lamps complete all as specified and as directed
S & F PVC box of size 350x250x150mm shock proof, rust proof, with provision for cable entry at bottom and/or sides, weather proof suitable for LT 3 Phase KWH meter complete all as specified and directed
Taking down existing KWH meter and refixing the same after replacement of burnt out wiring and servicing complete all as specified
Taking down old DBs housing MS box of any size from the existing location and making good the surface with necessary brick work in CM 1:6, rendering in CM 1:4 and finishing the surfaces to match with adjoining surfaces complete all as directed
S & F in repairs GI powder coated louvers suitable for exhaust fans 300mm sweep including replaing copper conductor wire complete all as directed. [Note: Quoted rate is deemed to be inclusive for work necessary scaffolding as required for work at any height]
S & F in repairs MCB DB, Vertical TPN, 8 way, double door, 415 Volts with 200 Amps rated bus bar suitable for incomer TPN MCCB with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F in repairs MCCB TPN, 125 Amps, 25 KA
S & F in repairs Rigid non-metallic PVC conduit of 20mm dia complete with accessories such as junction boxes, tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories, lock nuts, saddles, pipe hooks, etc for drawing telephone / TV cables concealed in wall / floor / roof / ceiling including cutting, chasing, pinning in and making good disturbed surfaces as required to the satisfaction of Engineer-in-Charge complete all as specified and directed.
S & F in repairs Rigid non-metallic PVC conduit of 25mm dia complete with accessories such as junction boxes, tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories, lock nuts, saddles, pipe hooks, etc for drawing telephone / TV cables concealed in wall / floor / roof / ceiling including cutting, chasing, pinning in and making good disturbed surfaces as required to the satisfaction of Engineer-in-Charge complete all as specified and directed.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 2.5 Sqmm, drawn through and including suitable size PVC conduit and conduit accessories including provision of 1 run of 2.5 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 2.5 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 4.0 Sqmm, drawn through and including suitable size PVC conduit and conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 6.0 Sqmm, drawn through and including suitable size PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 6.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
S & F in repairs MCB DB, TPN, 4 way, double door, 415 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F in repairs MCB DB, SPN, 12 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F in repairs MCB, 4 Pole, 100 Amps, 415 Volts
S & F in repairs RCCB, Double Pole, 30mA, 40 Amps complete all as specified
S & F in repairs MCB, SP, 6 to 32 Amps, 240 Volt, 'C' series
S & F in repairs MCB, SP, 40 Amps, 240 Volt, 'C' series
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 2 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking out old cable complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 2 core 6 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking out old cable complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
M & L for laying sub class 'B' bricks of old size 230mm x 115mm x 75mm for cable protection laid across alignment of cable in trenches complete all as specified and directed.
S & F in repairs Switch Piano, flush type, single pole, one way, 6 Amps, 230 Volt complete all as directed.
S & F in repairs Switch Piano, flush type, single pole, one way, 16 Amps, 230 Volt complete all as directed.
S & F in repairs switch socket combination multipurpose 3 pin, 5 Amps controlled by one switch 5Amps flush type complete all as specified and directed.
S & F in repairs switch socket combination, multipurpose, 2 in 1, 3 Pin, 5/15 Amps, flush type, universal controlled by one switch 15 Amps, 250 volts, complete all as specified and directed
S & F in repairs electronic fan regulator, socket type complete all as specified and directed.
S & F in repairs ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
S & F in repairs MCB, DP, 32 Amps
S & F in repairs sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth strip 32x6mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
KANAKAJYOTHI ENTERPRISES
SRI SAI VAGDEVI BUILDERS
SAI KRISHNA ASSOCIATES
Mavee Syndicate
Kiran Engineering Works
RATNA ENTERPRISES
R AND A ASSOCIATES ENGINEERS CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .