Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
2 Jan 2024, 6:55 pmClosed
CWE (AF) KALAIKUNDA
CWE (AF) KALAIKUNDA KALAIKUNDA AIR FIELD POST WEST MIDNAPORE DIST WEST BENGAL- 721303
REPAIR/MAINT OF HT UG CABLE, LIGHTENING ARRESTER, HT INSULATOR, GANG OPERATED DEVICES FOR 2 POLE STRUCTURE, 4 POLE STRUCTURE AND CONNECTED ALLIED WORKS
2023_MES_631247_1
8291/BKP/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AT AF STN BARRACKPORE
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (AF) BARRACKPORE
₹40,000
Yes
3 Apr 2024
5 Dec 2023
4 Jan 2024
5 Dec 2023
2 Jan 2024
19 Dec 2023
Amount
Disconnecting HV/LV Connections of Transformer,as per Original Equipment Manufacturer's (OEMs) reccommendations including disconnecting of earthing lead, unscrewing nuts, bolts and washers, testing their un-serviceability (Open and Closed circuit test) with the help of composite unit of Transformer 100 to 350 KVA 6600/433, and isolation transformer of any capacity & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and .
Opening Top Lid Cover of Transformer 100 to 350 KVA 6600/433 indoor/outdoor, as per Original Equipment Manufacturer's (OEMs) reccommendations and disconnecting all Internal Connections of HT/LT Side for Periodical Maintenance such as Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, etc. & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
Taking down carefully defective transformer of 100 to 350 KVA 6600/433 indoor/outdoor and from foundation base including draining out old transformer oil complete carefully and keeping the same in a cleaned container in safe custody for re use after repair works of transformer and transportation from site to contractors workshop and back to site after repair, connecting HT as well as LT side to existing system, testing and commisioning all as & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and .. NOTE : Transformer Oil to be re-used should be dehydrated/ filtered under respective items.
M&L for open the top cover of transformer of capacity 100 KVA to 350 KVA, after disconnecting HT/LT connection, drain out of transformer oil and preserve it in container, replacement of all gasket for prevention of leaking, replacement of broken HT/LT bushes complete as per existing size all as directed, refixing all connection and testing on load & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified [NOTE FOR ITEM No. 1.00 to 4.00:- (a) Cost of Transformer Oil for Cleaning by Hosing down shall deemed to be included in the unit quoted rate. (b) Gasket set, LT/HT side ceramic bushing, spindle for HT/LT side and horn surge arrester etc. for replacement shall be measured and paid under relevant items.]
M&L for rewinding of LT copper strip coil for off sizes transformer after removing unserviceable as per Original Equipment Manufacturer's (OEMs) reccommendations Insulating Materials, Re-insulation and Re-winding as per existing Size of Core of Transformer including Heating, Varnishing, etc., & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified.
M&L for rewinding as per Original Equipment Manufacturer's (OEMs) reccommendations of HT wire coil for off sizes transformer using Proper Size new Copper Wire and HV Insulating Materials suitable for Working Voltage 6.6 KV & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
Supply & Fix Ceramic Bushing and Gasket on HT Side of Transformer 100KVA to 350KVA 6600/433 or 11000/433 as per Original Equipment Manufacturer's (OEMs) reccommendations & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
Supply & Fix Ceramic Bushing and Gasket on LT Side of Transformer 100 KVA to 350KVA 6600/433 as per Original Equipment Manufacturer's (OEMs) reccommendations & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
Supply and fix Breather Assembly filled with Silica Gel 500 gm, as per Original Equipment Manufacturer's (OEMs) reccommendations & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
Supply & Fix Brass Spindle for Terminal on HT Side Threaded complete with Nut, Washers, etc. of dia as ordered, as Approved and suitable and suitable for Transformer 100 to 350 KVA 11000/6600/433, as per Original Equipment Manufacturer's (OEMs) reccommendations & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
Supply & Fix Brass Spindle for Terminal on LT Side Threaded complete with Nut, Washers, etc. of dia as ordered, as Approved and suitable and suitable for Transformer 100 KVA to 350KVA ,6600/433, as per Original Equipment Manufacturer's (OEMs) reccommendations & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
S&F Gasket (Cock Sheet) 6 mm thick with Conical Rubber Bush Complete as approved and suitable for Transformer 100KVA to 350 KVA 6600/433 Volt including taking down/ out unserviceable Gasket, as per Original Equipment Manufacturer's (OEMs) reccommendations & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
M&L for apply one coat of synthetic enamel paint by spray painting including preparation of body of transformer 100KVA & 350 KVA,6600/433, & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
S&F in repair for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Supply, replacement and topping up new Transformer oil EHV grade as per IS 335 of 1993 Part II having die electric strength not less than 40 KV in the Transformers at various locations complete all as specified and as directed by Engr-in-Charge. Make of Transformer oil : Transol/Power oil/any brand of Indian oil corporation). Note : Transformer oil should be heated and should having dielectic strength not less than 60 KV. (ii) Transformer oil shall be bring in sealed barrel having proper test certificate from manufacture
M&L in repair for Filteration and dehydration of HV grade transformer oil of distribution and Power transformer of out door type of 100 to 350 KVA min three cycle to achive die elctric strength of 40 KV to 60KV for 1 Minute at 4 mm gap as per relevent IS complete all as specified and directed. Note : (i) Filteration to be done by Dehydration machine till the desired level of dielectric strength of tranformer oil comes to 60 KV . (ii) Each sample of oil will be tested with a transformer oil test machine at site in presence of concerned JE's/Engr-in-charge and test result will be submitted accordingly). (iii) Centrifugal machine with all T&P and Testing Machine , oil required shall be arranged by contractor. (iv) Oil required for topping up the transformer oil will be measured and paid seperately in relvent item.
M&L in repair of HT 6.6 KV outdoor gang operated air-break switch suitable for horizontal or vertical mounting with drop out fuse having 12 insulators of rating upto 200 Amps as per Original Equipment Manufacturer's (OEMs) reccommendations & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
S&F in repair Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amp 6600 Volt as per Original Equipment Manufacturer's (OEMs) reccommendations & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of six months HT Switch air break ( GOD) 6.6 KV TP with replacement of Corroded nut Bolts, ACSR Jumpers, making alignment of operating Mechanism for Proper ON / OFF operation of GOD and male contact including greasing & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint,with and including dismantling unserviceable complete all as specified and as directed.
M&L for ACSR conductor, proper jointing with suitable clamps and termination with the help of suitable lugs in GODs,Drop Out units, insulators and cable end terminations etc of weasel with permissible sag as per IS rules etc all as specified and as directed.
S&F in repair Disc type insulator, porcelain, vitreous 145mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for couductor, working pressure 11000 Volt, complete all as specified and as directed.
M&L in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut150mm height, 150mm dia for 11000 volts grade, complete all as specified and as directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and as directed.
Excavation in trenches not exceeding 1.50 m wide and n.exc1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed. Note: Excavation for laying of cable to be done manualy, carefully without distrubing existing cable or water pipe lines. If any damaged occured to exiting cable and pipe line during excavation, contractor has to repair it with in time limit without any extra cost. If contractor delayed in repairing, Panality @ of 500/- per hour to be charghed, if repairing is not carry out within 12 hours.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 m and deposited/ spreaded where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
Taking out defective HT UG cable alongwith PCC cover from trenches complete all as directed.
Supply, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable punned down to 18 cm for under ground cable complete all as specified and as directed. Note: For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type I, flat, as per IS - 5820 of size 300mm x 180mm x 40mm, laid perpendicular to the length of UG cable in trenches complete all as specified and directed .
Re-laying of un-reinforced precast concrete cable cover, class HV, type I, flat, as per IS - 5820 of size 300mm x 180mm x 40mm, laid perpendicular to the length of UG cable in trenches complete all as specified and directed .
Supply, laying & testing and connecting cable HT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm, ( earth grade) ISI marked with valid CML no, complete all as specified and directed.
M & L for detecting of fault in 11KV (E) HT cable of any size (within 1 KM to 3 KM length), 3 core laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, echo fault locator with high frequency distance calculator etc and exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as specified and as directed by Engineer-in-Charge. Note: - (i) The quoted rate shall deemed to include for the cost of earthwork excavation as required. (ii) Cable if replaced & Jointing kit shall be measured & paid separately. (iii) As the work is releated to maintenance, the work of fault detection has to be carry out on Priority and on requirement basis as on occurance of fault within 24 hrs so as to rectify the fault and to restore the electric supply of stn. If contractor delay the job, necessary panlty at the rate of Rs 1000.00 per hrs (after 12 hrs) will be imposed on contractor.
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of 06 months including disconnecting and taking out existing HT 6.6 KV to 11 KV VCBs of any make from housing and cleaning, rubbing and servicing/overhauling , Calibration and decarbonising the mechanical parts and Servicing of 6.6 KV to 11 KV in door VCB, checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing ( IR value, Ratio test, Polarity test) and connection verification of 6.6 KV to 11 KV Current transformer( Set of three) by PRIMARY INJECTION KIT ,and Testing and calibration of relay( set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and .
S&F Vacuum Interrupter type VG 2EN with TC suitable for 6.6 KV to 11 KV VCB Panel as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
S&F Vacuum Interrupter with TC suitable for 6.6 KV to 11 KV VCB Panel as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
S&F breaker charging motor including Gear assembly 110 volt/ 220 Volt AC suitable for 6.6 KV to 11 KV VCB panel, as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
S&F Multifunction meter square type Digital of size 96 Sqmm of capacity 0 to 15 KV PT Ratio 6.6KV/110 Volt as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
Supply, installation, testing and commissioning of Micro processor base relay (02 O/C + 01 EF) for 6.6 KV to 11 KV VCB panel , rating 5 Amps, Auxiliary supply 20-110 Volt DC as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
Supply, installation, testing and commissioning of voltage operated auxiliary relay with SR contacts for 6.6 KV to 11 KV VCB panel , coil rating 24V DC with operational time 20-25 ms, as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
M & L for Trip and Close switch for 6.6 KV to 11 KV VCB panel 02 Amps/110 volt with locking arrengement, as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
S & F 6.6 KV panel indicating lamp fitting LED type suitable for 24 volt/30 volt DC with base, as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
S & F 6.6 KV panel indicating lamp fitting LED type suitable for 110 volt/230 volt AC with base, as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
S & F limit switch suitable for VCB Panels, as per Original Equipment Manufacturer's (OEMs) specification complete all as specified and directed.
Supply installation, commissioning and testing including providing all necessary electrical connection, HT feeder pillar box (CPRI Approved conforming to IEC- 61439), outdoor type ,factory made out of 3 mm thick MS sheet of size 1.0 m x 1.0 m x 0.6 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed by the Engr-in-Charge :- (a) Anodized Aluminium bus bar of capacity 1200 Amp - 03 Nos (b) HT Base insulator for fixing of busbar (03 x 03 =09 Nos)
Note: Schedule of credit amount of Rs 96,228.00 shall be deducted from the total quoted amount of BOQ.
SANKAR TRADERS
ROY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .