Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 20 21 ETA HOUSE RAZAK GARDEN MAIN ROAD RAZAK GARDEN MAIN ROAD CHENNAI TAMIL NADU 600106 | CHENNAI | TAMIL NADU | 600106 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 3 6 753 A GENERAL ELECTRICALS REFRIGERATION 3 6 753 A HIMAYATHNAGAR ST NO 14 40 HYDERABAD TELANGANA 500029 | HYDERABAD | TELANGANA | 500029 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance 107 2 AMPA MANOR IST FLOOR NELSON MANICKAM ROAD AMINJIKARAI CHENNAI 0 600 029 NO 107 2 AMPA MANOR 1ST FLOOR NELSON MANICKAM ROAD AMINIJIKARAI AMINJIKARAI | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
9 Jan 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy Chief Engineer
Dy Chief Engineer 2nd floor Sarathi Building NFC Hyderabad
Providing Hybrid thermal solar (HTS) VRF VRV Air conditioning system for Sarathi Building at NFC Hyderabad
2024_NFC_836936_1
NFC/E/669
Open Tender
Electrical Works
Item Rate
Hyderabad
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹3.4 L
10 Jan 2025
28 Nov 2024
10 Jan 2025
28 Nov 2024
9 Jan 2025
7 Dec 2024
3 Dec 2024 - 6 Dec 2024
Amount
Supply: 60.0 HP HVRF Outdoor Unit
Erection: 60.0 HP HVRF Outdoor Unit
Supply: Centralised controller for each outdoor unit
Erection: Centralised controller for each outdoor unit
HVRF INDOOR UNITS (IDU): Supply, installing, testing and commissioning of Cassette VRF/VRV type unit complete with return air grill and remote control . Outdoor unit consisting of hermitically sealed rotary compressor,necessary safety devices, adequate capacity of air cooled condensor,all mounted on M S Frame and enclosed with a weather type enclosure to protect the electrical circuit and fan winding The indoor unit consists of evaporator fan capable of developing min static pressure,copper refrigerant piping with insulation (not exceeding 9m for each unit) connecting indoor and outdoor units and wired & wireless both type remote controler, includes necessary accessories for fixing and mounting etc all complete as required. The installation to include the breaking and making good walls for refrigerant piping with insulation, indoor to outdoor cabling and wiring to nearest power source as per site conditions. Cost shall include drain pump and necessary arrangement
Supply: 3.2 TR
Erection: 3.2 TR
Supply: 2.60 TR
Erection: 2.60 TR
Supply: 2.0 TR
Erection: 2.0 TR
Supply: 1.60 TR
Erection: 1.60 TR
Supply, installing, testing and commissioning of Compact Cassette VRF/VRV type unit complete with return air grill and remote control . Outdoor unit consisting of hermitically sealed rotary compressor,necessary safety devices, adequate capacity of air cooled condensor,all mounted on M S Frame and enclosed with a weather type enclosure to protect the electrical circuit and fan winding The indoor unit consists of evaporator fan capable of developing min static pressure,copper refrigerant piping with insulation (not exceeding 9m for each unit) connecting indoor and outdoor units and wired & wireless both type remote controler remote controler, includes necessary accessories for fixing and mounting etc all complete as required. The installation to include the breaking and making good walls for refrigerant piping with insulation, indoor to outdoor cabling and wiring to nearest power source as per site conditions. Cost shall include drain pump and necessary arrangement
Supply: 1.28 TR
Erection: 1.28 TR
Supply: 1.0 TR
Erection: 1.0 TR
Supply: 0.8 TR
Erection: 0.8 TR
Supply: 0.63 TR
Erection: 0.63 TR
Refrigerant Joints for Indoor Units.
Supply
Erection
Refrigerant Joints for Outdoor Units.
Supply
Erection
SITC of central control remot with 10" Display
Supply
Erection
REFRIGERANT PIPING FOR HVRF SYSTEM :Copper Ref.piping of the required sizes for all the units with refnets as per specs. The insulation shall be of 19mm thick Armaflex/ KFlex make through out the running length of Ref. piping. The piping shall be well supported at specific intervals with GI supports with insulated PUF saddles and Exposed pipes shall be installed on GI cable trays supported from wall / roof with anchor fasteners & C type ms angle. The pipe sizes are tentitive, the vendors have to consider as per their manufacturing standards. Supply and erection of copper piping of the following sizes 1/4" (6.4 mm) dia., 3/8" (9.5mm) dia.,1/2" (12.7mm) dia,5/8" (15.9mm) dia,3/4" (19.1mm) dia.,7/8" (22.2mm) dia,1 1/8" (28.6mm) dia,1 3/8" (34.9mm) dia.,1 5/8" (41.3mm) dia.
Supply
Erection
Nitrogen Pressure testing & Additional gas charging for the entire length of copper pipes - Refrigerant R410A / Environmental friendly refrigerant.
Supply for 120 HP
Erection for 120HP
Supply & installtioan of CPVC pipe of with 6mm thick nitrile rubber insulation and necessary supports and fixing accessories etc.
Supply: 25mm dia
Erection: 25mm dia
Supply: 32mm dia
Erection: 32mm dia
SITC of hot dipped galvanised perforated cable tray of 1.6 mm thk. and 100 mm height. The width of the cable tray shall be as under. All required supports, fittings, bends, offsets, bolt & nuts, etc. shall be included. This cable tray is meant for laying the copper piping inside the building the building.
Supply:400 mm
Erection:400 mm
Supply:300 mm
Erection:300 mm
Supply:150 mm
Erection: 150 mm
SITC of hot dipped galvanised cable tray without perforations of 1.6 mm thk. and 50 mm height. The width of the cable tray shall be as under. All required supports, fittings, bends, offsets, bolt & nuts, etc. shall be included. This cable tray is meant for covering the copper piping outside the building.
Supply:300 mm
Erection:300 mm
Supply:150 mm
Erection:150 mm
Supply and installation of modular HDG supporting system consisting of a galvanised steel frame supported by adjustable leg and feet assemblies. The frame dimensions should be designed to take the weight with minimal deflection, finite element analysis (FEA) and should be manufactured from hot dip galvanized carbon steel: BS EN 10219-1 to a welding standard: BS EN ISO 15614. The galvanizing standard to be BS EN ISO 1461 with salt mist testing to BS EN 60068-2-52. The feet shall be 305/450mm square made from Nylon 6 B601L 30% glass fiber filled. These shall have mats underneath made from SBR-recycled rubber, bound using a ratio of high quality moisture curing polyurethane pre-polymer to BS 7188 and BS 5696-3. The leg assembly should be adjustable up to 105mm so that the frame can accommodate unevenness of the roof surface. Supporting system shall uniformly distribute the load on the supporting slab.
Supply
Erection
MCC Cum Control Panel of rating IP65 Fully compartmentalised comprising of incoming MCCB outgoing feeders with of suitable rating two spare feeders, comprising of contactors, relays, push button station, start/Stop/Trip Status, Energy meter and lamp facility for remote operation through push buttons Auto manual switches and safety devices complete with Vendor to refer SLD. for FOR ODU suitable capacity. Each outdoor should be given a local controller for isolation during electrical maintenace.
Supply
Erection
4C x 25 Sqmm FRLS armoured Copper Cable For ODU
Supply
Erection
Communication cable for vrf 1.5x3 core with shilded cable with pvc condutes for VRF
Supply
Erection
For each floor, DB with nessary contoles
Supply
Erection
3C x 4 Sqmm FRLS armoured Copper Cable For IDU
Supply
Erection
Supply, Installation, Testing and Commissioning of Underdeck Insulation of ducts with Class 'O' aluminium foil faced cross linked poly ethylene (XLPE) insulation . Insulation shall be fixed with adhesive & joint shall be covered with self adhesive aluminium tape.
Supply
Erection
Comprehensive AMC of Complete VRF/VRV System of SARTHI Bldg. Comprehensive maintenance of ( Routine & Preventive ) and breakdown of high side and low side of the VRF/VRV - 120 HP Capacity Air Conditioning system comprising all the machinery - IDU's ; ODU's , remotes, electrical MCC panel, equipments including spares , consumables , etc. as given in additional terms and conditions complete as required (after One year defect liability period / after warrantee period. Separate Work Order will be issued for the AMC after waranty period in the prices quoted below.
First Year/HP
Second Year/HP
Dismantling, &shifting of existing 3 nos PAC units and 50 nos split/window ACs along with all its accessories like copper piping, ducting( if any), insulation, cables etc.
TOOT MNE TECH PRIVATE LIMITED (BID ID -3150075)
Sri Bhavani Enterprises (BID ID -3135200)
General Electricals and Refrigeration (BID ID -3152158)
GENUINE AIRTECH ENGINEERS (BID ID -3142892)
stage.html
html • 0.02 MB
finance_879659.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .