Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹9.6 L+₹11,230 (1.19%)Rejected-Finance LAKHPURA BUTCHERY MISSAMARI DIST SONITPUR ASSAM PIN 784506 | MISSAMARI | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹11.1 L+₹1.7 L (17.6%)Rejected-Finance AMBAGAN TEZPUR TOWN PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
17 Dec 2021, 6:00 pmClosed
GE MISAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIR/MAINT OF NONCLOGGING PUMP SETS,SUBMERSIBLE PUMP SET INDUCTN MOTOR,STARTER PANEL BOARD AND ALLIED WORKS AT STP INSTNS AT BUTCHERY,PN,SN,223 TC AND CHHATA GHARINCL DESILTERING AND CLNG OF SUMP,BIOFILTER,WELL ETC UNDER GE MISAMARI
2021_MES_483897_2
8217
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MISAMARI
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
Yes
GE MISAMARI
₹20,000
Yes
1 Mar 2022
26 Nov 2021
20 Dec 2021
26 Nov 2021
17 Dec 2021
3 Dec 2021
Amount
Servicing / over hauling of 3 Phase 415 Volts 1440 RPM 40/50 HP capacity induction Motor installed at Sewage Treatment Plant , along with following others repairs. (a). Taking out Motor from its Position by decoupling from Pump and disconnecting all cable connections (b) Dismantaling of induction Motor complete part by part carefully, testing all coils, degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts. (c) Heating & varnishing to stator with super quality varnish and dried out properely with external heat as ordered & directed (d). Reassembeling the motor complete with all existing serviceable parts obtained against Item 1(b), greasing the bearings with bearing grease, and new parts as ordered by Engineer in Charge.( If New parts required shall be measured and paid separately under relevant Item here-in after) (e) Re-install the Motor at its existing Position without any damage, couple with the Pump connecting all cable connections and testing on completion
S & F DE (Driver End) Bearing No. as per existing size MAKE : SKF/NBC suitable for 40/50 HP Motor against Item No. 01 here-in-above, complete all as specified and as directed.
S & F NDE ( Non Driver End ) Bearing as per existing size Make- SKF, NBC suitable for 40/50 HP Motor against Item No. 01 here-in-above, complete all as specified and as directed.
S & F Motor Shaft suitable for 40/50 HP motor to incorporate against each Item No. 01 here-in-above complete all as specied and as directed.
S & F Bakelite connection terminal plate with brass nuts bolts and washers suitable for 40/50 HP Motor against Item No. 01 here-in-above, complete all as specified and as directed.
Rewinding burnt coils of Induction Motor stator of capacity 40/50 HP with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking up/Down, cleaning/ repairing damaged slots, complete all as specified and as directed.
Servicing / Overhauling of Electric driven Non Cloging (NC) Pump set having discharge Dis-378 m³/Hr ,H-15.5 Mtr (Pump – Kirloskar) Installed at Sewage Treatment Plant coupled with induction Motor capacity 30 KW (40 HP) along with following others repairs :- a). Taking out Pump from its Position by decoupling from Motor and disconnecting all suction /delivery water connections , setting aside Pump from base plate , b). Dismantaling of Pump complete part by part carefully , degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts. c). Replacement of Gasket set and gland packing rope. (d) Repair/Welding/Grinding of damaged parts e). Reassembeling the Pump complete with all existing serviceable parts obtained against Item 07 (b), greasing the bearing with bearing grease , and new parts as ordered by Engineer in Charge.( New parts shall be measured and paid separately under appropraite Item here-in-after) f) Reinstall the Pump without any damage at its existing Position , couple with the Motor and connecting all suction delivery water connections and testing on completion complete all as specified and as directed.
S & F DE (Driver End) Bearing as per existing size MAKE : SKF/NBC suitable for 40 HP Motor against Item No. 07 here-in-above, complete all as specified and as directed.
S & F NDE ( Non Driver End ) Bearing as per existing size Make- SKF, NBC suitable for 40 HP Motor against Item No. 07 here-in-above, complete all as specified and as directed.
S & F CI Impeller (PROVISIONAL) of Electric driven Non Cloging (NC) Pump coupled with 40 HP Vertical Motor to incorporate against each Item No-07 here-in-above complete all as specified and as directed.
Welding Turning and machining works of Pump Shaft obtained from Item No 07 here-in-before to true size to match with the new Parts / existing serviceable parts for proper allignment and smooth operation of Motor Pump Set complete all as specified and as directed
Servicing / overhauling of 3 Phase 415 Volts 1440 RPM 20 HP capacity Horizontal/Vertical induction motor ( Make- Jyoti, Kirloskar). installed at STP, Butchery and IMPH Chhataghar along with following others repairs. (a). Taking out Motor from its Position by decoupling from Pump and disconnecting all cable connections. (b) Dismantaling of induction Motor complete part by part carefully , testing all coils , degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts. (c) Heating & varnishing to stator with super quality varnish and dried out properely with external heat as ordered & directed. (d) Reassembeling the motor complete with all existing serviceable parts obtained against Item 12 (b), greasing the bearing with bearing grease , and new parts as ordered by Engineer in Charge.( New parts shall be measured and paid separately under relevant Item here-in after) (e) Reinstall the Motor at its existing Position , couple with the Pump connecting all cable connections and testing on completion.
S& F DE (Driver End) Bearing No. as per existing size MAKE : SKF/NBC suitable for 20 HP Motor against Item No. 12 here-in-above, complete all as specified and as directed.
S & F NDE ( Non Driver End ) Bearing as per existing size Make- SKF, NBC suitable for 20 HP Motor against Item No. 12 here-in-above, complete all as specified and as directed.
S & F Bakelite connection terminal plate with brass nuts bolts and washers suitable for 20 HP Motor against Item No. 12 here-in-above, complete all as specified and as directed.
Rewinding burnt coils of Induction Motor stator of capacity 20 HP obtained from Item Ser No-12 here-in-above with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking out old unserviceable winding, cleaning/ repairing damaged slots, complete all as specified and as directed.
Servicing / over hauling of Horizontal/Vertical Pump set installed at STP, Butchery and IMPH Chhataghar coupled with Horizontal/Vertical Electric Induction Motor stator cap 20 HP along with following others repairs. (a) Decoupling Vertical Motor from Pump shaft and disconnecting all suction /delivery water connections, setting aside Motor from base plate, complete all as directed by Engr-in-Charge. (b) Dismantaling of Pump complete part by part carefully, degreasing bearing and display all the parts without damaging any portion , for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts. (c) Replacement of Gasket set and gland packing rope .(d)Repair/Welding/Grinding damaged parts of Pump casing. (e) Reassembeling the Pump complete with all existing serviceable parts obtained against Item 17 (b), greasing the bearing with bearing grease , and new parts as ordered by Engineer in Charge. ( New parts shall be measured and paid separately under appropraite Item here-in-after) (f) Lowering column pipes multistaging Pump set inside well ,connecting Suction/ delivery Lines, (g) Reinstall the Motor at its existing Position, couple with the Pump connecting all cable connections and testing on completion.
S &F DE (Driver End) Bearing No. as per existing size MAKE : SKF/NBC suitable for 20 HP Motor against Item No. 17 here-in-above, complete all as specified and as directed.
S & F NDE ( Non Driver End ) Bearing as per existing size Make- SKF, NBC suitable for 20 HP Motor against Item No. 17 here-in-above, complete all as specified and as directed.
S & F CI Impeller as per Existing (PROVISIONAL) Pump coupled with 20 HP Motor against Item No-17 here-in-above complete all as specified and as directed.
Supply & F Pump Shaft (PROVISIONAL) coupled with 20 HP Motor against Item No-17 here-in-above complete all as specified and as directed.
Welding Turning and machining works of Pump Shaft obtained from Item No 17 here-in-before to true size to match with the new Parts/ existing serviceable parts for proper allignment and smooth operation of Motor Pump Set complete all as specified and as directed.
Repairs to sewage non clogging/submersible motor of capacity 10/7.5 HP, 3 Phase, 415 Volts involving the following operations Installed at Pratap Nagar sewage Pump House PH No-1 & 2, transit Camp (a). Disconnecting delivery water connections Lifting column pipes along with connected submersible motor Pump set from Sewage open well, setting aside and stacking column pipes for reuse complete all as directed by Engnr-in-Charge. (b). Dismantaling / Opening of submersible Motor complete part by part carefully, testing all coils, degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in-Charge to ascertain the serviceability of existing parts. (c). Reassembeling the motor complete with all existing serviceable parts obtained against Item 23 (b), greasing the bearing with bearing grease , and new parts as ordered by Engineer in Charge.( New parts shall be measured and paid separately under relevant Item here-in after) (d). Painting the repaired motor and column Pipes externally with one coats of red oxide paint and two coat of synthetic enameal paint of shade as directed by Engnr-in-Charge. (e) Lowering column pipes and submersible Motor Pump set inside well, connecting Suction/ delivery Lines, and testing on completion.
Rewinding of non clogging/submersible sewage motor of capacity 10/7.5 HP obtained from Item Ser No-23 here-in-above with water proof insulated copper wire of existing guage and size to achieve the specified/ required RPM including taking out old unserviceable winding, cleaning/ repairing damaged slots, complete all as specified and as directed.
Repairs to sewage non clogging/submersible motor of capacity 5 HP, 3 Phase, 415 Volts involving the following operations Installed at Transit camp (a) Disconnecting delivery water connections Lifting column pipes along with connected submersible motor Pump set from Sewage open well, setting aside and stacking column pipes for reuse complete all as directed by Engnr-in-Charge. (b) Dismantaling / Opening of submersible Motor complete part by part carefully, testing all coils, degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in-Charge to ascertain the serviceability of existing parts. (c) Reassembeling the motor complete with all existing serviceable parts obtained against Item 25(b), greasing the bearing with bearing grease , and new parts as ordered by Engineer in Charge. ( New parts shall be measured and paid separately under relevant Item here-in after) (d) Painting the repaired motor and column Pipes externally with one coats of red oxide paint and two coat of synthetic enameal paint of shade as directed by Engnr-in-Charge. (e) Lowering column pipes and submersible Motor Pump set inside Jackwell ,connecting Suction/ delivery Lines, and testing on completion.
Rewinding of non clogging/submersible sewage motor of capacity 5 HP obtained from Item Ser No-25 here-in-above with water proof insulated copper wire of existing guage and size to achieve the specified / required RPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots, complete all as specified and as directed.
S&F MCCB 4 Pole, 415 Volts, 63 Amps, with Thermal Magnetic release breaking capacity 25 KA fixing on existing LT Panel connecting and testing including taking out unserviceable one from panel, complete all as specified and as directed.Make- L&T/Havells/Indoasian/Legrand
S&F MCCB 4 Pole, 415 Volts, 100 Amps, with Thermal Magnetic release breaking capacity 25 KA fixing on existing LT Panel connecting and testing including taking out unserviceable one from panel, complete all as specified and as directed. Make- L&T/Havells/Indoasian/Legrand
S&F cast iron body and brass gate heavy duty non return valve (NRV) 100 mm bore with flanged end all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable non-return valve (NRV), complete all as specified and as directed. Make- Kirloskar/Sant/Kartar/BIR/KVMC.
S&F cast iron body and brass gate heavy duty non return valve (NRV) 150 mm bore with flanged end all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable non-return valve (NRV), complete all as specified and as directed. Make- Kirloskar/Sant/Kartar/BIR/KVMC
S&F cast iron body and brass gate heavy duty non return valve (NRV) 200 mm bore with flanged end all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable non-return valve (NRV), complete all as specified and as directed.Make- Kirloskar/Sant/Kartar/BIR/KVMC
Desilting/ Taking out accumulated sludge, Silt, Sand and Mud etc. from sewage sump/ well of diameter 6.10 Metre and 12.20 Metre deep ( installed at IMPH Chhataghar & Pump House No.1 & 2 at Pratap Nagar, Transit Camp and Main STP) through Manhole, removing/ disposal off the same from site including provision of T&P complete all as specified and as directed.
M&L for draining out water, scraping out scaling of 7 Mtr deep and 4 Mtr bore/ dia Master Manhole, taking out the sludge from sewage sump/ well upto clear bottom or approximate 1.5 Mtr in depth throwing the sludge 200 Mtr away from the site including provision of T&P complete all as specified and as directed.
M&L Cast Iron Sluice Valve 100mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.Make- Kirloskar/Sant/Kartar/BIR/KVMC
M&L Cast Iron Sluice Valve 150mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.Make- Kirloskar/Sant/Kartar/BIR/KVMC
M&L Cast Iron Sluice Valve 200 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.Make- Kirloskar/Sant/Kartar/BIR/KVMC
M&L Cast Iron Sluice Valve 400 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.Make- Kirloskar/Sant/Kartar/BIR/KVMC
Cutting unaxious green growth and wild grass by manual labour or by machine at all Sewage Installation Premises, along the boundary Fencing, removing rubbish from the Site of Work and deposting where directed not exc. 100 Metre from the starting Point, complete all as specified and as directed. (NOTE : The Item shall be operated in 2 times for the entire Contract period and the measurement will be taken every time independently for Payment.)
Overhauling the reduction gear box assembly fitted in primary/ secondary clarifier by cleaning each job reduction gear box assembly fitted in the primary/ secondary clarifier and applying greasing, filling of gear oil tightening the nuts, bolts including repair/ replacement of unserviceable wheel complete as required at site all as specified and directed.
Overhauling the Bio filter assembly ,complete all as specified and as directed. a) Dismantling Drum,Arms,orifice plates without any damage b) Taking out boulders from bio filter. c) Cleaning Boulders with high pressure jet including biochemical. d) Repair/Replacement of Unsv RCC round slabs e) Desilting silt & Mud from channels and cleaning with f) high pressure jet with Bio chemical. g)Replacement of unsv CI gas Pipeof 80mm Dia including fixing it on RCC slab h) Relaying Bolders after Seggregating Broken boulders i) Filling deficient bolders till the level of Gas Pipe. j) Replacing the Unsv Stainless steel ball in the centre, refilling mercury to the level & changing of unsv orifice plate including cleaning of arms k) Re assembling Drum Arms orifive plate. (New Items required shall be measured and paid separately under relevant Item here-in after)
Over Hauling and cleaning of Digester: (i) Dismantling Motor on the top of the Digester. (ii) opening Manhole Cover with all safty equipments mask, gum Boot etc. (iii) Desilting silt & Mud from channels and cleaning with high pressure jet with Bio chemical. (iv) Painting of Black Bituminous Paint to Digester inner surfaces, rotatory Blade, Shaft etc . (v) Reassembling of Motor after servicing without any damage. (vi) Shutting the manhole cover with tightening the nut bolts.
Cleaning the dry bed of size 30.50 Mtr x 15.25 Mtr in sewage treatment plant by removing all dry sludge and vegetation grown inside the dry bed, complete all as specified and as directed.
Cleaning the Clarifier Chamber (Primary & secondary) by removing deposited mud silt etc. at the bottom of clarifier & depositing the same to a distance not less than 150 mtr away from the installation complete all as specified and as directed.
Cleaning the Raw Water Sewage Sump (Open Type) of dia 7.80 Mtr and 6.60 Mtr deep of Sewage Treatment Plant by removing deposited mud silt etc. at the bottom of Sewage Sump & depositing the same to a distance not less than 150 mtr away from the installation, complete all as specified and as directed.
M & L Fully Automatic Star Delta starter suitable for 25 HP Motor In Sheet Metal Enclosure with single Phase Protection feature ( Motor Rating AC-3 Duty, 415 Volts, 50 Hz , 3 Phase complete with Timer, suitable cap relay including dismantling unserviceable starter , complete all as specified and as directed. Make- L&T/Havells/Indoasian.
M&L Cement Concrete 1:4:8 type B-2 (40mm graded aggregate) in Foundations, Filling and Mass Concrete, etc., complete all as specified and as directed.
M&L Cement Concrete 1:3:6 type B-1 (20mm graded aggregate) in Foundations, Filling and Mass Concrete, etc., complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth without using extra cement, all as specified and directed.
Supply only Bleaching Powder conforming to IS-1065-199 (2nd Revision) minimum Markable Chlorine 33.5% by mass packed in 25.00 KILOGRAM HDFC Bag/Packing, ISI marked, complete all as specified. MAKE: AS APPROVED BY GE
S&F cast iron fittings/specials, Tee, collar, caps, plugs etc. of any shape and size with spigot & socketed, complete all as specified and as directed.
S & F of CI wheel arrangement complete with shaft and bearing of size as per Existing location for primary and secondary clarifier complete all as specified and as directed.
S & F only cast iron flanged pipe of 100 mm Dia,complete all as specified and as directed.
S & F only cast iron flanged pipe of 150 mm Dia,complete all as specified and as directed.
S & F of H-section 250 mm girdrer length 8 mtr approx with chain pulley capacity 3 ton arrangement for lifting of pump at sewage pump house.complete all as specified and as directed.
S & F of H-section 200 mm gidrer length 7 mtr approx for chain pulley arrangement for existing girder.for sewage pump house.
Supply of Jute rope min dia 25 mm suitable for lowering of pump set arrangement ate sewage pump house.complete all as specified and as directed.
Supply only Jute rope for lead joint of CI pipes/ gland packing complete all as specified and as directed by Engr-in-charge.
Supply only Rubber / EPDM gasket 4 mm thick complete all as specified and as directed by Engr-in-charge.
S & F stone aggregate upto size 20 mm for drain bed of sewage pump houseincluding removal of old agrregatecomplete all as specified and as directed by EIC.
S & F fine sand from Tezpur MARABHARALY for drain bed of sewage pump houseincluding removal of old sand.complete all as specified and as directed by EIC.
S & F MS studs for pump set of suiable size as per existing sample including removal of old stuts complete all as specified and as directed by EIC.
S & F MS Nut bolt with spring washer for pump set of suiable size as per existing sample nuts and bolts complete all as specified and as directed by EIC.
Satya Enterprises
M/S S.S.Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .