Executive Engineer
Executive Engineer Mechanical Division Agartala
Providing installation and commissioning of 1.5 2.0 TR capacity Split Type High Wall Air Conditioning Machines VRF and AHU unit in the Integrated Public Health Lab IPHL at Unakoti District Hospital Kailashahar during the year 2024-25
2024_CEPWD_54400_1
13_B_DNIeT_SE_IV_PWD RB_2024_25
Open Tender
Electrical Works
Works
120 days
Kailashahar
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹52,471
3 May 2025
5 Nov 2024
3 Dec 2024
5 Nov 2024
3 Dec 2024
5 Nov 2024
Amount
Providing ,installation & commissioning of horizontal floor mounted/ceiling suspended AHU with GI sheet metal cabinet type in double skin construction fabricated from extruded aluminium profile frame (thermal break) structure. The inner skin 0.6 mm thick GI Plain & Outer skin 0.6 mm thick GI sheets pre coated/powder coated construction with 45 mm thick CFC free PUF insulation(Density 40-42kg/cubic mtr.) with internal coving and in thermal break construction complete with following section with single mixing chamber with Pre-filter & Fine filter section, DX type cooling coil. 20 Micron filter-HDPE washable type, coil area 4.40 sq. ft. 6 coil rows,3/8'' ODx0.41mm thick seamless copper tubes,0.15 mm thick x 12-13 aluminium fins/inch,18 G.S.S drain pan with 10 mm thick insulation on outside, provided with return air & fresh air opening,3 kw GI electric tubular heater,3 phase,2 pole,415 v(+-10%),IP 55,TEFC sq. case induction Motor as per direction of the engineer-in-charge.( Make: ETHOS/Edgetech/Zeco, compatible with VRF Outdoor unit) i)Capacity:- 5.5 TR, 2200 CFM (Floor Mounted/ceiling suspended AHU) with 20% fresh Air.
Providing , Installation & commissioning of Variable Refrigerant Flow (VRF) System Outdoor units of AC machines minimum capacity of 14 HP or 11.2 TR each Top discharge, Modular type only cool, next generation VRF, each outdoor unit comprises of 100% inverter Driven Hermetically sealed Scroll Compressors , air cooled condenser with protective coated fins heat exchange corrosion fin factory coated propeller type fan with motor , specially designed ODUs with refrigerant cooled heat sink , non stop working at 56 degree C, with R410A or equivalent Refrigerant , working on 3 phase AC range of 380 volt to 420 (±5%)Volt, 50Hz , the outdoor unit should contain error code LED display for ease of operation, auto addressing setting refrigerant cool PCB, Electronic expansion Valve, microprocessor controller, VRF unit should be compatible with AHU/TFA etc. complete as per direction of the Engineer in charge.
Supply of AHU Kit for Connecting of AHU with MRV/VRF Outdoor AC as per design.
Providing, Installation & commissioning of Ventilation system comprises with 1000 CFM, 80 Static PR(mmwg), VUEX-FM type, 315 mm Dia fan, Minimum 52.7 % fan efficiency, 66.3 (aprox) dbA noise level, Out velocity 5.41m/s, 0.72 KW (+-), RPM 2527 (+-) 1.1 Kw motor (+-) , Filter area 500 Sq.feet installed in a insulated weather proof enclosure (3000 x1200 x 925) with pannel thickness 48 mm (+-) in/c intake suction, pre filter(MERV-8), Bag type fine Filter, (MERV-13), Motor(IE-2), Spring Isolator, Hepa Filter(MERV-17) etc. complete as per direction of the Engineer in charge.
Providing, Installation & commissioning of Variable frequency Device for speed controlling of Ventilation system etc. complete as per direction of the Engineer in charge..
Providing & Installation & commissioning of Room pressure Gauges for measuring of negative & positive pressure of the room etc. complete as per direction of the Engineer in charge.
Supply & fitting fixing of G.I. Cable Tray for laying of copper pipe support along with fittings as per required size 150mm etc complete as per direction of the Engineer in charge.
Supply, Installation & Testing of copper refrigerant piping for air conditioning system (Between indoor & Outdoor unit), shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including Nitrile Insulation tubes over refrigerant pipes including necessary supports to hang the copper pipes etc. complete as per direction of the Engineer in charge. 28.58 mm dia with 19 mm thick insulation or nearest diameter as per manufacturer design
22.2 mm dia with 19 mm thick insulation or nearest diameter as per manufacturer design.
19.1 mm dia with 19 mm thick insulation or nearest diameter as per manufacturer design.
15.9 mm dia with 13 mm thick insulation or nearest diameter as per manufacturer design.
12.7 mm dia with 13 mm thick insulation or nearest diameter as per manufacturer design.
9.5 mm dia with 13 mm thick insulation or nearest diameter as per manufacturer design.
Supply & installation testing of PVC pipe (for drainage of water from IDU) with 6 mm thick Nitrale Rubber insulation ) Drain pipe 25 mm with 6 mm thick Nitrale Rubber insulation
Supply & laying of copper conductor schedule flexible communication cabling between ODU and IDU as per OEM specification (VRF) cable shall be lying through hard PVC conduit pipe etc complete as per direction of he engineer-in charge. i) 2 Core x 1.0 ~ 1.5 Sq.mm
Providing & connecting Electric control cables between indoor & outdoor, Machine room Supply point to indoor machine suitable cable for 3-phase line in/c Neutral etc complete as per direction of the Engineer in charge.
Supply & erection of GI Ducting complete as per direction of the Engineer in charge. 22G GSS Sheet
Supply & erection of GI Ducting complete as per direction of the Engineer in charge. 24G GSS Sheet
Supply & erection of Thermal insulation with 13 mm thick Nitrale with aluminum foel complete as per direction of the Engineer in charge.
Supply & erection Canvas connection complete as per direction of the Engineer in charge.
Providing & installation Outdoor structure or CC Pedestal complete as per direction of the Engineer in charge.
Providing & Installation Grilles/Diffusers complete as per direction of the Engineer in charge.
Supply & erection duct dampers (Manual GI material) complete as per direction of the Engineer in charge.
Supply & erection of inside Duct acoustic insulation with 10 mm thick (Class -1 Accosound) Nitrale with perforated aluminium sheet complete as per direction of the Engineer in charge.
Supply & Charging of R-410A Refrigerants Gas etc complete as per shop drawings and specifications and as per direction of the Engineer-in-Charge.
Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 1.50 TR (4,500 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge.
Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 2.00 TR (6,000 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge.
Standard installation of 1.5 TR/2.00 TR capacity Hi-Wall Split type type Air Conditioner in/c repairing of drilled wall by cement mortar, painting in/c necessary insulation, clamping and warping by white masking tape of copper pipes, and also providing electrical 3 pin 16 amp Top for connection in socket & necessary scaffolding etc. complete as per direction of the Engineer-in-Charge.
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge.
Providing and fitting fixing of copper pipe (suction & discharge) for split AC (5/8'',1/4'') suitable size as per direction of the Engineer-in-Charge.
Providing and connecting Electric Control cables between indoor unit and outdoor unit beyond standard quantity kit. 3C X 2.5 Sq. mm Copper Cable.
Providing hard PVC pipe of good quality of at least 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_55269.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .