Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹29.6 L+₹45,699.06 (1.57%)Rejected-Finance DOOR NO 10 89 BC COLONY PAPAYYARAJUPALEM SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹30.3 L+₹1.2 L (4.05%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹30.8 L+₹1.7 L (5.68%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹31.5 L+₹2.3 L (7.91%)Rejected-Finance 24 85 7 SANATH NAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L5 | Rejected-Finance Rejected |
Tender Value
₹28.7 L
EMD Value
₹57,400
Closing Date
13 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVISION OF CERTAIN MINOR AND REVENUE WORKS UNDER AGE BR I OF GE ND VISAKHAPATNAM
2024_MES_659463_1
8370/GEND/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE ND VISAKHAPATNAM
₹57,400
Yes
17 Oct 2024
13 Jun 2024
15 Jul 2024
13 Jun 2024
13 Jul 2024
5 Jul 2024
Amount
SCHEDULE 'A' PART-I : B/R WORKS
Surface excavation n.exc 30cm and averaging 15cm deep and getting out in soft/loose soil
Removing excavated soils exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point
Supply and planting Korean/Mexican carpet grass by piece turffing over the prepared base including watering, removing the weeds or any other vegetation, mixing the manure from time to time as required complete all as specified and directed. Note :- (i) Supply only loose soil, cow dung and vermi compost shall be measured and paid separately.
Supply only approved sweet earth/loose soil best quality for plantation all as specified and directed.
Supply only approved manure (Cow dung) best quality all as specified and directed.
Supply only approved vermi compost of best quality all as specified and directed.
Supply, plantation and developing of Hedging of 300mm wide and 300mm height with hedge plants as approved by GE, evergreen species including proparation of ground up to 0.40m deep and of width 0.40m and filling of Good Earth (Without Moorum content) and having suitable PH and EC as recommended for Saline Water conditions etc (3 parts) and Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. (1 part) and watering etc. and applying Soil Pesticide, transplanting of Hedge Plants including cost of Good Earth, Manure, Pesticides, etc complete all as specified and as directed.
S&F 25 mm bore Galvanized Steel tubes, medium grade for water supply pipes etc., fixed to walls and ceilings or laid in floors
S&F 25mm dia Garden Sprinkler valve swivel type brass body, ISI marked, screwed both ends for iron pipe complete all as specified and as directed.
S&F Angle cock, 15mm dia, cast copper alloy with capstan head, Chromium Plated, screwed down high pressure with crutch or butterly handle for iron pipe etc. complete all as per Jaquar Catalogue No. CON-059KN or its equivalent in Kohler/Grohe/ROCA
M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6
M&L for granite 18 to 20 mm thick (of any type) tiles, machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture or pigment to match the shade of granite stone including grinding and polishing , moulding edges as directed and making hole for gas pipe if required complete including 15mm thick rendering in CM (1:3) as backing coat upto 12th floor
M&L cement concrete type C1 ,1:3:6 ( using 20 mm graded stone aggregate) 75mm thick as in plinth protection,path etc finished the surface even and fair w/o using extra cement complete all as specified and directed.
M&L for coloured designed chequered cement concrete tiles of any size and 22 to 25 mm thick with mixture of white & grey cement in equal proportions and no pigment as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed of 15mm thick in cement mortar 1:6 complete all as specified and directed.
Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed
Demolition of Reinforced Cement Concrete of Column, beams etc.
Demolition of brick work built in cement mortar including all quoins, pillars etc
Removing of debris to out side the premises to a distance of 1.00 KM all as directed by Engineer in Charge.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in Hard/dense soil including removing grass/plants girth n exc 30 cm etc all as specified and directed
Excavating in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foudation etc or fo shafts wells, cesspits manholes pier holes etc n.exc 10Sqm on plan and n.exc 1.50m in depth and getting out in soft /loose soil
Returning filling in , including spreading levelling watering and well ramming in layers not exc 25cm in soft /loose soil
Removing excavated soil material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting oint.
M&L Treating the Soil under plinth protection @5ltr/sqm emulsion per sqm of surface area
M&L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
M&L PCC 1:4:8 type D2 (40mm graded stone aggregate) as in foundation filling and mass concrete.
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces
M&L RCC 1:1/2:3 type A1 using (20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc.,
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions
M&L RCC 1:1/2:3 type A1 using (20mm graded aggregate) as in Columns, pillars, piers, posts and struts etc.,
Use and waste of Form work to to sides and soffits of floor or roof beams and lintels for fair finished surfaces
M&L RCC 1:1/2:3 type A1 using (20mm graded aggregate) as in beams ,Cantilvers bressumers lintels over 1.5m span
Use and waste of Form work to soffits of suspended slabs such as roof slabs ,floor slab, landings and similar work;not exc 200mm thick (horizontal or slopping) for fair finished concrete surfaces
M&L RCC 1:1/2:3 type A1 using (20mm graded aggregate) as in slabs supported on walls beams and columns in floors roofs landings balconies canopies deck slabs and shelves etc..
Use and waste of Form work to chajjas,troughs and chullahoods and similar items including edges for fair finished surfaces.
M&L RCC(1:1.5:3) tye A1 using (20mm graded aggregate) as in Chajjas
S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally or hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc.
Ditto but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders
Rendering,10 mm for internal plaster on brick / concrete surfaces, in CM 1:6 finished even and smooth without using extra cement.
Rendering 5 mm thick plaster on concrete surfaces, in CM 1:4 on ceiling finished even and smooth without using extra cement.
Rendering 15mm thick, Externally 5 mm in CM (1:4),over 10 mm 1:6, on brick/ Concrete surfaces with water proofing compound. finished fair and even. Note: WPC will be measured and paid seperately.
Supply only WPC.
S & F 2nd class HW Transomes or mullions, straight, for solid frames of any description, wrought, framed, double rebated on the solid, rounded or chamfered (including weathering to transome, if required put together with glue, pinned at joints)
S & F 35 mm thick Second class hard wood plain, framed, panelled shutters (any number of panels), with panels of veneered particle board or plywood or bison board.
M&L Preparation of new or previously un treated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of pink primer.
S&F 200mm long aluminium, anodised barrel tower bolts of extruded section, all as specified and as directed by the Engr-in-charge.
S/F aluminium alloy anodised sliding door bolt 300mm long with hasp staple (bolt type) and fixing clips of sheet bast or ext4ruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy as Specified.
S&F 150mm Extruded aluminium alloy handle all as specified and as directed by the Engr-in-charge.
S/F butt hinges 100mm size exturded Alu. alloy with galvanised mild steel hinge pin anodised and fixed Cl type B-22 all as Specified and directed.
S&F powder coated aluminium anodised frames for doors , windows , ventilators, cupboard etc with one or more rebates including jointing jointing cleats for fixing etc, complete all as specified and directed.
S&F powder coated aluminium anodised windows and ventilator shutters fixed / sliding type without sash bars , aluminium section weighing 0.55kg / m including necessary joining cleats, glazing clips ,rubber neoprene packing , handles 02 nos in each doors hinges anodised , aluminium snap beading screwed etc complete all as specified and directed.
S&F 5.50 mm thick frosted sheet glass glazing with oil putty in squarre / rectangular quality complete all as specified and directed by Engineer-in-Charge.
Aluminium anodised grill anodised transparent or dyed to required shade according to IS :1868 with minimum anodic coating of grade AC15 ) of approved design / pattern with approved standerd sectionh and fixed to the existing windows frame With CP brass / stainless steel screw @ 200mm centre to centre , including cutting the grill to proper opening size for fixing and operational of handles and fixing approved anodised aluminium standared section around the opening all complete as requirement and directed by Engr - In - Charge
M& L for Brushing neat cement slurry with 3 kg of cement per sqm and applying 15mm thick in CM (1:3) screed bed on slab with 2% of water proofing compound, Polymer modified bituminous membrane with sand witched polythene film/non woven polyster reinforcement /polymeric water proofing membrane 3Kg/sqm plastifelt/hyperplas /multiplas / shivam or equivalent ) laid over hot blown grade85/25@ 1.2kg/Sqm (i.e roof slab cleaned throughly to to remove all loose particle dust/dirt particle ) shall be laid over entire roof surface and on verticle surface up to grooves ( or as per manufacturers recommendation) with over laps of 100mm The over lap shall be sealed by flames or as per manufacturer instruction.Hot blown bitumen grade 85/25 @1.2kg/Sqm applied over the membrane and one coat of bituminous aluminium [email protected] Kg/Sqm applied on treated bituminous membrane should be compatible with membrane all as recommendation manufacturers and all as specified and directed
M&L Hardcore of gauge exc 63mm but n.exc 100 mm , deposited , spread and levelled in layers n exc. 15 cm thick , watered and rolled/ rammed to a true surface.
M & L PCC 1 : 4 :8 type D2 (40 mm graded stone aggregate) as in sub base 100 mm thick
M&L 25 mm thick PCC(1:2:4) type B1 using 20mm graded aggregate as in sub base all as specified.
M&L 75mm thick PCC(1:3:6)type C2 (40mm graded stone aggregate as in plinth protection laid in alternative panels
S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls
S&F 110 mm bore PVC (SWR) bends of any radius with access door
M & L preparing surfaces plastered or unplastered new surfaces of ceiling applying three coat of white wash to ceiling surfaces
M&L preparing plastered or unplastered new wall surfaces applying two coats of oil Bound distemper over a coat of chalk whitening all as specified and directed.
M&L for applying two or more coats of 100% premium acrylic emulsion paints having VOC less than 50 gm / ltrs and UV resistance asper IS-15489 -2004 , Alkali and fungal resistance dirt resistance exterior paint of required shade (company depot Tinted) with silicon additives @ 1.43 / 10sqm over and including priming coat of exterior primer applied @ 0.90 ltrs / 10 sqm over new surfaces all as specified and directed.
Supply and planting Artificial / Natural Plants for vertical garden in many varieties as per directed by Engr in charge including necessary provisions complete all as specified and directed.
Shrubs Digging of pits 60x60cm refiling with good soil and organic manure , supply and planting of healthy and grown plants with good root system of minium height three feet at the time of planting from the ground level maintance for aperiod of two months watering , deweeding loosening of soil , manuring with manure neem cake , pruning and spraying of insecticides and when required. Ashoka Plant upto 10 feet height
Supply and planting of Indoor plants like (Peach Lilly, defonbekia, Aglonima, Golden money plant, Fern all varieties 1 to 2 inch hight) Bushy Plants all as specified and directed by Engr in charge.
Taking up or down 15mm dia steel tubing connections, including cleaning for re-fixing or removal to store.
Taking up or down 20mm dia steel tubing connections, including cleaning for re-fixing or removal to store.
S&F 3-layer PP-R P o l y p r o p y l e n e random copolymer) pipes 15 mm dia SDR 7.4 & SDR 11 UV stablised laid & concealed in walls including bends, elbows, unions etc, laid on walls for vertical stacks including chasing the wall and making good complete all as (Make: SFMC PN16/SDR7.4)
S&F 3-layer PP-R P o l y p r o p y l e n e random copolymer) pipes 20 mm dia SDR 7.4 & SDR 11 UV stablised laid & concealed in walls including bends, elbows, unions etc, laid on walls for vertical stacks including chasing the wall and making good complete all as (Make: SFMC PN16/SDR7.4)
S/F PP-R Gate valves (brass insert) of 20mm dia with iron wheel head screwed both ends for iron pipe and fixed etc .
Making connection of PP-R distribution branch with PP-R main of 15/20 mmg sizes by providing and fixing tee including cutting and making fusion joint etc.
Rotational moulded polye thylene 3 layers LDPE 1000 ltr water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed (Make : SYNTEX/ORIPLAST/PLASTO)
S&F 20mm ball brass valves,high pressure,with polythane float and flynut complete,screwed for iron pipe or brass ferrule .
PCC 1:2:4 type B2 (40mm graded agg) 75mm thick as in paving/hard standing.
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 - 2006 of 60 mm thickness, M - 35 Grade with grey cement and pigment.
M & L for Sand filling in floors or in foundations including watering and consolidation for screed bed as per directed.
M&L for PCC type B1 (1:2:4 )(using 20 mm graded stone aggregate) as in roof kerb , coping, benching ,coving rounded or chamfered edges,hold fast block, , etc complete as directed.
Dismantling AC sheet ( corrugated , semicorrugated etc.) in roof coverings.
Taking down wooden roof trusses , coupled rafters or trussed beams upto 4 metre clear span..
Taking down wooden choukhat with shutters without taking off shutters from the frame exceeding 1.5 Sqm but n.exc 4 Sqm each.
SCHEDULE 'A' PART-I : E/M WORKS
M&L for point wiring with 1.5sqmm PVC insulated sheathed multistranded copper cable of FRLS grade with one run of 1.5 sqmm PVC insulated copper cable as earth continuity drawn in ERW metallic steel conduit not less than 20mm dia and including all accessories (but excluding junction boxes) complete all as specified and directed.
S&F Flame Proof Switch rotary type with termination box in LM6 16A single pole 250 V complete all as specified and directed.
S&F Flame Proof Exhaust Fan size 450mm, 1440 rpm, Cat No. EF 140 fo Sudhir or it's equivalent from Shyam/Baliga.(Note: Cutting the existing wall to making hole to fix Exhaust fan will measured and paid separately) complete all as specified and directed.
Supply and fix MCB DB SPN 4 Way, 240 Volt with 200 Amps rated bus bar, double door complete all as specified and directed.
Supply and fix MCB SPN 40A 230 Volt, Breaking capacity 10KA 'B' Curve complete all as specified and directed.
Supply and fix MCB SP 6-32A, 230 Volt, Breaking capacity 10KA, 'C' Curve complete all as specified and directed.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of HA & 111B, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Cutting the existing stone masonry wall for fixing the Exhaust fan including plastering with cement plaster and making good surfaces .
S & F Building Security light LED type of minimum 3000 Lumens (30 Watt) Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 Core.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with Galvanize earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type Cl chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and laying in trenches bricks common burnt clay building brick , sub class B designation 75 complete all as specified & directed
Supply and laying GI tubing light grade 40mm in trenches complete all as specified & directed by Engr in charge
Supply and fixing flame proof junction box complete all as specified & directed by Engr in charge
M/s KAMADHENU ENGINEERING CONSTRUCTIONS
M/s SIRI CONSTRUCTIONS
NAVEEN INFRASTRUCTURES
V R K CONSTRUCTIONS
prasad constructions
SRI DHANESWARI ENGINEERING WORKS
BHARATHI ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .