Tender Value
₹31.1 L
EMD Value
₹62,100
Closing Date
31 Aug 2026, 3:00 pm2d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
13 conditions · 2 needing a document upload
Not Applicable, since the tender value is less than 50 lakh
Since the tender value is less than 50 lakh, no eligibility criteria have been prescribed. However, bidders participating in this tender shall upload/Submit a certificate/document, duly authenticated by the concerned Railway Authority, confirming that the firm has successfully executed signalling works of a similar nature in the Railways during the last seven years. Failing submission of the certificate/document, the offer shall be rejected
27 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit full Bid Security and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract for works 2022, with all correction slips up-to-date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We offer to do the work for DRM/S&T/TVC, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within the period of completion stipulated in the tender document, from the date of issue of letter of acceptance of the tender. The amount as stipulated in the tender document is herewith forwarded as Bid Security. Full value of the bid security shall stand forfeited without prejudice to any other right or remedies in case my/our Tender is accepted and if : (a) I/We do not execute the contract documents as stipulated in performance guarantee clause of GCC for works 2022 as detailed in general instructions. (b) I/We do not commence the work within seven days after receipt of orders to that effect.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of Bid Security and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
INSTRUCTIONS TO TENDERERS
The tenderer shall thoroughly go through the entire tender documents and strictly adhere the instructions and directions given at different pages.
Tender Document Cost for this work is Nil.
Unreleased Bid Security, if any, held with the Railway Administration, shall not be adjusted towards the Bid security to be remitted.
If the Tenderer(s) deliberately give(s) wrong information/ incorrect documents in his/their tender or create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage. The entire Bid Security and any other dues available with Railway against that contract will be forfeited. Action will be taken to suspend the business with the tenderer for a period of two years. In addition, Administration reserves the right to prosecute under suitable law.
All terms and conditions in the tender documents are binding on the Tenderers.
Railways reserves the right to accept or reject any or all the tenders and to award the work in whole or in part without assigning the reason for any such action.
The Tenderers are advised to visit the site of work in their own interest and acquaint themselves with the site conditions and expected quantum of work and assess all the site specific difficulties to be experienced while executing the same and the rate shall be arrived duly considering all the facts above and quoted in the tender. Any representation at a later date specifying the site difficulties shall not be considered.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. If the bidding unit is Above/ Below/ Par, the bidder can select the %Above, %Below or %At Par option from the drop down list in the same column. If the bidding rate is Rs. or Rs./ unit, the bidder has to quote his rate for the item group or individual item accordingly
All the bidders/tenders should ensure that they are GST compliant and their quoted tax structure/rates are as per GST Law
In case of any wrong information submitted by tenderer, the contract shall be terminated, Bid security, Performance Guarantee(PG) and Security Deposit(SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 2(Two) years
Provision of S&T arrangements in connection with provision of Track Machine Siding at KOLLAM stations of TVC division.
TVC-SNT-SIG-26-27-11~SR
TVC-SNT-SIG-26-27-11
Open
Works - General
6 Months
Thiruvananthapuram, Kerala
₹0
₹62,100
5 Aug 2026
5 Aug 2026
17 Aug 2026
68 items across 1 schedule · ₹26,68,551.87 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 110.00 | 382.12 | 42,033.2 |
| 2 | Supply of indicative type Surge Protection Device as per RDSO Spec. No. SPN/165/ 2023, Version 4.0 Amdt.1 or latest (Lightning and Transient surge protection for power line). The system shall have stage1 (class B) and stage 2 (class C) type against Lightning electromagnetic Impulse configuration. The protection of Type 1 and 2 against Lightning electromagnetic Impulse (LEMP) and other high surge, shall be provided at the incoming of the power line at the stations, LC gates before the power equipment's as per the instructions of Engineer in-charge at site. Supply of surge protection with Potential free contacts shall be of approved make like OBO, DEHN, PHOENIX, LPT or better make. All other miscellaneous materials required for the work shall be supplied by the contractor. (as per Technical Specification enclosed) | Numbers | 3.00 | 22,756.39 | 68,269.17 |
| 3 | Supply and Provision o f Earthing a s per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed) | Numbers | 7.00 | 28,118.51 | 1,96,829.57 |
| 4 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 20.00 | 1,707.55 | 34,151 |
| 5 | "Installation of 230V Class B & Class C Surge Protection Device. This includes transportation of materials to site. Installation to be carried out a s p e r the direction o f R a i l w a y Engineer. Necessary copper wire for Power Wiring and connecting the earth t o b e supplied a s part of the schedule. All other miscellaneous materials required for installation shall be supplied by the contractor." | Numbers | 3.00 | 9,752.74 | 29,258.22 |
| 6 | Supply o f Low maintenance secondary cells of t h e f o l l o w i n g c a p a c i t i e s w i t h necessary i n s p e c t i o n a s p e r specification/ drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V-80AH capacity | Numbers | 35.00 | 3,379.2 | 1,18,272 |
| 7 | Supply of track feed battery charger IRS:S 89- 2013 | Numbers | 10.00 | 4,375.25 | 43,752.5 |
| 8 | Supply of 'B type choke IRS:S 65-83 | Numbers | 9.00 | 2,855.6 | 25,700.4 |
| 9 | S u p p l y a n d provision o f n o r m a l j o i n t using Thermo s h r i n k jointing k i t ( R D S O s p e c s No TC/77/2012 ( Rev.3) with amendment No.1&2 or latest.& jointing kit to be inspected by RDSO) for 4/6 quad cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing the same after completion o f cable j o i n t a s p e r t h e instruction o f Railway representative at site. | Numbers | 24.00 | 4,628.91 | 1,11,093.84 |
| 10 | S u p p l y a n d p r o v i s i o n o f d e r i v a t i o n joint complete for 6 Quad cables using thermoshrink jointing kit for LC's/stations | Numbers | 4.00 | 4,901.27 | 19,605.08 |
| 11 | S u p p l y a n d installation o f 2 4 F i b r e Joint enclosure f o r armoured o p t i c a l fi b r e cable c o n f o r m i n g t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers | 4.00 | 13,647.37 | 54,589.48 |
| 12 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as per t h e instructions o f Railway representative at site.) as per drawing enclosed | Numbers | 60.00 | 262.65 | 15,759 |
| 13 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 1000.00 | 64.1 | 64,100 |
| 14 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives a t s i t e . (Laying of cables is not included in this schedule). | Metre | 60.00 | 314.41 | 18,864.6 |
| 15 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by r a m m i n g a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / R C C p i p e s . During excavation of trench, it has t o b e ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from t h e b o t t o m o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 60.00 | 385.45 | 23,127 |
| 16 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes w ith couplers/collars is not included in this schedule). | Metre | 18.00 | 501.03 | 9,018.54 |
| 17 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 42.00 | 208.54 | 8,758.68 |
| 18 | Laying o f signaling/power/ telecommunication cables a s p e r c a b l e plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 8000.00 | 18.18 | 1,45,440 |
| 19 | Placing of one row of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 1000.00 | 62.99 | 62,990 |
| 20 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 1000.00 | 15.4 | 15,400 |
| 21 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of the f o u n d a t i o n a n d r e fi l l i n g t h e p i t and consolidating it by ramming. The cable markers shall b e provided a t a n interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout t h e cable route, diversions and also at every track/road crossing." | Numbers | 60.00 | 123.35 | 7,401 |
| 22 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables and placing closely one layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 10.00 | 949.05 | 9,490.5 |
| 23 | B l o w i n g / D r a w i n g o f O F C cable/Power cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid l u b r i c a t e d H D P E p i p e . ( This includes Transportation o f materials from nominated stores to site) | Metre | 1000.00 | 23.43 | 23,430 |
| 24 | Supply of subsidiary Signal Aspect - Shunt LED a s p e r RDSO Specification SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 21.00 | 5,740.7 | 1,20,554.7 |
| 25 | Manufacture a n d supply o f Enameled Number plates as per drawing No.TY/08/2008 with fixing arrangements and fixing them o n t h e existing Signa ls a s per the instructions of Railway representative at site.[Enameled number plates w ith fixing arrangements w ith bolts a n d nuts shall be supplied by the Contractor]. | Numbers | 9.00 | 305.25 | 2,747.25 |
| 26 | Supply o f Colour light Signal pole 140mm dia, 4.6m/ 3 .6 m tall w ith necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of colour light Signal pole 4.6m tall and 140 mm dia(Galvanised) | Numbers | 2.00 | 5,841 | 11,682 |
| 27 | Supply o f surface base t o suit C L S Signal pole 140mm d i a w ith necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 2.00 | 6,814.5 | 13,629 |
| 28 | Supply of ladder with platform and shoes to suit C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary i n s p e c t i o n a s p e r specification/ drawing/ description enclosed in this document. a)Supply o f l a d d e r w i t h p l a t f o r m ( 4 . 6 m ) for CLS(Galvanised) | Numbers | 2.00 | 5,698 | 11,396 |
| 29 | Supply of Ground type shunt signal - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 1.00 | 7,463.5 | 7,463.5 |
| 30 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire P V C copper, 3 / 0 . 7 5 m m and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , f o r fi x i n g resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, c o n d e n s e r s a n d a l l other miscellaneous materials r e q u i r e d f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 1.00 | 4,945.51 | 4,945.51 |
| 31 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire P V C copper, 3 / 0 . 7 5 m m and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , f o r fi x i n g resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, c o n d e n s e r s a n d a l l other miscellaneous materials r e q u i r e d f o r the work shall be supplied by the contractor]. b)Wiring o f Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set | 3.00 | 8,786.26 | 26,358.78 |
| 32 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire P V C copper, 3 / 0 . 7 5 m m and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , f o r fi x i n g resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, c o n d e n s e r s a n d a l l other miscellaneous materials r e q u i r e d f o r the work shall be supplied by the contractor]. c)Wiring o f Signal/ Point/ LC control circuit (up to 12 relays/plug in type) | Set | 1.00 | 11,355.02 | 11,355.02 |
| 33 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire P V C copper, 3 / 0 . 7 5 m m and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , f o r fi x i n g resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, c o n d e n s e r s a n d a l l other miscellaneous materials r e q u i r e d f o r the work shall be supplied by the contractor]. d)Wiring o f Signal/ Point/ LC control circuit (up to 20 relays/Plug in type) | Set | 4.00 | 13,597.41 | 54,389.64 |
| 34 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers | 3.00 | 15,009.6 | 45,028.8 |
| 35 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e clam ps, 25mmx 100mm f o r base planks, phynolic sheet 6mm t h i c k o f size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 250.00 | 167.99 | 41,997.5 |
| 36 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e clam ps, 25mmx 100mm f o r base planks, phynolic sheet 6mm t h i c k o f size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 30.00 | 201.27 | 6,038.1 |
| 37 | Fi x i n g o f additional p l u g b o a r d s , 5 0 ways terminal blocks and wiring o f additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be p r o v i d e d w h e r e v e r required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips a n d 50 w a y terminal boards i s n o t covered i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors a n d condensers, soldering materials, b u n c h i n g t h r e a d , w i r e wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneousmaterials required f o r the work shall be supplied by the Contractor ] | Per Relay | 48.00 | 726.5 | 34,872 |
| 38 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e w ork includes painting alterations a n d releasing the unwanted wires carefully without disturbing the existing wiring. [ W i r e P V C 1 6 / 0 . 2 m m c o p p e r , soldering m a t e r i a l s , b u n c h i n g t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r t h e w o r k s h a l l b e s u p p l i e d by the Contractor]. | Per Relay | 74.00 | 695.67 | 51,479.58 |
| 39 | S u p p l y o f D o u b l e w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming t o specification N o . IS 14930(Part 2): 2001 with one coupler for every 6m o f pipe as per Technical specification | Metre | 340.00 | 365.19 | 1,24,164.6 |
| 40 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 42.00 | 1,119.16 | 47,004.72 |
| 41 | Supply o f HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers | Metre | 1000.00 | 60.93 | 60,930 |
| 42 | Supply of Track Feed Resistance | Numbers | 5.00 | 287.77 | 1,438.85 |
| 43 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 3750.00 | 61.44 | 2,30,400 |
| 44 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 420.00 | 93.02 | 39,068.4 |
| 45 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 220.00 | 103.84 | 22,844.8 |
| 46 | Excavation of pit, erection o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawl of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red- oxide and two coats of aluminium paints. | Numbers | 3.00 | 5,029.69 | 15,089.07 |
| 47 | Installation of combined type point machine-IRS t y p e a n d connecting a l l ground connections including wiring and termination in point machine a n d interconnections between point machine and CT box through PVC h o s e pipe with 3/0.75mm and 7/1.40mm copper wire and p a in t in g . This work i n c l u d e s p r o v i s i o n of insulation to stretcher bars, throw bar l u g and "D" bracket wherever required, c u t t i n g of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]. | Numbers | 2.00 | 16,383.88 | 32,767.76 |
| 48 | Excavation of pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly o f size 20/25mm d i a a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 1.00 | 9,213.28 | 9,213.28 |
| 49 | "Excavation o f p i t a n d c a s t i n g concrete foundation a s p e r Drg, No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone j e l l y o f size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 1.00 | 4,645.17 | 4,645.17 |
| 50 | "Erection of Ground type shunt signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever i s applicable), fixing o f lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision o f E W S locks and painting o f o n e coat o f red o x i d e and two c o a t s o f Aluminium/ enamel paint.(Supply o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n this schedule).[Wire PVC 3/0.75mm coppe r, l e n s guards, E W S locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." | Numbers | 1.00 | 3,170.44 | 3,170.44 |
| 51 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers | 2.00 | 7,145.44 | 14,290.88 |
| 52 | Alteration t o existing D C Track Circuits to suit RE/Non RE standard a s per approved signaling plan. T h i s w o r k includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration t o existing track circuits at feed end | Numbers | 1.00 | 4,234.65 | 4,234.65 |
| 53 | Excavation o f pit, casting concrete foundation and erection o f apparatus case full size a s per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation b o l t s & n u t s , ' E ' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fi x i n g b o l t s & n u t s a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 6.00 | 11,333.1 | 67,998.6 |
| 54 | "Excavation o f pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & n u t s a n d a l l o t h e r miscellaneous materials required for the work shall b e supplied by the Contractor]""" | Numbers | 4.00 | 8,787.04 | 35,148.16 |
| 55 | Excavation of pit, erection o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e f o r cable throughing, fi x i n g of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e c o a t of red-oxide a n d t w o c o a t s of aluminium paints.(Supply o f C T boxes i s not covered i n this schedule. R a i l s o f different l e n g t h s h a l l be supplied b y Railways. The contractor shall cut lengthy rails wherever required.)[Cement, M sand, stone jelly o f size 20/25mm, paint, varnish, G I Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts a n d nuts with washers, EWS l o c k s , p a i n t s a n d a l l other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 2.00 | 4,999.16 | 9,998.32 |
| 56 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils to g i v e a c c e s s for shifting/turning t h e location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative a t s i t e . I f the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. a) Shifting of apparatus case (full) | Numbers | 5.00 | 5,348.81 | 26,744.05 |
| 57 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils to g i v e a c c e s s for shifting/turning t h e location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative a t s i t e . I f the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half) | Numbers | 4.00 | 3,545.06 | 14,180.24 |
| 58 | Termination o f n e w main/tail c a b l e s o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r a p p r o v e d circuit diagram. T h e terminal particulars a r e to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w o r k includes closing t h e opening created f o r entry o f new cables i n the apparatus cases w i t h masonry b r i c k work and sealing t h e b o t t o m o f the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 425.00 | 73.59 | 31,275.75 |
| 59 | Termination o f main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d the bottom surface shall b e sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." a)Termination on 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 700.00 | 172.14 | 1,20,498 |
| 60 | Termination o f main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d the bottom surface shall b e sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 40.00 | 209.93 | 8,397.2 |
| 61 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, t h e side openings o f apparatus case foundation shall b e closed w ith brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. a)Termination o f c a b l e s on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 400.00 | 151.09 | 60,436 |
| 62 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, t h e side openings o f apparatus case foundation shall b e closed w ith brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. b)Termination of cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 25.00 | 188.86 | 4,721.5 |
| 63 | Carrying out alterations to the existing SM's control panel. The work includes drilling of holes on the Top plate wherever required, fixing and wiring o f knobs, buttons, counters, LED s with holder, closing of unwanted holes, carrying out painting alterations on the panel, termination of additional cables and carrying out alteration to the existing wiring as per approved circuit d i a g r a m , r e le a s in g o f u n u s e d w i r e s , and painting of particulars as per the instructions of Railway representative at site.(Supply of knobs, buttons a n d counters is not included in the scope of this schedule). [LED lamps with holder, p a i n t , soldering materials a n d a l l other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]. | Lumpsum | 1.00 | 15,967.35 | 15,967.35 |
| 64 | Provision of HDPE Pipe of dia 40/33 mm | Metre | 1000.00 | 26.11 | 26,110 |
| 65 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly a t a p l a c e a s i n s t r u c t e d b y Railway representative at site. Also the resultant pits s h a l l b e re-surfaced a n d consolidating by ramming and levelling" | Numbers | 1.00 | 1,580.36 | 1,580.36 |
| 66 | Releasing of existing apparatus cases (Full/ Half/ Quarter size) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f a l l t y p e s EKTs, Secondary Cells, power equipments, ' E ' type l o c k s , e t c . , and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming a n d levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site. | Numbers | 12.00 | 3,006.71 | 36,080.52 |
| 67 | Breaking of concrete and releasing the existing c a b l e termination boxes, after releasing the b a s e p l a n k , Terminal blocks, Fuse Blocks, Terminal Boards, c u t rails, pipes, etc., closing t h e resultant p i t s and consolidating i t by ramming and levelling. The released materials shall b e accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 3.00 | 2,004.94 | 6,014.82 |
| 68 | Releasing of existing TLD boxes with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 18.00 | 159.29 | 2,867.22 |
| Schedule total | ₹26,68,551.87 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022.pdf
ATTACHMENT
GCCCorrectionslip1-5.pdf
ATTACHMENT
GCCCorrectionslip6-11.pdf
ATTACHMENT
SOR2022BOOKLET.pdf
ATTACHMENT
ATCandScopeofwork.pdf
ATTACHMENT
LetterPoliceVerification.pdf
ATTACHMENT
CableCutpenaltyLetter.pdf
ATTACHMENT
ModelformofBankGuarantee.pdf Model form of Bank Guarantee
ATTACHMENT
ModelformofBankGuarantee.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].