EE PHED DN Hanumangarh
EE PHED DN Hanumangarh
Proposal for repairing work of electric starter panel board, lighting and replacement of defective electric parts at various water supply schemes under sub division Pilibangan
2026_PHCJA_582481_10
EE/PHED/HMH/2026-27/19-43
Open Tender
Repair and Maintenance Works
Percentage
300 days
Aen PHED Sub division Pilibagan
As per Tender document
2 documents required · 2 mandatory
₹500
EE PHED DN Hanumangarh
₹3,620
Yes
EE PHED DN Hanumangarh
20 Aug 2026
5 Aug 2026
21 Aug 2026
5 Aug 2026
20 Aug 2026
5 Aug 2026
19 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Repairing work of electric starter panel board lighting & replacement of defective electric parts at various water supply schemes under sub division Pilibangan | |||||
| 1.01 | Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/ openwell including cost of insulation tape etc.. | 60 | each | 518 | ₹31,080 |
| 1.02 | Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department | 28 | each | 280 | ₹7,840 |
| 1.03 | Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) | - | - | - | - |
| 1.04 | 5 to 15 HP. | 35 | each | 371 | ₹12,985 |
| 1.05 | 16 to 30 HP. | 30 | each | 432 | ₹12,960 |
| 1.06 | 31 to 60 HP. | 10 | each | 468 | ₹4,680 |
| 1.07 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 1.08 | 3 pole MCCB With Thermal Magnetic release | - | - | - | - |
| 1.09 | 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, | 4 | Each | 9,961 | ₹39,844 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
TD_28.pdf
Tender Documents • 1.28 MB
BOQ_1034987.xls
BOQ • 0.29 MB
officeorder.pdf
PDF • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .