Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹41.0 L+₹1.8 L (4.52%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹42.7 L+₹3.4 L (8.79%)Rejected-Finance 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹43.5 L+₹4.2 L (10.8%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹43.9 L+₹4.7 L (12.0%)Rejected-Finance PLOT NO 127 3 A RATNASAGAR FLATS SECTOR 19 GANDHINAGAR 382019 | GANDHINAGAR | GANDHINAGAR | GUJARAT | 382019 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
22 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Chiloda
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
OUT SOURCING OF SERVICES FOR OPERATION OF LIFT INCLUDING COMPREHENSIVE REPAIR AND MAINTENANCE OF LIFTS IN MD ACCN AT VSN GANDHINAGAR
2022_MES_539995_1
82123/CHL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GANDHINAGAR
As per tender document
6 documents required · 6 mandatory
₹500
GE (AF) CHILODA
₹1 L
Yes
1 Sept 2022
22 Jul 2022
29 Aug 2022
22 Jul 2022
22 Aug 2022
8 Aug 2022
23 Jul 2022 - 7 Aug 2022
60 days
Amount
Out sourcing of services for operation of lift at W-8 block and S-1 block (Four lifts ie. 8 passengers-02 Nos &13 passengers-02 Nos of Make Omega & Thyssen Krupp respectively) in two shifts, one semi skilled lift operator per shift of 08 Hrs for operation and maintaining lift panel room, lift car and connected machinery of the lifts ,on all seven days of the week complete all as specified and as directed by Engr-in-Charge.
Out sourcing of services for operation of lift at C-10 and MES- Type II blocks (Four lifts ie., 8 passengers- 02 &13 passengers-02 of Make Thyssen krupp) in two shifts, one semi skilled lift operator per shift of 08 Hrs for operation and maintaining lift panel room, lift car and connected machinery of the lifts on all seven days of the week complete all as specified and as directed by Engr-in-Charge.
Out sourcing of services for operation of lift at DSC block & NC-I block (Four lifts ie. 8 passengers-02 &13 passengers-02 of Make Omega) in two shifts, one semi skilled lift operator per shift of 08 Hrs for operation and maintaining lift panel room, lift car and connected machinery of the lifts on all seven days of the week complete all as specified and as directed by Engr-in-Charge.
Out sourcing of services for operation of lift at MES- Type IV blocks (Two lifts ie., 8 passengers- 01 &13 passengers-01 of Make Thyssen krupp) in two shifts, one semi skilled lift operator per shift of 08 Hrs for operation and maintaining lift panel room, lift car and connected machinery of the liftson all seven days of the week complete all as specified and as directed by Engr-in-Charge.
Out sourcing of services for operation of lift at HQ SWAC building (One lift ie. 8 passengers-01 of Make Omega) in one shift, one semi skilled lift operator per shift of 08 Hrs for operation and maintaining lift panel room, lift car and connected machinery of the lifts on all seven days of the week complete all as specified and as directed by Engr-in-Charge.
Notes :- (a) The work shall be carried out in shifts (As mentioned against each item of Sch) contractor shall employ one operator per shift, The manpower detailed in such a way that each Operator get weekly off as per prevailing labour act/ law (b) The entire Lift cabin including machinery, equipments in building premises shall be kept neat and clean and necessary oil, Greasing, Minor Servicing as per manufacturer recommendation (Omega/ Thyssen krupp or as existing) shall be carried out to avoid any mishappning all as directed by EIC. (c) Contractor shall provide the two sets of uniform with MES logo to all industrial persons who are employed. (d) Operators should be provided hand tools, tester, Meggar or test lamp, safety shoes and hand gloves will be provided by the contractor without any extra cost. (e) Rates quoted shall be included for minor repair as per daily weekly or monthly check and provision of the lift maint chart which shows the daily, weekly and monthly for monitoring easily and making payment accordingly (f) Electricity as required will be made available to the contractor free of cost by department. (g) Emergency light shall be provided by the contractor during night hours without any extra cost. (h) All safety precautions as per lift rules should be strictly followed by contracted employees & department shall not be held responsible for any untoward incident.
(j) Attendance Register of Staff Employed will be maintained by JE E/M. If any labour is found absent, necessary penalty/recovery will be made at the rate of double the daily minimum wages fixed by govt. or the rate quoted by the contractor, whichever is high (k) The contractor should always keep in mind that it is only the services of these contract labours is outsourced & not manpower. So providing reliever to lift operator will be sole responsibility of contractor. (m) Contractor has to produce Photo ID of the staff employed with security pass number issued by Main Guard Air force Station. (n) GST / EPF paid certificate, attendance of employee etc. shall be enclosed with RAR. (o) The payment to all staffs employed on work shall be preferably made in the Aadhaar linked bank account through account payee cheque only and details shall be submitted with RAR.
M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (03 Nos) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges at Type II ,Type III, C-3 block for 11 month Note- (i) Six routine maintennace services for oiling & greasing (ii) Three visit by state lift inspection are included in the quoted rates.The following items shall be replaced as & when required under AMC 'A' type contract i.e ("all in all").For OMEGA and AMC Platinum type contract i.e ("all in all") for Thyssen lift as existing at site (iii) Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iv) Rate quoted is including of PRE AMC maint work.
All as per item No 6 above but, for 8 passenger lifts (03 Nos )
Note - for item No 6&7 : (i) Any required electrical/ mechanical parts of above mentioned lifs or any other parts also are to be repair/replaced as & when it became unserviceable as per term & condition of omega/ Thyssen Krupp under the AMC 'A' type contract, any cost of material & labour charge will not be paid extra .(ii) Any other material become un serviceable which is not in the scope of AMC 'A' type contract is also to be repaired/replaced timely to run the lift smoothly without any extra payments . (iii) The terms & conditions of this AMC as applicable as given in Annexure I & II by OMEGA and Thyssen Krupp (iv) The comprehensive maintenance inclusive of inspection/testing/preventive maintenance replacement of unserviceable parts/material including labour, transportation. (v)The complaints shall be attended forthwith as the complaints/failure from the time of receipt of same (vi) Contractor shall rectify the defects within 24 hrs after receipt of complaints , otherwise the complaints will be rectified by the other agency and the expenditure incurred will be recovered at Rs 2000/per day till proper functioning of lift. (vii) The schedule A consists of comprehensive maintenance lifts (viii) The load testing of lifts ie 8 passenger and 13 passenger shall be carried out as per standard norms of OMEGA/Thysen and hand over certificate to the department.
Note For particular specification : (a) The work under authorised dealer comprehensive maintenance of lifts all as specified in Sch A ,Special Condition, Particular Specification, MES SSR, latest relevant IS code and as directed by GE/ Engr-in-charge. (b) The tender shall have to submit the copy of MOU with authorised dealer to carry out the comprehensive maintenance in a separate envelop attached with the envelope containing quoted tender documents and failing which the tender will be treated as non- bonafied and will not be considered for opening of the same. (c) Lift machine shall be well experienced in lift/elevators repairs and maintenance. (d) The contractor shall ensure proper functioning of safety devices. (e) The contractor shall provide lift maintenance Chart for Daily, Weely and Monthly (f) All safety precautiobns shall be dispalyed as per lift rules
S&F Fan blower of lift cabin, with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge
S&F Light of lift cabin, with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge
S&F LED light SMT 0701 or suitable model of lift cabin of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge
S&F UPS 1 KVA of lift with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge
S&F 1.50 KVA 920 Watts smart UPS line interactive with internal batteries of lift with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge
S&F 3 KVA smart UPS line interactive with internal batteries of lift with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge
S&F Batteries of capacity 12 Volt and 7 AH for UPS device of lift with existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge
S&F Batteries of capacity 12 Volt and 18 AH for UPS device of lift with existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge
S&F Display of lift with existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge
S&F MCB SP 'C' type 240 V,50 Hz,10 KA of capacity 6-32 Amp as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F MCB SP 'C' type 240 V,50 Hz,10 KA of capacity 40 Amp as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F MCB DP 'C' type 240 V,50 Hz,10 KA of capacity 40 Amp as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F MCB DP 'C' type 240 V,50 Hz,10 KA of capacity 6- 32 Amp as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F MCB TPN 'C' type 240 V,50 Hz,10 KA of capacity 6- 32 Amp as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F MCB TPN 'C' type 240 V,50 Hz,10 KA of capacity 63 Amp as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F MCB isolator FP 'C' type 240 V,50 Hz,10 KA of capacity 100 Amp as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F RCCB 'A' type DP 240 V,50 Hz,10 KA of capacity 25 Amp and 300mA as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F RCCB 'A' type DP 240 V,50 Hz,10 KA of capacity 40 Amp and 30mA as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F RCCB 'A' type FP 240 V,50 Hz,10 KA of capacity 40 Amp and 30mA as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F RCCB 'A' type FP 240 V,50 Hz,10 KA of capacity 40 Amp and 300mA as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
S&F RCCB 'A' type FP 240 V,50 Hz,10 KA of capacity 25 Amp and 300mA as suitable for existing lift panel complete as in repairs all as specified and as directed by Engr- in- Charge
Dighard Electricals
Shree Krushna Supply Corporation
ALBA AC AND REF SERVICES
divyarsh entrprise
BK CONSTRUCTION
A.G.ENTERPRISES
Shri Sai Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .