Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC HOUSE NO 206 GALI NO 4 GAUPURI OPP GAUSHALA PHATAK GHAZIABAD UP 201009 | GHAZIABAD | UTTAR PRADESH | 201009 | L1 | Accepted-AOC Ok | |
| 2 | L2₹23.7 L+₹3.3 L (16.2%)Rejected-AOC LANE NO 11 HOUSE NO 4 INDRAPRASTHA COLONY UPPER NATHANPUR RING ROAD DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Ok | |
| 3 | L3₹24.1 L+₹3.7 L (18.1%)Rejected-AOC 34 RAJA ROAD DEHRADUN UTTARAKHAND 2480001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC Ok | |
| 4 | L4₹25.4 L+₹5.0 L (24.6%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L4 | Rejected-AOC Ok | |
| 5 | L5₹25.4 L+₹5.0 L (24.7%)Rejected-AOC | L5 | Rejected-AOC Ok |
Tender Value
₹31.0 L
EMD Value
₹62,060
Closing Date
14 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Dehradun
HQ CWE Dehradun
SPL REPAIR TO TOILET IN BLDG NO P-4 (OLD CADET MESS) AT RIMC DEHRADUN UNDER GE DEHRADUN
2025_MES_704539_1
0020/DDN/E8
Open Tender
Civil Works
Works
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE Dehradun
₹62,060
Yes
23 Jun 2025
17 Apr 2025
16 May 2025
17 Apr 2025
14 May 2025
1 May 2025
Amount
Demolition brick or stone masonary built in cement mortar including all quoins arches pillars etc but excluding ashlars facing dressed stone work and precast concrete block, complete all as specified and as directed.
Dismantling asbestos cement (corugated or semicorrugated etc) sheets, in roof covering including ridge complete all as specified and as directed.
Dismantling timber scantling 40 Sqcm and over in section in unframed work in any position complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm each including making good disturbed portion of wall complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size exc 1.5sqm but n.exc 4.0 Sqm each including making good disturbed portion of wall complete all as specified and directed.
Demolition of reinforced cement concrete concrete (reinforcement cut as required to facilitate demolition) in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling of cast iron pipe alongwith fitting and accessories 100mm dia jointed in cement mortar and taking out of wall, floor or trenches complete all as specified and directed.
Dismantling of cast iron pipe alongwith fitting and accessories 75mm dia jointed in cement mortar and taking out of wall, floor or trenches complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
Taking up or down steel tubing and connections including cleaning for refixing or removal from site for 15 mm bore GI tubing complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal from site for 20mm bore GI tubing complete all as specified and directed.
Dismantling of water tanks capacity exc 250 ltr but not exc 500 ltrs complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar complete all as specified and directed.
Taking down cement plaster of any description on brick/stone/concrete wall surfaces of any description including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed.
Dismantling wall and ceiling boards, fibre or pulp, insulation etc. in insulation boards slabs, blankets any thickness incl cover fillets. complete all as specified and directed.
M & L for 595 mm X 595mm false ceiling system , using hot dipped galvanised steel section exposed surface with precoated capping, GI powder coated tee and cross tee of size 24x32mm & 24x27mm having 0.27mm gauge at every 600mm c/c interval and wall angle of size 19x19mm having 0.35mm gauge fixed to the wall. The above grid is to be suspended at every 1200mm c/c in both direction using 2mm thick pre-straightened GI wire laying designer tile ivory painted (high pressure steam cured) of 4 mm thickness (as per IS 14862) of size 595x595 mm and antine of the design (cascadev or electra) , back of the tile duly sanded and finished with a coat of protective paint over the formed grid etc complete all as specified and directed.
S&F mild steel for Joist, channel, angle, or tee sections, MS tubes, flats, square bars etc fixed independently, without connecting plates as in truss any type framing including purlins and rafters etc confirming to FE-410-W (GdeE-250 quality-A) complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls etc fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls etc fixed with self tapping screws complete all as specified and directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre depth for foundation, manhole etc not exc 10 Sqm on plan and not exc 1.5 metre in depth including getting out in soft/loose soil complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 ltrs of emulsion per square meter of surface area complete all as specified and as directed.
M&L for Anti termite treatment treating the backfill in contact with foundation at the rate of 7.5 ltrs of emulsion per square metre of vertical surface (Area of the sub structure in contact with back fill to be measured) complete all as specified and as directed.
M&L for Anti termite treatment treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
M&L for Anti termite treatment treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L for Anti termite treatment Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 CM in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base or leveling course of floor etc complete all as specified and directed.
M & L for RCC M-25 (Design Mix), using 20mm graded stone aggregate as in foundation, footings, foundation beams, plinth beams, bases for columns, etc basement slabs and mass concrete complete all as specified and directed.
M & L for RCC M-25 (Design Mix), using 20mm graded stone aggregate as in as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for RCC M-25 (Design Mix), using 20mm graded stone aggregate as in as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M & L for RCC M-25 (Design Mix), using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, chajja and in shelves and the like complete all as specified and directed.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of form work to sides of pillars, posts, columns fair finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc fair finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for flat fair finished surfaces of concrete (Horizontal or sloping) complete all as specified and directed.
M & L for use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide for flat fair finished surfaces of concrete complete all as specified and directed.
M & L for use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges for fair finished surfaces of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT MS bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L excavated earth for preading and levelling in layers n exc. 25cm thick and well ramming including watering complete all as specified and directed. (Earth obtained from excavation will be used)
M&L for hardcore of broken bricks or boulder gauge exc 63mm but n. exc 100mm, deposited , spread and levelled in layers n.exec 15 cm thick, watered and rammed to a tue surface complete all as specified.
M&L for 75mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L for brick work with old size fly ash brick straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work (Except bricks) straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6complete all as specified and directed. (Old bricks obtained from demolition will be reused)
M&L for half brick work with subclass ‘B’ bricks, straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with and including water proofing compound finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick, area of each tile exc 0.11sqm but not exc 0.18sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces in dado, skirting of size 300mm x 450mm x 7mm thick fixed over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for machine cut kota stone slab flooring 18-20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing laid over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in window or door cill,lintel, benching to drain, holdfast, coping, bed block, posts, boundary pillars, bonders etc. and the like edge slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M & L 18 to 20mm thick granite ( colour as approved by GE) stone slab machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform/dado/skirting /plateform counter top WHB in cluding cutting holes for oval shape /urinal partitions etc. including 15 mm thick cement screed bed 1:6 CM in horizontal or vertical surfaces including grinding the edges half round and polishing complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm width in brick wall complete all as specified & directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing complete all as specified and directed..
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing complete all as specified and directed..
Refixing of 20mm bore old steel tubing and connections in new or old position with all new fittings to floor, wall or ceiling complete all as specified and directed.(Old pipe obtained from taking down will be reused)
S&F factory made single extruded WPC(Wood polymer composite) Solid door frame/ chowkat of size 100X50 comprising of virign PVC polymer of K value 58-60 (suspension grade ) calcium corbonate and natural fibers ( wood powder/rice husk /wheat husk) and non toxic additives (max toxicity index of 12 to 100 gms) fabricated with mitred joints and applying PVC solvent cement and screwed with full body threaded star headed SS screws having min frame density of750Kg/cum screw withdrawal strength of 2200 N (face) & 1100 N edge,minimum compressive strength of 58 N/mm2, moduus of elasticity 900N/mm2 and resistance to spread of flame of class 'A' category with property of being termite / borer proof, water / moisture proof & fire retardant & fixed in postion with SS dash fasterns / hold fast of required dia and length,colour of door frame to match that of shutter all as specified and directed. Make : ECHON/ Kumar Tech/ TVL Engineers Ltd (Floresta)/ Rajshree
S&F factory made single extruded WPC (Wood polymer Composite) Solid moulded Flush Door Shutter of 30 mm size comprising of virgin PVC resin of K value 58-60 (Suspension Grade), Calcium Carbonate and natural Fibers (Wood Powders/ rice husk/ wheat husk) and Non toxic additives (max toxicity index of 12 for 100 gms) having min density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) &900 N (Edge) Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of class A category with property of being Termite/ Borer proof. Water/ Moisture Proof, Fire retardant and fixing with stainless steel but hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer - in- Charge, Materia test certificate and authentication should be compulsory provided by the manufacturing company. Make : ECHON/ Kumar Tech/ TVL Engineers Ltd (Floresta)/ Rajshree .
S&F aluminium anodised tower bolt 200 mm long of extruded section complete all as specified and as directed.
S&F aluminium alloy, anodised, sliding door bolt size 300 mm with hasp, staple (bolt ype) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S&F 150 mm long aluminium handle, cast type, anodised complete all as specified and as directed.
M&L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed.
M&L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and as directed.
S&F aluminium die cast body door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete all as specified and as directed.
S&F mild steel window grills framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding, FE-290 grade E-165 complete all as specfied and directed.
S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2, (using 40mm graded stone aggregate) as in plinth protection and finishing even and smooth without using extra cement incl necessary formwork complete all as specified and directed.
S&F 500 litre rotational moulded tripple layer polyethlene water storage tanks white colour (cylindrical vertical with closed top) and suitable size of MS tasla with locking system hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F as in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20 mm bore complete all as specified and as directed
S&F in repair vitreous china wash down water closet pan (pedestal pattern) rimless wall hung WC with UF soft close slim seat cover, Hinges and acessories etc complete all as specified and directed. Make : Jaquar Cat No CNS-WHT-963UFSM or equivalent in Cera/Hindware/Parryware/Somany
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white with 'P' trap, including connection to drain or out going pipe and flush pipe anti symphonize pipes etc complete all as specified and directed.
S&F single piece slim concealed Cistern with wall mounting frame, installation kit and "s type" drain pipe connection set for wall hung WC (with flush control panel complete all as specified and directed.) Make : Jaquar Cat Pt No : JCS-WHT-2400WS or equivalent in Cera/Hindware/Parryware/Somany
S&F flush control plate for concealed cistern complete all as specified and directed. Make Jaquar Cat Part No:JCP-CHR-852415 or equivalent in Cera/Hindware/Parryware/Somany
S&F vitreous china urinal (back inlet with fixing accessories size 385 x 325 x 635mm complete all as specified and directed. Make: Jaguar Cat Part No: URS-WHT-13253N or equivalent in Cera/Hindware/Parryware/Somany
S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe for squatt pattern complete all as specified and directed.
S&F vitreous chinaware wash hand basin table top of size 575 x 430 x 175 mm complete including waste coupling ,waste pipe including fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed. Make : Jaquar Cat Part No ACS-WHT-87901 or equivalent in Cera/Hindware/Parryware/Somany
S&F in repair vitreous china urinals half stall urinal (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing complete incl making good exisiting surface complete all as specifed and directed.
S&F in repairs vitreous china coloured wash hand basin with pedestal of size 55X40 cm including waste coupling ,waste pipe including fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed.
S&F in repair brass chromium plated bottle traps for wash basins, urinals with inlet and outlet screwed for pipe or connections inclding necessary packing union and cap and fixed complete all as specified and directed.
S&F concealed body for single lever wall mounted basin mixer without exposed parts complete all as specifed and directed Make : Jaquar Cat Part No : ALD 235NSO or equivalent in Cera/Hindware/Parryware/Somany
S&F exposed part kit of single lever basin mixer wall mounted consisting of operating lever, cartridge sleeve, wall flange, nipple & spout compatible with ALD - 233N & 235N complete all as specifed and directed Make : Jaquar. Cat part No ARI-39233NK or equivalent in Cera/Hindware/Parryware/Somany
S&F in repair soap dispenser with glass bottle in toilet block each one complete all as specified and directed. Make Jaquar Cat Part No: AKP -35735P or equivalent in Cera/Hindware/Parryware/Somany
S&F in repair toilet roll Holder complete all as specified and as directed Make : Jaquar Cat Part No : 35751P or equivalent in Cera/Hindware/Parryware/ Somany
S&F in repair bib tap long body fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia bore pipe complete all as specified and as directed. Make Jaquar Cat Pt No: VGP-81037 or equivalent in Cera/Hindware/ Parryware/ Somany
S&F in repair bib tap long body fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia bore pipe complete all as specified and as directed
S&F in repair stop valves/angle valves fancy type chromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions fixed for 15 mm dia bore pipe complete all as specified and as directed
S&F in repair tubular towel rail 20mm dia type brass chrormium plated 600mm long stainless steel between flanges complete all as specified and as directed Make : Jaquar Cat Pt No: ACN-1111SM or equivalent in Cera/Hindware/Parryware/ Somany
S&F in repair PVC connection of 45 cm length including brass nuts complete all as specified and as directed.
S&F in repair fancy type glass corner 300mm radius of 10mm thick toughned glass with CP railing fixed with fancy type screws complete all as specified and directed.
S&F in repair pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, fancy type screwed for iron of 15mm bore of pipe complete all as specified and directed.
S&F in repair health faucet mild steel chromium plated suitable for 15mm dia pipe with 1 or 1.25mtrmetre long flexible tube and ABS wall hook fixed to wall all as specified and directed. Make Jaquar Cat Pt No :- ALD 573 or equivalent in Cera/Hindware/Parryware/ Somany
S&F urinal spreader of PTMT/ABS body of any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
S&F in repair for 75 mm bore out let cast floor trap spun pipe (conforming to IS 3989) incl cockroach trap with gratings including jointing to waste pipe fixed in cement concrete tpe B-1 (1:2:4) etc complete all as specified and as directed.
S&F for 75 mm bore Cast iron spun pipe (conforming to IS 3989) soil, waste and vent pipes, in any length with or without ears with lead joints, laid in trenches or in floors complete all as specified and as directed.
S&F for 75 mm bore Cast iron spun pipe (conforming to IS 3989) soil, waste and vent pipes, in any length with or without ears with lead joints, fixed to wall vertically complete all as specified and as directed.
S&F 100 mm bore Cast iron spun pipe (conforming to IS 3989) soil, waste and vent pipes, in any length with or without ears with lead joints, laid in trenches or in floors or vertically cast, complete all as specified and as directed.
S&F in repair 100 mm bore cast iron Bends of (any radius), spun pipe (conforming to IS 3989) diminishing piecs or tapers (larger bore measured) complete all as specified and as directed.
S&F in repair 75 mm bore cast iron Bends of (any radius), spun pipe (conforming to IS 3989) diminishing piecs or tapers (larger bore measured) complete all as specified and as directed.
S&F 50 mm bore cast iron cowls spun pipe (conforming to IS 3989) complete all as specified and as directed
M&L for applying two coats of acrylic distemper over a coat of primer, white or tinted over 1 mm thick wall care putty in two coats complete all as specified & directed.
M&L for applying three coats of white wash on ceiling on new/old plastered surfaces including preparation of surfaces complete all as specified and as directed
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed.
M&L for providing precast cement concrete type B-0, 1:2:4 using 12.5mm graded stone aggregate in coping with plain fair faces incl chamferes, weathering, throating etc and set in CM 1:4 complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in concrete bed to drain pipes of 150 mm dia including packing under and haunching against the sides of pipes after they are laid and tested including dismantling complete all as specified and directed.
S&F reinforced concrete pipes,150mm dia class NP-2 laid and jointed complete with collars including dismantling complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specified and directed.
M&L for providing pre cast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cover slab and man hole covers etc complete all as specified and directed.
M&L for PCC 1:3:6 type C-0 ( using 12.5 mm thick graded stone aggragate) as in surface channel and drains including necessary form work complete all as specified and directed
S&F 25mm thick precast cement concrete louvres and jallies, in PCC 1:3:6 type C-0 (using 12.5 mm graded stone aggragate) fixed in CM 1:6 (measured solid) including all mouldings but excluding frame complete all as specified and directed.
S&F frosted toughen glass 10mm thick fixed to wall complete all as specified and directed by Engr-in-Charge
S&F frosted toughen glass 8mm thick fixed to wall complete all as specified and directed by Engr-in-Charge
S&F aluminium composite panel 6 to 8mm thick with stainless steel 304 grade as in framing and necessary bracket incl door as In water closet area complete all as specified and as directed.
M&L for 3 mm thick APP modified prefabricated in five layers & weight not less than 3.6 Kg/Sqm water proof membrane reinforced with non-wooven polyster with two coats of water proofing aluminium paint over top surface of water proofing membrane with 15cm longitudinal & horizontal over lapping and joints finally pasted with thermo- fused with LPG flames laid over a coat bitumen @ 1.20 Kg /Sqm over a coat bituminous of primer 0.40 ltr per sqm over after cleaning existing plastered surfaces as per manufacturer instruction of APP modified membrane etc. APP modified membrane shall be laid on primed surface by torch application method after allowing 24 hours for primer to dry complete all as specified and as directed. Notes :- Rates includes to carried out the work on roof slab up to 3rd stories building nothing extra shall be admissible on this account.
M&L for writing letter or figures (Block, Roman, Italic or Indian) n.exc 30cm complete all as specified and as directed.
M&L for writing stop commas, short lines, dashes, hyphens, brackets etc complete all as specif eid and directed.
M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour (Red & Yellow), design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.all as per specified and directed.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
One light point controlled by one-one way switch.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
All as per item No 124 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm complete all as specified and directed.
S&F ceiling rose, surface bakelite 3 terminal of size 65x25mm complete all as specified and directed.
S&F modular switch 1 way 6A, one way, 230 volts all as specified and directed.
S&F modular socket 6A-2/3 pin, 2 module, 230 volts all as specified and directed.
S&F modular socket combination 6/16 A, 2/3 pin, 230 volts all as specified and directed.
S&F modular switch 1 way 16A, one way, 230 volts all as specified and directed.
S&F energy efficient LED mirror light fittings 10 Watts, 230 volts with efficiency of not less than 110 per watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F round/square shape 16 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with 3 core flexible copper conductor cable, complete all as specified and directed.
S&F energy efficient LED tube light fittings 20 Watts, 230 volts with efficiency of not less than 110 per watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp, fixed on pole duly fixed on angle iron bracket complete all as specified and directed.
S&F Exhaust fans metallic body,single phase 230/ 240 V AC, 300mm sweep, 50 Hz with louvers & shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts in and including PCC block (1:2:4) B-1 complete all as specified and directed.
S & F Geyser 3 level safety, capillary thermostate, adjustable, automatic thermal cutout and multifunctional wall to provide higher safety, ISI marked nickle coated heating element of recommended capacity not less than 2KW to provide resistance against scale formation and EPAC coated inner tank having minimum 8 Kg/cm2 pressure bearing capacity , vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof ABS body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall including 15mm bore NRV on GI pipe connetion complete all as specified & directed.
S&F sheet metal enclosures 240 volts SPN 8 way with suitable rated bus bar for double door IP-43 DB's complete all as specified and directed .
S&F MCB SP 240 volt 10 KA, 5 to 40 Amp, 'C' curve complete all as specified & directed.
S&F MCB SPN 240 Volt 10 KA, 40 Amp, 'C' curve complete all as specified and directed.
S&F metal clad single pole and neutral enclosure with 2 pin and earth plug and socket complete with and including one single pole MCB 20 Amp 240 Volt complete all as specified and directed.
M&L for submain wiring with 3 runs (N+P+E) of 1.5 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed/surface PVC conduit pipe of medium duty not less than 15mm dia including necessary PVC conduit specials and connecting with suitable size thimble, including taking old wiring complete all as specified and directed. Note:-3 runs of 1.5 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
All as per item No.141 above but with 3 runs (N+P+E) of 2.5 Sqmm single core copper FRLS conductor. Note:-3 runs of 2.5 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
All as per item No 141 above but with 3 runs (N+P+E) of 4 Sqmm single core copper FRLS conductor. Note:-3 runs of 4 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
All as per item No.141 above but with 6 runs (3 runs P+N+ 2 run Earth) of 6 Sqmm single core copper FRLS conductor and PVC conduit not less than 24 mm dia. Note:-6 runs of 6 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) complete all as specified and directed.
Supply, laying and testing XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 10 sq mm 4 core after cutting to required length with necessary glands, nuts, bolts, and lugs laid in trenches/fixed to wall etc complete all as specified and directed
M&L for sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection all as specified and directed.
M&L for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches complete all as specified and directed
M/s Teg Singh Negi (BID ID -3295091)
Shree Durgai Construction Co. (BID ID -3291835)
M/S S P BUILDERS (BID ID -3296935)
M/S C S AITHANI (BID ID -3296555)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .