Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹13.4 L+₹24,450 (1.86%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹13.5 L+₹38,933 (2.96%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹14.6 L+₹1.5 L (11.2%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹17.4 L+₹4.2 L (32.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | R N Enterprises L1 | Raman Electric Trading Co L4 | kapil enterprises L5 | The Rahul Vig L2 | Saurav Enterprises L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Rectification of complaints at Haig Line Power House of HT UG/OH electric distribution network by attendng daily complaints including Sunday and other holidays for round the clock and making the same serviceable in all respects alongwith replacement of any major part including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include visual inspection of OH lines, Earth Resistance of transformer, switch gear, GOD switch etc. Quoted rate also include excavation of faulty cable and making seviceable with accessories like joints, Fuse wire for GOD switch complete all as specified and directed. | 3,120 | Each Complaint | 65 ₹2,02,800 Lowest | 80 ₹2,49,600 | 100 ₹3,12,000 | 94 ₹2,93,280 | 70 ₹2,18,400 |
| 2.00 | Rectification of complaints at Haig line Power House of LT UG /OH electric distribution network, Security and street lights by attendng daily complaints including Sunday and other holidays for round the clock and making the same serviceable in all respects alongwith replacement of any major part including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include visual inspection of OH lines, Earth Resistance of transformer, switch gear, GOD switch etc. Quoted rate also include excavation of faulty cable and making seviceable with accessories of all nature like No light, faulty insulator, broken conductor & cable fault , burnt out MCCB`s, MCBs, isolators, switch fuses, service cables etc upto DB in buildings/OTM complete all as specified and directed. | 3,600 | Each Complaint | 65 ₹2,34,000 Lowest | 84 ₹3,02,400 | 100 ₹3,60,000 | 90 ₹3,24,000 | 70 ₹2,52,000 |
| 2.01Note for Ser Item No 1.00 & 2.00:- (i) Any complaint left unattended will be communicated to the JE in-charge /AGE E/M with reason. Penalty of Rs. 200/- per day will be levied from the contractor if the complaint is not attended and completed within 24 hours. (ii) Material required for completing the job shall be measured and paid for separately under relevant items of BOQ. (iii) Contractor shall provide all type of T&P of LT street lights network, bamboo ladder with safety gloves for attending the external electric complaints. (iv) Contractor shall provide the complaint register 200 pages – 3 No, complaint book with 100 slips- 5 No. Booklets serially numbered in triplicate. (v) Contractor will provide adequate/ sufficient No of manpower round the clock including Sunday & holidays to receive and attend Complaints. (vi) Cost of materials for laying of cables, stretching of OH conductor, burnt out joints, fuse wires, insulator and jumper will be measured and paid separately under relevant items as Material & Labour. (vii) The scope of work cover all complaints received from above concern power houses will be lodged/ docketed/ attended/ completed. The completion will be rendered on complaint register as well as on docket. Nature of fault may occurs given below :- (a) Blown out fuses (b) Faulty Insulator (c) Loose GOD male & female contact (d) Faulty cable joint (e) O/H conductor broken | ||||||||
| 2.02(f) Broken jumpers (g) Tightening of stay (h) Stretching of broken loose fault conductor and binding on insulators up to 3 span (j) Contractor will provide all the tools such as HT/LT meggar, Insulation Tester, Wrench, Rope, Bamboo ladder, search light and other tools and will maintain them in working condition all the time. (k) Tightening of service connection as preventive maintenance. (l) Proper Uniform shall be provided by the contractor for persons employed on duty as directed by Engr-in-Charge. (m) Tracing fault manually in LT/HT electric lines and underground cable network. (n) AC Complaints like connection / disconnection (o) Fault HT/LT switchgears (p) Switching ON/OFF street lights at appropriate time as directed by JE/Engr-in-Charge. Penal recovery for Rs 100/- per day will be recovered if street light are not put ON/OFF at appropriate time. (q) The area covered under the above power house consists of HT/LT overhead lines. HT/LT underground cables, distribution transformers, HT/LT switch gears, streer lights etc, including HT 11 KV incoming and numbers of outgoing HT feeders for the complete area. | ||||||||
| 2.03(r) Any other electric complaint which is considered essential by the department. (s) Confirmation on completion of any nature of major complaints will be intimated to JE EM or Engr-in-Charge immediately. (t) The contractor will observe all labour laws as prevalent during the currency of work enacted by Central/State Deptt as well as Labour Commissioner Act. He shall also ensure, payment of minimum wages to the persons employed as per labour laws in vogue. (u) The contractor will provide the rain coats, gum boot and hand gloves in winter and summer season. (v) Contractor will have no rights to object the work carrying out by other contractor at substation or HT/LT distribution system of the power house area under comprehensive maintenance. However necessary handing taking over the assets will be carried out between the agencies. (w) Contractor will provide necessary vehicle for attending the complaint under above power house area. | ||||||||
| 3.00 | Labour only for carry out visual inspection of transformer once in month including minor maintenance like dusting ,tightening of loose connection HT/LV Side and replacement of aluminium terminal and checking of transformer oil level ,top up if required ,checking of silca gel ,heating/replacement of silca gel all as specified and as directed.T&P required for the job is deemed to be included in contract. The record of the same will be submitted in the performa as directed. | 250 | Each Job | 100 ₹25,000 | 50 ₹12,500 | 90 ₹22,500 | 25 ₹6,250 Lowest | 70 ₹17,500 |
| 4.00 | Trimming of Tree branches falls into OH lines of HT/LT & minimum clearance of 3 Mtr from branches ,proper shut down will be taken and maintained in the register complete all as specified and directed. | 150 | Each Span | 25 ₹3,750 Lowest | 50 ₹7,500 | 60 ₹9,000 | 25 ₹3,750 Lowest | 70 ₹10,500 |
| 5.00 | Maintenance of sub Station including cleaning in /out of surroundings areas, zeroing of grass in two pole & four pole str ,loose filling of sand/pebbles as required,operations of GODs ,Measuring of earth resistance of transformer,GODs ,LA & Switchgears ,Records of Earth resistance will be maintained complete all as specified and directed. | 150 | Each Job | 50 ₹7,500 | 30 ₹4,500 Lowest | 30 ₹4,500 Lowest | 30 ₹4,500 Lowest | 100 ₹15,000 |
| 6.00 | Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) make the cable serviceable with Straight through joint of size 95-400 Sqmm complete all as specified and directed.
Notes:- (a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges deemed to be included in the quoted rate.
(b) Charge of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate.
(c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will levid Rs 500/ per hour.
(d) Straight through joint , 95 to 400, sqm, Labour charges, excavation and making joint deemed to be including in quoted rate. | 5 | Each Job | 7,315.4 ₹36,577 | 3,000 ₹15,000 Lowest | 9,500 ₹47,500 | 7,008 ₹35,040 | 9,000 ₹45,000 |
| 7.00 | Material & Labour in replacement of aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm complete all as specified and directed. | 100 | Each | 45 ₹4,500 | 12 ₹1,200 | 16 ₹1,600 | 18 ₹1,800 | 10 ₹1,000 Lowest |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
21 Aug 2025, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
COMPREHENSIVE MAINT OF LT PANELS INCL SWITCHGEARS LT UG CABLE NETWORK AND STREET LIGHTS INCLUDING ALLIED WORK AT SECTOR A UNDER GE UTILITY AMBALA
2025_MES_722149_1
CA NO GE U AMB 55 OF 2025-26
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹44,000
12 Sept 2025
23 Jul 2025
23 Aug 2025
23 Jul 2025
21 Aug 2025
7 Aug 2025
23 Jul 2025 - 30 Jul 2025
Amount
Rectification of complaints at Haig Line Power House of HT UG/OH electric distribution network by attendng daily complaints including Sunday and other holidays for round the clock and making the same serviceable in all respects alongwith replacement of any major part including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include visual inspection of OH lines, Earth Resistance of transformer, switch gear, GOD switch etc. Quoted rate also include excavation of faulty cable and making seviceable with accessories like joints, Fuse wire for GOD switch complete all as specified and directed.
Rectification of complaints at Haig line Power House of LT UG /OH electric distribution network, Security and street lights by attendng daily complaints including Sunday and other holidays for round the clock and making the same serviceable in all respects alongwith replacement of any major part including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include visual inspection of OH lines, Earth Resistance of transformer, switch gear, GOD switch etc. Quoted rate also include excavation of faulty cable and making seviceable with accessories of all nature like No light, faulty insulator, broken conductor & cable fault , burnt out MCCB`s, MCBs, isolators, switch fuses, service cables etc upto DB in buildings/OTM complete all as specified and directed.
Note for Ser Item No 1.00 & 2.00:- (i) Any complaint left unattended will be communicated to the JE in-charge /AGE E/M with reason. Penalty of Rs. 200/- per day will be levied from the contractor if the complaint is not attended and completed within 24 hours. (ii) Material required for completing the job shall be measured and paid for separately under relevant items of BOQ. (iii) Contractor shall provide all type of T&P of LT street lights network, bamboo ladder with safety gloves for attending the external electric complaints. (iv) Contractor shall provide the complaint register 200 pages – 3 No, complaint book with 100 slips- 5 No. Booklets serially numbered in triplicate. (v) Contractor will provide adequate/ sufficient No of manpower round the clock including Sunday & holidays to receive and attend Complaints. (vi) Cost of materials for laying of cables, stretching of OH conductor, burnt out joints, fuse wires, insulator and jumper will be measured and paid separately under relevant items as Material & Labour. (vii) The scope of work cover all complaints received from above concern power houses will be lodged/ docketed/ attended/ completed. The completion will be rendered on complaint register as well as on docket. Nature of fault may occurs given below :- (a) Blown out fuses (b) Faulty Insulator (c) Loose GOD male & female contact (d) Faulty cable joint (e) O/H conductor broken
(f) Broken jumpers (g) Tightening of stay (h) Stretching of broken loose fault conductor and binding on insulators up to 3 span (j) Contractor will provide all the tools such as HT/LT meggar, Insulation Tester, Wrench, Rope, Bamboo ladder, search light and other tools and will maintain them in working condition all the time. (k) Tightening of service connection as preventive maintenance. (l) Proper Uniform shall be provided by the contractor for persons employed on duty as directed by Engr-in-Charge. (m) Tracing fault manually in LT/HT electric lines and underground cable network. (n) AC Complaints like connection / disconnection (o) Fault HT/LT switchgears (p) Switching ON/OFF street lights at appropriate time as directed by JE/Engr-in-Charge. Penal recovery for Rs 100/- per day will be recovered if street light are not put ON/OFF at appropriate time. (q) The area covered under the above power house consists of HT/LT overhead lines. HT/LT underground cables, distribution transformers, HT/LT switch gears, streer lights etc, including HT 11 KV incoming and numbers of outgoing HT feeders for the complete area.
(r) Any other electric complaint which is considered essential by the department. (s) Confirmation on completion of any nature of major complaints will be intimated to JE EM or Engr-in-Charge immediately. (t) The contractor will observe all labour laws as prevalent during the currency of work enacted by Central/State Deptt as well as Labour Commissioner Act. He shall also ensure, payment of minimum wages to the persons employed as per labour laws in vogue. (u) The contractor will provide the rain coats, gum boot and hand gloves in winter and summer season. (v) Contractor will have no rights to object the work carrying out by other contractor at substation or HT/LT distribution system of the power house area under comprehensive maintenance. However necessary handing taking over the assets will be carried out between the agencies. (w) Contractor will provide necessary vehicle for attending the complaint under above power house area.
Labour only for carry out visual inspection of transformer once in month including minor maintenance like dusting ,tightening of loose connection HT/LV Side and replacement of aluminium terminal and checking of transformer oil level ,top up if required ,checking of silca gel ,heating/replacement of silca gel all as specified and as directed.T&P required for the job is deemed to be included in contract. The record of the same will be submitted in the performa as directed.
Trimming of Tree branches falls into OH lines of HT/LT & minimum clearance of 3 Mtr from branches ,proper shut down will be taken and maintained in the register complete all as specified and directed.
Maintenance of sub Station including cleaning in /out of surroundings areas, zeroing of grass in two pole & four pole str ,loose filling of sand/pebbles as required,operations of GODs ,Measuring of earth resistance of transformer,GODs ,LA & Switchgears ,Records of Earth resistance will be maintained complete all as specified and directed.
Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) make the cable serviceable with Straight through joint of size 95-400 Sqmm complete all as specified and directed. Notes:- (a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges deemed to be included in the quoted rate. (b) Charge of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will levid Rs 500/ per hour. (d) Straight through joint , 95 to 400, sqm, Labour charges, excavation and making joint deemed to be including in quoted rate.
Material & Labour in replacement of aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm complete all as specified and directed.
Material & Labour in replacement of aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm complete all as specified and directed.
Material & Labour in replacement of aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm complete all as specified and directed.
Material & Labour in replacement of aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 630 sqmm complete all as specified and directed.
Supply only chemical (Round up) to remove unwanted vegitation/grass at various locations complete all as specified and directed.
Material & Labour in replacement of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 25-50 Sqmm complete all as specified and directed.
Material & Labour in replacement of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm complete all as specified and directed.
Material & Labour in replacement of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-185 Sqmm complete all as specified and directed.
Material & Labour in replacement of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.50 x 240-400 Sqmm complete all as specified and directed.
Material & Labour in replacement of straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4 x 25-50 Sqmm complete all as specified and directed.
Material & Labour in replacement of straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm complete all as specified and directed.
Material & Labour in replacement of straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-400 Sqmm complete all as specified and directed.
Material & Labour in replacement of old UNSV shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and directed.
Material and labour in replacement of aluminium conductor steel reinforced (ACSR) of size 6/1 x 2.59 (Weasel) and 6/1 x 2.11 (Squirrel) or other existing type conductor ISI marked for LT over head lines on poles including stretching, tightening of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor complete all as specified and directed.
Material & Labour in replacement of 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 Metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed.
All as per item ser No 21.00 here in before but for 6 sqmm 2 core complete all as specified and directed.
All as per item ser No 21.00 here in before but for 4 sqmm 2 core complete all as specified and directed.
Material & Labour for in replacement of MCCB TPN 400 Amps, 415 Volts, 36 KA,4 pole , complete all as specified and directed.
Material & Labour for in replacement MCCB TPN 250 Amps, 415 Volts, 25 KA, 4 pole , complete all as specified and directed.
Material & Labour for in replacement of MCCB TPN 200 Amps, 415 Volts, 25 KA,4 pole , complete all as specified and directed.
Supply only in replacement MCCB TPN 100/125 Amps, 415 Volts, 16/18 KA,4 pole complete all as specified and directed.
Material and Labour in replacement of danger notice board/plate of 1.6mm thick mild steel sheet , vitreous enameled red colour with letters, figures , and conventional skull and bone in signal white colour and fixed with MS clamps bolts approved size ofr HT 25cmx20 cm complete all as specified and directed.
Supply and replace fuse wire of size 12 SWG (0.104 inch diameter) tinned copper fuse wire typically has a current rating of 30-100 amps, for GOD ISI marked complete all as specified and directed.
All as per item ser No 29.00 here in before but for 14/18 S.W.G complete all as specified and directed.
Supply only PVC self adhesive insulation tape of Size .125mm x 25mm x 25 mtr long ISI marked complete all as specified and directed.
Material & Labour for straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 70-120 Sqmm incl taking down old unsv HT joint complete all as specified and directed.
All as per item ser No 32.00 here in before but for cable 150-240 sqmm 3 core complete all as specified and directed.
Material & Labour in replacement for cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 70-120 sqmm 3 core 11 KV grade earthed system complete all as specified and directed.
All as per item ser No 34.00 here in before but for cable 150-240 sqmm 3 core complete all as specified and directed.
Supply and fix in replacement of LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete all as specified and directed.
All as per item ser No 36.00 here in before but for 5 line complete all as specified and directed.
Re-stretching existing/retrieved ACSR conductor on LT /HTpole and binding conductor on insulator properly using new binding wire/jumper wire complete all as specified and directed. Note : (i) Each Run of line conductor shall be measured in Running Metre from pole to pole.
Material & Labour in replacement of steel nuts, bolts, washers of any size required at site complete all as specified and directed.
Material & Labour for preperation of old decorated surfaces of walls chajjas balcony facia etc and applying two coat of exterior emulsion paint complete all as specified and directed.
Material & Labour for prepering old painted steel suraces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as speciied and directed.
Material and labour of Bamboo ladder 24' height (24 steps ) for LT line and 27 ' height (27 steps ) for HT line complete all as specified and directed.
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 200 KVA complete all as specified and directed.
Supply only loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders incl leveling and spreading lime stone powder under stones complete all as specified and directed.
Material & Labour for providing plain cement concrete 1:3:6 (using 20 mm grade stone aggregate) as in coping, finished even and fair, including necessary form work complete all as specified and directed.
Material & Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint all as specified including taking down the old unsv cross arms and misc accessories complete all as specified and directed.
Supply only pouring new transformer oil as per IS : 335 (1993) for transformers installed at various site for topping up to achieve the di electric strength 60 KV at 4 mm gap, complete all as specified and directed. Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of contract.
Labour only in replacement of silica gel 4-6 mesh suitable for transformers breather and protect VCBs, RMUs from moisture at 11 KV Sub Stations complete all as specified and directed.
Taking down old unsv GOD and Supply, installing, testing and commissioning of air break gang operated triple switch( GOD) outdoor type , vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element having upto 200 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection complete all as specified and directed.
Supply, install, testing and commissioning of lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating including taking down existing complete all as specified and directed.
Material & Labour for surface cleaning of LT steel tubular poles 9 metre long including removing rusted particles painting with two coats of synthetic enamel aluminium paint over a coat of red oxide primer including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as specified and directed. Note : (i) The quoted rate shall includes making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge.
Material & Labour for cement base paint for PCC pole 9 mtr including black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms bracing supports, clamps, eye hooks, security light bracket, clamp etc incl repairing and painting on coping with cement base white paint complete all as specified and directed. Note : (i) The quoted rate shall includes making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge.
Material and labour in replacement of broken earth pit of size 300x300x300 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result complete all as specified and directed.
Material and labour for tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
Material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash including demolition of existing complete all as specified and directed.
Supply and fixing in replacement of off load change over switch with sheet steel Enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed.
All as per item ser No 56.00 here in before but for 200 Amps capacity complete all as specified and directed.
Material and labour for shifting of heavy items upp to 5 Ton excavation / cleaning areas / cleaning site by providing crane/ hydra/ excavators/ tractors with trolley etc as required at site complete all as specified and directed.
Supply & Fixing in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket with clamp from juction box to connecter of street light fitting complete all as specified and directed.
Supply & Fixing in replacement of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps complete all as specified and directed.
Supply & Fixing in replacement of extended spreaders link should be installed both side with exisitng/new MCCBs 4P/3P of any capacity with existing LT panels complete all as specified and directed.
Material & Labour for Chemical spray (DC 2.26 contact cleaner) in container of 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanisum cleanese etc complete all as specified and directed.
Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium busbar and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and directed. Make: Havells/Sintex or equivalent as approved by GE.
Supply and fix in replacement of MCB SP 6-32 Amps, 240 volt,10 KA 'B' curve including all accessories complete all as specified and directed.
Supply and fix in replacement of MCB DP 16-40 Amps, 240 volt,10 KA 'B' curve including all accessories complete all as specified and directed.
Supply and fixing in replacement of single core PVC unsheathed multi stranded copper cable (FRLS) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs, nuts and bolts complete all as specified and directed.
All as per item ser No 66.00 here in before but for 2.5 sqmm complete all as specified and directed.
Supply and fixing in replacement of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. Note: PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in above quoted rates.
Taking down old unserviciable board and supply and fixing of Retro reflective sign board of size 600 x 750 sqmm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 35mm X 35mm X 4mm grouted in PCC 1:3:6 type C-1, 750mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed. Note:- (i) Excavation, earth work, PCC, nuts, bolts, fastners, paint on MS frame and legs shall be included in quoted rates by contractor. (ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge.
Material & Labour for XLPE cable insulated screened, PVC bedded galvanized steel strip of wire armoured , electric power cable (Heavy duty ) with aluminum conductor 11000 volts grade cross sectional area 95 sqmm 3 core suitable for 11 KV earthed system incl taking down old unsv HT cable complete all as specified and directed.
All as per item ser No 70.00 here in before but for 120 sqmm 3core complete all as specified and directed.
All as per item ser No 70.00 here in before but for 185 sqmm 3core complete all as specified and directed.
Supply and fixing in replacement of light grade galvanised mild steel pipe 80mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers complete all as specified and directed. Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule.
Taking down security light, street light, hanger light, flood light and high mast lights of any type at any height fittings such as HPSV/HPMV/MH/LED light of 48 Watt/ 60 watt / 70/72 watt/ 90 watt/ 120 watt/ 150 watt/ 200 watt and 300 watt of any make etc. AC 230 volts any wattage from pole/wall roof top/hanger roof including washing/cleaning of perplex cover inspection for location of fault and replacing of defective spare/parts required for smooth functioning, tighting of electric connection complete and assembling and reconnecting all as per site requirment complete all as specified and directed. Note: Defective spare/ part of relevant light fitting shall be measured and paid separately under relevant item as supply only.
Supply only LED electronic driver/adaptor/SPD for 40-60 watt LED security light fitting as per existing make complete all as specified and directed.
Supply only LED electronic driver/adaptor/SPD for 70/72 watt LED security light fitting as per existing make complete all as specified and directed.
Supply only LED electronic driver/adaptor/SPD for 90 watt LED security light fitting as per existing make complete all as specified and directed.
Supply only LED electronic driver/adaptor/SPD for 60-150 watt LED flood light fitting as per existing make complete all as specified and directed.
Supply only LED electronic driver/adaptor/SPD for 200-300 watt LED flood light fitting as per existing make complete all as specified and directed.
Supply & fixing in replacement of Integral LED Flood light Luminaries 150 Watts consisting of suitable number of LEDs and mounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens, IP 66 protection suitable for mast light mounting, 5700K, LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV , Confirm the tests from auth labs : LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to flood light shall be measured and paid for separately.
Supply & fixing in replacement of LED street light fitting 90 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K, LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs : LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street light shall be measured and paid for separately.
Material & Labour for repairing the GOD mechanism pipe and handle lever, etc. by way of welding, greasing including supply and fixing of new male and female contact complete all as specified and directed.
Supply and topping up of Acid Mixture suitable for Lead Acid batteries of capacity 12V / 24V complete all as specified and directed.
Supply & Fixing in replacement of heavy duty battery cable lead of copper conductor with copper lugs terminal for the 12V 180 AH maintenance free battery suitable for DG set complete all as specified and directed.
Supply and Fixing self-fusing Ethylene Propylene Rubber(EPR) based high-insulating voltage tape of width not less than 19 mm and thickness not less than 0.75 mm of any length to protect HT/LT XLPE cable from moisture and current leakage complete all as specified and directed .
Supply and Fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity from 200 KVA to 1000 KVA complete all as specified and directed.
Supply & Fixing in replacement of HT discharge rod 11-33 KV FRP type with all accessories complete all as specified and directed .
Supply only HT rubber hand gloves 11 KV with electrical insulated latex seamless complete all as specified and directed .
Supply and fix in replacement of unsv 11 KV Digital megger (insulation resistance tester) should have specifications including a test voltage range of 11kV (11,000V) DC, a measurement range for insulation resistance up to at least 100 GΩ, and the ability to perform tests for Polarization Index (PI) and Dielectric Absorption Ratio (DAR). Accuracy +- 5%, safety features, and display capabilities complete all as specified and directed. Make-Metravi, Motwane, and Kusam-Meco
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the LT XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete all as specified and directed. (Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately).
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete all as specified and directed.
Material & Labour for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR part I complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV,Type 1 with peak, size 300mm x 180 mm x 40 mm complete all as specified and directed.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and directed .
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and directed.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and directed.
Material and labour in replacement of unsv PCB for the street/flood light of any type and capacity complete all as specified and directed.
Note:- Amount of credit of Rs. 39557.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
The Rahul Vig (BID ID -3401206)
Saurav Enterprises (BID ID -3393060)
Raman Electric Trading Co (BID ID -3390320)
kapil enterprises (BID ID -3393450)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .