Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | ₹4.9 L | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | Sajju T L1 |
|---|---|---|---|---|
| 1.00UPS Installation | ||||
| 1.00 | OD134751/2025-2026:Supply Installation and testing and commissioning of 10 kVA online UPS pure sinewave with 120 min backup with tubular C10 battery with minimum VAH of 24000. a) 3 ph to 3 ph with bypass arrangement b) Input pf > 0.95 @ full load, c) Output pf : >.95 d) Input voltage range : 320V -460V with cut off e) THD < 10% f) Overall Efficiency >.9 % g) Ambient Temperature : 0-40°C h) Generator Compatibility available. i) Pure sine wave. j) Battery over charge & under charge cut off. k) Bypass arrangement. i) EN/IEC620401 for General Safety compatibility j) LED/LCD Display with digital indications of Input V & A, output V & A, Battery charge, Temperature, frequency q) Approved UPS make : APC/Delta/Numeric) Approved C10 rated tubular battery make:-Exide/Quanta/Amaron, s) Architecture Tower type only (rack mountable not acceptable. t)Marking CE, BIS, ROHS u) All certificates copy to be submitted. v)Three year warranty. Battery rack : Painted MS angle iron rack Suitable for the battery supplied. | 1 | each | 4,29,914.05 ₹4.3 L |
| 1.00 | 90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | 1 | each | 7,274.44 ₹7,274.44 |
| 1.00 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 4 | each | 275 ₹1,100 |
| 1.00 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole | 2 | each | 1,082.14 ₹2,164.28 |
| 1.00 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415
volts, residual current circuit breaker (RCCB), having a sensitivity current 30
milli Amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
63 amps | 1 | each | 3,086.73 ₹3,086.73 |
| 1.01 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | 1 | each | 1,110.86 ₹1,110.86 |
| 1.01 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | 12 | each | 13.46 ₹161.52 |
| 1.01 | OD134759/2025-2026:Supplying and fixing 4 pole Sheet steel enclosure on surface/racess along with 63A,4pole isolator complete with connections testing and commissioning etc.as required. | 1 | each | 1,312.56 ₹1,312.56 |
| 1.01 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp | 50 | metre | 256.76 ₹12,838 |
Tender Value
₹4.9 L
EMD Value
₹12,353
Closing Date
25 Oct 2025, 6:00 pmClosed
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
DEPOSIT-SITC of UPS at various Revenue Offices-SITC of UPS and allied Electrical works at Thalassery Thaluk office-General Electrical Work
2025_PWD_789031_2
PWD/BLDG/TR/16177/2025_6_13_12
Open Tender
Electrical Works
90 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,090
₹12,353
28 Apr 2026
18 Oct 2025
28 Oct 2025
18 Oct 2025
25 Oct 2025
18 Oct 2025
Amount
UPS Installation
OD134751/2025-2026:Supply Installation and testing and commissioning of 10 kVA online UPS pure sinewave with 120 min backup with tubular C10 battery with minimum VAH of 24000. a) 3 ph to 3 ph with bypass arrangement b) Input pf > 0.95 @ full load, c) Output pf : >.95 d) Input voltage range : 320V -460V with cut off e) THD < 10% f) Overall Efficiency >.9 % g) Ambient Temperature : 0-40°C h) Generator Compatibility available. i) Pure sine wave. j) Battery over charge & under charge cut off. k) Bypass arrangement. i) EN/IEC620401 for General Safety compatibility j) LED/LCD Display with digital indications of Input V & A, output V & A, Battery charge, Temperature, frequency q) Approved UPS make : APC/Delta/Numeric) Approved C10 rated tubular battery make:-Exide/Quanta/Amaron, s) Architecture Tower type only (rack mountable not acceptable. t)Marking CE, BIS, ROHS u) All certificates copy to be submitted. v)Three year warranty. Battery rack : Painted MS angle iron rack Suitable for the battery supplied.
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD134759/2025-2026:Supplying and fixing 4 pole Sheet steel enclosure on surface/racess along with 63A,4pole isolator complete with connections testing and commissioning etc.as required.
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
Bidder Name
Sajju T
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1354479.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
MOM.pdf
Tender Documents • 0.19 MB
BOQ_1354479.xls
BOQ • 0.31 MB
viewnit.pdf
Tender Documents • 0.03 MB
viewsbd.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid