Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 CrAdmitted-Finance | ₹1.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.4 CrAdmitted-Finance | ₹1.4 Cr | L3 | Admitted-Finance |
| 4 | L4₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L4 | Admitted-Finance |
| 5 | L5₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bajaj Electricals Limited L6 | TECH MARTZ PLUS L3 | Modern Stage Service L5 | Leksa Lighting Technologies Private Limited L1 | Kavery Electricals L4 | MIDAS ELECTRICALS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00WORK NAME | |||||||||
| 1.01 | Supply, Installation, Testing and Commissioning of an 8 Channel DMX Booster/Splitter, suitable for professional architectural and façade lighting control applications. The unit shall operate on 240V AC, 50 Hz main input supply and provide amplified, isolated DMX signals to ensure reliable performance over extended distances. It shall have 1 male XLR input port for data signal and 8 female XLR output ports, each provided with individual channel output indicators for easy monitoring and troubleshooting. The splitter shall be capable of driving data output lengths up to 50 meters per channel using 14/36 SWG cable, ensuring seamless DMX signal distribution. The unit shall be housed in a robust enclosure designed for long-term durability, with overall dimensions of approximately 485mm (W) x 140mm (L) x 50mm(H) and weight of about 3.5 kg. The system shall guarantee stable operation at 50 Hz frequency and provide full compatibility with DMX512 and related lighting protocols. The scope of work shall include supply of the complete DMX splitter unit, connection accessories, proper mounting at designated control locations, wiring and integration with existing lighting systems, testing of functionality, and commissioning of the entire system as per specifications and directions of the Engineer-in-Charge. | 1 | Nos. | 47,903 ₹47,903 | 35,870 ₹35,870 | 53,100 ₹53,100 | 25,224.59 ₹25,224.59 | 34,472 ₹34,472 | 16,500 ₹16,500 |
| 1.02 | Supply, Testing, and Commissioning of a portable DMX512 Address Writer, suitable for on-site addressing and parameter configuration of intelligent LED lighting fixtures. The device shall be equipped with an LCD display for easy operation and housed in a durable aluminum alloy enclosure.The unit must support multiple power options, including a DC 12V-24V input, a Micro USB DC 5V input compatible with power banks, and an internal rechargeable lithium battery providing a minimum of 6 hours of use from a 3-hour charge. It shall feature a single data output port capable of driving at least 1920 channels and support multiple signal types including RS-485, 5V-TTL, and 12V-TTL. Core functionalities must include writing and checking DMX addresses, setting fixture parameters, and running diagnostic tests with a variety of built-in animations. The device must support a comprehensive range of DMX512 and TTL compatible ICs. The unit shall have an IP20 rating and an operational temperature range of -15°C to 50°C. Approximate physical dimensions shall be 173mm x 88mm x 38.5mm. The scope of work includes the supply of the complete address writer unit with all necessary accessories, a full functional demonstration, and commissioning, including operational training for site personnel as directed by the Engineer-in-Charge | 1 | Nos. | 24,325 ₹24,325 | 1,51,999 ₹1.5 L | 35,400 ₹35,400 | 21,593.89 ₹21,593.89 | 25,931 ₹25,931 | 32,000 ₹32,000 |
| 1.03 | Supply, Installation, Testing, and Commissioning of a programmable Smart DMX Interface, suitable for professional architectural and multi- zone façade lighting control applications. The unit shall operate on a 5-
5.5V DC 0.6A input power, supplied via a compatible AC/DC Power Supply Unit. It shall provide control for a minimum of two DMX512 universes in both live and stand-alone modes , with the capability of being expanded to four universes through software upgrades.The interface must feature an intuitive backlit keyboard with 10 direct access preset buttons. Key connectivity shall include USB Type-C and Ethernet for programming and control , standard XLR3 connectors for DMX output , and a 20-Pin IDC socket providing 16 dry contact trigger ports. The controller must support stand-alone operation via an onboard microSD memory card and be capable of managing up to 99 scenes across 5 zones. Advanced features must include a real-time clock and calendar with sunrise/sunset triggering functions and remote control capabilities over a network.The unit shall be housed in a compact enclosure with approximate dimensions of 160mm x 90mm x 45mm and a weight of about 268g. The scope of work shall include the supply of the complete DMX interface, all necessary connection accessories, a suitable power supply, proper mounting at the designated control location, wiring and integration with the DMX lighting system, programming of scenes as per project requirements, functional testing, and final commissioning of the entire system as per the directions of the Engineer-in-Charge. | 1 | Nos. | 1,24,360 ₹1.2 L | 2,58,400 ₹2.6 L | 1,12,100 ₹1.1 L | 1,28,988.16 ₹1.3 L | 2,59,298 ₹2.6 L | 1,35,000 ₹1.4 L |
| 1.04 | Supply, Installation, Testing and Commissioning of 50W LED Flood Light suitable for outdoor architectural and area lighting applications, with die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 24VDC/140–270VAC, 50–60Hz with power factor >0.90 and THD <15%; The fixture shall deliver a luminous flux ≥2500 lm with luminous efficacy ≥50 lm/W in RGBW colour output; provided with PC/PMMA optics having 25° beam angle(customizable as per site requirement) ensuring uniform illumination The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent with rated life ≥50,000 hours at junction temperature≤85°C (maximum allowable 90°C); integrated driver with DMX512/RDM protocol, surge protection device 4kV (optional 10kV), and reliable performance within -10°C to +50°C operating temperature; overall dimensions approx. L300mm x W.146 x H.87mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge. | 30 | Nos. | 13,461 ₹4.0 L | 17,784 ₹5.3 L | 21,240 ₹6.4 L | 14,003.24 ₹4.2 L | 11,150 ₹3.3 L | 10,850 ₹3.3 L |
| 1.05 | Supply, Installation, Testing and Commissioning of LED Linear Wall Washer of 40W power consumption, with dimensions 1030mm x 48mm x 99mm(±10% tolerance, subject to manufacturer’s design), suitable for outdoor façade and architectural lighting applications. The luminaire shall have an extruded aluminium body with die-cast end caps, powder-coated finish, IP66 protection and IK07 impact resistance, designed to withstand harsh weather conditions. It shall operate on 100–280 VAC, 50/60 Hz input voltage with power factor≥0.90 and THD ≤15%. The fixture shall deliver a luminous flux of ≥2000 lm with luminous efficacy ≥50 lm/W in RGBW colour output. Optical system shall be of high-efficiency PC/PMMA material with 15° x 30° beam angle (customizable as per site requirement). The LED light source shall be from reputed makes such as Osram/Seoul/Refond/Lattice Power/Bridgelux or equivalent, with a rated life of ≥50,000 hours at junction temperature ≤85°C. The fitting shall include inbuilt driver with DMX512/RDM protocol, surge protection of 4kV (optional 10kV), capable of reliable performance within -10°C to +50°C operating temperature and 0–95% humidity. The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge. | 55 | Nos. | 10,869 ₹6.0 L | 15,808 ₹8.7 L | 21,240 ₹11.7 L | 16,724.82 ₹9.2 L | 12,966 ₹7.1 L | 9,950 ₹5.5 L |
| 1.06 | Supply, Installation, Testing and Commissioning of 50W LED Flood Light suitable for outdoor architectural and area lighting applications, with die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 24VDC/140–270VAC, 50–60Hz with power factor >0.90 and THD <15%; The fixture shall deliver a luminous flux ≥2500 lm with luminous efficacy ≥50 lm/W in RGBW colour output; provided with PC/PMMA optics having 60° beam angle(customizable as per site requirement) ensuring uniform illumination The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent with rated life ≥50,000 hours at junction temperature
≤85°C (maximum allowable 90°C); integrated driver with DMX512/RDM protocol, surge protection device 4kV (optional 10kV), and reliable performance within -10°C to +50°C operating temperature; overall dimensions approx. L300mm x W.146 x H.87mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions
of the Engineer-in-Charge. | 12 | Nos. | 13,802 ₹1.7 L | 16,720 ₹2.0 L | 21,240 ₹2.5 L | 14,003.24 ₹1.7 L | 11,150 ₹1.3 L | 14,850 ₹1.8 L |
| 1.07 | Supply, Installation, Testing and Commissioning of LED Fog Lamp Light of 15W power consumption, suitable for outdoor architectural and area lighting applications. The luminaire shall have a die-cast aluminium housing with powder-coated finish, IP66 protection and IK07 impact resistance, designed to withstand harsh outdoor conditions. It shall operate on 24VDC input voltage with power factor
≥0.90 and THD ≤15%, incorporating an inbuilt driver with DMX512/RDM decoder and surge protection device of minimum 3kV (optional up to 10kV). The fixture shall deliver a luminous flux of ≥375 lm with luminous efficacy ≥25 lm/W in RGBW colour output, with optical system of polycarbonate lenses providing a 30° beam angle (customizable as per site requirement) ensuring uniform illumination. The LED light source shall be from reputed makes such as Osram/Seoul/Refond/Lattice Power or equivalent, with a rated life of
≥50,000 hours at junction temperature ≤90°C. The fitting shall perform reliably within -10°C to +50°C operating temperature and 0–95% humidity, with overall luminaire dimensions of approximately Dia.
75.5mm x H. 54mm (±10% tolerance, subject to manufacturer’s design). The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge. | 30 | Nos. | 9,726 ₹2.9 L | 8,968 ₹2.7 L | 8,850 ₹2.7 L | 10,403.33 ₹3.1 L | 5,187 ₹1.6 L | 6,500 ₹1.9 L |
| 1.08 | Supply, Installation, Testing and Commissioning of 50W LED Flood Light suitable for outdoor architectural and area lighting applications, with die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 100–280VAC, 50–60Hz with power factor >0.90 and THD <10%; The fixture shall deliver a luminous flux ≥6500 lm with luminous efficacy ≥100 lm/W in 3000K mono colour output; provided with PC/PMMA optics having 10° beam angle (customizable as per site requirement) ensuring uniform illumination. The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent with rated life ≥50,000 hours at junction temperature ≤85°C (maximum allowable 90°C); integrated driver with ON/OFF operation, surge protection device 4kV (optional 10kV), and reliable performance within -10°C to +50°C operating temperature; overall dimensions approx. L300mm x W.146 x H.87mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge. | 140 | Nos. | 10,334 ₹14.5 L | 7,296 ₹10.2 L | 10,620 ₹14.9 L | 13,627.12 ₹19.1 L | 5,965 ₹8.4 L | 10,350 ₹14.5 L |
| 1.09 | Supply, Installation, Testing and Commissioning of 50W LED Flood Light suitable for outdoor architectural and area lighting applications, with die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 100–280VAC, 50–60Hz with power factor >0.90 and THD <10%; The fixture shall deliver a luminous flux ≥6500 lm with luminous efficacy ≥100 lm/W in 3000K mono colour output; provided with PC/PMMA optics having 60° beam angle (customizable as per site requirement) ensuring uniform illumination. The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent with rated life≥50,000 hours at junction temperature ≤85°C (maximum allowable 90°C); integrated driver with ON/OFF operation, surge protection device 4kV (optional 10kV), and reliable performance within -10°C to+50°C operating temperature; overall dimensions approx. L300mm xW.146 x H.87mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge. | 75 | Nos. | 10,779 ₹8.1 L | 5,472 ₹4.1 L | 10,620 ₹8.0 L | 13,627.12 ₹10.2 L | 5,965 ₹4.5 L | 12,980 ₹9.7 L |
Updated dates
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
12 Jan 2026, 9:00 amClosed
commissioner
nagar nigam kota
Electrical beautification and facade illumination work at Mahatma gandhi maharani historical buildings lakhi burj and gantaghar in Rampura kota
2025_DLB_519583_1
NNK/ELECTRIC/2025/71-78
Open Tender
Electrical Works
180 days
kota
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
commissioner
₹6.0 L
Yes
nagar nigam kota
9 Feb 2026
11 Dec 2025
12 Jan 2026
11 Dec 2025
12 Jan 2026
11 Dec 2025
19 Dec 2025
Supply, Installation, Testing and Commissioning of an 8 Channel DMX Booster/Splitter, suitable for professional architectural and façade lighting control applications. The unit shall operate on 240V AC, 50 Hz main input supply and provide amplified, isolated DMX signals to ensure reliable performance over extended distances. It shall have 1 male XLR input port for data signal and 8 female XLR output ports, each provided with individual channel output indicators for easy monitoring and troubleshooting. The splitter shall be capable of driving data output lengths up to 50 meters per channel using 14/36 SWG cable, ensuring seamless DMX signal distribution. The unit shall be housed in a robust enclosure designed for long-term durability, with overall dimensions of approximately 485mm (W) x 140mm (L) x 50mm(H) and weight of about 3.5 kg. The system shall guarantee stable operation at 50 Hz frequency and provide full compatibility with DMX512 and related lighting protocols. The scope of work shall include supply of the complete DMX splitter unit, connection accessories, proper mounting at designated control locations, wiring and integration with existing lighting systems, testing of functionality, and commissioning of the entire system as per specifications and directions of the Engineer-in-Charge.
Supply, Testing, and Commissioning of a portable DMX512 Address Writer, suitable for on-site
addressing and parameter configuration of intelligent LED lighting fixtures. The device shall be equipped with an LCD display for easy operation and housed in a durable aluminum alloy enclosure.The unit must support multiple power options, including a DC 12V-24V input, a Micro USB DC 5V input compatible with power banks, and an internal rechargeable lithium battery providing a minimum of 6 hours of use from a 3-hour charge. It shall feature a single data output port capable of driving at least 1920 channels and support multiple signal types including RS-485, 5V-TTL, and 12V-TTL. Core functionalities must include writing and checking DMX addresses, setting fixture parameters, and running diagnostic tests with a variety of built-in animations. The device must support a comprehensive range of DMX512 and TTL compatible ICs. The unit shall have an IP20 rating and an operational temperature range of -15°C to 50°C. Approximate physical dimensions shall be 173mm x 88mm x 38.5mm. The scope of work includes the supply of the complete address writer unit with all necessary accessories, a full functional demonstration, and commissioning, including operational training for site personnel as directed by the Engineer-in-Charge
Supply, Installation, Testing, and Commissioning of a programmable Smart DMX Interface, suitable for professional architectural and multi- zone façade lighting control applications. The unit shall operate on a 5- 5.5V DC 0.6A input power, supplied via a compatible AC/DC Power Supply Unit. It shall provide control for a minimum of two DMX512 universes in both live and stand-alone modes , with the capability of being expanded to four universes through software upgrades.The interface must feature an intuitive backlit keyboard with 10 direct access preset buttons. Key connectivity shall include USB Type-C and Ethernet for programming and control , standard XLR3 connectors for DMX output , and a 20-Pin IDC socket providing 16 dry contact trigger ports. The controller must support stand-alone operation via an onboard microSD memory card and be capable of managing up to 99 scenes across 5 zones. Advanced features must include a real-time clock and calendar with sunrise/sunset triggering functions and remote control capabilities over a network.The unit shall be housed in a compact enclosure with approximate dimensions of 160mm x 90mm x 45mm and a weight of about 268g. The scope of work shall include the supply of the complete DMX interface, all necessary connection accessories, a suitable power supply, proper mounting at the designated control location, wiring and integration with the DMX lighting system, programming of scenes as per project requirements, functional testing, and final commissioning of the entire system as per the directions of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of 50W LED Flood Light suitable for outdoor architectural and area lighting applications, with die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 24VDC/140–270VAC, 50–60Hz with power factor >0.90 and THD <15%; The fixture shall deliver a luminous flux ≥2500 lm with luminous efficacy ≥50 lm/W in RGBW colour output; provided with PC/PMMA optics having 25° beam angle(customizable as per site requirement) ensuring uniform illumination The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent with rated life ≥50,000 hours at junction temperature≤85°C (maximum allowable 90°C); integrated driver with DMX512/RDM protocol, surge protection device 4kV (optional 10kV), and reliable performance within -10°C to +50°C operating temperature; overall dimensions approx. L300mm x W.146 x H.87mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of LED Linear Wall Washer of 40W power consumption, with dimensions 1030mm x 48mm x 99mm(±10% tolerance, subject to manufacturer’s design), suitable for outdoor façade and architectural lighting applications. The luminaire shall have an extruded aluminium body with die-cast end caps, powder-coated finish, IP66 protection and IK07 impact resistance, designed to withstand harsh weather conditions. It shall operate on 100–280 VAC, 50/60 Hz input voltage with power factor≥0.90 and THD ≤15%. The fixture shall deliver a luminous flux of ≥2000 lm with luminous efficacy ≥50 lm/W in RGBW colour output. Optical system shall be of high-efficiency PC/PMMA material with 15° x 30° beam angle (customizable as per site requirement). The LED light source shall be from reputed makes such as Osram/Seoul/Refond/Lattic
e Power/Bridgelux or equivalent, with a rated life of ≥50,000 hours at junction temperature ≤85°C. The fitting shall include inbuilt driver with DMX512/RDM protocol, surge protection of 4kV (optional 10kV), capable of reliable performance within -10°C to +50°C operating temperature and 0–95% humidity. The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of 50W LED Flood Light suitable for outdoor architectural and area lighting applications, with die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 24VDC/140–270VAC, 50–60Hz with power factor >0.90 and THD <15%; The fixture shall deliver a luminous flux ≥2500 lm with luminous efficacy ≥50 lm/W in RGBW colour output; provided with PC/PMMA optics having 60° beam angle(customizable as per site requirement) ensuring uniform illumination The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent with rated life ≥50,000 hours at junction temperature ≤85°C (maximum allowable 90°C); integrated driver with DMX512/RDM protocol, surge protection device 4kV (optional 10kV), and reliable performance within -10°C to +50°C operating temperature; overall dimensions approx. L300mm x W.146 x H.87mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of LED Fog Lamp Light of 15W power consumption, suitable for outdoor architectural and area lighting applications. The luminaire shall have a die-cast aluminium housing with powder-coated finish, IP66 protection and IK07 impact resistance, designed to withstand harsh outdoor conditions. It shall operate on 24VDC input voltage with power factor ≥0.90 and THD ≤15%, incorporating an inbuilt driver with DMX512/RDM decoder and surge protection device of minimum 3kV (optional up to 10kV). The fixture shall deliver a luminous flux of ≥375 lm with luminous efficacy ≥25 lm/W in RGBW colour output, with optical system of polycarbonate lenses providing a 30° beam angle (customizable as per site requirement) ensuring uniform illumination. The LED light source shall be from reputed makes such as Osram/Seoul/Refond/Lattice Power or equivalent, with a rated life of ≥50,000 hours at junction temperature ≤90°C. The fitting shall perform reliably within -10°C to +50°C operating temperature and 0–95% humidity, with overall luminaire dimensions of approximately Dia. 75.5mm x H. 54mm (±10% tolerance, subject to manufacturer’s design). The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of 50W LED Flood Light suitable for outdoor architectural and area lighting applications, wit
h die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 100–280VAC, 50–60Hz with power factor >0.90 and THD <10%; The fixture shall deliver a luminous flux ≥6500 lm with luminous efficacy ≥100 lm/W in 3000K mono colour output; provided with PC/PMMA optics having 10° beam angle (customizable as per site requirement) ensuring uniform illumination. The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent with rated life ≥50,000 hours at junction temperature ≤85°C (maximum allowable 90°C); integrated driver with ON/OFF operation, surge protection device 4kV (optional 10kV), and reliable performance within -10°C to +50°C operating temperature; overall dimensions approx. L300mm x W.146 x H.87mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of 50W LED Flood Light suitable for outdoor architectural and area lighting applications, with die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 100–280VAC, 50–60Hz with power factor >0.90 and THD <10%; The fixture shall deliver a luminous flux ≥6500 lm with luminous efficacy ≥100 lm/W in 3000K mono colour output; provided with PC/PMMA optics having 60° beam angle (customizable as per site requirement) ensuring uniform illumination. The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent with rated life≥50,000 hours at junction temperature ≤85°C (maximum allowable 90°C); integrated driver with ON/OFF operation, surge protection device 4kV (optional 10kV), and reliable performance within -10°C to+50°C operating temperature; overall dimensions approx. L300mm xW.146 x H.87mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of 100W LED Flood Light suitable for outdoor architectural and area lighting applications, with die-cast aluminium housing and powder-coated finish, IP66 protection and IK08 impact resistance; operating on 100–280VAC, 50–60Hz with power factor >0.90 and THD <10%; The fixture shall deliver a luminous flux ≥10000 lm with luminous efficacy ≥100 lm/W in 3000K mono colour output; provided with PC/PMMA optics having 10° beam angle (customizable as per site requirement) ensuring uniform illumination. The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power or equivalent with rated life≥50,000 hours at junction temperature ≤85°C (maximum allowable 90°C); integrated driver with ON/OFF operation, surge protection device 4kV (optional 10kV), and reliable performance within 0°C to+50°C operating temperature; overall dimensions approx. L299mm xW.199 x H.168mm (±10% tolerance, subject to manufacturer’s design); The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions
of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of LED Round Flood Light of 25W power consumption, suitable for outdoor architectural and area lighting applications. The luminaire shall have a die-cast aluminium housing with powder-coated finish, inbuilt visor, IP66 protection and IK07 impact resistance, designed to withstand harsh weather conditions. It shall operate on 100–280VAC, 50–60Hz input voltage with power factor ≥0.90 and THD ≤10%. The fixture shall deliver a luminous flux of ≥2000 lm with luminous efficacy ≥80 lm/W in 3000K mono colour output. Optical system shall be of PC/PMMA material with 7° beam angle (customizable as per site requirement) ensuring uniform illumination. The LED light source shall be from reputed makes such as Osram, Seoul, Refond, Lattice Power, Bridgelux or equivalent, with a rated life of ≥50,000 hours at junction temperature ≤85°C (maximum allowable 90°C). The fitting shall include inbuilt driver with ON/OFF operation and surge protection device, capable of reliable performance within -10°C to +50°C operating temperature and 0–95% humidity. The overall dimensions of the luminaire shall be Dia.181mm x H.162mm (±10% tolerance, subject to manufacturer’s design). The scope of work shall include complete supply of all accessories, mounting arrangements, necessary IP-rated connectors (to ensure warranty validity), wiring connections, installation at site, testing of functionality, and commissioning as per specifications and directions of the Engineer-in-Charge.
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Part A (RUIDP SOR 2023) P/laying P.V.C /XLPE insulated & P.V.C. sheathed cable of 1.1 k.v. grade with armoued aluminum conductor of IS 1554 P-1/7098 P-I of Group I of approved make in ground as per IS : 1255 including excavation of 30 cm x 75 cm size trench, 25 Cm thick under layer of sand, 11nd class bricks covering, refilling earth compaction of earth making necessary connection testing etc. as required of size Group-I 10sqmx4core.(Armoured)
6sqm x 4core
25sqm x 3.5core (Armoured)
95 sqmm x 3.5 core
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, aluminium lugs duty crimped with crimping tool, PVC tape etc for following size of armoured PVC insulated & PVC sheathed XLPE aluminium conductor cable of 1100Volt grade as required of size. 4core x 10.0sqmm.
4 x 6.0 sq.mm
3.5 core x 25.0 sq.mm
3.5 core x 95 sqmm
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVCpipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.5 sq.mm x 3 core
4 sq.mm x 4 core
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper/Bimetallic lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 3 x 2.5 sq.mm
4 x 4.0 sq.mm
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1KV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 1x4.0 sq.mm. Group 1
1x6.0 sq.mm. Group 1
1 x 10.0 sq.mm
1 x 16.0 sq.mm
P/F Nut & Bolts.
S & F of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures of following sizes. 320 x 640 x 179 mm
SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required. 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
250 Amp , 25 kA, adjustable O/L & adjustable S/C setting
up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
SITE of Wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, duly treatd for derusting in 7 tank process with dephosphating and with power coating on both side of panel in desired shade. The panel having PU/neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate M.S. base channel hinged door with locking arrangement for equipment/switchgear thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. Channel if required. Side walls and cable alley compartment having bolted type doors with detachable extension type structure.(Only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator)
P&F paper phenolic resin bonded laminates comfirming to IS :2036-1995 for boxes/frames including making holes for switches fet, with brass screws, washers/zinc plated nut and bolts as required. 9.0mm thick.
Supply and fixing of aluminium/copper bus bar by means of SMC/DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolytic grade aluminium bus bar.
Plate Earthling as per IS: 3043 with G.I Earth plate of size 600 mm x 600 mm x 6.0 mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia G.I. “B” Class watering Pipe including all accessories like nut bolt reducer nipple wire meshed funnel and C.C. finished chamber covered with hinged type with locking arrangement C.I Cover C.I Frame of size 300 mm x 300 mm complete with alternate layers of salt and coke/ charcoal testing of earth resistance as required.
S&F laying following size earth wire/ in horizontal or Vertical run in ground/ surface/ recess including riveting, soldering, saddles, making connection etc. as required. 10 SWG G.I. ( Hot Dipped ) Wire
GI strip 25mmx3mm( Hot Dipped)size.
P&F of mechanical/ digital time switch having following day/ week programme and min. 100 hous reverse and AC1 rating of 16 to 20 amp including making connections, programming rtc. As reqd . 1 day reverse (mech. Type) Group1
P&F 240/415V AC MCB with positive isolation of breaking capacity not less than 10KA (B/C/D tripping characteristic) ISI marked IS 8828(1996)1/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as reqd. Four pole MCB 80 A rating. Group 1
Single pole MCB 6A to 32A rating Group1
P&F 240/115 V isolator conforming to IS: 13947-111/ IEC 60947-3 on existing board/ sheet including making connections, testing etc. As required Four pole isolator 63 A rating Group1
P&F of ac operated heavy duty 230/440 Volt power contactor conforming to IS:13947-4-1/EC;947-4-1having provision of mechanical interlocking Din rail mounting type including making connections testing etc. as required. 3 pole power contractor with following AC3 Rating 95 Amp
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.Red/yellow/Green colour Group1
Blue colour
S&F following sizes (dia) of ISI marked medium duty PVC conduit along with accessories in surface/ recessed using saddles, clamps, fastener as required including cutting the wall covering conduit and making good the same as required 25mm
P & F Recessed / Surface Mounting heavy duty horizontal type sheet steel Distribution board Phophatised/powder painted complete with suitable rating insulated copper bus bar, shorting link, neutral link, earth link, and din bar, masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs testing etc. as required. Double door Three phase 8 way
Metal door (single phase) 12 way
Metal door (three phase ) 4 way
Providing and Fixing of IP65 Protectd polycarbonate/ polysterene fuse box moulded with inside knock outs of following size with hinged cover, trasparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20mmx3mm flat with nut and bolts, complete with. The box shall be provided with Din rail, 4/8way 10.0/16.0 sq.mm heavy duty connector, earth terminal, complete in all respect.225mmx225mmx100mm
P/L of Double wall corrugated HDPE pipe confirming to IS:14930 P-I&2 with HDPE coupler at 1mtr Depth below the ground for laying cable and back filling the trench, conpaction of earth as required of Gemini or IS:14930 marked make outerDia/Inner dia. 50/55mm
S & Laying following size B Class GI pipe confirming to IS:1239 P-1 (1990) with accessories for laying earth conductror/strip/cable in ground/surface/recess as required 100mm dia.
Supply & fabrication steel structure with ms channel/ angle/joist/ISMB/sheet etc. including welding rivetting cutting nut & bolt painting etc as required.
Providing and laying in position cement concrete including curing compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work upto plinth level. 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size).
Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished :20mm thick
Supplying and fixing of CE certified and UL listed GI wire mesh cable tray made from spot welded steel wire hot dipped galvanised between 60 and 80 microns of zinc as per BS 729 including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods, etc. as required of following sizesAll as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 200 mm x 50 mm x 6 mm
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3 core 185.0 Sq.mm
Add Extra for Laying of one number XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground including excavation of trench of size 120 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
Add Extra in Item no. 62.3 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
Providing and laying lime Dhar on roofing as per Rajasthan, Jaipur traditional practice with lime, Surkhi, old lime powder, brick aggregate 12 to 20mm (1:2:2:2) and using Methi, Gur, Hemp, Belgiri etc. including beating and temping 100 to 150mm thick as per specifications.Including dismantling of old detoriated roofing
Providing & applying Lime kara1:2 (1lime cream:2 Zikkipowder) grinding mortar with grinding mill /manually on lime base, on ceiling and all flat surface in two coats. First coat applying 3mm to 4mm thick and curing properly at least 7days, second finishing coat done after 7 days of previous coat as per traditional practice.(thickness not more than 6 mm.)
Aluminium T or L sections
Part B ( BSR 2023) Providing experienced and Highly skilled/skilled/ semi-skilled/Un Skilled labour for electric repair/ maintenance / operation of Air conditioning/Air cooling/Fire fighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as per requirement (one shift of 8 Hrs per day for 26 Working Days in a month) 1 skilled Labour (5 Years)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.11 MB
BOQ_926844.xls
BOQ • 0.42 MB
bid.pdf
Tender Documents • 24.41 MB
Download all tender documents and submit your bid