| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC H 123 GYAN MANDIR ROAD GALI NO 3 JAITPUR EXTENSION BADARPUR NEW DELHI 110044 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110044 | L1 | Accepted-AOC Ist Lowest | |
| 2 | L2₹44.2 L+₹4.5 L (11.4%)Rejected-Finance BASEMENT B 724 SADARJUNG ENCLAVE NEW DELHI 110029 | SOUTH | DELHI | 110029 | L2 | Rejected-Finance 2 | |
| 3 | L3₹46.8 L+₹7.2 L (18.1%)Rejected-Finance NONE | L3 | Rejected-Finance 3 | |
| 4 | L4₹48.3 L+₹8.6 L (21.8%)Rejected-Finance 15 119 DAKHINPURI NEW DELHI 110062 | SOUTH | DELHI | 110062 | L4 | Rejected-Finance 4 | |
| 5 | L5₹55.4 L+₹15.8 L (39.8%)Rejected-Finance 0 DOGRA CHOWK JEWEL JAMMU JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L5 | Rejected-Finance 5 |
Tender Value
₹70.3 L
EMD Value
₹1.4 L
Closing Date
24 Feb 2026, 3:00 pmClosed
Executive Engineer (E)
O/o The Executive Engineer (E) South Elect. Div., PWD, Sukhdev Vihar, Mathura Road, Near Okhla Flyover, New Delhi
Repair and renovation of vacant/liveable staff. Accommodations (29 Nos.) in DPSRU, M.B Road, Pushp Vihar, New Delhi.
2026_PWD_287141_1
161/EE(E)/EMD South Elect. Divn./PWD/2025-26
Open Tender
Electrical Works
Works
180 days
New Delhi
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹1.4 L
Yes
7 Apr 2026
17 Feb 2026
24 Feb 2026
17 Feb 2026
24 Feb 2026
17 Feb 2026
Sub Head - I (Wiring Work)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required (a) Group A
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel / PVC conduit as required.
a) 3 X 1.5 sq.mm
b) 6 X 1.5 sq.mm
c) 3 X 4 sq.mm.
d) 6 x 4 sq. mm
e) 3 X 6 sq.mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required
6 Module (200mmX75mm)
12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required
Supplying and fixing of 3mm thick phenolic laminated sheet i/c cutting the sheet as per required size etc. complete as required.
Sub Head - II (Fittings & Fixtures)
Supplying, installation, testing and commissioning of 900 rpm 300mm sweep exhaust fan complete with louvers/ shutters in the existing opening i/c making the hole to suit the size of the above fan making good the damage & connections etc. complete as reqd.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying and fixing two module stepped type electronic fan regulator on the existing piano type including connections but excluding piano plate etc. as required
LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Supplying and replacement, installation, testing & commissioning of 250 mm sizes white body Sweep PVC body Fresh Air Ventilator Exhaust fan with louver shutter in the existing opening of toilet room/kitchen etc i/c connection with 1.5 sqmm FRLS PVC insulated wires and fibre sheets etc as reqd.
SITC of Decorative, wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base etc complete as required.
S/I/T/C of 5 Lts. Capacity storage Geysers with following specification :- Mount type – Vertical Type – Storage Water Heater Capacity – 5 Lt. Energy rating – 5 Star Technology – Sale care Technology Temperature Controller – Adjustable Controller Bar Pressure – 8 Wattage – 2000 W Voltage – 230 V Frequency – 50 Hz Rate Max. Temp -75 Degree Outer Body – MS Insulation – PUF Heating Element Incoloy - 800
S/I/T/C of 25 Lts. Capacity storage Geysers with following specification :- Mount type – Vertical Type – Storage Water Heater Capacity – 25 Lt. Energy rating – 5 Star Technology – Sale care Technology Temperature Controller – Adjustable Controller Bar Pressure – 8 Wattage – 2000 W Voltage – 230 V Frequency – 50 Hz Rate Max. Temp -75 Degree Outer Body – MS Insulation – PUF Heating Element Incoloy - 800
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement i/c timer for on/off timing system with connection etc. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
S/I/T/C of weatherproof box made out of hot moulded SMC sheet with clamp, neutral link, strip, gland, thimble and 1 No. 10 Amps. SP MCB complete with inter connection, earthing etc as reqd.(Box Size: 300mm X 200mm X 105mm)
Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .
Supplying, installation, testing & Commissioning of Surface/Wall Mounted 1 X 10W LED Tube With 2 feet MS Batten Fitting, LED Tube should have extruded aluminium housing for efficient heat dissipation. Total system Lumen of 10W Led should be 1700 or above in Cool day Light(5700K to 6500K), Power factor>0.90, CRI>80. Complete with Mounting Brackets & accessories as required with connections etc. complete as reqd
SITC of wall mounted cabin fan 450 mm sweep suitable for operating on 230 volt single phase AC supply i/c connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable earth etc as reqd.
Rebate for unserviceable electrical items like assorted wire, fittings, fans and conduiting MS box etc. (For Type I Qtr)
Rebate for unserviceable electrical items like assorted wire, fittings, fans and conduiting MS box etc. (For Type II Qtr)
Rebate for unserviceable electrical items like assorted wire, fittings, fans and conduiting MS box etc. (For Type III Qtr)
Rebate for unserviceable electrical items like assorted wire, fittings, fans and conduiting MS box etc.
Sub Head - III (Panel, DB & Cabling)
Replacement of floor mounting compartmentallised cubical panel board minimum 200 mm depth with locking arrangement front openable, totally enclosed, dust & vermin proof fabricated out of 2mm thick cold rolled carbon annealed, sheet steel, with suitable incoming Amp 4 strip Al. bus bar, cable alley on both sides, powder coated paint of approved shade and 2 nos 25x5mm copper strips throughout the width of panel consisting of two earth studs on each strip complete with following incoming and outgoing switchgears including making connections/ inter connections with lugs/ thimble for switchgears and control wiring with 2.5 sq.mm PVC insulated FRLS copper conductor cable, including providing 50mm X 50mm X 6 mm thick Angle base upto 300 mm above ground level including necessary grouting / fixing on floor ( Drawing shall be got approved from Engineerincharge before fabrication(all MCCB's shall have spreader link & rotory handle) complete etc as required (1 Sq,Mt X 4 Nos. = 4 Sq.Mt)
Supply & fixing of following accessories in the existing cubical type M.S. panel board i/c drilling holes in cubical panel, making connections etc as reqd.
63 A, SPN RCCB
125 A, 16 KA,TPMCCB
Digital Ammeter Three phase
Digital Volt Meter Three phase
LED type indicating light (RYB)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
16 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single pole
Single pole and neutral
Supplying , Laying and fixing following size of PVC insulated and PVC sheathed al. conductor armoured power cable of 1.1 KV grade of following ways as reqd.
(a) 3 x 10 sq.mm. cable on surface
(b) 4 x 16 sq.mm cable on surface
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3 X 10 sq. mm (22mm)
4 X 16 sq. mm (28mm)
Supply & Fixing of 80 X 50 mm PVC Channel along with accessories in surface of wall etc s required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Sub Head - IV (Air Conditioners)
Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature)
2.0 TR with 5 Star BEE Rating
1.5 TR with 5 Star BEE Rating
Supply , Installation, Testing and Commissioning of Automatic Line voltage correctors and wall mounted type for domestic use, copper wound complete with the voltmeter to indicate input voltage rating with auto cut off and time delay relay complete as required a) Capacity 5.0 KVA.
Providing and fixing of refrigerant copper pipe of (5/8" & 1/4" size) suitable for 2 TR capacity split type AC unit i/c installation of refrigerant pipe with 1/2" thick (N.S) nylon insulation pipe covered with 50mm dia PVC flexible pipe etc. complete as required.
Providing and fixing MS angle iron frame made out of 35mm X 35mm X 5mm (N.S) of size 900mm X 300mm X 150mm(N.S) i/c painting suitable for mounting of 2.0 Ton capacity split AC out door unit complete etc. as reqd.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
stage.html
html • 0.05 MB
technical_380395.pdf
techsummary_380395.pdf
finance_380395.pdf
BOQ Comparative Chart
xlsx
finsummary_380395.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
BOQ_380395.xls
BOQ • 0.35 MB
NIT.pdf
Tender Documents • 2.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .