Loading…
Loading…
Tender Value
₹7.5 Cr
EMD Value
₹15.1 L
Closing Date
1 Jul 2026, 3:00 pm6d left
Similar tender results from the same govt authority in the past 3 years.
EXECUTIVE ENGINEER BUILDING DIVISION MOTIHARI
E E
E E BUILDING DIVISION MOTIHARI
Superintending Engineer, BUILDING CIRCLE MOTIHARI
SE
CONSTRUCTION OF 03 (THREE) Nos. PANCHAYAT SARKAR BHAWAN IN VILL - KARARIYA MAUJA - KARARIYA, VILL - BARHARWAKALA PASCHIM MAUJA - BARHARWA KALA AND VILL- BHOPATPUR UTTARI MAUJA - BHOPATPUR AT BLOCK KOTWA IN THE DIST - EAST CHAMPARAN FOR THE YEAR - 2026-27.
133260
RE NIT 8/BCD/MOTIHARI/2026-27
Open Tender
CIVIL
Purbi Champaran
• Name of the contractor
Address of the contractor
• Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given.
Total Bid Security Amount in Rupees Rs. 1509800.00
• (i) Legal Status of Bidder
(ii) Place of Registration.
(iii) write Principal place of Business
(iv) Power of attorney of signatory Bid
• Total value of civil engineering construction work, in Rupees, Performed in last five years. minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work of at least the equal to the 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year Rs. 37744545.50
2020-21
2021-22
2022-23
2023-24
2024-25
• Amount in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost Rs. 37744545.50
• Minimum Quantities of work done as prime contractor in any one year during last five years, units shall be same as in Requirement column
Items Qty Unit
E/W 1426.815 cum
BRICK WORK 559.14 cum
PCC / RCC 922.455 cum
TILE & FLOORING 1345.16 M2
PHE 17,09,113.00 Rs in Lac
Electrical Work 21,23,365.00 Rs in
Lac
Furniture 0.00 Rs in
Lac
Fire Fighting 89,250.00 Rs in
Lac
• Electrical License The contractor or his identified sub-contractor should possess required valid electrical license for executing the building electrification works and should have executed similar electrical works for a minimum amount as indicated in Appendix in any one year
• (a) Amount of Existing commitments and ongoing works in Rupees
(b) Amount of Work for which Bid already submitted, in Rupees
• Numbers and Maximum age of Equipments with bidder Type of Equipment Nos. Maxm. Age
Concrete Mixer with Integral weigh Batching facility 2 5
Water Tanker 1 5
Steel shuttering 3000 sft 5
Vibrator (Plate & Niddle) 4 5
• Name of the Personnel and Experince in years and Select from drop down list Personnel / Qualification
Site Engineer / B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 1 No.
Site Supervisor /Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 2 No.
• Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of credit facilities (10% of estimated cost), certified by bankers (for work under this bid). Proposed methodology and programme of construction Select from drop down list the proposed methodology and programme of construction, backed with equipment planning and deployment Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct.
• Undertaking Select from drop down list. Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract.
• Time of Completion 12 Months
• Registration No.
IT.& GST
Labour License
Character Certificate
NOC for Debar (If required)
CIVIL
PERCENTAGE
L1
1
16 documents required · 16 mandatory
₹10,000
Processing Fee: 5900
₹15.1 L
AT OFFICE OF SE BCD, MOTIHARI
6 Jun 2026
6 Jun 2026
2 Jul 2026
6 Jun 2026
1 Jul 2026
6 Jun 2026
15 Jun 2026
Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. All kinds of soil
Filing Earthwork in Approach road and Entrance and flanke without rolling with power roller
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth : consolidating each deposited layer by ramming and watering lead.
Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 1:2:4 ( 1 Cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
Brick work with bricks of class designation 100A in foundations and plinth in :
Providing and laying in position specified grade of reinforced cementconcrete excluding the cost of centring,shuttering,finishing andreinforcement-All work puto plinth level. 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate20 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufactures.
Centring and shuttering including strutting, propping etc. and removal of form for:
Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength and admixtures in recommended proportions as per IS: 9103 to celerate,reinforcement,durability as per direction of Engineer-incharge. all work upto plinth
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth and superstructure
Extra for Brick work in superstructure above plinth level upto floor II cum
Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class teak wood. 50 x 20 mm
Providing and fixing steel glazed doors, windows and ventilatrs of standard rolled steel sections, joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6(1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with woodenplugs and screws or raw) plugs and screws or with fixing dips or with bolts and nuts as required, including providing and fixing of glass panes with glazing dips and special metal-sash putty pf approved make complete including applying a priming coat of approved steel primer; excluding the cost of metal beading and other fitting except necessary hinges or pivots as required.
Providing and fixing pressed steel door frame confirming IS code 4351 manufactured from commerical mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by . mechnical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb.
Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
Providing and fixing hand rail by welding etc. to steel ladder railings & staircases railing including applying a priming coat of approved steel primer. MS tube (medium) 40 mm nominal dia
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer
Providing designation 100 A one brick edge soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
Providing and laying vitrifed floor tiles in different sizes {thickness to ben specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joint with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm.
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand ) 20 to 25 mm thick
Kota stone slabs 20 mm thick in risers of steps skirting. Dado & pillars laid on 12 mm (average (thick cement mortar 1:3 (1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Details of cost for 10 sqm
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Chequerred precast cement concrete tiles 22 mm thick with marbie chips of size 6 mm in footpath & coutyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning tec. Complete on 20 mm thick bed of cement mortar 1:4(1 cement:4 coarse sand). Medium shade using 50% white cement 50% grey cement
Providing 12 mm cement plaster of mix. 1:6 (1 cement : 6 coarse sand)
Providing 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a. floating coat of neat cement
Providing 15 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
6 mm cement plaster to ceiling of mix.1:4 (1 cement : 4 coarse sand)
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including priming coat with cement primer.
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on woodwork (hard and soft wood)
With ready mixed red oxide zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.Two or more coats on new work
Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 Ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm)
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions. (ii) 2nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand)mixed with water proofing compound in recommended proportion, (iii) 3rd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area, (iv) 4th course of 400 micron thick PVC sheet.(Overlaps at joints of PVC shet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqni).
Grading roof for water proofing treatment. Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical imulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete. With chlorpyriphos / Lindane E.C. 20% with 1% concentration.
Along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% Concentration.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand ) to match the existing floor. With chlorpyriphos / Lindane E.C. 20% with 1% concentration.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m all kind of soil
Clearing jungle including uprooting of rank vegetation ,grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Providing and fixing brass stop cock of approved quality (screwed end).
Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end).
Providing and fixing gun metal non-return valve of approved quality (screwed end). Horizontal. 32mm nominal bore
Providing and fixing uplasticised PVC connectionpipe with brass ions 45 cm length. 15 mm nominal bore
Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS stamdards and weighing notless than 810 gms. 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.. 15 mm nominal bore
Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931. 15mm nominal bore
Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved quality conforming to IS: 8931. 15mm nominal bore
Cutting holes up to 30 x 30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks
Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete . Flexible pipe. 40 mm dia
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete.
Providing and fixing 600 x 120 x 5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc. complete
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm an effective height of 88 mm, weighthan 190 gms
Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110mm diameter
Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete. 110mm
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside)with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 100A
Providing and fixing water closet squatting pan (Indian type W.C pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa Pattern W.C pan of size 580x440mm with integral type foot rests.
Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. W.C pan with ISI marked white solid plastic seat and lid.
Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S 13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board. 510x1040 mm bowl depth 250 mm
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than 105gms.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass lush pipe,spreaders with unionsand clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I.trap with outlet grating and other couplings in C.P. brass, includingpainting of fittings and cutting and making good the walls and floors .wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 90 gms.
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes inlcuding bed concrete as per standard design.. 150mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design. Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron concrete (1: 4:8), over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 Metre depth below ground level.All types of soil. 400 mm dia.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 Metre & upto 150 Metre depth below ground level. All types of soil. 300 mm dia.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 Metre & upto 150 Metre depth below ground level. All types of soil. 400 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge. V. 150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia,conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed /plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).150 mm dia.
Supply, Installation, testing & Commissioning of 2HP submersible pump all complete
Supply Testing installing and commisioning of ISI marked 4.5 kg capacity crbon dioxide type including valve hose reel with provision of wall bracket fixed with anchor fasteners all complete job.
Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable size G.I box etc. as required. Group - 'C'
Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable size G.I box etc. as required. Group - 'B'
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (for On switch board)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular switch box including connection but excluding modular plate etc. as required.
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc, as required.
Supplying and fixing 2 pin, 5 amp. ceiling rose on the existing junction box/PVC box including connection etc as required.
Supplying and fixing batten/angle holder including connection etc. as required.
Supplying and fixing Ding-Dong call bell suitable for single phase, 230 volts complete as required.
Supplying and fixing following modules G.I. box along with modular base and cover plate for modular switches in recess etc as required.
1 or 2 module (75mm X 75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
Supplying and fixing following way three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)
Supplying and fixing following rating, 240 volts, ‘C’ series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Providing and fixing following capacity 4 pole On-load/panel mounted changeover switches in existing cubicle panel board, making connection, earthing the body etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supply of following sizes and core XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cble of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Description/items
SOR Ref
Total=
S.O.R Refere
Cleaning of grass & Rubbish from the Site…. Etc.
Earth work in excavation in foundation trenches or drains (not exceding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottom, lift upto 1.5 m including getting out the excavated soil and disposal of surplus soil as directed within a lead of 50m. All kind of soil.
E/w Back filling in Foundation Trenches
Supplying and filling in plinth with local sand and under floots including watering, ramming consolidating and dressing complete.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1 : 6 (1 Cement : 6 Coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1 : 6 (1 Cement : 6 Coarse sand) Extra for Brick work in Superstructure above Plinth level upto V Floor.
Cement concrete works( PCC )
Providing and laying in position reinforced cement concrete of specified grade excluding the cost of centring and shuttering all work up to plinth level 1:1:2 (1 cement: 1 coarse sand: 2 grade stone aggregate of 20mm nominal size.)
Reinforced Cement concrete work in wall (any thickness) including attached pilasters, buttresses, plinth and string courses, pillars,pires,abutments, post (1:1:2 ) etc.
Reinforced Cement concrete work in Beams suspended floors, roofs having slope upto15, landing, balconies, shelves,chajjas,lintels, band plain,windows sill,staircases upto floor five level excluding the cost of 1 cement 1 course sand: 2 graded stone aggregate,20 mm nominal size).
Kg/ Cum
( A ) R C C work in Footing including straititing, cutting, bending, binding & placing in position etc. all Complete.
Shuttering for Foundation including strutting ,propping etc, and removable or form work for Foundation, footing,bases column
Centering And Shuttering for Band
Centering & Shuttering for stiffners
PLASTER WORK
12 mm Plaster 1:3 with cement punning
One Brick flate solng joints filled with Local sand
Providing & Laying 80 mm thick factory made paver block of M-30. grade made by block made vibratory compaction... Etc . All Complete as the direction of Engineer-in -charge.
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade new work (Two or more coats)
Providing and fixing 1 mm Thick M.S Sheet doors with frame of 40X40X6 mm angle iron and 3 mm ms gusset plates at the junction and corner all necessary fittings complete, includingapplying priming coat of approved steel primer.
With ready mixed Zinc chromate yellow primer.
Painting with synthetic enamel paint Two or more coats over an under coats
Total (H) =
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
CHECKLIST.pdf
NIT • 1.76 MB
NIT-08-2026-27 Re-Tender KOTWA PSB.pdf
NIT • 2.42 MB
SBD KOTWA PSB.doc
NIT • 0.64 MB
GR-01. BOQ OF KOTWA PSB.xls
NIT • 2.28 MB
Download all tender documents and submit your bid