The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The Tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Definition of similar work: Supply, installation, testing and commissioning of overhead transmission line work of 11 KV & above
Tenderer shall submit a copy of valid Electrical Contractor License (issued by state government or other government authority) and Valid Supervisory Certificate of Competency for Supervision of HT work (33 KV or above) and workmen License for all the Electrical works mentioned in the schedule till the completion of the entire work. The contractor's supervisor or engineer in charge should always be present at site during execution of work.
40 conditions · 9 needing a document upload
Whether cost of earnest money deposited.
Whether cost of tender document deposited.
Whether valid electrical contractor license and valid supervisor license submitted.
Whether Documents related to technical eligibility submitted.
Whether documents related to financial eligibility submitted.
Due to implementation of GST by government of India with effect from 01-07-2017, All the Bidder / Tenderers are advice to ensure that they are GST compliant and their quoted tax structures/rates are as per GST law. The quoted rate should include all applicable taxes as per GST law and no claims will be entertained after the closing date of the tender.
In case the successful tenderer is not liable to be registered under CGST / IGST / UTGST / SGST act. The Railway shall deduct the applicable GST from his / Their Bills under Reverse Charge Mechanism (RCM) and deposit the same to the concerned tax authority
Those tenderer/bidder who wish to get payment through LC are requested to follow the related rules mentioned in tender contract documents. For getting payment through letter of Credit (LC) and uploading duly filled up as per Annexure - O & Annexure P, attached with the tender documents.
Address of Firm: The tenderer should upload scanned copy in PDF format of the complete address of the Firm to which all correspondences shall be made by Railways.
Payment of Earnest Money Deposit (EMD) & Tender Documents Cost (TDC) in respect of e - tendering, should be accepted through net banking or payment gateway only.
GSTIN: The tenderer should upload scanned copy in pdf format of the GSTIN in favor of the company.
Before execution of the work, the bidder has to submit all drawings, sketches, electrical item's list etc. for necessary approval from competent authority.
Other Letter: The tenderer may upload scanned copy in PDF format of anyother letter/ documents etc., the agency intends to submit.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Diversion & modification of HT (33KV & 11KV) and LT line across and along the railway track at different locations between Aluabari Road Junction & Thakurganj railway station, Thakurganj & Siliguri Junction railway station & Siliguri Junction & New Jalpaiguri railway station for clearing electrical infringement with proposed double line.
E-C-N-S-02-26-27-DL
E-C-N-S-02-26-27-DL
Open
Works - General
12 Months
Jalpaiguri, West Bengal
₹0
₹15.0 L
22 Jul 2026
30 Jun 2026
8 Jul 2026
188 items across 6 schedules · ₹7,50,46,399 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | To conduct survey of the locations of HT (33KV & 11KV) infringement and submit drawings showing plan, elevation, CSD & BOQ of present HT track crossing & modified/diverted HT line etc prepared in AutoCad or similar platforms. Approval to be obtained from concerned SEB officials after approval of Railways (open line/Construction/RailTel). All coordination with NBPDCL for approval of drawings shall be done by the contractor. Two set drawings of every location shall be submitted to Railways after final approval. | Kilometre | 6.00 | 4,354 | 26,124 |
| 2 | "Supply of Galvanized steel swaged tubular pole 14.5 mtr long, type 410 SP-76 with step length 6.5-4.00-4.00 mtr., sectional dia 219.1 x 193.7 x 165.1 mm, sectional thickness 5.9 x 4.85 x 4.5 mm as per IS 2713 - 1980 including suitable size of CI base plate & it's fastener and GI cap on the top (Pole should be galvanized through hot dip galvanization process as per IS). Make: Skipper/BPP/JK/UTKARSH." | Numbers | 40.00 | 41,961 | 16,78,440 |
| 3 | Supply of galvanized steel tubular pole 12 mtr long type 410SP-66 with step length 5.80-3.10- 3.10 mtr sectional dia 219.1x193.7x165.1 mm sectional thickness 5.9x4.85x4.5mm as per IS 2713-1980 including suitable size of CI base plate & it's fastener and GI cap on top (Pole should be galvanized through hot dip galvanization process as per IS). Make: Skipper/BPP/JK/UTKARSH. | Numbers | 46.00 | 28,810 | 13,25,260 |
| 4 | Erection of tubular pole 12/14.5/16 Mtr.long including digging the pit 1/5th. of total length. | Numbers | 86.00 | 610 | 52,460 |
| 5 | Supply and execution of CC foundation work in ratio 1:3:6 by cement,sand and chips of size 19mm & down. The size of the CC block will be 30cm dia with height upto the pole depth below GL and 30Cm above GL including tie muffing of DP. | cum | 21.50 | 2,060 | 44,290 |
| 6 | Supply & erection of 2P composite polymer 33 KV ball & socket type Disc insulator ( 90 KN) with minimum creepage distance 900mm & sectional length 510mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rodand sealed to the hot dipped galvanised carbon steelend fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or asper IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting. Make: Rly/NBPDCL approved | Numbers | 54.00 | 2,708 | 1,46,232 |
| 7 | Supply & erection of 2P composite polymer 33 KV Pin insulator (10 KN) with minimum creepage distance 980mm & sectional length 415 mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731(1971) & 2488 (Pt-II) 1974 complete with hardware fitting. Make: Rly/NBPDCL approved | Numbers | 87.00 | 1,652 | 1,43,724 |
| 8 | Supply & erection of 2P composite polymer 11 KV ball & socket type Disc insulator ( 70 KN) with minimum creepage distance 320 mm & sectional length 300 mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rodand sealed to the hot dipped galvanised carbon steelend fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or asper IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting. Make: Rly/NBPDCL approved | Set | 18.00 | 730 | 13,140 |
| 9 | Supply & erection of 2P composite polymer 11 KV Pin insulator (10 KN) with minimum creepage distance 340mm & sectional length 235 mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731(1971) & 2488 (Pt-II) 1974 complete with hardware fitting. Make: Rly/NBPDCL approved | Numbers | 99.00 | 509 | 50,391 |
| 10 | Supply & erection of 11 KV Gang Operated Air breakoff load disconnecting switch - 400 Amp 3 pole rocking type each pole consist of galvanised steel base, HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate sections to break magnetising current of the transformer horizontal GI pipe of adequate length for phase separation and 25mm dia, 3.65mm thickness GI pipe of adequate length for operation from ground level and operating handle complete in both ON & OFF positions. Make: Rly/NBPDCL approved | Set | 2.00 | 10,405 | 20,810 |
| 11 | Supply and erection of 11KV DO fuse double stack channel type 200 Amps capacity. Make: Rly/NBPDCL approved | Set | 2.00 | 6,560 | 13,120 |
| 12 | Suply and erection of Zinc Oxide Station Class-I lightning arrestor suitable for 3 wire 33KV with rated voltage 30KV(RMS) and a normal discharge current rating of 10KA as per IS:4004 (1985), complete with galvanised clamping arrangement, GI bolts, nuts, washer etc. (3 Nos in a set). Make: Raychem/Oblum/Lamco/Elpro | Set | 6.00 | 25,490 | 1,52,940 |
| 13 | Supply and erection of 3 Nos station class - 1 Zinc oxide Lightening arrestor suitable for 3 wire 11 KV OH with rated voltage 9 KV (RMS) with normal discharge current rating of 10 KA and complete with galvanized clamping arrangement, GI bolts, nuts, washer as required conforming to IS 3070-III-1993. Make: OBLUM/REYCHEM/LAMCO/Elpro | Set | 10.00 | 15,658 | 1,56,580 |
| 14 | Supply, stringing & binding of ACSR conductor Wolf of size 30/7/2.59 mm conforming to IS : 398-Pt.II-1976 | Metre | 1710.00 | 203 | 3,47,130 |
| 15 | Supply, stringing & binding of ACSR conductor Dog of size 6/4.72+7/1.57 mm conforming to IS : 398-Pt.II-1976 | Metre | 2931.00 | 123 | 3,60,513 |
| 16 | Supply & stringing, binding of GI wire 8 SWG for guarding | Metre | 1547.00 | 4 | 6,188 |
| 17 | Supply & stringing, binding of GI wire 10 SWG for lacing | Metre | 3094.00 | 3 | 9,282 |
| 18 | Supply & erection of Galvanised stay set for HT (33KV & 11KV) OH line comprising of 20 mm dia with 1.8 mtr long stay rod, anchor plate of size 30x30cmx6mm/45x45x7.5mm, turn buckle (20mmx600 mm), 20mm thimble , stay clamp, 7/10mm dia GI stay wire, Guy strain insulator of size 85 x140 mm as per ref. IS 5300/1969, and cc foundation with ratio 1:3:6 including excavation, refilling etc. | Set | 86.00 | 1,011 | 86,946 |
| 19 | Supply & erection of danger board size 8"x6" on GI clamp made of 20x3mm for 33/11 KV showing the voltage grade, skull symbol etc. | Numbers | 38.00 | 32 | 1,216 |
| 20 | Supply & erection of barbed wire upto height 2.5m to be fixed on pole with 2 nos. of clamps of suitable size and as per direction of Engineer Incharge at site. | Numbers | 86.00 | 165 | 14,190 |
| 21 | Dismantling of over head alignment like conductor, insulator, bracket etc and handing over to concerned Rly/NBPDCL authority including loading, unloading, transportation etc with contrctor's own liability & cost. | Each Span | 30.00 | 167 | 5,010 |
| 22 | Uprooting of existing pole without damaging the bottom of the pole etc and handing over to concerned Rly/NBPDCL authority including loading, unloading, transportation etc with contrctor's own liability & cost. | Numbers | 65.00 | 275 | 17,875 |
| 23 | Supply & laying of class LA type CI/DI pipe 150 mm dia of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989 or latest amendment of IS/ISS/IEC 1.5 m below ground level as per direction of Engineer In charge at site | Metre | 198.00 | 1,326 | 2,62,548 |
| 24 | Supply & laying of class LA type CI/DI pipe 300 mm dia of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989 or latest amendment of IS/ISS/IEC 1.5 m below ground level as per direction of Engineer In charge at site | Metre | 33.00 | 3,488 | 1,15,104 |
| 25 | Horizontal boring of size 100/150/200/250/300 mm dia hole across railway embankment / Road at a depth of 1.5Mtr below GL by HDD Machine at Contractor's own arrangement as per direction of Engineer in charge at site. | Metre | 230.00 | 5,697 | 13,10,310 |
| 26 | Horizontal boring of 250/400mm dia hole across Railway embankment/Road at a depth of 1.5 mtr below GL by turning a pointed instrument at contractor's own arrangement as per direction of Engineer In Charge at site. | Metre | 21.00 | 222 | 4,662 |
| 27 | Supply and erection of earthing by 50 mm GI pipe IS:1239/1990 (Pt-I) of 3.60mm thickness 3mtr long including construction of earth pit, RCC earth cover slab with filling/mixing of salt, charcoal etc of required quantity and earth continuty by 25x3mm GI strip with GI nuts bolts washer etc. including welding, earth resistance flag etc. | Numbers | 48.00 | 1,718 | 82,464 |
| 28 | Supply and laying of additionalGI Strip including suitable size hole, GI nuts & bolts, washer or welded in joints wherever required as per direction of Engineer in charge at site of size 25 mm x 6 mm | Metre | 120.00 | 50 | 6,000 |
| 29 | Supply and laying of HDPE pipe of size 4 inch (110mm outside dia), 6kgf/cm2, 6.0 mtr each length, PE-100 Grade conforming to IS : 4984/1995. Make:SWASTIK/SUPREME/NATRAJ PIPES/SKIPPER/SINTEX/SUDHAKAR/AJA Plus | Metre | 216.00 | 268 | 57,888 |
| 30 | Supply & fixing of GI channel size 100x50x50x6mm bracket of suitable length clamped with above pole made by GI flat 50x5mm with 50x16mm GI bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting. As required as per direction of Engineer in charge/NBPDCL. | Metre | 106.00 | 869 | 92,114 |
| 31 | Supply & fixing of GI channel size 75x40x40x6mm bracket of suitable size clamped with pole made by GI flat of size 50x5mm with 50x16mm bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting as per direction of Engineer in charge/NBPDCL | Metre | 70.00 | 372 | 26,040 |
| 32 | Supply & fixing of GI angle size 65x65x6mm bracket of suitable sizes clamped with above pole made by GI flat 50x5mm with 50x16mm GI bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting. As per direction of Engineer in charge/NBPDCL | Metre | 340.00 | 269 | 91,460 |
| 33 | Construction of cable trench of desired depth below the ground level for laying cable/pipes as per direct laying method and direction of site Engineer and filling & compacting of trench with soil with watering and ramming after laying of cable and disposal of garbage form site within a distance of 50 mtr. | cum | 80.00 | 417 | 33,360 |
| 34 | Supply and laying of standard Bricks as per procedure for cable protection | cum | 5.00 | 2,403 | 12,015 |
| 35 | Supply and laying of stranded circular aluminium conductor , conductor screened with excluded semiconducting compound, XLPE insulated , installation screened with excluded semi conduction compound in combination with copper tape (0.3 KA for 1 sec), round wire steel armoured , over all PVC sheathed (A2XWY) 33 KV (E) grade 3 core 400 sqmm size cable conforming to IS : 7098-II-2011 with latest amendment. for laying below GL as per direction of Engineer incharge at site complete with crimping socket grommet etc. make: Havells/ polycab/finolex/RPG cables/RR kables. | Metre | 316.00 | 12,176 | 38,47,616 |
| 36 | Supply and laying of stranded circular aluminium conductor , conductor screened with excluded semiconducting compound, XLPE insulated , installation screened with excluded semi conduction compound in combination with copper tape (0.3 KA for 1 sec), round wire aluminium armoured , over all PVC sheathed (A2XWaY) 33 KV (E) grade Single core 630 sqmm size cable conforming to IS : 7098-II-1985 with latest amendment. for laying below GL as per direction of Engineer incharge at site complete with creeping socket grommet etc. make: Havells/ polycab/finolex/RPG cables/RR kables. | Metre | 346.00 | 6,530 | 22,59,380 |
| 37 | Supply and laying of stranded circular aluminium conductor , conductor screened with excluded semiconducting compound, XLPE insulated , installation screened with excluded semi conduction compound in combination with copper tape (0.3 KA for 1 sec), round wire steel armoured , over all PVC sheathed (A2XWY) 11 KV (E) grade 3 core 300 sqmm size cable conforming to IS : 7098-II-1985 with latest amendment. for laying below GL as per direction of Engineer incharge at site complete with crimping socket grommet etc. make: Havells/ polycab/finolex/RPG cables/RR kables. | Metre | 853.00 | 7,042 | 60,06,826 |
| 38 | Supply, fixing, fitting and testing of heat shrink outdoor termination kit for HT 11KV XLPE cable with required sockets/studs etc as per standard procedure of 3 core 300 Sqmm sizes as per Raychem model no EPKT-3372 or similar Make: MS SEAL/ Multi Pressing/ Reychem or Similar | Numbers | 20.00 | 35,020 | 7,00,400 |
| 39 | Supply, fixing, fitting and testing of heat shrink outdoor termination kit for HT 33KV XLPE cable with required sockets/studs etc as per standard procedure of 3 core 400 Sqmm sizes as per Raychem model no EPKT-6374 or similar Make: MS SEAL/ Multi Pressing/ Reychem or Similar | Numbers | 8.00 | 79,645 | 6,37,160 |
| 40 | Supply, fixing, fitting and testing of heat shrink outdoor termination kit for HT 33KV XLPE cable with required sockets/studs etc as per standard procedure of 1 core 630 Sqmm sizes as per Yamuna cable accessories Pvt Ltd model no XSOS-34 or similar Make: MS SEAL/ Multi Pressing/ Reychem or Similar | Numbers | 8.00 | 14,020 | 1,12,160 |
| Schedule total | ₹2,03,29,368 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender doc
ATTACHMENT
SPECIAL TERMS AND CONDITIONS
ATTACHMENT
PV.pdf
ATTACHMENT
GCC-2022_.pdf
ATTACHMENT
TenderDocumentHT-LT-AUB-TKG-SGUJ-NJP.pdf
ATTACHMENT
SpecialTermsandconditionHT-LTAUB-TKG-SGUJ-NJP.pdf
ATTACHMENT
ACS1to10.pdf
ATTACHMENT
ACS11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .