Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC 00 IN FRONT OF SHIVPURI HOTEL NEAR KOTHI NO 14 SHIVPURI MADHYA PRADESH 473551 | SHIVPURI | MADHYA PRADESH | 473551 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.1 L+₹61,561 (2.41%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹27.4 L+₹1.9 L (7.37%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹27.5 L+₹2.0 L (7.89%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹27.9 L+₹2.4 L (9.22%)Rejected-Finance PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
6 Feb 2023, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
SPECIAL REPAIR TO P-7 CLUB HOUSE (MES COMPLEX) AND STATIC WATER TANK AT NAVAL BASE PORBANDAR UNDER GE NAVY PORBANDAR
2023_MES_574074_1
9160/PBR/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹54,000
Yes
3 Apr 2023
10 Jan 2023
8 Feb 2023
10 Jan 2023
6 Feb 2023
24 Jan 2023
10 Jan 2023 - 23 Jan 2023
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
PCC 1:2:4 type B1(using 20mm graded stone aggregate) as in Well steining and well curbs etc complete all as specified and directed by Engr-in-Charge.
MS framed work such as grills, gratings, etc with ends of bars shoulders or riveted or forged in to spikes, framed guard bars , rungs ,screen and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and as directed.
Mild steel screw bolts with 11 to 15mm diameter neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22. 5cm but n exc 30cm long, complete all as specified and as directed.
1.25 mm Thick Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) welded to framed complete all as specified and as directed.
40mm (Width of flaps (when open) in mm) Continuous (piano) hinges,mild steel, bright finish or electro galvanised complete all as specified and directed.
PCC 1:2:4 type B-1 using (12.5 mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, drain beds kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, and similar work including use & waste of necessary form work complete all as specified and as directed.
Rendering 15 mm thick on fair face of brick work or concrete surfaces or stone masonry surfaces or surface in CM 1:4 finished even and smooth without using extra cement complete all as specified.
Preparation of newly plastered surfaces and applying three coats of white wash as in wall complete all specified and directed.
Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of Epoxy paint over a coat of epoxy primer etc, complete all specified and directed.
Cleaning and removal all scale and dirt etc from static tank and from mouth of circulationg pipes etc of service static tank located at different locations of capacities as following: (Note: The contractor will write date of cleaining and due date of cleaning on static water tank as directed by Engr in charge. (2) At the time of cleaning all pipes/fittings should be make in good condition as directed by Engr in charge.
(a) Static tank Capicity 25000 litres
(b) Static tank Capicity 50000 litres
Preparing of new or prioviously untreated steel surfaces, n exc 10cm width or girth when unconnected with other painting or when painted in different tint, including washing and cleaning etc, and applying 2 coats of synthetic enamel paint over a coat of priming paint plaster coat complet all as specified and as directed.
Preparation of plastered wall surfaces incl necessary racking with wire brushes to remove all loose laitence & washing with clean water, crack filling with acrylic putty as directed on site, wetting the wall surfaces prior to coating and applying 1 primer coat of Dr fixit Primeseal incl crack filling with Dr Fixit Crack 'X' Paste & allow to dry for 4 hours, on internal walls, applying damp proof coating and blend a mixture with water in the ratio 1:1:1(Base: Hardner: Water) & applying 2 coats over the plastered surface in a span of 4 hrs and applying matching decorative finish complete all as specified and directed.
Complete removal of existing treatment on wall surfaces incl necessary taking down and wirebrush the surfaces to remove existing paint & putty, snowcem etc on external wall and crack filling with Dr Fixit Crack 'X' Paste and wet the wall prior to coating, Apply Dr. Fixit PrimeSeal (50% Dilution ) and allow to dry for 4-6 hours. Finally apply 2 coats of Dr. Fixit Raincoat undiluted, with an approximate time interval of 6 hours intravals (Each coat time duration is 6 hrs) complete all as per manufacturer's instructions and applying two coats of exterior weather proof paint matching with surrounding surfaces complete all as spd and as directed by Engineer-in-Charge of work.
Cutting out tress with roots in brick/slab roof surfaces (accessible & inaccessible roofs) with necessary chemical treatments incl filling with PCC B0 (1:2:4) 12mm graded stone aggregates with water proofing chemicals complete all as specified and directed by Engineer-in-Charge.
Dismantling of floor hearth and wall tilling incl mortar beding removing serviceable tiles to store and rubbish off the premises as complete all as specified and directed by the Engr-in-Charge
Non-skid ceramic tiles, coloured with 2 mm to 3 mm spacer bar (of approved colour, shade and design) of tiles non skid of 400mmx400mm x 7 to 8mm thick (area exceeding 0.11 Sqm but not exceeding 0.18 Sqm), as in floors, etc.set and jointed in neat cement slurry and pointed with white cement mixed with pigment including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Glazed ceramic tiles, coloured (light colour as approved) of size 300x 600 x7mm/ 350x250mm x 7mm / 450X 350X 7mm x300mmx200mmx7mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 10mm thick rendering in cement mortar (1:4) and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified
Vitrified Ceramic tiles 600mm x 600mm x 9-10mm thick, Light shade coloured (square/ rectangular) area of each tiles exc 0.18 sqm but not exceeding 0.36 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured epoxy grout to match , over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 complete all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid dry beded in any mortor complete all as specified.
Granite 20mm thick machine cut, bedded andjointed as in cills, jambs, steps and the like with grey cement slurry and pointed with white cementwith admixture of pigment to match the shade of granite stone including grinding and polishing, etc with 15mm thick screed in cement mortar (1:4) complete all as specified.
20mm thick Granite machine cut, in skirting/dado door window sill, jambs etc laid over cement screed (1:3) and jointed with grey cement slurry, and pointed with white cement with admixture ofpigment to match the shade ofgranite stone including grinding and polishing complete all as specified.
Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, Complete all as specified and directed.
Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete articles and precast concrete block walling etc. Complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses but except stone complete all as specified and directed.
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Rendering 10 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:6 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately
Rendering 5 mm thick on fair faces of brick work or concrete surfaces as on ceiling surface, facia and projection of slabs, and window projection, in CM 1:3 finished even and smooth without using extra cement complete all as specified.
Prepration of newly plastered surfaces of wall and applying two layer white putty to make the surfaces even & smooth and applying two coats of water based distemper over a coat of primer complete all as specified and directed.
Washing,rubingdown and stoping of distempered and painted surfaces from old plastered/pointed surfaces (dry distember,white / lime wash etc) and Applying two coats of oil bound distemper/water based distemper over a coat of alkali resistant priming paint including applying Providing and applying plaster of paris putty of 1mm thickness over plasterd surface to prepare the surface even and smooth complete all as specified and directed.
Prepration of newly plastered surfaces of ceiling and applying one layer white putty to make the surfaces even & smooth and applying two coats of water based distemper over a coat of primer complete all as specified and directed.
Complete removal of existing treatment from old plastered surfaces of ceilling (dry distember,white/lime wash etc) and Applying two coats of oil bound distember/water based distemper over a coat of primer including applying providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed by Engineer in Charge.
Preparatiion of new plastered surfaces as in walls, soffits & facias of beam, chajjas etc for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as spd and as directed by Engineer in Charge
Preparatiion of old plastered surfaces as in walls, soffits & facias of beam, chajjas & incl roof/floor bottom ceiling portion in etc or applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as spd and as directed by Engineer in Charge
Vitreous China wash down water closet (European pattern) white with connected S-Trap / P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe fixed in repairs complete all as specified and directed.
PVC flushing tank 10 litre capacity syphonic action type, high / low level, valveless, fixed in repair connecting to PVC flush pipe and restoring all connections fixed in repairs complete all as specified and directed.
Fancy type (Vitreous Ceramic ivory or snow white) pedestal patten hand wash basins with full pedestal of size 630x450mm wall with all necessary fittings with fixing arrangements and connecting to water pipe with existing water system etc including suitable pillar tap fixed in repairs complete all as specified and directed.
Toilet paper Holder brass chromium plated with flap guard as in repair complete all as specified and directed by Engineer in charge.
Fancy type stainless steel soap dish,fixed to plugs with chromium plated brass screw fixed in repair / replacement complete all as specified and directed.
Fancy type Chromium plated towel rail, 24mm dia, D type, 60cm long between flanges fixed in repair / replacement complete all as specified and directed.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
ABS body Health faucet with wall hook and 1 metre SS braided rubber holes pipe fixed in repair / replacement complete all as specified.
CP brass wall mixer for mixing hot & cold water with bend pipe for over head shower screwed down for CPVC and fixed as in repair complete all as specified.
15mm bore fancy type CP Stop Cock cock or angle with wall flange fixed in repair / replacement complete all as specified.
Central hole CP Wash hand basin mixer with 450mm braded connection pipe for mixing hot & cold water screwed down for iron pipe and fixed as in repair complete all as specified.
Bib cock brass long nose chromium plated with wall flange and aerator for CPVC pipe and fixed in repair / replacement complete all as specified.
Repairs to CP grating square min 150mm size complete all as secified.
500 Ltr Cap Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with inlet outlet with suitable PVC Float Valve etc connections all as specified in SSR Part I fixed in repair/replacement Complete all as spd and as directed by Engineer in Charge.
Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed for 25mm bore pipe (Minimum weight-455gms) fixed in repair / replacement complete all as specified and directed.
50mm thick Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, floor topping etc, surfaces finished of concrete flooring with brooming / chequred finish complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames exc 1.5 sqm and n.exc 4 Sqm each with shutter (without taking off Shutter) complete all as specified and as directed.
Taking down chowkats or frames n.exc 1.5 Sqm each with shutter (without taking off Shutter) complete all as specified.
Taking down Shutters of any description n.exc 2 sq. m each and removing complete all as specified and as directed.
Factory made 35 mm thick,2nd class hard wood, glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, and fitted to chowkats, kiln seasoned and chemically pressure treated, complete all as specified and as directed.
Factory made 35mm thick, 2nd class hard wood , plain framed, panelled shutters, (two panel) with lock rail and, panels shall be of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and as directed.
Plain solid, straight chowkats and frames of second class hard wood wrought framed rebated on the solid rounded or chamfered, put together with glue pinned at joints Complete all as specified and directed.
18-19mm thick pre-laminated particle board (incl dismantling), flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in cup board shutter , shelves etc including 6 mm thick teak wood leaping on three sides and 20mm thich on hanging side & French polishing to edging complete all as specified.
Fiber glass reinforced plastic (FRP) door frames of three legged cross section 90 x 45 mm having single rebate 32 x 15 mm to receive shutter 30 mm thick, laminated door frame moulded with fire retardent grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block of 2nd Class hardwood in all the three legs. The frame shall be covered with fibre glass from all sides M.S stay shall be provided at the bottom to sedy the frame complete all as specified.
30 mm thick Factory made glass fiber reinforced plastics panelled door (FRP) shutter of colour as approved by GE made with fire retardent grade unsaturated polyster resin,moulded to 3mm thick FRP laminate for forming hollow rails & styles with wooden frame & suitable blocks of seasoned wood inside at required places for fixing of fittings along with MS tube frame of 19 gauge all around the styles & rails duly coated with steel primer cast monolithically with 5mm thick FRP laminate panels & conforming to IS:14856:2000 including fixing to frames and two handles on both sides, 2 Tower Bolts & 3 Hinges to each panel complete all as specified and directed.
300mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified.
150mm long (Length of Bolt in mm) Aluminium anodised,barrel tower bolts of extruded section complete all as specified and directed.
150mm (Size of Handle in mm) Extruded aluminium alloy handles, fabricated type, anodised and fixed in complete all as specified.
100mm Butt hinges(Size of hinges in mm), medium weight, cold rolled, stainless steel complete all as specified.
Hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws complete all as specified.
Stainless steel curtain rod fixing with side brackets, finials on both end of every opening length end cups, etc and fixed with PVC rawl plugs & steel screws as in repairs complete all as specified.
Taking down old u/s Aluminium Window/door sliding section removing from Sliding track incl with all glass /wire mesh fitting complete all as specified and directed by Engineer in Charge
Powder coated three track anodised aluminium frame section of sliding tracking section for windows, ventilation, partion wall cup board with one or more rebates including tracking section of windows cleats for fixing etc. Complete all as specifed.
Powder coated Anodised aluminium window and ventilator shutters, hung/sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
Powder coated aluminium doors of section including chowkat size of door n.exe 2sqm (chowkat 101mmx44mmx2mm wall thickness, stiles,top & lock rail of shutter 80mmx44mmx2mm wall thickness, bottom rail min 90mmx44mmx2mm thick wall thickness) including aluminium hinges, aluminium tower bolts 200mm, aluminium handle 150mm, 4mm thick glass necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading screws & 1 nos hydraulic door closer of aluminium body, mortice lock four levers with two Nos keys complete all as specified and directed.
Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
4mm thick sheet glass, ordinary quality in square n exc 0.5 sq. m in each pane fixed to aluminium windowcomplete all as specified.
Preparation of new or previously untreated wood and wood based materials of any described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all specified and directed.
Preparation of new steel surfaces of any description and applying two coats of epoxy paint over a coat of red oxide primer complete all as specified and as directed.
Preparation of old wooden surfaces and wood based surfaces of any description not other wise described over 10cm width or girth and applying one coats of synthetic enamel paint on old wooden surfaces complete all specified and directed.
Preparation of old decorative steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint on old steel surfaces complete all as sepecified and directed.
Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing, complete all as specified and as directed. Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane cover including testing on completion complete all as specified and directed.
10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, including add WPC @3% of cement weight ( Dr Fixt /Cera /Krishna etc), finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Rate includes WPC & Polymeric membrane will be measured and paid separately)
Plain Cement concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate min radius of 75mm thick as in roof and parapet wall junction , roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, filling rails embedded sec etc incl necessary sloping on roof top surfaces including form work complete all as specified.
Taking up or down existing steel water tubing, 16mm bore alongwith connections fixed/laid in any situation, complete all as specified.
Taking up or down existing steel water tubing, 20mm bore alongwith connections fixed/laid in any situation, complete all as specified.
Taking up or down existing steel water tubing, 25mm bore alongwith connections fixed/laid in any situation, complete all as specified.
16mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
20mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
25mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
Dismantling CI Pipe/PVC along with fitting of 100 mm dia or any size, below or above ground level ,jointed in cement mortar and taking out complete all as specified.
PVC (SWR) pipes, 110mm bore, single socketed, 2.50 Kgf per Sqcm pressure, in any length with rubber ring joints fixed in repair / replacement complete all as specified and as directed.
110mm dia bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips fixed in repair / replacement complete all as specified and as directed.
PVC (SWR) pipes, 75mm bore, single socketed, 2.50 Kgf per Sqcm pressure, in any length with rubber ring joints fixed in repair / replacement complete all as specified and as directed.
75mm dia bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips fixed in repair / replacement complete all as specified and as directed.
PVC (SWR) junction single, (Single T) equal or unequal of nominal bore 110mm fixed in repairs, complete all as specified and directed.
PVC (SWR) junction single, (Single T) equal or unequal of nominal bore 75mm fixed in repairs, complete all as specified and directed.
110mm bore PVC (SWR) vent cowl, complete all as specified and directed.
75mm bore PVC (SWR) vent cowl, complete all as specified and directed.
75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement and white cement complete all as specified and as directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified.
CPVC ball valve for 25 mm bore pipe with long handle, fixing in CPVC pipeline by cutting of pipeline and fixing with necessary fittings and solvent Complete all as specified and directed.
CPVC ball valve for 20 mm bore pipe with long handle, fixing in CPVC pipeline by cutting of pipeline and fixing with necessary fittings and solvent Complete all as specified and directed.
CPVC ball valve for 15 mm bore pipe with long handle, fixing in CPVC pipeline by cutting of pipeline and fixing with necessary fittings and solvent Complete all as specified and directed.
Mild steel work conforming to Fe-290 Gde E-165 as in Hand rails, half round or other stock section or core for wooden hand-rail straight portion, (Posts and Struts in fencing including embedding in concrete etc) drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps, gates wind tie including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work, complete all as specified and as directed by Engineer in Charge.
Framed work ( Fe 410 -W(Gde-E- 250) quality-A)- as in doors or gates of angle or other section with gusset plates, rails, posts, braces, rafters, purlins etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing as in repair complete complete all as spd and directed by Engineer in Charge.
PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation filling mass concrete or in sub base complete all as specified and directed by Engr-in-charge.
Sand filling under paver blocks for cushion incl watering and consolidation to required level and gradient, Complete all as specified and directed.
Machine pressed precast concrete interlocking paver block (coloured) any shape and size conforming to IS 15658-2006 of 60mm thick M-35 grade (with grey cement and pigment) complete all as specified and directed. Note : Sand coushining will be measured and paid seprately.
Demolition of unreinforced concrete of any description and in any position not otherwise specifically provided for cement complete including removing debries ouside MD land all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, PVC boards etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as spd and directed by Engineer in charge.
Gypsum Board 12mm thick 60 x 60 cm ceiling board fixed with screw with and including 25mm X 25mm, Main tee 38mmX23mm ,Sub tee 23mmX23mm aluminium anodised snap grid frame 605X605 mm for false ceiling including hanging arrangement complete all as specified and directed by Engineer in Charge.
Anodised aluminium snap grid frame work for false ceiling Hangers 6 mm dia. G.I. (upto 120mm lengh) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified.
Dismantling Plain or corrugated steel sheeting, any type / gauge, thickness and any pattern of roof coverings, hanger door, hanger roof complete all as specified.
High tensile galvalume sheets colour coated single skin high rib / multi rib TMP Profile Galvalume sheeting in roof or in cladding having 1000-1020 mm width 28 mm high crest @ maximum 250 mm pitch (centre to centre) and minimum 190mm manufactured out of 0.50 mm TCT (total coated thickness) cold rolled steel, having yield strength 550MPa minimum and wall coated with 25 micron modified polyester paint system applied on Zincalume on top and with back coating on sheet shall be 7-10 micron epoxy paint. The sheet shall be supplied in length maximum upto 6-12 meters long to suit with structural dimensions and fixed with self tapping screws with built in gasket (with bitumen washer) of suitable size machine fixed as per manufacturer instructions and applying adhesive compound to joint overlap of sheets complete all as specified and directed by Engineer-in-Charge.
Taking down old point wiring complete for (light,fan,socket 5/15 amps, bell point etc) complete with all light fitttings accessories, such as switches, sockets 5/15 amps, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall , floors, etc all specified and directed by Engineer-in-charge.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade / PVC casing caping of size not less than 20mm width complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following:-
(a) One light or fan point controlled by one one way switch
(b) One ceiling fan/exhaust fan controlled by one way switch
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade / PVC casing caping of size not less than 20mm width complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 5 pin 5 Amps and all as directed at site.
All as per above item No. 117 but One 5 Amps 3/5 pin socket outlet on same board with other switches.
Point wiring with 4 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade / PVC casing caping of size not less than 20mm width complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for one socket outlet 15 Amps on independent all as directed at site.
Modular switch 1 way 6 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Ceiling fan regulator five step 02 module, hum free, AC, 230 volts, 100 watts, fixed in repair / replacement complete all as specified & directed.
Taking down existing ceiling fan / exhaust fan any size, any make, refixing the same after replacing the rubber bushes, split pin, servicing, greasing and painting with two coats of synthetic enamel paint etc complete all as specified and directed.
LED tube light fittings 4 feet 1x20 Watt, 220V, AC Decorative ultra slim polycarbonate LED lighting fixture with high lume output, environmental friendly, energy efficient including LED tube light connecting up with 3 core flexible copper conductor cable with sutable size from ceilling rose fixed in repair/ replacement complete all as directed by Engr-in-charge.
LED tube light fittings mirror type with high output diffuser 2 feet, 1x10 Watt, 220V, AC decorative box type with driver, holder including LED Tube light connecting up with 3 core flexible cpper conductor cable with sutable size from ceilling rese fixed in repair/replacement complete all as directed by Engr-in-charge.
4 Module LED Foot light fittings, 240V white, poly carbonate, fire retardant, UV stabilizer repair/replacement complet all as directed by Engr-in-Charge.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps fixed in repair / replacement complete all as specified and directed.
MCB DB made of sheet steel, powder painted with NUTRAL bus bar neutral link, IP-43-IK09 protection grade, 415V TPN with 4 way double door fixed in repair/replacement complete all as specified and directed.
MCB DB made of sheet steel, powder painted with NURAL bus bar neutral linke, earth bar and din rail, 240V SPN with 8 way double door, IP-43-IK09 protection. Note for item No. 131.00 to 132.00 (1) The rate includes for cutting the brick walls to accommodate DB to make flush to wall/ DB to be fixed on wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surgace. (note-rate is inclusive of cutting chase S & F in replacementin repair lush to wall existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceilling finishes making good disturbed surfaces of wall, etc)
MCB TPN 40 to 63 Amps,10 KA breaking capacity 'C' Curve suitable 240 V,50 Hz for lighting and other domestic load fixed in repairs complete all as specified and directed.
MCB SPN 40 to 63 Amps,10 KA breaking capacity 'C' Curve suitable 240 V,50 Hz for lighting and other domestic load fixed in repairs complete all as specified and directed.
MCB SP 240 Volts AC 6 - 32 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Galvanised earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Sub main wiring concealed with two runs of single core 6 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit / PVC casing caping of size not less than 25mm width complete with including one run of 6 sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. Note : Two wires of 6 Sqmm and one earth wire of 6 Sqmm and one run of PVC casing caping / Conduit shall be measured as one unit.
Supply laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 25 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Double walled corrugated (DWC) HDPE pipe of size 50mm outer dia and 38 mm inner dia conforming ot IS 16205 Part-24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair/replacement complete all as directed by Engr-in-Charge.
Vastushilp Building Designer
BABUBHAI BHIMABHAI PANDAVADRA
J J ENTERPRISES
AADESH CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .