Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.4 LAdmitted-Finance RABINDRA NAGAR SILIGURI 734 006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | -1.00% | ₹7.4 L | L1 | Admitted-Finance |
| 2 | L2₹7.7 LAdmitted-Finance | +1.77% | ₹7.7 L | L2 | Admitted-Finance |
| 3 | L3₹7.7 LAdmitted-Finance | +2.00% | ₹7.7 L | L3 | Admitted-Finance |
Tender Value
₹7.5 L
EMD Value
₹15,039
Closing Date
13 Feb 2026, 3:00 pmClosed
commissioner
Siliguri Municipal Corporation Baghajatin road, Collegepara, Siliguri
Illumination with necessary wiring at Fuleshwari Fish Market at Ward no.28.
2026_MAD_1001213_1
WBMAD/SMC/NIT-60/ELE/25-26
Open Tender
Electrical Work/ Equipment
30 days
Siliguri Municipal Corporation
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹15,039
Yes
11 Mar 2026
7 Feb 2026
16 Feb 2026
7 Feb 2026
13 Feb 2026
7 Feb 2026
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish, Average run 12 mtr (PWD SOR / Page E -14 / Item - 2(g))
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish, Average run 10 mtr (PWD SOR / Page E -14 / Item - 2(e))
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC On Board PWD:- E-10,4(a)
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works 20x10mm Size( PWD:- E-13,10(a))
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works2 Row 12 Module , PWD , E-17,1(e)
Supply of LED lamps 20 W, 2000 Lm (Make:-Philips) Electrical Schedule:- I&WD, Page:-114/ 5.3F.28, 5.3F.28.1
Fixing only lamp PWD:- C-2,11)
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.(PWD SOR / Page D -13/ 22)
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support with out angle iron suppor 150x50x1.25mm (18SWG).(PWD SOR / Page D-14/ 34(a)i)
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support 150x50x1.25mm (18SWG) .(PWD SOR / Page D-15/ b)
Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.150x50x1.25mm (18SWG) (PWD SOR / Page D-15/ c)
Supplying & Erection of mini size feeder pillar box of Size (918 x 561 x 382 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 60/63 A , Make:- Havels (PWD SOR / Page D-01/ b)
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) 4 bars 415 V, 100/125 A Dimension ofAl. bars [85mm long] 4 x 25x5mm Dimension ofSheet Metal Box 500x150mm
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection 100 A
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.Dp, 40A, (PWD SOR / Page D-5/ 6)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.63 A FP, Make:-Legrand(PWD SOR / Page D-01/ b)
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(PWD:- E-6,21)
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex cover and making necessary connections as required (PWD:- E-6,22)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
A.I. SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR UNARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. 2 core aluminium 10 sq.mm cable Make:- Havels/KEI/polycab or equivalent(I&WD Schedule:-page:-101)
A.I. SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR UNARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. 4 ore aluminium 10 sq.mm cable Make:- Havels/KEI/polycab or equivalent(I&WD Schedule:-page:-101)
A.I. SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR UNARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. 4 core aluminium 16 sq.mm cable Make:- Havels/KEI/polycab or equivalent (I&WD Schedule:-page:-101)
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.(PWD SOR / Page F-3/ 6(i))
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 4 way make:-Legrand.(PWD SOR / Page D-10/ 14)
Supply of High Density Poly-ethylene Pipe conforming to IS - 4984 - 1985 (Dia) [PE - 63] A. 6 Kg / Sq.Cm. (Working Pressure) (Dia) 40 mm (PWD Sanitary & Plumbing works 2018 / Page-19 / item 20 A
Labour for fitting and fixing high density poly-ethylene pipes or P.V.C. pipes for above ground work including cost of jointing materials paints etc. fitting and fixing all necessary specials, cutting pipes, making threads, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps(any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. ) (A) Under Ground (v) 40 mm dia. (PWD Sanitary & Plumbing works 2018 / Page-11 / item 18 A )
Supplying and fixing 240/415 V MCB of Breaking capacity 10 kA & C characteristics on din rail of existing DBs and necessary connection : SP 6-32 A (Make : ABB / L&T) (PWD SOR / Page D-6 / Item - 7)
Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 : 300mm sweep RPM 900 / 1400 (12”) (Make : Crompton / Usha / EPC / Havells) (I&WD SOR / page 115 / item 5.3 G.5.3)
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12")(PWD SOR / Page C -4 / Item - 28(b))
Supply of 20 W Single Tube LED Light Set with batten having 220V-240 V, 50 Hz capacity high quality diffuser and high voltage protection with 100 lm/W efficacy incl. making necy. Connections & mending good the damages to original finish etc. as required.. (Make: Philips. Model : LED Batten 20 W or equivalent model of Bajaj / Crompton)
Supply and fixing of smart bright essential street light (70 Watt+5%) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. I&WD 5.3,F.10
Supply and fixing of greenline V2 street light (115+-5% Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. I&WD:- 5.3 F.11
S/F of special head type M S loop box (3 mm thick) with connecting bar and other accessories fixed on the top the pole as required and as per direction of Engineer-In-Charge. For 3 phase connection.
Earthing with 50 mm dia GI pipe , TATA-Medium GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below : By ISI-Medium GI Pipe. [PWD Schedule 2017 (Page - G-1 Item - 2 a)]
Excavation of soil for installation of Earth Electrode and filling (a) For Soft Soil [PWD Schedule 2017 (Page - G-1 Item - 1 a)]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [PWD Schedule 2017 (Page - G-2 Item - 3 a)]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [PWD Schedule 2017 (Page - G-2 Item - 3 b)]
Supply and delivery of clear water verticat w conforming to IS : 8034 ( and as amended thereaiter ) with standard tuOC fo. potable clear cold water and BEE 3 Star Rated.capable of discharging noted M'/h. against head of water column. The pump shall be directly coupled with a continuous rated2- pole suitable wet type vertical squinel cage induction Toto. conforming to IS : 9253 (and as amended thereafter ), suitable for operation in A-C Single phases 220Y,50H2 (category B motor) Minimum Bore well Dia:-75mm, 1 HP,No of Stage:-10,Head (II) in Metre:-28, Discharge(Q) in M3/Hr:-1.8,NRY Size in mm:-32,
Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the fOllowing depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controllerlstarter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.)100/150/200 cubic metre per hour capacity electro motor pumping set.
Supply and delivery of direct on line ( DOL) strater panel board conforming to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (+10%) AC, single phase, 50HZ(+5yo) comprising of ammeter, voltmeter, thermal overload relay,2 pole magnetic contactor, under voltage protection, indicating lamp, capacitors, on/off push buttons including 5 way connector, wiring with l/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities:-I H.P. (Relay Range 6-10 Amp.)(PHE schedule:- page-3,1(i))
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall Direct on Line starter for motor (upto 5 HP) pWD: C-1, 7a
Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required.3 Core 2.5 Sq mm Flat Cable
Supply and Fixing of 2 mm Polyvinyl glow sign board made of 22 SWG GI sheet box with 1”X1” aluminum channel for fixing the vinyl board after necessary cutting the letter as required & s\f LED tube light fittings along with all accessories
Add GST @ 18%
Add Cess @1%
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
BOQ_2453316.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid