Office of Executive Engineer PWD Electrical Division Thiruvananthapuram
HFWD Centrally sponsored SchemeCapacity Building for Developing trauma Care Facilities on National Highways Construction-Providing additional facilities in the Emergency Dept and trauma care Dept attached to MCH,TVM SITC of AC
2019_PWD_322520_2
EDT_ET_217_19
Open Tender
Electrical Works
Item Rate
120 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,700
Executive Engineer
₹18,750
1 Feb 2020
30 Nov 2019
13 Dec 2019
30 Nov 2019
9 Dec 2019
30 Nov 2019
30 Nov 2019 - 9 Dec 2019
Amount
Part-2 SITC OF AC units
od124767/2019_2020 : Supply installation testing and commissioning of the following capacity single phase 3 star rating wall mounting type split air conditioner unit fitted with hermetically sealed compressor, operation on refrigerant R32/Non CFC Suitable for wall/floor mounting conforming to IS 1391 (part II) (amendments - I except Power consumption norms) suitable for operation on 230 V, 50 HZ Single phase AC Supply of performing.:- a. Cooling b. Dehumidifying. c. Air Circulating. D. Filtering. Higher Energy Efficient.:-2.0TR single phase split AC unit including copper pipe connection, electric cabling from out door to indoor unit up to 3 meter complete and code less remote control etc.. The all units comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete.
od125872/2019_2020 : Supply installation testing and commissioning of the following capacity single phase 3 star rating wall mounting type split air conditioner unit fitted with hermetically sealed compressor, operation on refrigerant R32/Non CFC Suitable for wall/floor mounting conforming to IS 1391 (part II) (amendments - I except Power consumption norms) suitable for operation on 230 V, 50 HZ Single phase AC Supply of performing.:- a. Cooling b. De humidifying.c. Air Circulating. D. Filtering. Higher Energy Efficient.:-1.5TR single phase split AC unit including copper pipe connection, electric cabling from out door to indoor unit up to 3 meter complete and code less remote control. The all units comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete.
od116935/2019_2020 : Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge
od118059/2019_2020 : Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
od125906/2019_2020 : Supply and Fixing of 4 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V
od125947/2019_2020 : Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V
od125908/2019_2020 : Supply and fabrication conveyance and installation of angle iron frame work for mounting outdoor units/indoor units using suitable size MS angles/flats cut and welded to shape fixing the same on floor or wall/parapet as required including painting with 2 coats of enamel paint over a coat of zinc chromite primer
od117983/2019_2020 : Supply and fixing of 25mm PVC pipe and along with all required accessories in surface/recess including cutting the wall and making good the damages etc as required.
90.6.6.2 : Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm
PIONEER COOLTECH
Maxsel Agencies
Bidder Name
PIONEER COOLTECH
Seven Seas Infotech Systems
Maxsel Agencies
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_451627.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .