Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹19.8 LAccepted-AOC | ₹19.8 L | 1st | Accepted-AOC Qualified |
| 2 | Not Admitted-Finance H NO 13 14 NEAR HANUMAN MANDIR NEW NANDWANI NAGAR SONEPAT 131001 | SONIPAT | HARYANA | 131001 | - | - | Not Admitted-Finance Price Bid not complied |
Tender Value
Refer Docs
EMD Value
₹36,600
Closing Date
5 May 2021, 5:00 pmClosed
Executive Engineer
EE PD-II Office PWD B and R Railway road Sonipat
Special repair for the work of infrastructure strengthening at various Sub Health Centres i.e Bhigan Rajpur Datauli and Chirasmi etc. in Ganaur constituency for the year 2020-21 upgradation into AB-HWCs Re-invite
2021_HRY_169669_1
pwd-eepd2-sonepat
Open Tender
Civil Works
Works
90 days
Sonipat
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
₹36,600
Yes
21 Nov 2022
22 Apr 2021
6 May 2021
22 Apr 2021
5 May 2021
22 Apr 2021
Amount
Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing (b) In cement (HSR 8.5 b)
Removing door and windows (wood and steel) with chowkats by making Recesses in walls when the wall is not to be dismantled:- (HSR 8.18 a) a) door
b) Window
Scraping (a) White wash and colour wash (HSR 8.32 a)
Scraping of Cement plaster. (HSR 8.32 c)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. (a)extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 (HSR 10.86 + 10.95 a)
Providing and alying 80mm thick ISI Marked interlocking paver blocks (Conforming to ISI 156582006) IRC SP 63-2004 of all shapes and colours of design mix cement M-40 over a bed of 30mm thick fine sand complete in all respect. (HSR 10.159)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinthlevel. (HSR 11.7)
Terracing consisting of tiles 22.86 cm X 11.43 Cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13)
Top khurra 0.6 m X 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13.50)
Pdg. & Fixing 100 mm RWP as per (HSR 13.89 a)
Providing & fixing vitrified tiles of size 600 x 600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. (HSR 14.89) Note:- Tiles shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT & JOHNSONS
Providing & fixing vitrified tiles of size 600 x 600mm of approved make in skirting/dado laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. . (HSR 14.90) Note:- Tiles shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT & JOHNSONS
Providing & fixing ceramic tiles/anti skid tiles of size 400mm x400mm or above size of approved make in floors, laid in any pattern as specification aover base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. (HSR 14.91) Note. Tiles shall be of premium quality (first quality) of repated manufacturer like NITCO, KAJARIA, SOMANI, ORIENT & JOHNSONS.
Providing & fixing Ist quality ceramic glazed wall tiles confirming to I.S 15622 (thickness to be specified by the manufacture) of approved make in all colors, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting risers of steps and dados over 12mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete.(HSR 14.92 b) b) Size of ceramic Glazed tiles 300x450mm
12 mm thick cement plaster 1:4 (HSR 15.5 ) (inside)
15 mm thick cement plaster 1:6 on the rough side of single of half brick wall (HSR 15.12)
Cement pointing 1:3 deep variety on brick and Tile work (HSR 15.61)
Painting one coat with synthetic enamel Paint in all shades on old wood-work, or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint. (HSR 16.7)
Applying priming coat with metal primer on New steel or iron work including preparation of surface. (HSR 16.9)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces. (HSR 16.25)
Distempering with washable oil bound distemper (of approved manufacture) two coats on old distempered work. (HSR 16.60)
Finishing walls with exterior decorative cement based paints such as snowcem, Robbiacem etc. on old work, one coat to give an even shade. (HSR 16.62)
Providing and applying two cates white cement based puty over plastered surface and grinding the durface smooth eiht sand paper to get an even and smooth finish including cost and carriage of all material, labour charge, scaffolding, sundries etc. complete (J.K/ Birla make) (HSR 16.81)
Supplying and fixing glass panes with moulding of commercial hard wood such as hillock champ, chikrassy and chaplash etc. (Non coniferous timber other than teak, conforming to I.S. specification No. 1003, kiln seasoned)- 3 mm thick (glazing area above 9 sq dm but upto 55 sq dm of each pane) (HSR 17.36 b)
Factory-manufactured wire gauze door and windows shutters of commercial hard wood such as hollock, champ, chikrassy and chaplash, etc, (non coniferous timber other teak, conforming to I.S. specification no. 1003, kiln seasoned) with 100 mm wide vertical styles, 150 mm wide locak rail 200 mm wide bottom rail and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc., complete fixed in position (excluding the cost of any fitting other than specified above, but including labour for fixing the same in position)- (styles and rails of windows shutter shall be 75 mm wide) for single lead shutter (HSR item No. 17.92 ii ) 35mm thick
Factory manufacture solid flush door and Shutters, with block board core as per I.S. No. 1659-1969 bonded with water poof type phenol formal dehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in positon includeing iron hinges, screws, chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)- 35 mm thick (HSR 17.93 a iii + 17.72a)
Providing and fixing aluminium works for doors, windows, ventilators and partitions with extruded built up standard tublar sections/ appropriate Z sections and other sections of approved make conforming to IS 733 and IS: 1285 fixed with rawlpulgs ans screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. aluminium sections shall be smooth, rust free straight mitred and jointed mechanically whrerever required including cleat angle, aluminium snap beading for glazing/ panelling C.P brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. (Glazing and panelling to be paid for separately) (HSR 17.95) Note:- Add Rs. 15/- per kg. extra if powder coating of 50 micron is done instead of anodizing in above item No. 17.95 & 17.96
Providing & fixing GI pipes complete with GI fitting & clamps, i.c cutting and making good the walls ect. (DSR 18.10)
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/ depths/ storeys/ basements etc. (HSR 18.22) Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameter as actually used in work, excluding overlaps, wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement
Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the specified sections, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, or approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:3:6 for lugs complete:- (HSR 18.34 a) a) door and window frame of size 89 mm X 50 mm with 40 mm wide single rebate
c) door and window frame size 127 mm X 50 mm with 40 mm wide double rebate
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (to the approval of the Engineer-in-charge) INDIAN TYPE WATER CLOSET SUITE CONSISTING OF:- (HSR 30.1 a i) Size 580 mm White
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (as approved by the Engineer-in-charge) EUROPEAN TYPE WATER CLOSET SUITE, SYPHONIC TYPE, Consisting of- ingle trap symphonic W.C. Suite (HSR 30.5 a i) White
PROVIDING AND FIXING IN POSITION INDIAN MAKE (ORDINARY) LAVATORY SUITES Consisting of Lavatory in VITREOUS CHINAWARE size as given Below (to the approval of the Engineer-in-charge) including china plug for tap hole where necessary; white Size 450mm x 300mm with one no. tap (HSR 30.41 i)
ii) Size 480mm x 400mm with one no. tap
Providing and fixing in position 15 mm i/d C.P brass bib Cocks of best quality (as required by Engineer-in-charge) (HSR 30.75 ) a) long/body
b) Bib cock
Providing and fixing HDPE water storage tanks of sintex, Diplast, O.K make with covers/lids marked with IS: 12701 on roof top of buildings including cost of hoisting and palcing in poosition, making connections with inlet and outlet pipes, providing overflow & scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction of Engineer-in-Charge (expect civil work) 1000 ltr. Capacity (HSR 30.119 e)
Providing & fixing standard logo circular tile HWC activities size 3ft dia complete in all respect (NS)
Providing & fixing 6x3 ft. standard circular logo Ayushman Bharat HWC complete in all respect (NS)
Providing & Fixing of design with 4"x9" border tiles printed as per norms/design of HWC i/c fixing with adhesive of good quality completed in all respect (N.S.)
Providing & fixing of PVC display board (3'x4') of 3 to 5 mm thick duly displaying the various activities of HWC as approved by health deptt.
Providing & fixing CP Jali Complete as per PWD specification (N.S)
Earth work in embankment and sub grade in embankment portion with soil from borrow pit with all lead and lift transporting to site, spreading, grading to required slope and compacted to meet requirement.
Providing and laying 300 mm granular sub base consisting of filter layer confirming to Table 400.1 Grading - III of MoRT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, complete as per clause No. 401 of MoRT&H specifications. (N.S) Note:- i) In case of any difference in the unit & nomenclature of any of the HSR items depicted in this DNIT and that given in HSR, the unit and nomencalature given in HSR shall be applicable. ii) In case of any difference in the unit of any Non-schedule items depicted in this DNIT and conventional unit of that N.S. items as per practice in this department, the conventional unit as per practice shall be applicable.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .