Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹13.8 L+₹34,313 (2.55%)Rejected-Finance 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹21.1 L+₹7.7 L (57.0%)Rejected-Finance 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
REPAIR/MAINT OF COOLING APPLIANCES AND CONNECTED ITEMS AT AF STN AMBALA UNDER GE (AF) AMBALA
2025_MES_695935_1
GE AF/AMB-T-43/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹50,000
Yes
2 Apr 2025
31 Jan 2025
3 Mar 2025
31 Jan 2025
1 Mar 2025
14 Feb 2025
Amount
Attending complaint for malfunctioning, not working, not cooling of inverter / non inverter type Split/ Window/ Cassette/ Tower AC of capacity 1.5/2/3 TR, deep fridger/fridge/water cooler /stabilizer upto 5 KVA of any make & model, deserrt cooler (both pvc and steel body) installed at AFS Ambala area, complete inspection of Cooling appliances rectification of defects, if any all as specified and as directed Note :- (i) Complaint will be resolved within shortest possible time not later than 24 hours of complaint by Engr in Charge/JE concerned to contractor otherwise penalty of Rs 500/- per complaint will be recovered from the contracor. (ii) spare parts & servicing will be measured and paid seperately under respective item of the schedule. (iii) Complaints slips will be collected from concerned complaint cell/ JE and will be deposited back after rectification of complaint duly singed by the user.
M & L Comprehensive maintainance and servicing of split type air conditioner /interver type split air conditioner of capacity 1.5 / 2.0 Ton, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning complete at site all as specified and directed. Note :- (i) Defective parts will be measured and paid separately . (ii) Job includes servicing , rectification of defects as one job (iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only.
M& L for Comprehensive maintainance and servicing of window type air conditoner cap 1.5/2.0 Ton, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning comple all as specified and directed. Note :- (i) Defective parts will be measured and paid separately . (ii) Job includes servicing , rectification of defects as one job. (iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only.
M& L for Comprehensive maintainance and servicing of Cassette type/ Tower type/split type Air conditioner cap 2/3 Ton, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning complete at site all as specified and directed. Note :- (i) Defective parts will be measured and paid separately . (ii) Job includes servicing , rectification of defects as one job. (iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only.
M& L for Comprehensive maintainance and servicing of split type Air conditioner cap 3 x 5.5 TR, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning complete at site all as specified and directed. Note :- (i) Defective parts will be measured and paid separately . (ii) Job includes servicing , rectification of defects as one job. (iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only.
M & L for detection of refrigerent leakage from split type AC repair of cooling coil / condensing coil for minor leakage if any flushing of system and gas charging in the system up to required and sealing / closing of charging value of slpit type AC / window AC capacity 1.5 TR complete at site all as specified and directed. Note:- (i) Leak detection with Nitrogen (ii) Evacation is carried out by using a vaccum pump and a recovery bottle , one the system evacuates.
All as per BOQ srl item No. 6.00 here-in-above but split type AC / window AC capacity 2 TR, Complete all as specified and directed.
All as per BOQ srl item No. 6.00 here-in-above but Cassette type/ Tower type AC cap 2/3 TR, complete all as specified and directed.
All as per BOQ srl item No. 6.00 here-in-above but split type Air conditioner 3x5.5 TR, complete all as specified and directed.
S & F in repair replacement new sealed Rotary compressor of capacity 19000 BTU/Hour ( Nearest capacity ) , single phase 230 v , 50 Hz split type conditioner / window type air conditioner complete all as specified and directed. Note - Gas charging will be measured and paid separetly .
S & F in repair replacement hermatically sealed Rotary compressor of capacity 25000 BTU/Hour ( for 2 Ton AC) single phase 230 V , 50 Hz split type air conditioner all as specified and directed. Note - Gas charging will be measured and paid separetly .
M & L for rewinding of condensor fan motor of split type AC of capacity 1.5 / 2.0 TR with same gauge of copper insulated winding wire including insulating material complete all as specified and directed.
M & L for taking down unserviceable burnt out condensor cum blower double shaft fan motor of window AC of capacity 1.5 / 2.0 TR , repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe work for making bearing seat complete & installing the same & commissioning complete all as specified and directed.
M & L for taking down unserviceable burnt Indoor blower fan motor of split AC of capacity 1.5 / 2.0 TR , repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe work for making bearing seat complete & installing the same & commissioning all as specified and directed.
Supply, installing of condenser coils of split AC capacity 1.5 TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately
Supply, installing of condenser coils of split AC capacity 2/3 TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately
Supply, installing of condenser coils of Window AC capacity 1.5 /2.0 TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately.
Supply only spare part for inverter/ non inverter type split AC / window AC complete for any make / Model of capaity 1.5 / 2 / 3 TR complete all as specified and directed
Run capacitor 45/36 MFD, complete all as specified and as directed.
Single phase, 220V connector for AC of existing make and model, complete all as specified and as directed.
PCB of existing make and model ( for split/window ACs non inverter type), complete all as specified and as directed.
PCB of existing make and model ( for inverter type ACs), complete all as specified and as directed.
Cordless remote of existing make and model, complete all as specified and as directed.
Condensor motor with Blade complete all as specified and as directed.
Condenser fan blades for window type AC units of capacity 1.5T/2T, complete all as specified and as directed.
Condenser fan blades for spilt type AC units of capacity 1.5T/2T, complete all as specified and as directed.
Indoor swing motor of capacity 1.5T/2T, complete all as specified and as directed.
wiring kit for window / split type AC units 1.5/2TR, complete all as specified and as directed.
front Grill (front panel) for window type AC units 1.5/2T, complete all as specified and as directed.
Indoor Blower wheel, complete all as specified and as directed.
Suction and discharge valve set for type split AC 1.5/2T, complete all as specified and as directed.
Refrigerant Gas R-22, complete all as specified and as directed.
Refrigerant Gas R-134A, complete all as specified and as directed.
Refrigerant Gas R-32, complete all as specified and as directed.
Refrigerant Gas R-410, complete all as specified and as directed.
Supply, installing and testing outdoor unit comprising of copper Condensor coil , motor with blade ,compressor rotary type of 1.5 Ton Split type Air conditioner in any location / position including disconnecting electrical mains, removing the wires etc. and commissioning including disposing of old unserviceable outdoor unit deposited to MES AC section yard complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately
Supply, installing and testing Indoor unit of 1.5 Ton Split type Air conditioner in any location / position including disconnecting electrical mains, removing the wires etc. and commissioning including disposing of old unserviceable outdoor unit deposited to MES AC section yard complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4 sqmm drawn through and including non - metallic rigid PVC conduits of suitable size with all necessary fittings and provision of one run of 4 sqmm PVC insulated unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed. Note: Two runs of 4 sqmm cable, one run of 4 sqmm earth conductor cable and one run of PVC conduits shall be measured and paid together as one unit length.
S&F metal clad switch socket outlet with single pole and neutral enclosure with two pin and earth plug socket with 01No. single pole MCB 20Amps 10kA complete all as specified and as directed
S&F MCB SP, 240volts, 25 to 40Amps, 10kA including taking old unservicable MCBs of any type/capacity and disposing off complete all as specified and as directed
Taking down of split type aIr conditioner from existing location and installation after repair of in same / other location including gas charging , testing , commisioning and comprising of following. Replacement of refrigerant tubing with insulating sleeve upto 6RM with brass flair nut. Drain pipe upto 6RM Air conditioner bracket-1 set interconnecting cable from indoor unit to outdoor unit
Taking down of Window type aIr conditioner from existing location and installation after repair in same / other location including gas charging , testing , commisioning and comprising of following. Note Job includes cutting of window at suitable size and making good, if required etc. (ii) The quoted rates are inclusive of driling, clamping and connected items required for fixing and provision of cable upto required length and other connected items which required for installation and smooth functioning is deemed to be included in quoted rates.
M & L for repair of voltage stabilizer upto 5 KVA, 230V, 50 Hz, Single phase, including complete inspection of stabilizer, repair/repalcement of defective part whereever required and refixing the same in original position for smooth functioning all as specified and as directed. Note :- Spare parts shall be deemed to be included in quoted rates.
M & L for Comprehensive maintainance and servicing of desert cooler (steel body / Plastic body of any capacity) of fan motor, water pump cleaning of PVC pipe testing including replacement of wood wool pad (set of three) etc for smooth functioning complete all as specified & directed. Note: spare parts will be measured and paid seperately under respective item of the schedule.
M & L for rewinding of desert cooler motor of same gauge of copper insulated winding including material complete all as specifed and directed
M&L for fixing in replacement of plywood 6mm thick commerciel grade in window of desert cooler, including painting of ply after coat of primer complete all as specified and directed.
Supply only following spare parts for desert cooler (steel body) complete all as specified and directed
Capacitor 4.0 to 10 mfd
Fan motor with blade and clamp 106 watt or nearest cap single phase
Fan motor with blade and clamp 490 watt or nearest cap single phase
Tullu pump /Water pump
cooling pad of existing size
Knob switch
Front Grill of deset cooler (steel body)
M&L for preparation of surfaces of desert Cooler by scrapping old paint with sand paper, cleaning inner & outer surfaces of body and spray painting the inner surfaces and grills with two coats of black anticorrosive paint and outer surfaces with two coats of alluminium paint, over one coat of zinc chrome primer complete all as specified and as directed.
M&L for Comprehensive maintainance and servicing of refrigerator / deep freezer of capacity 165 to 310 litres including labour for detecting the leakage of gas ,repairing leakage and recharging refrigerant, cleaning of cooling coil, condenser, compressors, with vacuum cleaner and cleaning solution, checking servicibility of electrical / electronic circuits relays, wiring kit, thermostat switches, knobs, etc. and keeping the units in satisfactory working conditions complete all as specified and as directed Note: Spares / parts / componenets/ refrigerant gas will be measured and paid separately under relevant items hereinafter and labour charges for replacement shall be deemed to be included in this unit rate quoted
Supply only following spare parts for refrigerator / deep freezer of any capacity, make and model complete all as specified and directed
Thermostat switch with knob
Starting relay 1/8HP to 1/6HP open type with OLP
Copper filter, single capillary, pencil type
Vegetable tray / defrost tray / ice tray /bottle shelve/ water tray /chiller tray of PVC for 165 to 310litres capacity freezers / refrigerators of original make and type, complete all as specified and directed
Freezer door PVC for 165/180/280/300/310litres capacity refrigerators / freezers of existing make, type, desgn and size, complete all as specified and directed
Door switch for refrigerator 165 to 310litres
Interior light fittings with bulb for refrigerators
Door handles of approved design and type for refrigerators
Compartment glass of existing thinkness with PVC / plastic beading all round, of approved design and type, complete all as specified and directed
S&F in repair company made new sealed compressor units for refrigerators including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas , including disposing off old unserviceable compressor unit complete all as specified and as directed for the following types and capacities:
All as per BOQ srl item No. 34.00 here-in-above as above but capacity 165 to 180litres, complete all as specified and directed.
All as per BOQ srl item No. 34.00 here-in-above but capcity 210/280/300/310litres, complete all as specified and directed
S&F in repairs evaporator / freezer made out of aluminium pressed type of capacity 165 to 310litres capacity with freezer frame and door including connecting up complete all as specified and as directed
M&L for Comprehensive maintainance and servicing of water cooler cooling cap 40 litre/storage cap 80 litre cleaning of cooling/candensing coil, oiling of condenser fan motor, cleaning of drain pipe testing for smooth functioning complete all as specified and directed.
All as per BOQ srl item No. 36.00 here-in-above but capacity 150 Ltr, complete all as specified and directed.
Detection of refrigerent leakage from water cooler cooling cap 40liter, repair of cooling coil/condensing coil for minor leakage if any flushing of system and gas charging in the system up to required qty, and sealing / brazing/soldering complete all as specified & directed.
All as per BOQ srl item No. 38.00 here-in-above but capacity 150 Ltr, complete all as specified and directed.
S & F in repair replecement new sealed compressor for water cooling cap 40litre (or nearest cap) single phase 230 volt, 50 HZ water cooler complee all as specified and directed. Note : gas charging will be measured & paid separate)
M&L for rewinding of condensor fan motor of 1/32 HP with same gauge of copper insualated winding wire including insulating material complete all as specified and direted.
S&F only spare part for water cooler all as specified and directed
Run capacitor 25/36 MFD
Condensor fan blade
Condensor fan motor
Thermostate
CP self closing push cock 15mm dia
M&L for repair of drain tray by brazing/ nickle polishing including replacement of drain pipe of water cooler complete all as specified and directed.
M&L for replacement of legs of same size of water cooler cap 40/80 ltr & 80/150Ltr complete all as specified and directed.
M & L for replacement of steel sheet (SS 304) of same gauge of body of water cooler including welding/ brazing etc , being into shape complete all as specified and directed.
M & L for two coat of spary painting complete outside of water cooler of cap 40/80 or 60/120ltr with harmartone paint over a coat of red oxide including scarping the old painted surface , denting and minor patch works complete all as specified and directed.
u and v engineers and consultants (BID ID -3240195)
Bairagi Builders (BID ID -3244880)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .