Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC MU COMPLEX GROUND FLOOR NEAR PVS HOSPITAL KOZHIKODE 673002 | KOZHIKODE | KOZHIKODE | KERALA | 673002 | L1 | Accepted-AOC RETENDER SINGLE BID |
| Sl No | Description | Qty | Unit | ADARSH KV L1 |
|---|---|---|---|---|
| 1.00Motor installation work at Palliyarakunnu DWSS-Narikkuni GP | ||||
| 1.00 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) | 3 | sqm | 270 ₹810 Lowest |
| 1.00 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board | 2 | kg | 165 ₹330 Lowest |
| 1.00 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) | 10 | metre | 58 ₹580 Lowest |
| 1.00 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | 20 | metre | 78 ₹1,560 Lowest |
| 1.00 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) | 6 | each | 24 ₹144 Lowest |
| 1.01 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) | 8 | each | 25 ₹200 Lowest |
| 1.01 | 90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm | 20 | metre | 165 ₹3,300 Lowest |
| 1.01 | 2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N | 1 | each | 4,780 ₹4,780 Lowest |
| 1.01 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 3,200 ₹3,200 Lowest |
Tender Value
₹3.4 L
EMD Value
₹8,564
Closing Date
29 Sept 2025, 6:55 pmClosed
AE-LSGD
O/O ASSISTANT ENGINEER LID AND EW NARIKKUNI GP NARIKKUNI KOZHIKODE 673585
DWSS Narikkuni GPRenovation of panel board and motor installation work at Palliyarakunnu drinking water supply scheme under Narikkuni GPGeneral Electrical Work NARIKKUNI GP
2025_LSGD_800405_15
4/AE/LIDEW/2025-26/NRKI
Open Tender
Electrical Works
Item Rate
180 days
narikkuni
Please refer Tender documents.
13 documents required · 13 mandatory
₹755
Yes
₹8,564
Yes
13 Nov 2025
22 Sept 2025
3 Oct 2025
22 Sept 2025
29 Sept 2025
22 Sept 2025
Amount
Motor installation work at Palliyarakunnu DWSS-Narikkuni GP
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD503562/2024-2025:Supply and installation of dust and vermin proof , 3 phase syntax meter board (GSMB 6535) and to fix KSEB meters , fuse units, CT etc as required including fixing it on the wall , making good the damages colour washing etc as required.
OD503563/2024-2025:Supply and laying 10 mm or nearest size stainless steel rope
OD503564/2024-2025:Supply and laying 12 mm or nearest size nylon rope
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
OD503639/2024-2025:Lifting the damaged existing open well submersible motor pump from well, disconnecting the supply wire, dismantling the delivery pipe and accessories which are not in use and handing over the same to the concerned departmental authorities with proper written acknowledgement.
OD503640/2024-2025:Supply and fixing single phasing cum dry run preventer
OD503641/2024-2025:Supply and fixing Digital multifunction meter to read V,A,F,PF -3 phase accuracy class 1 LED
OD503642/2024-2025:Supplying and fixing 63 A HRC fuse with HRC fuse link with connections in existing meter board.
OD503643/2024-2025:Supplying and fixing 63 A,2 way neutral links mounted on DMC/SMC base with connections in existing meter board.
OD503644/2024-2025:Providing and fixing 2 x 25mm x 3mm G.I strip test joint for earthing system
OD503645/2024-2025:Providing and fixing 25mm x 3mmGI strip earth lead from the test joint to the earth plate
OD503646/2024-2025:Supply and providing 25x3mm brass nut and bolt etc. as required
OD503647/2024-2025:Supply and providing 25x6mm brass nut and bolt etc. as required
OD503648/2024-2025:Dismantling old PVC conduit with wire which are not in use and handing over the same to Departmental authorities with proper written acknowledgement
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
OD523246/2024-2025:Supply and fixing Backelite batten straight /angle holder including connection etc are required
OD523247/2024-2025:Supply and fixing 9 watt LED bulb in the existing batten holder as required
OD527301/2024-2025:Supply, laying and joining of 75 mm 80 sedulous ASTM pipe with required leak proofing materials.
OD527302/2024-2025:Supply and providing 80 mm ASTM flange set
OD527303/2024-2025:Supply and providing 80 mm NRV (GM) zoloto
OD527304/2024-2025:Supply and providing 80 mm full way wheel valve (GM) zoloto
OD527305/2024-2025:Supply, installation, testing and commissioning of 15 HP vertical open well submersible motor pump set at rated voltage 3 phase 415 V 50 Hz AC supply at 338m maximum head 15DG2M 16 stage DECCAN make delivery pipe 75 mm having discharge at 225 lpm at 184 m head using leak proofing materials as required and suspended on 2 run 10 mm stainless steel rope including fixing 80 sedulous ASTM delivery pipe with necessary supports on both sides of the motor including giving connection as per direction at site.
OD527390/2024-2025:Supplying and fixing 50 mm dia medium class GI pipe for supporting the delivery pipe on the top of the well
90.14.24.20:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.
90.14.28.18:S & F Motor starters of the following ratingsFully automatic star delta pump starter for three phase 20HP Submersible motor
90.6.6.5:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.10 sq mm
1.14.10:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Bidder Name
ADARSH KV
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1328258.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .