Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC KOONAMPALAYIL THULAPPALLI PO PATHANAMTHITTA 686510 | PATHANAMTHITTA | PATHANAMTHITTA | KERALA | 686510 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.5 L+₹20,630.15 (2.85%)Rejected-AOC CHERUPURAM CHERUVATTOOR PO | KOTTAYAM | KERALA | 686102 | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.8 L+₹54,310 (7.49%)Rejected-AOC MATTAMANA H THURUTHY PO PETTAMALA | KOTTAYAM | KERALA | 686001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹7.9 L+₹62,151.59 (8.57%)Rejected-AOC ASAMANNOOR | DHEMAJI | ASSAM | 787026 | L4 | Rejected-AOC L4 | |
| 5 | L5₹8.2 L+₹94,580 (13.0%)Rejected-AOC 1207 SUB TREASURY KUNNATHUNAD | KANNUR | KERALA | 670001 | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | C.A.AZEES L2 | jibin joseph L1 | SUGATHAN C V L4 | K P PAULOSE L5 | basil paul L6 | KURIAKOSE JOSE L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00ACP Completion | |||||||||
| 1.00 | OD480346/2025-2026:Engaging man coolies for miscellaneous work | 2 | each | 952.31 ₹1,904.62 | 800 ₹1,600 Lowest | 1,005.34 ₹2,010.68 | 1,050 ₹2,100 | 1,080 ₹2,160 | 800 ₹1,600 Lowest |
| 1.00 | OD480077/2025-2026:Designing, fabricating, testing and installing Curtain wall with Aluminum composite panel cladding with open grooves for linear as well as curvy linear portion PVDF / Lu-mi fion based fluoroscope resin coating of approved color and shade on face 500 based s of the building, for all heights and all levels etc. including: Providing, fabricating and supplying and fixing paels of aluminum composite panel cladding including aluminum base frame work in pan shape in metallic color of approved shades made out of 3mm thick aluminum composite panel material. The aluminum composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lu-mi fion based fluoro polymer resin coating of approved color and shade on face 1 and polymer (Service) coating on face 2 as specified using stainless steel screws, nuts, boltwashers, cleats, weather silicone sealant, backer rods, etc.. with aluminum composite panel cladding till the handing over of the building for occupation. The contractor shall provide curtain wall with aluminum composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description as specified , as per the approved shop drawings and as directed by the Engineer in charge, However for the purpose of payment only the actual area on the external face of the curtain wall with Aluminum composite panel cladding (including width of groove) shall be measured in sqm. up to two decimal places. OD 86/21-22 - Modified data 25.7 | 64.2 | sqm | 2,866.92 ₹1,84,056.26 Lowest | 3,500 ₹2,24,700 | 3,026.56 ₹1,94,305.15 | 3,100 ₹1,99,020 | 3,250 ₹2,08,650 | 2,950 ₹1,89,390 |
| 1.00 | OD480338/2025-2026:Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor
fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. Providing and filling, two-part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and glass is INCLUSIVE. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm up to two
decimal places. (Modified 25.2) | 140 | sqm | 3,659.13 ₹5,12,278.2 | 3,200 ₹4,48,000 Lowest | 3,862.88 ₹5,40,803.2 | 4,050 ₹5,67,000 | 4,150 ₹5,81,000 | 3,855 ₹5,39,700 |
| 1.00 | 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | 3 | cum | 6,405.54 ₹19,216.62 Lowest | 7,800 ₹23,400 | 6,762.21 ₹20,286.63 | 7,200 ₹21,600 | 7,270 ₹21,810 | 7,000 ₹21,000 |
| 1.00 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 32 | sqm | 325.38 ₹10,412.16 | 300 ₹9,600 Lowest | 343.5 ₹10,992 | 350 ₹11,200 | 369 ₹11,808 | 300 ₹9,600 Lowest |
| 1.01 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | 32 | sqm | 71.14 ₹2,276.48 | 60 ₹1,920 Lowest | 75.1 ₹2,403.2 | 80 ₹2,560 | 80 ₹2,560 | 70 ₹2,240 |
| 1.01 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 32 | sqm | 152.13 ₹4,868.16 | 150 ₹4,800 Lowest | 160.6 ₹5,139.2 | 160 ₹5,120 | 170 ₹5,440 | 150 ₹4,800 Lowest |
| 1.01 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 73.5 | sqm | 145.07 ₹10,662.65 Lowest | 150 ₹11,025 | 153.15 ₹11,256.53 | 150 ₹11,025 | 160 ₹11,760 | 150 ₹11,025 |
Tender Value
₹8.5 L
EMD Value
₹21,184
Closing Date
3 Mar 2026, 2:00 pmClosed
Assistant Engineer
Office of the Assistant Engineer, LIDEW Section, Asamannoor Grama Panchayath.
RENOVATION
2026_LSGD_839450_1
59/AE/LIDEW/ASNR/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
Asamannoor
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,870
₹21,184
19 May 2026
23 Feb 2026
4 Mar 2026
23 Feb 2026
3 Mar 2026
23 Feb 2026
23 Feb 2026 - 3 Mar 2026
ACP Completion
OD480346/2025-2026:Engaging man coolies for miscellaneous work
OD480077/2025-2026:Designing, fabricating, testing and installing Curtain wall with Aluminum composite panel cladding with open grooves for linear as well as curvy linear portion PVDF / Lu-mi fion based fluoroscope resin coating of approved color and shade on face 500 based s of the building, for all heights and all levels etc. including: Providing, fabricating and supplying and fixing paels of aluminum composite panel cladding including aluminum base frame work in pan shape in metallic color of approved shades made out of 3mm thick aluminum composite panel material. The aluminum composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lu-mi fion based fluoro polymer resin coating of approved color and shade on face 1 and polymer (Service) coating on face 2 as specified using stainless steel screws, nuts, boltwashers, cleats, weather silicone sealant, backer rods, etc.. with aluminum composite panel cladding till the handing over of the building for occupation. The contractor shall provide curtain wall with aluminum composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description as specified , as per the approved shop drawings and as directed by the Engineer in charge, However for the purpose of payment only the actual area on the external face of the curtain wall with Aluminum composite panel cladding (including width of groove) shall be measured in sqm. up to two decimal places. OD 86/21-22 - Modified data 25.7
OD480338/2025-2026:Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. Providing and filling, two-part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and glass is INCLUSIVE. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm up to two decimal places. (Modified 25.2)
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1414519.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
SBD303.pdf
Tender Documents • 1.98 MB
BOQ_1414519.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .