| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.6 LAccepted-Finance 1 DEEP NAGAR AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹7.6 L | 1 | Accepted-Finance L1 |
| 2 | 2₹8.4 L+₹87,650 (11.6%)Accepted-Finance | ₹8.4 L+₹87,650 (11.6%) | 2 | Accepted-Finance L2 |
| 3 | 3₹8.1 L+₹50,715 (6.71%)Accepted-Finance 1786 SECTOR 14 1786 SECTOR 14 HISAR SECTOR 14 HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹8.1 L+₹50,715 (6.71%) | 3 | Accepted-Finance L3 |
| 4 | 4₹9.0 L+₹1.5 L (19.8%)Accepted-Finance 121004 | ₹9.0 L+₹1.5 L (19.8%) | 4 | Accepted-Finance L4 |
| Sl No | Description | Qty | Unit | ACCURATE POWER SOLUTIONS L1 | ANANYA TRANSINFRA PRIVATE LIMITED L3 | RAJESH SINGH DALAL CONTRACTOR L4 | HRC INFRA PVT LTD L2 |
|---|---|---|---|---|---|---|---|
| 1.00Renewal and Replacement of conventional disc insulator with polymer, Number plates, Danger Plates & providing and fixing anti bird next wedge on 220KV S/C Ganguwal-Jagadhri-Kurukshetra line under O&M Division, BBMB, Jagadhri. | |||||||
| 1.01 | Dismantlement of old conventional disc insulators strings and supply, installation & commissioning of new 90KN polymer long rod disc string insulators (GTP as per Annexure-A) on A-Type suspension tower, including all necessary nuts, bolts, & other accessories and (The job is to be completed as per satisfaction of site engineer in-charge) | 51 | Nos | 6,750 ₹3,44,250 Lowest | 7,100 ₹3,62,100 | 8,000 ₹4,08,000 | 7,075 ₹3,60,825 |
| 1.02 | Providing & Fixing of Tower number plate
Specification:- ACP Sheet , Size-200X200mm with retroflex taping and nut bolts and other accessories what-so-ever required at site for fixing it to the tower and dismantlement of old number plates. (The job is to be completed as per satisfaction of site engineer in-charge) | 149 | Nos | 1,200 ₹1,78,800 Lowest | 1,500 ₹2,23,500 | 1,500 ₹2,23,500 | 1,300 ₹1,93,700 |
| 1.03 | Providing & Fixing of Danger plate
Specification:- ACP Sheet Size-250X200mm with retroflex tapping and nut bolts and other accessories what-so-ever required at site for fixing it to the tower and dismantlement of old Danger plates. (The job is to be completed as per satisfaction of site engineer in-charge). | 50 | Nos | 1,200 ₹60,000 Lowest | 1,450 ₹72,500 | 1,600 ₹80,000 | 1,400 ₹70,000 |
| 1.04 | Providing and fixing of Anti Bird Nest Wedge on towers (Design as per annexure-B) including Painting two or more coats including priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work complete in all respect (The job is to be completed as per satisfaction of site engineer in-charge). | 84 | Nos | 2,050 ₹1,72,200 Lowest | 2,200 ₹1,84,800 | 2,300 ₹1,93,200 | 2,160 ₹1,81,440 |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
16 Feb 2026, 3:00 pmClosed
SR XEN BBMB Jagadhri
SR XEN BBMB Jagadhri
Renewal and replacement of conventional disc insulators with polymer damaged number plate danger plate and providing and fixing Anti Bird nest wedge on 220KV Ganguwal Jagadhri Kurukshetra line
2026_BBMB_264674_1
ENIT 09/2025-26 Dated 29.01.2026
Open Tender
Civil Works
Works
60 days
BBMB Jagadhri
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹9,000
23 Feb 2026
30 Jan 2026
18 Feb 2026
30 Jan 2026
16 Feb 2026
30 Jan 2026
30 Jan 2026 - 16 Feb 2026
Renewal and Replacement of conventional disc insulator with polymer, Number plates, Danger Plates & providing and fixing anti bird next wedge on 220KV S/C Ganguwal-Jagadhri-Kurukshetra line under O&M Division, BBMB, Jagadhri.
Dismantlement of old conventional disc insulators strings and supply, installation & commissioning of new 90KN polymer long rod disc string insulators (GTP as per Annexure-A) on A-Type suspension tower, including all necessary nuts, bolts, & other accessories and (The job is to be completed as per satisfaction of site engineer in-charge)
Providing & Fixing of Tower number plate Specification:- ACP Sheet , Size-200X200mm with retroflex taping and nut bolts and other accessories what-so-ever required at site for fixing it to the tower and dismantlement of old number plates. (The job is to be completed as per satisfaction of site engineer in-charge)
Providing & Fixing of Danger plate Specification:- ACP Sheet Size-250X200mm with retroflex tapping and nut bolts and other accessories what-so-ever required at site for fixing it to the tower and dismantlement of old Danger plates. (The job is to be completed as per satisfaction of site engineer in-charge).
Providing and fixing of Anti Bird Nest Wedge on towers (Design as per annexure-B) including Painting two or more coats including priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work complete in all respect (The job is to be completed as per satisfaction of site engineer in-charge).
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tendernotice_2.pdf
PDF • 0.85 MB
BOQ_307160.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .