Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC V P O KARSOG TEHSIL KARSOG DISTT MANDI HP | KARSOG | MANDI | HIMACHAL PRADESH | L1 | Accepted-AOC AOC | |
| 2 | L2₹35.4 L+₹3.6 L (11.2%)Rejected-Finance | L2 | Rejected-Finance Second lowest bidder | |
| 3 | L3₹36.1 L+₹4.2 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Third lowest bidder | |
| 4 | L4₹38.3 L+₹6.4 L (20.2%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest bidder | |
| 5 | Rejected-Technical LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | - | Rejected-Technical The successfully completed similar type of work done minimum amount not less than 40 percent of estimated cost in last five years has not submitted as per condition of tender. |
Tender Value
₹30.3 L
EMD Value
₹53,000
Closing Date
24 Feb 2020, 5:00 pmClosed
Executive Engineer
HPSIDC Ltd. Shimla
Providing Electrical Installation in Govt. ITI Building at Dalash Teh. Anni Distt. Kullu (HP)
2020_SIDC_34548_1
Job No. 11
Open Tender
Electrical Works
Item Rate
180 days
Dalash (Kullu)
Please refer Tender documents.
10 documents required · 10 mandatory
₹3,500
EE HPSIDC Ltd. Shimla
₹53,000
2 Aug 2021
3 Feb 2020
25 Feb 2020
3 Feb 2020
24 Feb 2020
3 Feb 2020
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. piano type switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. (i) 2x1.5 Sq. mm.
2x2.5 Sq. mm.
2x4.0 Sq. mm.
2x6.0 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C.
Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required. 2 Pair
Supplying and drawing LAN cable CAT 5E, solid copper conductor protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- (i) 25 mm. dia
(ii) 50 mm. dia
Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required. (i) S.P. 5/ 6 Amps one way switch, piano type.
(ii) 5 pin 5/ 6 Amps socket outlet, porcelain base/ piano type.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. (i) S.P. 5/ 6 Amps one way Modular switch.
(ii) 5 pin, 5/ 6 Amps Modular socket outlet.
(iii) Telephone socket outlet, Modular.
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:- 2 modules (78mmx78mmx50mm)
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying and fixing bakelite batten/angle holder including connections etc. as required.
(ii) 450 mm deep (nominal)
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 400 Amp. 415 volts capacity 4 No. each of cross-sectional area (38.10mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required:-
Providing and fixing TP&N switch disconnector fuse unit cubical type, 415/500 volts with 3 No. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the body etc. as required. 63 Amp. Category-A
Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required. 160 Amps.
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required. 100 Amp. -10 KA
200 Amp. -16 KA
315/400 Amp. -50 KA
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Double pole. Cat-A.
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required . 63 Amps. Cat-A.
Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-16 way
Supplying and fixing G.I. tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision to mount 8 module incomer, 2 module sub-incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-2+8 way (8+6+24),horizontal type
Double door-2+12 way (8+6+36),horizontal type
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for pipe earth electrode complete as required.
Providing and fixing 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing as required.
Earthing with G.I. earth plate 600 mmx600 mmx 6 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Supplying and laying 8 SWG Copper wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long G.I. tube, having single prong at top, with 85 mm dia 6 mm thick copper base plate including holes etc. complete as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:- Armoured cable 16 sq. mm (four core)
Armoured cable 95 sq. mm (3.5 core)
Armoured cable 120 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- Armoured cable 16 sq. mm (four core)
Armoured cable 95 sq. mm (3.5 core)
Armoured cable 120 sq. mm (3.5 core)
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- 25 Liter capacity water heater (Cat-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Model to be got approved from engineer in charge. Ceiling Fan 1200 mm sweep, Category-A
Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Exhaust Fan, Heavy duty, 300 mm sweep
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Fixed type wall bracket 150 dia, single lamp.(Category-A)
Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Bulk head fitting, CFL type (Category-A)
supplying and fixing metel box of 200*250*100mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch,3 Nos. 5/6 Amp Switch and 3 Nos. 5 pin 5/6 Amp Socket modular type switch & sockets with inner & outer plate complete connections, painting etc. as required.
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Providing & fixing LED Batten integrated LED channel of Bajaj make having Bajaj/ Havells / Philips make as below: Batten/LED integrated channel fitting 10W
Batten/LED integrated channel fitting 20W
Providing & fixing surface/ recess mounted 12/ 15W LED fitting of Syska/Havells/Philips/ Bajaj make as required complete in all respect.(i) 12W
Supplying & fixing SKYLUKS LED surface mounting fitting 1'*1' LED luminaire of Bajaj/Havells/Philips/Syska 30WH WH
Providing & fixing UV System Water Purifier Aquaguard 7 litre capacity complete in all respect as approved & directed by engineer in charge.
Providing & Fixing LED Lamp of following capacity as approved & directed by engineer in charge of Syska/Havells/Bajaj 7 - 9 Watt
Providing & fixing Skyluks efficient LED recessed 4*1 of Bajaj /Syska equivalent to Bajaj Code No. BZRSLL 36W GJI WH /NW complete in all respect fitting in ceiling as approved & directed by engineer in charge.
Providing & fixing LED fitting/ luminaire 2'*2' 36 W LED of Bajaj/ Havells /Crompton/Syska or its equivalent make equal to BZSQL 36W LED WH
Providing & installation of HIGH MAST 12.5M High Desing & installation at site of work including cariage and erection testing, commissioning, incidental actions LED light & other accessories as detaild below for street lighting in Industrial area having 12.5 Meter Lowering & Raising 12 sided Polygonal Structure High Mast lighting system having Top diameter minimum 150 mm & Bottom minimum 360 mm considering Wind velocity 180Km/Hour as per IS 875 part 3, 1987. Mast shaft shall be in Two sections, minimum sheet thickness of Bottom Section 3mm & Top Section 3mm single hot dip galvanized internally & Externally as per IS 2629 and ISO 1461. It shall also include accessories for high mast, steel wire rope 6mm, SS 316 Grade / 7/19 construction & self lubricating internal power tool double drum winch duly pre greased , Electric Motor, lantern carriage, Galvanized rigid head frame & trailing Cable shall be 5c 4 sqmm copper Round PVC nsulated & PVC sheathed G.I single Spike Lightening Arrestor etc. The shaft material construction shall be as per IS 2062, BS EN 10025 Yield Point 355N/m. The Mast shall be of minimum two wire ropes suspension system without any intermediate joints. Suitable to use with 8/12 numbers LED Floodlight. The job includes the cost of Foundation Nuts & Bolts 360X150 3/3 Plate Thickness minimum 445 PCD Foundation Bolts M24/750X4 and double earthing of high mast with G.I stripe. The job also includes the cost of Control panel of High Mast including motor control circuit as required. The drawing and design of high mast shall has to be got approved from the Engineer-in-charge and the testing of high mast shall be done by the Engineer-in-charge before its installation. The firm will have to supply all the test certificates of the high mast to the department and no extra payment shall be made by the department for testing and certificates.
Design & casting of foundation with M20 cement Concrete & steel reinforcement suitable for installation of 12.5 Mtr high mast. The complete foundation design & calculations duly certified by the structural engineer shall be submitted by the firm before laying the foundations for approval of the Deptt. The foundation structure design should be of the manufacturer of high mast keeping in view the wind pressure and soil capacity of the area where the high mast is to be installed. The actual load bearing capacity shall be tested by the firm at its own cost. However the rate & design for the foundation for load bearing capacity should be 10 TON per sqm.
Supply, carriage & erection of Single Dome LED Avaition Obstruction Light Single dome integral LED aviation light comprising of aluminium housing with polycarbonate enclosure to be installed on existing High Mast Pole of height 12.5 / 16 Mtr. approx. including cost of suitable mounting arrangement and making necessary connections, testing and commissioning etc. to the entire satisfaction of EIC. The LED aviation light should be of IP-65 and should be as per its relevant IS specifications.
Supply, carriage and erection of 180W Turbo LED Floodlight of Bajaj /Crompton/Philips Luminaire made up of die cast aluminium housing with cover IP66 having efficacy better than 110 lumens per watt. The Fixture supplied with Electronic high efficiecy driver having Power factor >0.9, THD <10% , Surge Protection min 6KV. The Company logo must be embossed on the body of fixtures. The Luminaire shall comply all relevant national and international standards with Type tested from NABL accredited Lab to ascertain minimum technical specifications containing in LM 79 & LM 80 reports. The firm shall has to submit the LM 79 and LM 80 report. The sample of fitting shall be got tested from some NABL I UL accredited lab and the expenditure for that shall be borne by the firm.
Providing & fixing stainless steel body water cooler having capacity 40/80L i.e. storage 80 L and cooling 40L per hour of USHA make as per approval of the eingineer in charge complete in all respect
P/F shock treatment chart as approved & directed by Engineer-in-Charge.
P/F synthetic rubber mat shock proof of 2mtr x 1mtr confirmed to IS as approved & directed by Engineeer-in-Charge.
Rajesh Kumar Jaswal
Bhim Sain Negi
ARUN KUMAR SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .