Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹9.9 L
EMD Value
₹19,822
Closing Date
15 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Upgradation of Seed Testing Laboratory for NABL Accreditation at Lalmandi Srinagar B.W.O Providing Electrification facility and allied works to seed Testing Laboratory at Lal Mandi Srinagar
2025_PWDJK_297180_1
NIT No.209/2025-26 Dt/02/12/2025
Open Tender
Electrical Works
Percentage
LAL MANDI SRINAGAR
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹19,822
3 Dec 2025
3 Dec 2025
16 Dec 2025
3 Dec 2025
15 Dec 2025
3 Dec 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit, with modular switch ( L&T Entice/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha/ eq. make to be approved by EIC.), modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( L&T Entice/Legrand Mylinc /SSK NV/schneider Leiva /ABB Tvisha/ eq. make to be approved by EIC)
Wiring for lighting circuits/ 6- 10 amp power plugwith 2X2.5 sq. mm FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( L&T Entice/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha / eq. make to be approved by EIC.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, "C" curve including connections, painting etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Polycab Green/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ), single core cable in surface/ recessed medium class PVC conduit as required.
(b ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire
( b )2 X 10 sq. mm + 1 X 6 sq. mm earth wire
(f) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
( b )4 X 10 sq. mm + 2 X 6 sq. mm earth wire
(f) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete
Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 110 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ LT /Wipro/eq. make. sample to be approved before installation..
Supply & Fixing of 36W , 2x2 LED reccesses/ surface type Luminaire suitable for operating Voltage range of 150V-270V with inbuilt surge protection of 2KV and Color temprature 5700K ANSI BIN . Minimum system lumens 4320 and system efficacy >120 Lm/watt (Supported by in house NABL approved report of LM79 provided by OEM and duly signed by company manager not below rank of RM) . Luminaire should be suitable for armstrong /grid ceiling mounting with help of 4 Nos clips for suspension. Body made up of CRCA powder coated with Diffused Optics. Luminaire size should not be less than 595x595x60mm and power factor >=0.95, CRI>=80, THD<10%, Max system wattage should be 36 Watt, IP-20 ingress protection. NABL certification and BIS (both luminaire and driver) requried to be provided at the time of sample approval. Philips/LT/Wipro make /equivalent make to e desired by enginneer incharge( sample to be approved before installation)..
Supply installation testing and comm. Of 250mm-300mm sweep exhaust fan industrial Heavy duty / steel body of USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
Supply installation testing and comm. Of 200mm-250mm sweep exhaust fan steel body of USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan ( USHA/havell /Bajaj/Crompton/equivalent make as directed by engineer incharge,) with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. the job includes the steel rod of suitable size and length to be installed at site.
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /SSK NV/schneider Zencelo /Havell Coral / eq. make to be approved by EIC.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( legrand/ Scheinider/Hager / eq. make to be approved by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
8 way, Double door ( 24+4)
Supplying and fixing of following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. legrand / Schinider/ L&T ./equivalent make as directed by engineer incharge.
a) 6-32 Amp SP MCB
b) 40-63amp DP MCB
c) 40-63amp TPN MCB
Providing of Chemical earthing as per IS standards by way of digging 2.5 mt. deep pit ( 3ft x 3ft) then embedding 2 meter copper bound G.I Earthing electrode , 80mm dia. connecting the electrode with main control board by copper wire/ strip ( to be paid seperately) Full thread brass nut and bolt and washers. Refilling of pit with 3 bags ( 20 kg each bag) of chemical compound.complete job. the job also includes the back filling by way of soft soil to enhance the ground resistivity. complete job.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
S/L , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
c) 95 sq.mm 3.5 core
b) 35 sq.mm 3.5 core
Earth work excavation for cable trench, 2 ft deep with an average breadth of 1.5ft and refilling of trench with excavated earth after laying of cable and ramming it properly excluding cost of cable.the job also includes laying of warning tape .
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
90 mm dia (OD-90 mm & ID-76 mm nominal)
Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement)
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
Normal INCOMING:
a)200A 4P MCCB 25 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB / eq. make to be approved by EIC.
b) 4 No. of Aluminium Bus Bar of 400 Amp.
c)Digital meters and phase indicators -1 set.
d) onload Change over switch 160 Amp for generator.Front operated.
e) 4 No. of Aluminium Bus Bar of 200 Amp.
c)Digital meters and phase indicators -1 set.
Inverter Incommer
(a) 125 amp DP MCCB 16K Legrand/ Shinider/Semiens/ABB / eq. make to be approved by EIC.
(b) 200 Amp 2 strip bus bar
c)Digital meters and phase indicators -1 set.
OUTGOING:
c) 40-63amp DP MCB
c) space for 16 way MCB's
Engaging of skilled labour for Dismentling of old damaged materials like wires in scraps, fixtures switches-sockets complete as directed by the engineer at site and stacking and handing over to concerned department including carrying out some repairing works etc.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_963168.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .