| Sl No | Description | Qty | Unit | M/s PAMPOSH ELECTRICALS L1 | N S ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Quote without the cost of PVC conduit as its already laid) | |||||
| 1.10 | Group A | 5 | Point | - | - |
| 1.20 | Group B | 5 | Point | - | - |
| 1.30 | Group C | 935 | Point | - | - |
| 2.00 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(Quote without the cost of PVC conduit as its already laid) | 19,300 | Mtrs | - | - |
| 3.00 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 100 | Mtrs | - | - |
| 4.00Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Quote without the cost of PVC conduit as its already laid) | |||||
| 4.10 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 50 | Mtrs | - | - |
| 4.20 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 9,000 | Mtrs | - | - |
| 4.30 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 800 | Mtrs | - | - |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
25 Jul 2020, 2:00 pmClosed
DGM Unit Electric JKPCC Ltd Srinagar
DGM Unit Electric JKPCC Ltd Srinagar
Internal Electrification of Academic Block of Medical College at Baramulla
2020_PWDJK_100574_1
27/E/K of 2020-21 Dt. 15.07.2020
Open Tender
Electrical Works
Item Rate
90 days
Baramulla
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Yes
FC JKPCC Ltd A/c
₹3.4 L
Yes
ED JKPCC Ltd Office
20 Aug 2020
16 Jul 2020
27 Jul 2020
16 Jul 2020
25 Jul 2020
16 Jul 2020
20 Jul 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Quote without the cost of PVC conduit as its already laid)
Group A
Group B
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(Quote without the cost of PVC conduit as its already laid)
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Quote without the cost of PVC conduit as its already laid)
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
2 way 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100mm X 75mm)
4 Module (125mm X 75mm)
6 Module (200mm X 75mm)
8 Module (125mm X 125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 300 mm sweep
Supply,testing and commissioning of Ceiling fans (crompton greaves High Breez or approved equivalent) complete with double ball bearig,motorbearing,r,blades,down-rod canopies capacitor two module stepped type electronic fan regulator suitable for operation on 230V 50HZ 1-phase A.C supply complete as required
12oomm sweep
1400mm sweep
Supply,testing & commissioning of 900 RPM 300mm ( Crompton Greaves trans Air or approved equivalent ) Exhaust Fan suitable for single phase 230v 50HZ AC supply Complete with motor louvers,shutters etc complete as required
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Group B
Group C
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way Double door
12 way Double door
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar,neutral link, earth bar, din bar, detachable gland plate interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating,4pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating,2pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating,three pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 Amp, 16 KA,TPMCCB
125 Amp, 16 KA,TPMCCB
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting / sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For horizontal run)
Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Suply and installation of integral LED 4ft luminarie with CRCA housing and PC Glossy Cover.The luminarie should have a color consistency SDCM < 5,CRI> 80 and CCT of 6500K.The luminarie shall be compliant with IP 20 classification.Luminarie shall be designed to emitt at least 4000 nominal lumens at a system efficacy of attleast 115 lumens / watt with a maximum warrage of 34watts.The luminarie shall be designed so as to ensure lumen depriciation of upto 30% over 50K burning hours @ design ambient temp 45deg C. The electronic driver used shall have a power factor > 0.95 and THD < 10% and suitable for an operating voltage range of 140-270 V AC.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above parameters
Supply and Installation of LED 2x2 luminarie with CRCA housing suitable with fully diffused diffuser for general lighting in office area.The luminarie should have a color consistency SDCM < 5,CRI>80 and CCT of both 4000 K / 6500 K.The luminarie shall be compliant with IP 20 & IK02 classification.Luminarie shall be designed to emitt atleast 3600 nominal lumens and an outstanding backlit solution efficacy of atleast 120 lumen / watt and a maximum system wattage of 31 watts.The luminarie shall be designed so as to ensure lumen depriciation of upto 30% over 50K burning hours @ design ambient temp 45 deg c.The electronic driver used shall have a power factor > 0.95 and THD< 10%.The electronic driver used shall have a power factor > 0.95 and THD < 10% and suitable for an operating voltage range of 140-270 V AC.The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above parameters
Supply & Installation of Recess LED 300 x 1200 mm fitting made of CRCA and PMMA diffuser, Fixture should have minimum efficacy at system level ( Not chip level ) > = 120 lumens/watt and a minimum system output lumen of 3000 lumens and maximum system wattage of 23W. Luminarie should have a life of 50000 hrs @ L70B50 Lumen maintaince CCT upto 4000/6500K,CRI > 80, PF>0.9,THD<10%.and an operating Voltage Range of 140-270V. Internal surge Protection 2.5KV.The fixture should comply with parameters as per IS10322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above parameters
Supply & Installation of LED Indoor surface downlighter suitable for general lighting.Luminarie should have a polycarbonate cover with diffused optics.The luminarie should have CRI>80 and CCT of 3000K/4000K/6500K.The luminarie shall be compilant with IP20 classification.The fixture should have a minimum system efficacy of 110 lumens / watt and a minimum system lumen output of 2000 lumens and a maximum system wattage of 18 watts. The luminarie should be designed so as to ensure lumen deprication of upto 30% over 50K burning hours@ design ambient temp 45deg CThe electronic driver used shall have a power factor > 0.95 and THD< 10%.The electronic driver used shall have a power factor > 0.95 and THD < 10% and suitable for an operating voltage range of 140-270 V AC.The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above parameters
Supply,Installation of LED indoor recessed Downlighter suitable for general lighting.Luminarie should have Die-cast heat sink with reflector of PC and high quality diffuser.The luminarie should have CRI > 80 and CCT of 3000K/4000K / 6500K.The luminarie shall be compliant with IP20 classification.The fixture should have a minimum system efficacy of 110 lumens/watt and a minmum system lumen output of 1500 lumens and amaximum system wattage of 13.5 watts.The luminarie shall be designed so as to ensure lumen depreciation of upto 30% over 50K burning hours @ design ambient tep 45deg C The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above parameters
Supply,Installation of LED indoor recessed Downlighter suitable for general lighting.Luminarie should have poly carbonate cover with diffused optics.The luminarie should have CRI>80 and CCT of 3000K/4000k/6500K.The luminarie shall be compilant with IP20 classification.The fixture should have a minimum system efficacy of 95 lumens/watt and a minimum system lumen output of 1000 lumen and a maximum system wattage of 11 watts.The luminarie shall be designed so as to ensure a lumen deprication of upto 30% over 50K burning hours @ design ambieent temp 45deg C.The electronic driver used shall have a power factor>0.95,THD<10%.The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above paramete
Supply,Installation of LED indoor recessed Downlighter suitable for general lighting.Luminarie should have poly carbonate cover with diffused optics.The luminarie should have CRI>80 and CCT of 3000K/4000k/6500K.The luminarie shall be compilant with IP20 classification.The fixture should have a minimum system efficacy of100 lumens/watt and a minimum system lumen output of 1200 lumen and a maximum system wattage of 12 watts.The luminarie shall be designed so as to ensure a lumen deprication of upto 30% over 50K burning hours @ design ambieent temp 45deg C.The electronic driver used shall have a power factor>0.95,THD<10%.The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above paramete
Supply,Installation of integral LED 2ft luminarie with extruded aluminium housing with PC cover.The luminarie should have a color consistency SDCM<5,CRI>80 and CCT of 4000/6500K The luminarie shall be compilant with IP20 classification.The fixture should have a minimum system efficacy of100 lumens/watt and a minimum system lumen output of 1200 lumen and a maximum system wattage of 12 watts.The luminarie shall be designed so as to ensure a lumen deprication of upto 30% over 50K burning hours @ design ambieent temp 45deg C.The electronic driver used shall have a power factor>0.95,THD<10%.The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above paramete
Supply,Installation of LED Highbay luminarie with a housing of Pressure Diecasted Aluminum and cover of toughned and shatter proof quality glass to ensure protection.The Luminarie shaould have a color consistency SDCM<5,CRI>80 and CCT of 6500K.The luminarie shall be compliant with IP66 classification and impact protection of IK08 to ensure durability.Luminarie shall be designed to emitt at least 10000 nominal lumens at a system efficacy of atleast 130 lumens/watt and maximum system wattage of 80W.Lumiarie should have specific designed optic module aloows UGR<25 with both centrally fit rotationally symmetric narrow beam and wide beam options avaliable to provide flexibility in applications.Lumiarie should have eyebolt mounting arrangements.The Luminarie should be designed so as to ensure lumen depriciation of upto 30% over 50K burning hours @ design ambient tep 45deg C.The electronic driver used shall have a power factor > 0.95 and THD<10% with a minimum inbulit surge protection of 4KV.The Luminarie should have auto shutdown at 325+_ 15V and auto recovery options with loop in loop out model avaliable too.The fixture should comply with the parameters as per IS10322.The LED driver should comply to IEC61000-3-2 ed ,2009 for Harmonics,IEC61347-2-13,2006 in conjuction with IEC61347-1 ed 2.0 , 2007 for Electric safety,IEC62384 ed.1.1,2011 for performance and IEC61547 ed.2.0,CISPR-15 for EMI.Manufacturer shall have inhouse lab,approved by NABL or ministry of science of govt of India.LM79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply, erection, testing & commissioning of PDB. This will be floor mounted, free standing, indoor duty, dust & vermin proof, front operated, having front hinged lockable doors, and will be complete with the main and auxiliaries bus bars, interconnection, earth terminals, earth bus and will be powder coated finished with 70 micron. The PDB panel shall use all for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panels will be made as per detailed specifications and drawings forming part of this document. The incoming and outgoing for PDB shall be as follows:
Load Bearing Member to be made out of 2.0mm CRCA Sheet
Partition to be made out of 1.6mm CRCA Sheet
Gland Pltes to be made3.0 mm thick
(Each MCCB will be variable current setting for over current and short circuit, front extended lockable handle, pad lockable in off position, indication light for ON, shrouding on incomer side, termination shall be suitable for aluminium bus bars.)
Bus bar shall be of Aluminium and continuous throughout the width of the panel and vertical cross section of bus bar shall be equal to the total ratings of feeders fed by the vertical bus bars subjected to minimum size being used as per fault level. Bus bar shall have minimum conductivity of 58%. All MCCB's shall have indication light for ON, shrouding on incomer side, phase barriers, rotary extended handle.
L+P R PDB FOR ACADEMIC BLOCK (LOCATION : ACADEMIC BLOCK G/F) (Ics=10KA) (Ics = Icu = 100%)
One set of TPN, Al. bus bar rated 630 Amps (after considering necessary deratings of 75%) for phases and neutral for half capacity of phases.
The outgoings feeders are as under
8 nos 125 Amps TPN feeder each having on number 125Amp TP MCCB with isolable neutral and on indication. 6 Nos 63 Amp TPN feeder each having one number of 63 Amp TP MCCB with isolable neutral and on indication
1 No. Type II SPD 4 Mode Din mounted for nominal current 50kA per pole (8/20 micro-second) with HRC Fuses as per specification to meet 440V TOV withstand for 2 hrs. Voltage protection (VP) level will be less than 1.5kV.
1 set of complete wiring
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders.including bends,Tees,cross membersetc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25 / 40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
2 X 6 sq. mm (19mm)
2 X 10 sq. mm (19mm)
3 X 10 sq. mm (22mm)
3½ X 50 sq. mm (35 mm)
3.5 X 70 sq. mm (38mm)
3.5 X 185 sq. mm (57mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
Supply of multi core, stranded / solid aluminum conductor, XLPE / PVC insulated armoured, PVC outter sheathed 1100V, grade cables of the following sizes. ( Cable shall be suitable for -15ºC to + 50ºC temprature condition )
3.5c * 185sqmm Al, XLPE, arm
3.5c * 120sqmm Al, XLPE, arm
3.5c * 50sqmm Al, XLPE, arm
4c * 25sqmm Al, XLPE, arm
4c x 16 sqmm copper, PVC, arm
4c x 10 sqmm copper, PVC, arm
4c x 6 sqmm copper, PVC, arm
4c x 4 sqmm copper, PVC, arm
4c x 2.5 sqmm copper, PVC, arm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of PVC conduit along with accessories,or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
TV antenna socket outlet
Data socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
4 Module (125 mmX75 mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
4 Module
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
Supplying and laying following telephone cables.
5 pair 0.6mm arm cable
10 pair 0.6mm arm cable
20 pair 0.6mm arm cable
Supplying,fixing,testing & commissioning of following MDF box with module complete in all respect.
10 pair MDF box with module
30 pair MDF box with module
50 pair MDF box with module
N S ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_191240.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .