Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.6 L+₹62,581.10 (1.56%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹42.1 L+₹2.0 L (5.10%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L3 | Rejected-Finance L3 | |
| 4 | L4₹44.1 L+₹4.1 L (10.1%)Rejected-Finance 05 AYODHYA NAGAR NEAR RAM MANDIR BEHIND HARIYA COLLEGE GOKUL NAGAR JAMNAGAR 361004 | JAMNAGAR | JAMNAGAR | GUJARAT | 361004 | L4 | Rejected-Finance L4 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
10 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
ADDN ALTN TO BUILDING NOS P-7 P-8 SPECIAL REAPIRS TO SALVAGE YARD VARIOUS RAMP AND ASSOCIATED WORKS OF VARIOUS BUILDINGS AT AF STN SAMANA UNDER GE (AF) JAMNAGAR NO 1
2025_MES_693013_1
8328/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Samana under Jamnagar
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹84,000
Yes
22 Feb 2025
13 Jan 2025
11 Feb 2025
13 Jan 2025
10 Feb 2025
27 Jan 2025
Amount
Dismantling of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to a distance exc 1.5 km but n.exc 2 Km complete all as specified as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
M&L Rendering 10mm thick in CM 1:4 on on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing for skirting/dado etc complete all as specified as directed.
M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified as directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified as directed.
M&L for Non skid, coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified as directed.
M&L for Non skid, ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified as directed.
M&L Green Marble work 15 to 18 mm thick (table rubbed and polished) in steps, jambs, pillars, window/door cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified as directed.
Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal from site complete all as specified as directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal from site complete all as specified as directed.
Cutting chases, pinning in, making good to facings on stone concrete, block or slab wall, where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified as directed.
S&F 20mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified as directed.
S&F 32mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified as directed.
S&F 15mm size angular Stop valves, cast copper alloy, CP,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified as directed.
S&F fancy type chromium plated, long shank & cup (concealed type) 15mm bore dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified as directed.
S&F 15mm dia size Bib taps, CP,cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified as directed.
S&F in repair 15 mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified as directed.
S&F in repair Vitreous Cliina wash basin, angle back, size 400 x 400 mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets, 32 mm dia brass waste coupling and, waste waste pipe of suitable length complete all as specified and directed by Engineer-in-Charge
S&F brass chromium plated shower rose 100 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and directed by Engineer-in-Charge
S&F in repairs sinks with drainage board made of stainless steel 1mm thick, kitchen or laboratory, with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including supply & fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete as specified and directed.
S & F in repair Tubular towel rail, 20mm dia, D type, 600mm long between flanges chromium plated complete all as specified as directed.
S&F in repair Towel Ring of CP fixed with and including chromium plated brass screws and wooden/ plastic cleats etc complete all as specified and directed by Engineer-in-Charge
S&F Kitchen plate rack made of stainless steel not less than 1mm thick with fixing acessories, overall size 600mm x 900mm x 250 mm , IN REPAIR, complete all as specified and directed by Engineer-in-Charge
S & F in repairs vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor complete all as specified and directed by Engineer-in-Charge
S&F in repair 10 Litre capacity PVC symphonic action type flushing cistern,(ISI Marked) low level with inlet ball valve, float and handle & PVC flush pipe, fixed in position and connecting complete all as specified and directed by Engineer-in-Charge
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer-in-Charge
S&F in repair chromium plated soap tray any type and fixed to plugs on wall with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge
S&F in repair chromium plated grating 100mm size with or w/o waste hole complete all as specified and directed
Dismantling and disconnecting of existing cast iron or reinforced concrete drain pipes, jointed in cement mortar 75/100 mm dia bore fixed to wall,laid in trenches etc complete all as specified and directed Engineer-in-Charge
S&F PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed on walls including clamp complete all as specified and directed
S&F PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed
S & F 75 mm bore of pipe PVC (SWR) bends of any radius fixed to PVC pipes in repair complete all as specified and directed by Engineer-in-Charge
S & F 75 mm bore of pipe PVC (SWR) bends of any radius fixed to PVC pipes provided with access door in repair complete all as specified and directed by Engineer-in-Charge
S & F 75 mm bore of pipe PVC (SWR) branch piece, single (single Y) equal or unequal fixed to PVC pipes with access door in repair complete all as specified and directed by Engineer-in-Charge
M&L for 75 mm dia of PVC (SWR) floor trap plain with grating incluing jointing with solvent cement in repair complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints fixed on walls including clamp complete all as specified and directed
S&F PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed
S & F 110 mm bore of pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes in repair complete all as specified and directed by Engineer-in-Charge
S & F 110 mm bore of pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes provided with access door in reapir complete all as specified and directed by Engineer-in-Charge
S & F 110 mm bore of pipe PVC (SWR) junction single,(Single T) equal or unequal fixed to PVC pipes with access door in repair complete all as specified and directed by Engineer-in-Charge
S & F 110 mm bore of pipe PVC vent cowl fixed to PVC pipes in repair complete all as specified and directed by Engineer-in-Charge
Demolition of brick / stone / PCC block masonry / RCC Jalli fixed in cement mortar including all quoins, pillars, arches etc. all as specified and as directed.
M&L for providing precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks exc 10 cm thick, in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall or pillars all as specified and directed.
Demolition of RCC of any descrition such as Kitchen chimniy, chajja, shelves, OHT Tanks,Pilar,wall, column.beam etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition)
M&L Reinforcement cement concrete type B1 1:2:4 using 20mm aggregate as in slab supported on walls beams and columns in floor, roof, landing and in shelves, chajja, lintel /Bands and similar wks incl necessary formwork etc complete all as specified and directed by Engineer-in-Charge
S&F mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirally and binding with and including mild steel wise (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge
S&F mild steel TMT bar 6mm to 8mm dia and over cut to length bent to shape required including cranking bending spirally and binding with and including mild steel wise (annealed) not less than 0.9 mm dia or as in stirrups complete all as specified and directed by Engineer-in-Charge
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for complete all as spd and directed
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15cm thickness below or above ground level, all as specified and as directed.
M&L for plastering 10mm thick on concrete surface in CM 1:4, finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacture instruction complete all as specified and directed Note WPC will be measured & paid separately.
Supply only integral water proofing chemical @ 200ml/Bag of cement complete all as specified and directed.
Applying coating (02 coats) of Pidifin 2k (of Make Dr Fixit or equivalant) @ (not less than) 1.54 kg/ Sq.m in two coats on sunken surfaces of toilet & bathroom and similar situation all as recommended by manufacturers complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:5:10 type E-2 (using 40 mm graded stone aggregate) as in fdn filling and mass concrete etc complete all as specified and directed by Engineer-in-Charge
S&F 40mm dia Tubes, 'medium grade', galvanised, with all fitting; laid in wall for suken for complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster in cement or cement lime mortar on brick or stone or PCC block walls etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debries to a distance exc 1.5 km but n.exc 2 Km, complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15 mm thick on stone masonary/brick / concrete block surface of walls in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge
M &L 2 coats of oil bound distemper on new surfaces of walls including preparation to distempering to match with existing work complete all as specified and directed by Engineer-in-Charge
M&L for 2 coats of wall care putty over plastered/old decorated surface of wall including rubbing with sand paper to prepare the surface even and smoothcomplete all as specified and directed by Engineer-in-Charge
M & L rendering 10 mm thick in patches on fair faces of brick or concrete surfaces in CM 1:3 as on ceiling, facia roof projection etc complete all as specified and directed by Engineer-in-Charge
M &L 2 coats of oil bound distemper on new surfaces of ceiling including preparation to distempering to match with existing work complete all as specified and directed by Engineer-in-Charge
M&L for 2 coats of wall care putty over plastered/old decorated surface of ceiling ncluding rubbing with sand paper to prepare the surface even and smooth complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15 mm thick on stone masonary/brick / concrete block surface of walls in cement mortar 1:4 finished even and smooth complete all as spd and directed (Note:- Quoted rate deemed to carryout wk at height upto 8.00 m)
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) and any pattern with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces walls/fins/facia/soffit etc complete all as specified and as directed. (Note:- Quoted rate deemed to carryout wk at height upto 8.00 m)
M&L for Preparation of old distempered / decorated surfaces of walls Washing, rubbing down and stopping of distempered and painted surfaces and applying Two coat of Distemper oil emulsion complete all as specified and directed by Engineer-in-Charge
M&L for Preparation of old distempered / decorated surfaces of ceiling Washing, rubbing down and stopping of distempered and painted surfaces and applying Two coat of Distemper oil emulsion complete all as specified and directed by Engineer-in-Charge
M & L for preparing old decorated wall /soffit/chajja/fins etc.surfaces, plastered or unplastered and applying one coat of acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 : 2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company Depot tinted) with silicon additives complete all as specified and as directed by Engr-In-Charge. (Note:- Quoted rate deemed to carryout wk at height upto 8.00 m)
S& f aluminium powder coating of any color ( thickness of powder coating not less than 50 micron) frame for door,window and ventilators or similar wk with one or more rebate inc joining cleat for fixing in repair complete all as specified and directed by Engineer-in-Charge
S&F aluminium window powder coating of any color ( thickness of powder coating not less than 50 micron)and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) in repair complete all as specified and directed by Engineer-in-Charge
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge
S&F aluminium window/ventilators shutters powder coating of any color ( thickness of powder coating not less than 50 micron) fixed type w/o sash bar, aluminium section weighing min. 0.55 Kg/m including necessary joining cleats, glazing clips, rubbers packing, anodised aluminium snap beading, screws etc in repair complete all as specified.directed by Engineer - in - Charge.
S&F sheet glass 3 mm thick ordinary quality(sheet glass is ground or obscured or frosted, on one side) and glazing with oil putty / wooden beads / aluminium glazing clip in square n.exc. 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge
S&F in repair MS louvers of 80 mm wide & 4 mm thick frosted glass including aluminium louver patti for adjusting the louvers fixed in Aluminium ventilators with screws etc complete all as specified and directed by Engineer-in-Charge
M & L Second class hard wood (hollock) plain fillets of Sectional area exc 6 Sq cm but not exceeding 13 Sq. cm, square, rectangular or triangular in section, wrought, secured with head less nails or brads, complete all as specified and directed by Engineer-in-Charge
S&F Prelaminated medium density fibre board 18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
S&F 18/19 mm thick, Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work
M & L Second class hard wood (hollock) plain fillets of Sectional area not exceeding 3 Sq. cm, square, rectangular or triangular in section, wrought, secured with head less nails or brads, complete all as specified
S & F Continuous (piano) hinges, mild steel, width of flaps (when open) is 30 mm bright finish or electrogalvanised
S& F for magnetic catcher of plastic body with striking plate etc and fixed complete
S&F 75 mm in size aluminium handles cast type anodized complete all as specified and directed by Engineer-in-Charge
S&F Hasp and staple, safety type 100 mm, of aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws
Taking down chowkats or frame with shutter of any description (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site complete all as specified and directed Engineer-in-Charge
S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening complete as per manufacturer's specifications and as directed by Engineer-in-Charge
S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters of any description (W/out taking off shutters from the frames) and removal from site complete all as specified and directed Engineer-in-Charge
Taking down shutter of any description n exc 1.00 sqm each and removal from site complete all as specified and directed by Engineer-in-Charge
Taking down shutter of any description exc 1.00 sqm and n exc 2.00 sqm each and removal from site complete all as specified and directed by Engineer-in-Charge
Taking down shutter of any description exc 1.00 sqm and n exc 2.00 sqm each and Refixing of shutters in same opening after resecuring or easing & adjusting, complete all as specified and directed by Engineer-in-Charge
M &L Second class hard-wood in scantlings clean sawn timber fixed etc complete all as specified and directed Engineer-in-Charge
S&F 30 mm thick 2nd class HW Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass / gauge, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), fitted to chowkats complete all as specified and directed by Engineer-in-Charge
S&F 2nd class HW 30mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed Engineer-in-Charge
S&F 100 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified & directed.
S&F 75 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge
S&F 125 mm in size aluminium handles cast type anodized complete all as specified and directed by Engineer-in-Charge
S & F 250 mm mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directed by Engineer-in-Charge
S & F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aparture 1.18 mm and fixed with tinned tacks ro galvanised wire stapple complete all as specified and directed by Engineer-in-Charge
S&F in repair Curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new surfaces of wood or wood based materials of any description not other wise described over 10 CM width or girth new or previously un treated wooden surfaces and applying one coat of pink primer and two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
S&F in repair 100 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed by Engineer-in-Charge.
S&F in repair 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F in repair 125 mm in size aluminium handles cast type anodized complete all as specified and directed by Engineer-in-Charge
S & F in repair 250 mm mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directed by Engineer-in-Charge
S & F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aparture 1.18 mm and fixed with tinned tacks ro galvanised wire stapple complete all as specified and directed by Engineer-in-Charge
S & F in repair Continuous (piano) hinges, mild steel, width of flaps (when open) is 30 mm bright finish or electrogalvanised
M&L for Cutting holes in brick/stone walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc half brick but not exc one brick complete.
M&L for Cement concrete 1:3:6 type C-2 as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spiked framed guard bars barred iron doors ladders framed blasters walkways railings framework of water tanks and similar work conforming to Fe 290 Grade E-165
M&L for preparation of new steel surfaces over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide.
M&L for preparation of old painted wooden surfaces, exc 10 cm width or girth and applying two coat of synthetic enamel paint all as specified and as directed by Engineer-In-Charge.
M&L for providing cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in fdn filling and mass concrete etc complete.
M&L for 100 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) as in floor / hard standing/Path ,etc complete all as specified & directed.
M&L for 75 mm thick Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in plinth protection etc complete all as specified and directed.
M&L for providing cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges, coping and the like bands etc including weathering, sightly rounded or chamfered angles and thoating, as directed. NOTE : - (a) The rates include for use of form work (Straight or curved). (b) Concrete items, if so indicated, shall be reinforced. Reinforcement shall be measured separately.
M&L for Forming construction/dummy joints 30mm deep x 10mm wide filled with sealing compound Grade B etc complete all as specified and as directed by Engr-in-Charge.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge
S&F Rolled mild steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.(Fe-410- W(Gde E-250) quality B )complete all as specified and directed by Engineer-in-Charge
S&F Plates (Plain or chequered) channels,squarecut or notched (ordinary and counter sunk) forming holes, w/o any attachment conforming to FE-290( Gde-E-165 ) complete all as specified and directed Engineer-in-Charge
S & F of Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed
Excavation in post holes in hard/dense soil (or similar holes) each n.exc 0.5 cum, getting out, returning, refilling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in any type of soil removing surplus soil to a distance n exc 50 m complete all as specified and directed.
Supply & Fix 06 mm thick plain, multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end, fixed with self drilled screws and standard fittings, fixtures and accessories in repair complete all as specified and as per manufacturer's instructions.
Dismantling Stone slabs and tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar including removal of debries from the premise complete all as specified and directed by Engineer-in-Charge
M&L for Rubber moulded chequered cement concrete tile with white cement and pigment (of approved tint) of size 30 cm x 30 cm x 25 mm thick over and including 15 mm thick screed bed in cement Mortar 1:6, set, jointed and pointed in neat cement slurry complete.
Dismantling Stone slabs and tiles of any description or thickness in floors,aprons etc laid dry or laid dry and pointed including removal of debries from the premise complete all as spd and directed.
Material & Labour Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment laid over and including 20 mm thick sand screed bed complete.
Dismantling of plain or corrugated steel sheeting any gauge, thickness, from roof coverings etc complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling water tanks exc 250 ltr and n.exc 500 ltr and removing to store complete all as specified and directed by Engineer-in-Charge
S&F 300 litres capacity triple layer, any coloured rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete all as specified and as directed.
S&F 500 ltrs capacity double layer, rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position over existing PCC platform incl all fitting such as connection pieces with GI tank nipple for inlet, outlet, etc complete all as specified and directed
S&F in repair 25mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed
S&F CPVC ball valves for 32 mm outer dia pipecomplete all as specified and directed by Engineer-in-Charge
S&F 200mm, ordinary MS rat tail rod pattern springs including roller and roller plate in repair complete all as specified and directed by Engineer-in-Charge
Taking down carefully any aluminum /copper point wiring (light,fan,socket or power) complete including conduits/casing caping including removing material/debris for taking credit and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed.
Taking down carefully sub main wiring complete of any type (batten / surface conduit) complete and making good disturbed surfaces complete all as specified and directed.
Taking down carefully by unscrewing from fitting and fixtures as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings,DB,MCB etc, for credit as specified and as directed
Taking down carefully by unscrewing from fitting and fixtures as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings,DB,MCB etc, for reuse at site or carrying to the store( To be found measured only when found serviceable in all rspect for reuse) and refixing all as specified and as directed
M & L for point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including super deluxe casing caping (not less than 25 mm wide) with all its accessories like bends, tees, suitable module PVC boxes o etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire and plastic laminated PVC box with cover plate as specified and directed by Engr -in charge:
a) One light / fan / exhaust fan point controlled by one, one way switch.
b) One light point controlled by two, two way switch
c) One 3 pin socket out let 5 Amps on same board with other switches.
d) One 3 pin socket out let 5 Amps on the independent board.
e) One bell point control by one push button on r independent with cable 1.5 Sqmm size
-Ditto- all as per item No 139 about but with 4.0 sqmm multistranded copper multistranded conductor FRLS cable with 4 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board as specified and directed by Engr -in charge:
S & F switch Piano 5 Amps, flush button type, SP, one way, 230 Volts complete as specified and directed by Engr -in charge:. Make - Leader/Anchor/SSK as approved.
S & F switch Piano 5 Amps, flush button type, SP, two way, 230 Volts comnplete as specified and directed by Engr -in charge:. Make - Leader/Anchor/SSK as approved.
S & F switch bell push 5 Amps, flush button type, SP, one way, 230 Volts complete as specified and directed by Engr -in charge: Make - Leader/Anchor/SSK as approved
S & F Switch socket combination multipurpose 5 pin 5 Amps, flush type, 230 / 250 Volts complete as specified and directed by Engr -in charge:. Make -Leader/Anchor/SSK
S & F switch socket combination ,6 pin ,15 amps, flush type, multipurpose, 230 / 250 volts complete as specified and directed by Engr -in charge:. Make - Leader/Anchor/SSK as approved.
S & F bell Ding Dong type AC 230 Volts, complete all as specified and directed by Engr -in charge
M&L for Ceiling rose, 3 terminal polycarbonate body 6 Amps, 250 volts AC, including connecting complete as specified and directed by Engr -in charge:.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
M & L for sub main wiring with two single core PVC insulated and unsheathed cable 6.0 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including casing and caping complete with all accessories alongwith provn of 6.0 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire and connecting to tbe BD with proper size of lugs/thimbles etc comnplete all as specified and directed by Engr -in charge
Supply and fix sheet metal enclosure MCB DB, single pole and neutral, 8 ways double door 240 volts having 200 Amps rated bus bar with balnking plates wherever required and degree of protection I.P 43 -IK 09 with acrylic cover as including all connectionsas directed by engineer in charge
Supply and fix sheet metal enclosure MCB DB, triple pole and neutral, 4 ways double door 415 volts having 200 Amps double door rated bus bar with blanking plates wherever required and degree of protection I.P 43 -IK 09 with acrylic cover as including all connectionsas directed by engineer in charge
Supply and fix MCB single pole 240 volts 6 to 32 Amps (to be fixed as per load requirement) 220V with 'C' curve complete as including all connectionsas directed by engineer in charge
Supply and fix MCB Single pole Neutral 240 volts 40- 63 Amps (to be fixed as per load requirement)220V with 'C' curve complete as including all connectionsas directed by engineer in charge
Supply and fix MCB’s triple pole & neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Taking down Ceilling fan/exhaust fan with cover plate , sealing cable end, dismantling blades and removing fan and blad for painting of ceiling fan/Exhaust fan complete with synthetic enamel paint black/ white by spraying including filling of cavities with filler, one coat after cleaning all rust and dust etc complete and refixing the same with 0.5 sqmm , flexible ,three core wire, copper conductor cable all as directed by Engineer-In-Charge. all as specified and directed.
Supply and fix stepped type electronic fan regulator flush type, 230 V, including connecting complete.
Supply & Fix energy efficient LED tube light fitting with built in LED & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
S&F energy efficient LED tube light fitting with built in LED & integral LED drive 10 watt, channel housing & diffuser of length 600 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
S&F energy efficient LED tube light fitting with built in LED & integral LED driver 5 watt, channel housing & diffuser of length with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
S & F in plastic body exhaust fan size 250 mm sweep, single phase, 1200 RPM, ISI marked, including louvers , with connection from ceilling rose with 0.5 Sqmm flexible three core wire complete in walll/window including making hole in surface and re surfacing it as per direction of engineer in charge
S&F in repair LED building security light fitting 35 Watt, system efficiency not less than 100 lumen / Watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, pipe, bracket on building,
M & L for sub main wiring with two single core PVC insulated and unsheathed cable 2.50 sqmm with multi stranded copper conductor , FRLS type cable drawn through and includingPVC conduit complete with all accessories alongwith provn of 2.50 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire and connecting to tbe BD with proper size of lugs/thimbles etc comnplete all as specified and directed.
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Disconnecting & Taking out LT underground cable(aluminum/copper conductor of size 6 sqmm any core from trenches including cable cover,tubes if any etc complete all as specified and directed.
Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 6 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing, including taking down old cable complete.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc, n exc 10 Sqm on plan area and getting out in soft / loose soil.
Returning, filling in including spreading levelling watering and well ramming in layer n.exc 25 cm thick using excavated soil all as specified and directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point all as specified and as directed.
M & L for sand filling in trenches for cable cushioning with clean dry fine sand, including gently punning around cable complete all a specified and directed. NOTE :- Punned thickness of sand will be measured and paid.
Supplying & laying factory made unreinforced precast cable cover LV type 1 flat of size 250 x150 x 40 mm all as directed by Engr-in-Charge.
Supply and lay GI tubing light grade 40 mm bore with all necessary fittings laid in trenches, under road crossing, in floors or fixed to poles / DB for cable protection etc complete all as specified and directed.
VINUBHAI P. CHANDRA (BID ID -3230615)
M/s SK Traders (BID ID -3236243)
KEVAL ENTERPRISE (BID ID -3235844)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .