Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹51.5 L+₹5.2 L (11.3%)Rejected-Finance SHREE NIVAS LIMDA LANE JAMNAGAR GUJARAT PIN 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹51.5 L+₹5.3 L (11.4%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L3 | Rejected-Finance Not L1. | |
| 4 | L4₹52.3 L+₹6.1 L (13.2%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Not L1. | |
| 5 | L5₹52.3 L+₹6.1 L (13.2%)Rejected-Finance | L5 | Rejected-Finance Not L1. |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
5 Sept 2024, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR/MAINT OF HIGH MAST LIGHTS, SOLAR OPERATED STREET LIGHTS, PERIMETER LIGHTS, AND INTERNAL STREET LIGHTS AT AF-II AND EXTERNAL WATER SUPPLY AT AF STATION DWARKA AND KHAMBHALIYA ALONG WITH CERTAIN OTHER CONNECTED WORKS UNDER GE (AF) JAMNAGAR NO.2
2024_MES_666530_1
8513/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹1 L
Yes
23 Oct 2024
18 Jul 2024
6 Sept 2024
18 Jul 2024
5 Sept 2024
1 Aug 2024
Amount
FOR DWARKA AND KHAMBHALIYA AREA
Excavation in trenches not exceeding 1.5 m wide but not exceeding 1.5 m in depth for foundation etc or for shafts and getting out in soft/losse soil including trimming sides and bottom of trenches complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above starting point where directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each in soil complete all as specified and directed.
S&F in repairs 15 mm bore unplasticised PVC pipes of pressure rating 10 Kg f/cm2 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. Note:- Excavation / earth work will be measured and paid separately.
S&F in repairs 20 mm bore unplasticised PVC pipes of pressure rating 10 Kg f/cm2 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. Note:- Excavation / earth work will be measured and paid separately.
S&F in repairs 25 mm bore unplasticised PVC pipes of pressure rating 10 Kg f/cm2 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. Note:- Excavation / earth work will be measured and paid separately.
S&F in repairs cast iron flanged ends swing type operation with rubber seat as per IS:4038 metal foot valve 150 mm size complete all as specified and directed.
S&F in repairs cast iron flanged ends swing type operation with rubber seat as per IS:4038 metal foot valve 80/100 mm size complete all as specified and directed.
M & L for painting of old pipe line of DI or GI surfaces of any description not exceeding 10cm width or girth and applying two coats of synthetic enamel paint with showing arrow in water flowing direction in white colour complete all as specified and directed.
M & L for painting of old pipe line of DI or GI surfaces of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint with showing arrow in water flowing direction in white colour complete all as specified and directed.
Repair to submersible pumping set capacity 15/10 HP, 440V, 3 Phase discharged 510 LPM at 123 Metre head consisting of following:-Opening of submersible motor and cutting to burnt winding and cleaning to slots by cleaning and repair to damage starter etc, rewinding to submersible motor with suitable size of superior quality copper winding wire insulating materials complete all as specified and directed. (a) Replacement of thrust bearing – 01 No (b) Replacement of bush – 02 Nos (c) Re-assembling and transporting to Pump House,lowering pump and testing complete. Dismantling of submersible pump set all as directed and replacement of the following items:- (i) Replacement of neck ring – 05 Nos (ii) Replacement of brass bushes– 05 Nos (iii)Replacement of shaft bush- 02 Nos (iv) Replacement of impeller -12 Nos Note: Rates are inclusive of old u/s copper and spares
S&F in repairs flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 4 Sqmm fixed to wall / in duct, laid in floor/trench or fixed to motor etc complete all as specified and directed.
S&F in repairs flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 6 Sqmm fixed to wall / in duct, laid in floor/trench or fixed to motor complete all as specified and directed.
S&F in repairs flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 10 Sqmm fixed to wall/ in duct, laid in floor/trench or fixed to motor complete all as specified and directed.
S&F in repairs flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 16 Sqmm fixed to wall/ in duct, laid in floor/trench or fixed to motor complete all as specified and directed.
S&F in repairs flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 25 Sqmm fixed to wall/ in duct, laid in floor/trench or fixed to motor complete all as specified and directed.
Taking out the borewell pump with borewell lifting machine and disconnecting the all electrical connection and install after fixing MS pipe heavy column pipe to borewell motor with accessories to fix the borewell pump and done all the electrical connection as existing complete all as specified and directed.
Supply and fix chloroscope (range -0.1 ppm to 2.0 ppm) complete all as specified and directed.
S&F in repairs gun-metal, brass globe gate valves or ball valve of size 15 mm dia with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs gun-metal, brass globe or gate valves of size 20mm dia with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of size 25mm dia with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of size 40mm dia with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs for gun-metal, globe or gate valve of size 50mm dia, with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs for sluice valve of size 100 mm dia and class PN 1.6, with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs for sluice valve of size 150 mm dia and class PN 1.6, with iron wheel head, screwed both ends DI pipe and fixed complete all as specified and directed.
S&F in repairs for sluice valve of size 200 mm dia and class PN 1.6, with iron wheel head, screwed both ends DI fixed and complete all as specified and directed.
Supply and fix 15 mm dia tubes of medium grade with all fittings to walls and ceilings or laying in floors with all fittings complete all as specified and directed.
Supply and fix 20 mm dia tubes of medium grade with all fittings to walls and ceilings or laying in floors with all fittings complete all as specified and directed.
Supply and fix 25 mm dia tubes of medium grade with all fittings to walls and ceilings or laying in floors with all fittings complete all as specified and directed.
Supply and fix 40 mm dia tubes of medium grade with all fittings to walls and ceilings or laying in floors with all fittings complete all as specified and directed.
M&L for rectification of leakage from GI 80 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 80 mm bore medium grade connecting as per site requirement new pipe line with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete all as specified and directed.
M&L for rectification of leakage from GI 50 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 50 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete all as specified and directed.
M&L for rectification of leakage from GI 40 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 40 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete all as specified and directed.
M&L for rectification of leakage from GI 25 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 25 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete all as specified and directed.
M&L for rectification of leakage from GI 20 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 20 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete all as specified and directed.
M&L for rectification of leakage from GI 15 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 15 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete all as specified and directed.
S&F in repair fully automatic DOL starters in sheet steel enclosure AC-3 duty,415 V, suitable for upto 7.5 HP motor and relay range capacity 15-25 A, complete all as specified and directed.
S&F in repair fully automatic star delta starters in sheet steel enclosure AC-3 duty, 415 V, suitable for upto 15 HP motor and relay settings9-15 A complete all as specified and directed.
S&F in repair fully automatic star delta starters in sheet steel enclosure AC-3 duty, 415 V, suitable for upto 20 HP motor and relay range 14-23 A complete all as specified and directed.
Taking out of old existing unserviceable GI tubing 15 mm dia from the existing surface / floor / trenches / wall / saddeling complete from the existing line complete all as specified and directed. Note- Excavation for taking out will be measured and paid separately under relevant item of schedule.
Taking out of old existing unserviceable GI tubing 20 mm dia from the existing surface / floor / trenches / wall / saddeling complete from the existing line complete all as specified and directed. Note- Excavation for taking out will be measured and paid separately under relevant item of schedule.
Taking out of old existing unserviceable GI tubing 25 mm dia from the existing surface / floor / trenches / wall / saddeling complete from the existing line complete all as specified and directed. Note- Excavation for taking out will be measured and paid separately under relevant item of schedule.
Taking out of old existing unserviceable GI tubing 40 mm dia from the existing surface / floor / trenches / wall / saddeling complete from the existing line complete all as specified and directed. Note- Excavation for taking out will be measured and paid separately under relevant item of schedule.
Cleaning of semi underground sump of capacity 50000 litre at AF dwarka pumphouse, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate or Chlorine solution including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depostting complete all as specified and directed.
Cleaning of semi underground sump of capacity 100000 litre at AF dwarka pumphouse, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate or Chlorine solution including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depostting complete all as specified and directed.
Cleaning of semi underground sump of capacity 25000 litre at AF khambhalia pumphouse, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate or chlorine solution including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depostting complete all as specified and directed.
Cleaning of clear water semi underground sump of capacity 50000 gallons at AF khambhalia pumphouse, by draining out storage water completely with mud pump or throeing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate or chlorine solution including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depostting complete all as specified and directed.
Cleaning of RCC overhead reservoir of capacity 50000 gallons at 20 metre staging, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate or chlorine solution including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depostting complete all as specified and directed.
Taking out & rewinding the existing unserviceable burnt motor upto 3 HP, 3 phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete all as specified and directed. Note - Before rewinding the existing motor, contractor must show the burnt motor/winding to the Engr-in-Charge. Old unserviceable copper retrieved will be property of contractor. Rates are inclusive of Old U/s copper winding and u/s spares.
Taking out & rewinding the existing unserviceable burnt motor upto 5 HP, 3 phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete all as specified and directed. Note - Before rewinding the existing motor, contractor must show the burnt motor/winding to the Engr-in-Charge. Old unserviceable copper retrieved will be property of contractor. Rates are inclusive of Old U/s copper winding and u/s spares.
Taking out & rewinding the existing unserviceable burnt motor upto 7.5 HP, 3phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete all as specified and directed. Note - Before rewinding the existing motor, contractor must show the burnt motor/winding to the Engr-in-Charge. Old unserviceable copper retrieved will be property of contractor. Rates are inclusive of Old U/s copper winding and u/s spares.
Taking out & rewinding the existing unserviceable burnt motor upto 60 HP, 3phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete all as specified and directed. Note - Before rewinding the existing motor, contractor must show the burnt motor/winding to the Engr-in-Charge. Old unserviceable copper retrieved will be property of contractor. Rates are inclusive of Old U/s copper winding and u/s spares.
M&L for rewinding of submerssible pump motor of capacity 7.5 HP from pit/sump by disconnecting and mechanically by all electrical and pipe connections complete with replacement of old unserviceable burnt insulated copper wire and rewinding complete with same guage of submerssible insulated wire and testing complete with refitting on site complete all as specified and directed. Note-Rates are inclusive of Old U/s copper winding and u/s spares.
M&L for rewinding of submerssible pump motor of capacity 15/20 HP from pit/sump by disconnecting and mechanically by all electrical and pipe connections complete with replacement of old unserviceable burnt insulated copper wire and rewinding complete with same guage of submerssible insulated wire and testing complete with refitting on site all as per site requirement or as directed by EIC. Note-Rates are inclusive of Old U/s copper winding and u/s spares.
M & L for servicing and maintenance of RO treatment plant cap 1000 to 10000 Ltrs /day by cleaning of filter catridge, cleaning and servicing of dosing pumps, motor,control valve, FRP insdustrial RO vessel, multi port valve, pre filter and membran system including minor repair to defective/ damaged pipe line for suction and delivery lines complete all as specified and directed. Note: (i) Routine/maintenance of various parts mentioned under this item shall be carried out twice in the year. (ii) All defective parts shall be replaced under respective items which shall be measured and paid seperately.
Supply and fix in repair raw water centrifugal mobobloc pump of capacity 2000LPH at 25MWC, CI Material with 1.0HP power suitable for single phase 240 volts system, as per existing frame, complete all as specified and directed.
Supply and fix in repair anitscalant dosing pump electromagnetic type 0 to 1.5LPH capacity with pressure diascharge 2.0kg/cm2 as per existing suitable for single phase 240 volts system, as per existing model, complete all as specified and directed.
Supply and fix in repair blending line complete with blending valve and ICPW made of PVC higher grade suitable for RO water treatment plant as per existing capacity and grade complete all as specified and directed.
Supply and fix in repair Jumbo Wound Cartridge Filter For Water Filter 20inch of existing shape and dimensions made of cotton/micofiber suitable for water filter operation complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair membrane hydramem for water treatment(RO plant) suitable for pressure of 15.5 bar size : 4040/8040 made of Poly-amide Composite for Working Pressure of 10-12 Kg complete all as specified and directed.
Supply and fix in repair 1.5 KW single phase reverse osmosis control panel, automatic, digital type suitable for 230 volts system complete all as specified and directed.
Supply only antiscalant chemical 8211, liquid, packed in 25 kg HDPE container complete all as specified and directed.
Supply and fix carbon media suitable for 1000 LPH RO plant complete all as specified and directed.
Supply and fix sand media suitable for 1000 LPH RO plant or filteratin plant complete all as specified and directed.
Supply and fix filter media vessel of existing size and pressure suitable for 1000 LPH RO plant complete all as specified and directed.
M&L for earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to required items at another end e and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 3 of SSR of part-I (1991) complete all as specified and directed.
M&L for earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 25x4 mm earth strip as earth electrode welded and revetted to earth plate at one end connected to required items at another end e and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 3 of SSR of part-I (1991) complete all as specified and directed.
Complete cleaning and servicing of 125 cubic metre filte capacity plant compact type (13 feet x 7.5 feet x 5.5 feet) made ion exchange taking out all the filter media, sand gravels of all sizes, lamella plates and refix the gravels and plates after proper cleaning and top up required filter media sand as required and complete all as specified and directed. Note: Extra top up sand will be measured and paid up separately.
Deployment of man power for collecting the sample of water, from different point such as under ground sump, RO plant and sewage treatment plant for chemical testing of water from reputed Govt Laboratory for iron content in water, PH value, Hardness, turbidity, chloride, fluoride and other parameters as per IS standard.Submitting the test report to Engr-in-Charge complete all as specified and directed.
Supply only calcium hypo chlorite high strength chlorination chemical (65% - 70%) for water disinfectant in granular from in factory sealed HDPE Container. Note: (i) Contractor must submit/produce test report with hologram for the each lot/batch (ii) Each drum must be affix with Hologram (iii) Contractor must submit in writing about the ordered qty, date of packing of each drum, batch no and nos of drums and date of dispatch either on his letter head or from authorised dealer letter head. Make :- M/S Sree Rayalaseema Hi-strength Hypo Ltd. or any other make as approved by Zone/command/E-in-C branch from time to time.
Supply only potash alum crystal type or water soluble alum crystals as a flocculant for water purification complete all as specified and directed.
Supply only sodium hypo chlorite solution Grade -I low strength chlorination chemical (10% - 12%) for treated water disinfectant in factory sealed air tight HDPE Container 25 Lit /45 Lit conforming to IS 11673:11992 complete all as specified and directed. Note: Each package should contain following information (a) Name and grade of material (b) Gross and net mass (c) Date of packing (d) Lot number (e) Indication of source of manufacturer.
M&L for poly aluminium chloride as coagulant/flocculent for transforming raw water in to clean and safe water for treated waste water, inorganic soluble polymer powder in factory sealed 25 Kg HDPE bags wit two LDPE liners complete all as specified and directed. Make: Grasim Industries limlited " Vikram pac " AC/100S grade or equivalent make with ISI and NSF certification both. Note: (i) Contractor must submit/produce test report with hologram for the lot/batch supplied by Grasim Industries Ltd to Engr-in-charge (ii) Each drum must be affix with Hologram.
Supply and fix solar panel for of required size and capacity inbuilt highest quility tougned glass of 12v with excellent low light efficiency,anti refletive coating with DC wire for the connection to the motor complete all as specified and directed.
M&L for periodical servicing & maintenance of chemical dosing plant by providing specialist trades men including replacement of valve, rubber washer, check nut, connecting nuts, adapter and cleaning and servicing of solution tank and connected items to ensure that perfect serviceability of the plant and obtain required dosage to the entire satisfaction of the Engr-in-charge. Note:- (i) Minor item such as gasket, wires, lugs or any other item require for periodical servicing & maintenance shall be deemed to be included in the cost of this item. (ii) Major spare part if found unserviceable shall be measured & paid separately as supply only.
Supply and fix in repair dosing pump/injector, high/Max pressure of 4 kg/cm2 and max flow rate 6 liters/hr, single head gear motor adjustable dosing pump with accessories complete including lead tubing, connecting Nuts, injection check valve, clay weight and ferrules, suitable for altoch dosing plant complete all as specified and directed.
FOR JAMNAGAR AREA
Excavation in trenches in hard/dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth for laying cables in trenches/pole foundation and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each in soil complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above starting point where directed.
Material & Labour for Sand Cushioning to UG cable 40mm wide 15cm and 8cm thick above and below the cable respectively excluding laying of PCC cable cover for protection on the top of the sand cushioning complete all as specified and directed. Note : Punned thickness of sand will be measured & paid.
Supply & Fixing in repair GI tubing light grade 40 mm bore for cable protection fixed to poles under floor/ground complete with all fittings complete all as specified and directed.
Supply & Fixing in repair GI tubing light grade 50 mm bore for cable protection fixed to poles under floor/ground complete with all fittings complete all as specified and directed.
Taking down old unsv reinforced precast concrete cable cover any type from the trenches etc complete all as specified and directed.
Laying only PCC cable cover for LT / HT UG cable, of any description retrieved complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class LV Type 2, flat, size 300mm x 180mm x 40mm thick complete all as specified and directed.
Supply & Fixing GI pipe 15 mm dia light grade along the pole for covering cable including clamp, nuts, bolts & washers etc. complete all as specified and directed.
Taking out old/unsv LT cable any size from trenches/duct, stacking at site, checking by megger and carry out repair/replacement of defective cable complete all as specified and directed.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 16 Sqmm nominal cross sectional area 2.0 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 16 Sqmm nominal cross sectional area 4.0 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 25 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 35 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 50 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 70 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistranded aluminium conductor served with inner sheathing of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 120 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and fixing / passing through pipe from junction box to street light, 2.5sqmm 1100 volts grade heavy duty cable with PVC insulated multistranded copper conductor cable flame retardant low smoke & halogen 1100volt confirming to IS complete all as specified and directed.
M & L for shifting of solar light street pole to a distance not exceeding 50 mtr and erect in true vertical position steel tabular pole, around 15.0 metres long complete all as specified and directed. Work consisting following items under Note: (i) PCC foundation & coping, Excavation earth work . (ii)nut bolt like as existing as required. (iii) hydro crane for shifting the pole (iv) material and labour regarding that work etc.
Material & labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation of electric poles, struts, blocks with and including necessary form work, and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
Material & labour for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in foundaiton of stays, bed concrete and coping of poles with and including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
Supply & fixing bracket made out of GI light grade pipe of 40/35 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50x6mm and 04 sets of nuts, bolts and washers including painting with two coats of synthetic enamel paint over a red oxide primer including dismanting existing old and unservicable security light complete all as specified and directed.
M&L for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.
M&L for earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to required items at another end e and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 3 of SSR of part-I (1991) complete all as specified and directed.
S&F LED Street Light fitting 35 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT (K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED Street Light fitting 45 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED street light fitting 90 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED street light fitting 120 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt,PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
Periodical Maintenance / servicing of 29 Watt Solar street light by carrying out following maintenance / servicing activity for minimum two times (at interval not less than 5 months) complete all as specified and directed. (a) M&L for top up of battery distilled water and checking of specific gravity.If specific gravity beyond normal value entire qty of distilled water shall be replaced. (b ) Making proper alignment of solar panels facing towards south direction. (c) Cleaning the upper surface of solar panel with glass cleaning solution. (d) Clean the battery terminals and nut/bolts with the help of filling tool, make sure the threads are not affected and nut -bolts are properly tightened and application of petroleum jelly at the terminals of the battery.
S&F in repairs pole mounted junction box (Street light boxes) weatherproof cabinets IP -65-IK-09 class II with removable chasis and faceplates, lockable door handle, sealable cover, self extinguishing conforms to EN 60439-3, for single phase lighting system, suitable for 6 module with 1 row complete all as specified and directed.
S & F in repairs 4 pole contactor 125A 4NO , suitable for 415V AC complete all as specified and as directed. Make: ABB cat part no.1SBL41120R or equivalent make as mentioned in Appx 'B' to PS.
S & F OT manual changeover switches 250 AMP, 4 pole, suitable for 415 V AC complete all as specified and directed. Make: ABB cat part OTE04CP or equivalent makes as mentioned in Appx 'B' to PS.
S & F in repairs MCB DP 32A DX3 DP, suitable for 230V AC complete all as specified and directed. Make: Legrand Cat part No.408636 or equivalent as mentioned in Appx 'B' to PS.
Supply, fix in repair analog weekly timer Switch of supply voltage 240vAC, 50/60 Hz complete all as specified and directed. Make :- Legrand cat part no.412654 or equivalent as mentioned in Appx 'B' to PS.
Supply and fix LED decorative post of lantern 45 Watt fittings including all accessories complete fixing accessories and clamp including 4 metre height painting of pole with block paint, fixed in position complete all as specified and directed. Make:- CG Cat part No:- LPTOI-45- CDL/T or equivalent as mentioned in Appx 'B' to PS.
Supply and Fix LED Bollard light fitting 9 watt, inbuilt driver mechanism, robustly designed, IP 65/IK10 protection complete with base plate and provision of wire 2.0m copper conductor from fitting to connection point incl taking down old unsv light fitting complete all as specified and directed. Make: Philips City Cube Bollard D Cat part No: BCP400LED09 D CW PSU GR S1 or equivalent as mentioned in Appx 'B' to PS.
S&F LED Flood Light fitting 210 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S & F in repair 12V, 120Ah capacity Lithium Ferro Phosphate battery (at C/10 discharge rate) confirming to IS 16270 and IS 16046 complete with initial charging suitable for LED street light fitting complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary: 220-240V AC, 50/60Hz suitable for 9/10watt LED bollard fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary:220-240V AC, 50/60Hz suiatble for 40/45 watt street light fitting/post top fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.
M/s super construction (BID ID -3084191)
Harsh Infrastructure (BID ID -3083552)
jagdish machinery stores (BID ID -3085695)
High Tech Consruction (BID ID -3085899)
Krishna Bhoomi Enterprise (BID ID -3085114)
rajengineers (BID ID -3084609)
Sukhi Electricals (BID ID -3083979)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .