Loading…
Loading…
Tender Value
₹43.4 Cr
EMD Value
₹86.7 L
Closing Date
21 Aug 2026, 3:00 pm
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
TRD
16 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V which ever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of IRGCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer should have valid electrical contractor's license for the required voltage level or above the required voltage level from any state / central government licensing board.
The contractor should submit valid electrical supervisory license issued by any state/central Government licensing board.
13 conditions · 4 needing a document upload
All the bidders / tenderers should ensure that they are GST compliant and their quoted tax structure / rates are as per GST law.
The tenderers are required to submit scanned copy of cancelled cheque and NEFT mandate form alongwith the offer.
The bidder should submit ESIC and EPFO registration certificate alongwith the offer.
The bidder should submit PAN/ADHAR alongwith the offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tender Earnest money deposit: -All the tenderers / Contractors have to deposit full tender earnest money deposit as stipulated in the tender document through online modes only. Other option of deposition of EMD will not be accepted and will not be consider for tendering process.
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer.
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in this tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. And such verification or lack of such verification, by the railway shall not relive the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway thereunder.
If the e-tenderer/s deliberately give/s wrong information in his/their e-tender or creates/create circumstances for the acceptance of his/their e-tender, Railway reserves the right to reject such e-tender at any stage.
Railway reserves the right to either cancel the e-tender or reject any or all the e-tenders without assigning any reason thereof.
In case of any wrong information submitted by tenderer, the contract shall be terminated. Earnest Money Deposit (EMD), Performance Guarantee (PG) and Security Deposit (SD) of contract forfeited and agency banned for doing business on entire Indian Railway for 2 (Two) years.
Tender related all document read be carefully and followed.
In addition to Indian Railway General Conditions of Contract 2022, as amended upto date, special conditions as per tender document shall also apply.
Provision of separate feeder wire for Rev. line for 160 kmph work between SEB to DDU in DDU division.
TRD-OT-13-Feeder160-26-27
TRD-OT-13-Feeder160-26-27
Open
Works - General
18 Months
Chandauli, Uttar Pradesh
₹0
₹86.7 L
30 Jul 2026
30 Jul 2026
7 Aug 2026
111 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 43,35,30,999.4 | ||
| — | 1600.00 | — | — | ||
| Supply of OHE Structure Portal/ Mast /TTC/Super Mast/AT Mast. As per RDSO no. ETI/OHE/ 13(4/84) or latest | — | — | — | 16,80,00,000 | |
| — | 1700.00 | — | — | ||
| Erection of OHE Structure Portal/ Mast /TTC/Super Mast/AT Mast. As per RDSO no. ETI/OHE/ 13(4/84) or latest | — | — | — | 57,80,000 | |
| — | 1700.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.1 | — | — | — | 57,80,000 | |
| — | 3000.00 | — | — | ||
| Supply of Concrete for foundation and plinth (For concrete mix of M 10 and M 15 Grade Foundation) In hard Soil. | — | — | — | 1,60,89,000 | |
| — | 3000.00 | — | — | ||
| Erection of Concrete for foundation and plinth (For concrete mix of M 10 and M 15 Grade Foundation) In hard Soil. | — | — | — | 96,36,000 | |
| — | 11000.00 | — | — | ||
| Supply of Concrete for foundation and plinth (For concrete mix of M 10 and M 15 Grade Foundation) In Other than hard soil and rock. | — | — | — | 5,99,28,000 | |
| — | 11000.00 | — | — | ||
| Erection of Concrete for foundation and plinth (For concrete mix of M 10 and M 15 Grade Foundation) In Other than hard soil and rock. | — | — | — | 2,63,01,000 | |
| — | 320.00 | — | — | ||
| Supply & Erection of small part of steel. As per RDSO no. ETI/OHE/13(4/84) &49(9/95)or latest. | — | — | — | 3,41,33,334.4 | |
| — | 4000.00 | — | — | ||
| Supply of 9 Ton porcelain (CD-1050 mm) insulator. | — | — | — | 2,33,28,000 | |
| — | 4000.00 | — | — | ||
| Erection of 9 Ton porcelain (CD-1050 mm) insulator. | — | — | — | 8,93,320 | |
| — | 4000.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.9. | — | — | — | 8,93,320 | |
| — | 150.00 | — | — | ||
| Supply of 25 kv post/support insulator. | — | — | — | 11,66,400 | |
| — | 150.00 | — | — | ||
| Erection of 25 kv post/support insulator. | — | — | — | 51,000 | |
| — | 150.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.12 | — | — | — | 51,000 | |
| — | 400.00 | — | — | ||
| Supply of Guy rod assembly. | — | — | — | 33,09,600 | |
| — | 400.00 | — | — | ||
| Erection of Guy rod assembly | — | — | — | 7,07,600 | |
| — | 2000.00 | — | — | ||
| Supply of Number Plate (Retro-Reflective Type). | — | — | — | 20,02,000 | |
| — | 2000.00 | — | — | ||
| Erection of Number Plate (Retro-Reflective Type). | — | — | — | 3,06,000 | |
| — | 250.00 | — | — | ||
| Supply of a single earth electrode. | — | — | — | 6,12,000 | |
| — | 250.00 | — | — | ||
| Erection of a single earth electrode. | — | — | — | 4,39,000 | |
| — | 4000.00 | — | — | ||
| Supply & erection of 50X6 MS flat for earthing. | — | — | — | 6,28,360 | |
| — | 150.00 | — | — | ||
| Supply without Insulator and erection of a 25kV single pole isolator without earth contact assembly | — | — | — | 74,74,350 | |
| — | 150.00 | — | — | ||
| Erection of 25kV single pole isolator without earth contact assembly | — | — | — | 7,46,250 | |
| — | 150.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no. 22 | — | — | — | 7,46,250 | |
| — | 150.00 | — | — | ||
| Supply of Post & Operating rod insulators for Sr. no. 22 | — | — | — | 29,65,350 | |
| — | 100.00 | — | — | ||
| Supply of materials without insulator for termination of all aluminium 25 KV feeder/ return conductor (Single Spider) | — | — | — | 6,52,700 | |
| — | 100.00 | — | — | ||
| Erection of materials without insulator for termination of all aluminium 25 KV feeder/ return conductors (Single Spider) | — | — | — | 1,47,700 | |
| — | 100.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.26 | — | — | — | 1,47,700 | |
| — | 125.00 | — | — | ||
| Supply of all aluminium 25kV Feeder/ Return conductor (Single Spider) | — | — | — | 3,83,32,125 | |
| — | 125.00 | — | — | ||
| Manual Erection of all aluminium 25kV Feeder/ Return conductor (Single Spider) | — | — | — | 11,58,125 | |
| — | 125.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.29 | — | — | — | 11,58,125 | |
| — | 100.00 | — | — | ||
| Supply of Termination of AEC, including all fittings & accessories, i.e., Strain Clamp, adjuster etc. | — | — | — | 5,67,700 | |
| — | 100.00 | — | — | ||
| Erection of Termination of AEC, including all fittings & accessories i.e. Strain Clamp, adjuster etc | — | — | — | 1,24,600 | |
| — | 100.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.32 | — | — | — | 1,24,600 | |
| — | 250.00 | — | — | ||
| Supply of Aluminium Jumper. | — | — | — | 7,52,000 | |
| — | 250.00 | — | — | ||
| Erection of Aluminium jumper. | — | — | — | 1,00,500 | |
| — | 250.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.35 | — | — | — | 1,00,500 | |
| — | 125.00 | — | — | ||
| Supply of aerial earth conductor (AEC) with necessary accessories, fittings, and fasteners on OHE mast/Portals. | — | — | — | 92,96,875 | |
| — | 125.00 | — | — | ||
| Erection of aerial earth conductor (AEC) with necessary accessories, fittings, and fasteners on OHE mast/Portals. | — | — | — | 5,96,875 | |
| — | 125.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.38 | — | — | — | 5,96,875 | |
| — | 25.00 | — | — | ||
| Supply of Buried Earth Conductor (BEC) with necessary accessories, fittings, and fasteners. | — | — | — | 10,52,850 | |
| — | 25.00 | — | — | ||
| Erection of Buried Earth Conductor (BEC) with necessary accessories, fittings, and fasteners. | — | — | — | 44,500 | |
| — | 150.00 | — | — | ||
| Drilling of Hole in Mast/Rail as required, i.e. for connection of BEC/AEC etc. | — | — | — | 16,500 | |
| — | 25.00 | — | — | ||
| Digging of trench up to 300 mm depth, Laying of BEC and Back filling | — | — | — | 16,95,075 | |
| — | 80.00 | — | — | ||
| Supply of Al-Cu bi-metallic strip to avoid direct connection between aluminium feeder & copper jumper. | — | — | — | 35,040 | |
| — | 80.00 | — | — | ||
| Erection of Al-Cu bi-metallic strip to avoid direct connection between aluminium feeder & copper jumper. | — | — | — | 2,800 | |
| — | 80.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.45 | — | — | — | 2,800 | |
| — | 100.00 | — | — | ||
| Loading & Unloading of all types of Steel Structures. | — | — | — | 62,000 | |
| — | 100.00 | — | — | ||
| Transportation of materials. | — | — | — | 80,300 | |
| — | 125.00 | — | — | ||
| Dismantling of existing aerial earth conductor (AEC). | — | — | — | 11,60,750 | |
| — | 125.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.50 | — | — | — | 11,60,750 | |
| — | 125.00 | — | — | ||
| Dismantling of Feeder/Return Conductor. | — | — | — | 11,60,750 | |
| — | 125.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.52 | — | — | — | 11,60,750 | |
| — | 250.00 | — | — | ||
| Dismantling of Jumpers (All types). | — | — | — | 36,000 | |
| — | 250.00 | — | — | ||
| Extra on erection rate for work under a power block of Sr. no.54 | — | — | — | 36,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Feeder1.pdf
ATTACHMENT
feeder2.pdf
ATTACHMENT
Feeder3.pdf
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
GCCamendwithCslip.pdf
ATTACHMENT
ACS11GCCWorks.pdf
ATTACHMENT
eBg.pdf
ATTACHMENT
AnnexureVVA.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].