Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹31.2 L+₹49,479 (1.61%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹32.4 L
EMD Value
₹64,800
Closing Date
21 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
SPL REPAIR TO BLDG NO P-36 AT NAGTALAO UNDER GE BANAR
2023_MES_575886_1
8822/68/E8
Open Tender
Civil Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹64,800
Yes
14 Mar 2023
19 Jan 2023
23 Feb 2023
19 Jan 2023
21 Feb 2023
2 Feb 2023
Amount
M & L for MS props erecting for temporary supports to the structural members like beams, slabs etc. to relieve the load on the members during breaking of damaged concrete, removal guniting, excavation or any dismantling work as per the instruction of engineer in-charge. These supports shall be provided either in the form of props or trestles fabricated using structural steel as per the site requirements.
M & L for Chipping of exposed surface of reinforced cement concrete slab/columns/beams/chajjas/parapet/roof projection/balcony/staircase and removing loose concrete particles with chisel hammer without much impact on concrete surface, clean the surface by sand blasting using river sand with minimum of 6 kg pressure at the nozzle or air blow by electric pressure blower by mechanical compressor, cleaning the exposed reinforcement with wire brushes etc and disposal of debris including all scaffolding, machinery, tools etc all complete all as specified.
M & L for Cleaning & applying rust remover (CICO Clean-o rust) in two coats over rusted reinforcement surface including providing anti corrosive coating with two component epoxy based zinc rich primer/Rust passivation Inhibitor coat at the rate of 6-8 sq. mtr/ltr not less than 50 microns thickness with CICO ZINCILATE-500 or equivalent to reinforcement surface as per manufacturer’s instructions including all scaffolding , machinery, tools tackles complete all as specified. Make: CICO clean-O-rust or equivalent.
M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. Note : Additional Reinforcement will be provided, if the diameter of corroded steel bar is less than 30% of the original diameter, 12mm dia bars shall be provided as main reinforcement to the required length with proper development length and tie them to the prefixed shear connectors so that the additional rebar acts monolithically with the existing ones and core concrete.
M & L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. Note : Additional Reinforcement: In the case of the shear reinforcement also, if the diameter of the rebars are reduced, provide 8mm dia stirrups in the form of 2 "U" shaped bars. Tie them properly so that it has a tight contact with the main bars.
M & L for Shear Connectors by drilling 12mm dia holes up to a maximium depth of 75mm and fixing 8mm dia L shaped anchor rods as shear connectors at every 300mm c/c on the surfaces of the columns/beams or any other structural member as the case may be. Clean the same using air or blower and make sure that there are no fine particles present in the hole and filled the holes with one or two component styrene free vinylester resin anchor or two components, styrene & cement free epoxy- acrylate fixing and anchoring compound. At this stage push the shear connector gently in to the hole and finish the excess resin which comes out of the hole and allow the shear connectors not to be disturbed for Minimum 20 minutes. Make: CICO RESIFIX-G or equivalent in Fosroc lokfix/Hilti and Master builder (BASF) Note : Reinforcement shall be paid separately under item ser no 5.00 above.
M&L for new steel or rebars by drilling holes with 10 mm to 20mm dia and 100 to 200mm deep as per IS code of 10D formula and filling the holes after inserting of reinforcement dia 8 to 16mm for anchoring at ends/shear connector and filled the holes with one or two component styrene free vinylester resin anchor or two components, styrene & cement free epoxy- acrylate fixing and anchoring compound ( having the technical parameters mentioned in material specifications) using standard sealant applicator gun after drilling holes of required diameter at required locations, for holding / fixing / placing in position the steel mesh reinforcement at desired level/ stretching complete all as specified. (Note : Steel/reinforcement shall be paid and measured separately) . Make: CICO RESIFIX-G or equivalent.
M&L for use of waste providing leak proof steel shuttering in any position cut to length and providing runners supports as per manufacturer’s instructions, including all necessary scaffolding, machinery, tools tackles etc complete all as specified.
M&L for providing Micro concrete with CICO MICROCRETE at the rate of 25kg per 0.0125 m3 with 20% properly graded 5mm to 10mm silt free aggregate as per manufacturer instructions and mixing concrete with mechanically electrically operated mixer machine etc all as specified.Make: CICO MICROCRETE of CICO Technologies ltd or equivalent.
M&L for applying to the damaged concrete portion of slab/columns/beams/chajjas/parapet /roof projection/balcony/staircase with single component, fiber reinforced, dual shrinkage- compensated thixotropic, cementitious patch repair mortar CICO Repocem PM (having the technical parameters mentioned in material specifications ) capable of applying up to 20-25mm thick in two layer initially by hand and finishing with troweled carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface with an average specified thickness complete all as specified. Make: CICO Repocorn PM or equivalent.
M & L for applying bond coat on the prepared old surface of concrete/masonry to receive new polymer mortar/polymer modified mortar or micro concrete with two coats of CICO-Latex SBR or equivalent in Fosroc /STP as per manufacturer specifications. Laying of reinstatement polymer mortar or micro concrete shall be completed within the overlay time of bonding coat. This bond coat act as bonding agent between old and new concrete complete all as specified. MAKE: CICO LATEX SBR or equivalent.
M&L for prepration of old decorated plastered or unplastered surfaces by brooming down of steel wire brushing, scrapping down moulds mass and efforescent salt, washing, rubbing down and treating oil greasy spots and finishing walls with Premium Acrylic Smooth exterior paint using Silicone additives of required shade by applying two coats @ 1.43 ltr/10 sqm over and including a coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified.
S&F Aluminium anodised sections in existing partition or door frame or door shutter or window frame or window shutter swing or sliding including alumnium clip cleat, sashbars , glazing clips, rubber packing, aluminium anodised beading etc of approved size and thickness including drilling holes in walls, ceilings, floors with screws and rawl plugs etc including taking down and refixing after necessary repairs complete all as specified.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified.
S&F 100mm long aluminium anbodised barrel tower bolts of extruded section and fixed all as specified.
S&F Mortice lock vertcal type 4 levers 100mm size of brass body of approved make with two sets of keys complete all as specified.
S&F 5.5mm thick sheet glass ordinary quality and glazing with aluminim snap beading in squars exc 0.5 Sqm in each pane all as specified.
S&F rubber beading for aluminuim doors/windows complete all as specified.
S&F Double action floor spring hydralucilly regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all, as specified.
S&F solar control film 25 micron reflective type sticked to glass panes as per manufacturers instruction and complete all as specified.
S&F in repairs 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with screws to timber frame/aluminium frame complete all as specified.
M&L for rendering 10mm thick plaster on fair faces of concrete surface in cement mortor (1:4) finished the surface even and smooth without extra cement all as specified.
Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water all as specified
M&L 10mm thick rendering on Stone masonry in cement mortor 1:6 without using extra cement all as specified.
M&L for two coats of oil bound distemper over a coat of chalk whitening to newly plastered surfaces of walls including preparation of surfaces complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified.
M & L for Vitrified ceramic colour (Double Charged) tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36sqm , in floors etc, set and jointed in neat cement slurry and pointed in white cement or cloured to match over and including 15 mm thick screed bed in CM 1:6 to receive floor tiles complete all as specified.
M & L for Vitrified ceramic colour (Double Charged) tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36sqm , in vertical surface such as skirtings , dados etc, set and jointed in neat cement slurry and pointed in white cement or cloured to match over and including 10 mm thick rendering in CM 1:4 to receive vertical tiles complete all as specified.
Taking down carefully aluminium/copper point wiring of any type/size for Light, fan, socket or power complete including making good the disturbed surfaces finishing of wall / floor etc, complete all as specified.
Taking down unserviceableOld/damaged Sub main wiring any size complete all as specified.
Taking down unserviceable rusted/damaged sheet metal enclosure DBs of any size/type/ways from wall complete all as specified.
M&L Point wiring of One light point controlled by one switch with 1.5 Sq. mm PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including PVC casing caping (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screw etc complete all as specified.
All as per item Ser No 33.00 but One fan/ exhaust fan point controlled by one switch.
All as per item Ser No 33.00 but One bell/buzzar point controlled by one bell push independent
All as per item Ser No 33.00 but One switch socket out let point 5 Amps on independent board
All as per item Ser No 33.00 but One switch socket out let point 5 Amps on same board
Material and labour for surface point wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of same size/specification for contineous earthing connected to common earth dolly complete drawing in and including suitable size of PVC casing & caping with all fittings and accessories fixed properly on wall or ceiling including PVC terminal boxes for mounting switches socket for 3 pin 15 amp independent board all as specified.
Supply and fixing switch piano flush type 5 Amp single pole, one way complete all as specified.
Supply and fixing for ceiling rose surface bakelite 65 x 50 mm three terminal complete all as specified.
Supply and fixing socket outlet 5 pin 5 Amps, flush type complete all as specified.
Supply and fixing Socket outlet 2 in 1 5 pin 5 and 15 amp flush type complete all as specified.
Supply and fixing Socket outlet 2 in 1, 5 pin 5 amp flush type complete all as specified.
Supply and fixing bell/buzzer Ding dong AC 230 Volts single pole complete all as specified.
Supply and fixing stepped type electronic fan regulator, resistance type complete all as specified.
Material and labour for sub main wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of 4 Sqmm for contineous earthing wire connected to common earth dolly complete drawing in and including suitable size of PVC Casing Caping with all fittings and accessories fixed with properly on wall or ceiling as per specified.
Material and labour for sub main wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 6 Sqmm and one run of 6 Sqmm for contineous earthing wire connected to common earth dolly complete drawing in and including suitable size of PVC Casing Caping with all fittings and accessories fixed with properly on wall or ceiling as per specified.
Material and labour for sub main wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 10 Sqmm and one run of 10 Sqmm for contineous earthing wire connected to common earth dolly complete drawing in and including suitable size of PVC Casing caping with all fittings and accessories fixed with properly on wall or ceiling as per specified.
Supply and fixing in replacement powder coated sheet metal enclosures MCB DB, double door, SPN 8 way, 240 Volt fitted with bus bar, DIN channel, neutral link and incoming contact complete all as specified .
S&F in replacement powder coated sheet metal enclosures MCCB VTPN DB, double door, tripple pole and neutral, 4 way 415 volts fitted with insulated vertical phase 200 amps bus bar/neutral bar with 125 Amps TPN incommer and 3 outing for 63amps shround earth bar cement spill proctector interconnecting wire set cable tiesblanking plates and circuit indentificationlables etc all as per IS-8623-1 IK-09 complete all as specified.
Supply and fixing in replacement MCB SPN 32 Amps 'c'curve type 240 volts complete all as specified.
Supply and fixing in replacement MCCB TPN 125 Amps 415 volts. 18kA Adjustableoverload setting l &fixed magnetic setting complete all as specified.
Supply and fixing in replacement MCB SP 6 to 32 Amps 'c'curve type 230 Volt complete all as specified.
Supply and Fixing in replacement mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x20 Watt,(4 feet) fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit complete all as specified.
Supply and fixing in replacement Recces mounting (2'X2') 36w LED light fitting, integrated polycarbonate LED channel with white acrylic efficiency PMMA diffuser soft glare free light cover complete suitable with driver holder & lamp holder for fixed properly on ceiling and connecting complete to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit complete all as specified.
S&F in replacement building security light LED 45 watt fitting with pressure die cast housing, epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual LED lences suitable for including fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit complete all as specified.
Supply and fixing in replacement bracket for street light fittings of any size made out of GI pipe medium grade 32 mm dia 1.25 mtr length bend to required size and shape including provision of clamps and fittings in position and two coat of aluminum paint over a coat of red oxide primer all as specified.
S&F in replacement Metal Clad Plug and socket with box 20 Amp with single pole MCB complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm complete all as specified.
M&L in replacement for Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louversy on wall surface with the provisioning of suitable sizes of rag bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 2.5 Sqmm 3 core and overall PVC sheathed which shall be passed through PVC flexible conduit of length not exceeding 0.50 mtr all as reqd and as directed by Engr-in-Charge.
M&L for Earthing in repairs complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below ground level connected to galvanized iron earth stip of size 25 x 4mm by means of bolt, nut, check nut and washer of galvanized iron or steel protected by galvanized iron pipe of 40 mm bore light grade, incl. funnel, 20 mm dia bore galvanized iron pipe medium grade for watering, wire mesh, charcoal or coke and common salt in alternative layers all around the earth electrode compacted thickness 15 cm incl. excavation and earth work hard soil, PCC 1:3:6 type C2, CI pit cover, incl. disposal of surplus soil to a distance n. exc. 50 m, complete testing on completion, all complete as shown in electrical plate No 3, SSR Part-I all as specified.
Supply and fix in repairs Earth contunity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe of 25X4 mm galvanised iron strip complete all as specified.
Kusum Traders
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .