Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.3 LAdmitted-Finance | -14.98% | ₹5.3 L | L1 | Admitted-Finance |
| 2 | L2₹5.3 LAdmitted-Finance | -14.50% | ₹5.3 L | L2 | Admitted-Finance |
Tender Value
₹6.3 L
EMD Value
₹12,500
Closing Date
6 Mar 2026, 1:00 pmClosed
Registrar JNVU Jodhpur
As per tender document
Laying Cable Work in Various Faculties , Jai NarainVyas University, Jodhpur.
2026_JNU_541440_8
NIT NO 05 OF 2025-26
Open Tender
Civil Works
90 days
JODHPUR
As per tender document
2 documents required · 2 mandatory
₹1,000
Registrar JNVU Jodhpur/MD RISL
₹12,500
Yes
18 Mar 2026
28 Feb 2026
6 Mar 2026
28 Feb 2026
6 Mar 2026
28 Feb 2026
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 120.0 Sq. mm 3.5 core
150.0 Sq. mm .5 core
300.0 Sq. mm 3.5 core
Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.11 MB
Tendernotice_2.pdf
PDF • 0.30 MB
Tendernotice_3.pdf
PDF • 0.91 MB
BOQ_968591.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid