Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 CrAdmitted-Finance | ₹13.3 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | BIJU AUGUSTINE L1 |
|---|---|---|---|---|
| 1.00Supply and Laying 450mm DI raw water pumping main to Thompilkadavu well cum pump house to Ummunicavu WTP | ||||
| 1.00 | 100.98.122:Supply of DI K9 Pipe Conforming to IS 8329/2000, 450mm Dia. | 6,908 | metre | 11,544 ₹8.0 Cr |
| 1.00 | 100.98.466:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 450mm. | 1 | no | 1,11,285.64 ₹1.1 L |
| 1.00 | OD225174/2023-2024:Supplying 250mm DI K9 Flanged pipe . | 50 | metre | 4,704.15 ₹2.4 L |
| 1.00 | 100.98.482:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm. | 7 | no | 9,255.99 ₹64,791.93 |
| 1.00 | 100.98.451:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm. | 7 | no | 17,848.02 ₹1.2 L |
| 1.01 | 100.98.462:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm. | 2 | no | 31,028.72 ₹62,057.44 |
| 1.01 | OD225175/2023-2024:Supply of CI Non Return Valve, Conforming to IS 5312 Part I and 2- 1984,or latest edition PN as per design, Size 450mm. | 1 | each | 91,248.6 ₹91,248.60 |
| 1.01 | 100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. | 2,960 | metre | 33.9 ₹1.0 L |
| 1.01 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 22.5 | cum | 1,869.92 ₹42,073.20 |
Tender Value
₹10.3 Cr
EMD Value
₹5 L
Closing Date
5 Aug 2024, 2:00 pmClosed
The Superintending Engineer, KWA, PH Circle, Thiru
Office of the Superintending Engineer, KWA, PH Circle, Thiruvalla, Pathanamthitta
JJM-5th SLSSC-CWSS to Chenneerkkara and Omalloor Pts-Supplying and laying 450mm DI K9 Raw water pumping main from Well cum pump house to WTP,supply and erection of 630 KVA transformer, VT pump sets and road restoration.
2024_KWA_664594_1
377/2023-24/KWA/PHC/TVLA (RT-1)
Open Tender
Civil Works - Water Works
365 days
Chenneerkkara
As per NIT conditions, submitted Tender Documents and Q1 to Q8
7 documents required · 7 mandatory
₹19,518
₹5 L
Office of the Superintending Engineer, KWA, PH Cir
15 Aug 2024
27 Feb 2024
6 Aug 2024
27 Feb 2024
5 Aug 2024
27 Feb 2024
27 Feb 2024 - 5 Aug 2024
29 Feb 2024
Amount
Supply and Laying 450mm DI raw water pumping main to Thompilkadavu well cum pump house to Ummunicavu WTP
100.98.122:Supply of DI K9 Pipe Conforming to IS 8329/2000, 450mm Dia.
100.98.466:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 450mm.
OD225174/2023-2024:Supplying 250mm DI K9 Flanged pipe .
100.98.482:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm.
100.98.451:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm.
100.98.462:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm.
OD225175/2023-2024:Supply of CI Non Return Valve, Conforming to IS 5312 Part I and 2- 1984,or latest edition PN as per design, Size 450mm.
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.14.8:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 450mm diameter Ductile Iron Class K-9 Pipes.
18.70.8:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:450 mm dia pipes
100.35.8:Testing 450mm DI/CI pipeline with potable water to the required test pressure. 450 mm dia Observed Data derived from item no.1027 of PHED DATA
100.37.12.1:In situ fabrication of M.S. pipes of size 450mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.12.2:Fabricating M.S. flanges of diameter 450mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.3:Cutting 450mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.4:Welding 450mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.12.5:Grinding cut and weld edges of 450mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
OD225176/2023-2024:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) by using serviceable demolished stones ( excluding cost of rubble)
OD225177/2023-2024:Labour for cutting DI pipe with steel saw ,450mm Dia DI pipe
100.31.2.10:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 450mm diameter, Class II.
100.31.2.6:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 250mm diameter, Class II.
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
4.3.3:Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts
OD225178/2023-2024:Designing, providing, fixing and commissioning a Surge arrester along with design sheet 450mm size in suitable position after conducting surge analysis for proposed DI K9 pumping main including design fabrication, and supply of necessary D.I. Specials with necessary earthwork excavation, anchor blocks, construction of valve chamber and necessary road restoration works etc. as per the direction of departmental officers.
18.30.8:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
OD225179/2023-2024:Supplying and fixing ( Including specials) Electro- magnetic flow meter 450mm confirming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit . The flow water meter should have the housing ( flow sensor) to be made of SS 304/ Carbon steel with anti corrosive protection and inside liner to be made up of Hard Rubber or neoprene all conforming to drinking water standards.The flow meter should be coupled with HART data acquisition and transfer, with provision for wireless transfer through GSM. The manufactures should have the calibration standards as per ISO 17025 and product shall have sufficient warranty provisions.as per KWA circular.Test certificate from FCRI palakkad.
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
OD271711/2023-2024:GIS mapping, Drawings soft copy and hard copy submitted on each bill, and finally submitted the full data.GIS mapping coordinates of regular intervals regarding sizes and locations of pipes, valves, and other all attributes in order to proper asset management and future servicing of the system and in order to upload in Google map.Drawings soft copy and hard copy(4Nos) with final bill .As per the Circular issued by the CE)SR) The GIS map soft copy and hard copy to be submitted to Jalabhavan (GIS wing) through the concerned EE in order to upload to the web site
Supply, erection and commissioning of VT raw water pumpsets and allied electrical works
Supply, installation and commissioning of 630KVA , 11KV/433 V indoor transformer and allied electrical works
OD225182/2023-2024:Supply, Installation, testing and commissioning of Transformer with KEI standards and their approval 630 KVA , 11KV/433 V 50c/s, Cast resin dry type, vector group DYN-11, copper wound indoor type, with cable box at the 11KV side and LT side, OFF load tap at the 11KV side, H.V.Compartment which houses Vacuum Circuit Breaker (VCB) or Load Break Switch (LBS), the transformer compartment which houses dr y type /oil cooled transformers & the LV compartment which houses ACB, MCCB, SFU etc. . All components are to be housed in an enclosure which protects the equipment against environmental hazards & unauthorized access . The electrical equipments are to be cooled by natural ventilation including all cost and erection charge and Electrical Inspectorate and KSEB charges
OD225183/2023-2024:Supplying and installation of control desk including on /off push button 8nos, multi function meter 4nos, including all control wiring and cables for each motor from main switch board etc complete as per directions
OD225184/2023-2024:Supply, Fabrication, Installation, Testing and Commissioning of Cubicle type, dust and vermin proof, floor mounted, front operated APFC Panel (250kVAR) made out of 16SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel, switch board having a set of suitably rated TPN Aluminium Busbars with the specified current and fault level, insulated with heat shrinkable, colour coded PVC sleeves and supported using DMC/SMC piller or finger type Busbar supports consisting of the following - 630A TPN Isolator 1No Multifunction Meter 1No CT 600/5A 15VA CL-1 3Nos APFC Relay (12Way) 1No 125A 3P MCCB 2No 63A TP MCB 5Nos 40A TP MCB 2Nos 32A TP MCB 2Nos 50kVAR Capacitor Duty Contactor 2Nos 25kVAR Capacitor Duty Contactor 2Nos 20kVAR Capacitor Duty Contactor 2Nos 15kVAR Capacitor Duty Contactor 3No 10kVAR Capacitor Duty Contactor 1No 5kVAR Capacitor Duty Contactor 1No 50kVAR Capacitor (APP) 2No 25kVAR Capacitor (APP) 2Nos 20kVAR Capacitor (APP) 2Nos 15kVAR Capacitor (APP) 3Nos 10kVAR Capacitor (APP) 1No 5kVAR Capacitor (APP) 1No
OD225185/2023-2024:Preparation of schematic diagram,earthing arrangements , physical layout site plan and submitting to the Electrical inspectorate for getting necessary approval and obtaining energisation sanction from the Electrical inspectorate.,Preparation of necessary drawings, submitting completion report, getting power supply from KSEB
OD225186/2023-2024:Providing light wiring arrangements (Single phase) in the sub station room including supplying and fitting meter board with single phase 15A main switch, fuses etc. as per KSEB rules.
OD225187/2023-2024:Termination unit for emergency push button arrangments
OD225188/2023-2024:Supplying and laying 2 core 2.5mm copper cable for emergency push botton arrangements
OD225189/2023-2024:Arrangements of soil resistivity certificate
OD225190/2023-2024:Supply all materials and Fabrication and erection of cable trays /cable supports fabricated out of MS angles and M S flats of adequate size with sufficient width and spacing between sucessive cross members and supports at adequate spacing . The cable trays and supports shall be painted with 2 coats of zinc chromate primer and 2 coats of enamel paint
OD225191/2023-2024:Supply and installation of the following for fire protection.<br> H.T. Rubber mat 1/2'' thick- 3Nos L.T. Rubber mat 1/4'' thick - 2 Nos H.T.gloves - 2 pair Fire bucket with single stand -3 Nos HT Danger board - 1Nos LT Danger board - 6 Nos Fire extinguisher(5 KG DCP type) - 2 Nos Shock treatment chart - 1Nos First aid box - 2Nos
OD264690/2023-2024: Supply &termination of the following aluminium armoured LT cables through existingcable trench or cable trays using suitable accessories like cable gland, aluminium crimping socket etc . 3.00x300 Sq mm Al ar.cable
OD264694/2023-2024:Supply &termination of the following aluminium armoured LT cables using cable gland, aluminium crimping socket etc . 4 x 16 Sqmm Al ar cable
OD225194/2023-2024:Supply and laying following Swg 10 copper conductor
OD225195/2023-2024:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm
OD225196/2023-2024:Providing and laying G.I. tape 32 mm X 6 mm in ground as required
OD225197/2023-2024:Earthing with G.I. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD225198/2023-2024:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
OD225199/2023-2024:Supply of Compact 630A Sandwich Busway System Totally Type Tested in accordance with IEC61439-6, of below mentioned rating 630A, 3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earth strip, IP65in accordance to IEC 60529, housed in electrogalvanised sheet steel and aluminium enclosure,ANSI 49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification.
OD225200/2023-2024:Supply and laying 1 Run of240 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE
OD225201/2023-2024:Supply and fixing of neutral CT 200/5A, CL.5P10, 15VA on suitable enclosure
OD225202/2023-2024:Supply all materials and fixing of emergency push button with enclosure
OD225203/2023-2024:Supply and fixing of HT TOD meter including testing
OD225204/2023-2024:Charges for Supply transporting the 11 kv CTunits and testing to the laboratories of KSEB and procuring approval for them.<br><br>
OD225205/2023-2024:supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :3x 300 sqmm
OD225206/2023-2024:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 3x300 sq.mm
OD225207/2023-2024:Supply and laying HT 3.5 core 300 sqm stranded compact circular aluminium conductor,<br>conductors screened with extruded semi conducting compound XLPE<br>insulated, insulation screened with extruded semi conducting compound<br>in combination with copper tape (0.3KA for I sec.) cores laid up. inner<br>sheath of PVC tape, galvanized steel flat strip armoured, and overall<br>PVC sheathed cable conforming to IS: 7098 part II 1985 with latest<br>amendment
OD225208/2023-2024:Supply erection testing and commissioning of 16 swg cubicle type panel with<br> 1250 A, 3 pole, manual draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA, 800A 3P ACB - 5 NOS, 630A 3P MCCB 1 NO, 400A 3P MCCB 1 NO including all necessary protection and meters - ACB PANEL
Construction of Transformer room
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.36:Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
9.97.1:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
13.71:Lettering with black Japan pint of approved brand and manufacture
11.26.1:Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick
Construction of valve chamber inside dimension V1- 150x150, V2-70x70cm
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD225181/2023-2024:Supplying and fixing C.I with cover and frame for manholes;560 mm diameter (heavy duty) the weight to be not less than 208Kg.
Road restoration of LSGD road
4.1.A.3:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (iii) For Grading III Material
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.1a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.11.1.A.5:Mix Seal Surfacing Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 By Manual Means Type A (V) Natural Rubber Modified Bitumen
Bidder Name
BIJU AUGUSTINE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.74 MB
Tendernotice_2.pdf
PDF • 1.19 MB
Tendernotice_3.pdf
PDF • 1.07 MB
Tendernotice_4.pdf
PDF • 20.50 MB
BOQ_1031463.xls
BOQ • 0.32 MB
Q1Q8.xls.xls
Other Document • 0.10 MB
Download all tender documents and submit your bid