Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹13.0 L+₹21,480 (1.69%)Rejected-Finance | L2 | Rejected-Finance other than lowest bidder |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
11 Jun 2020, 6:00 pmClosed
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT PIN-133001
REPAIR AND MAINT OF NON CLOG SEWAGE SUBMERSIBLE PUMP SETS OF CAP 5 HP TO 60 HP AND CONNECTED ITEMS UNDER GE UTILITY AMBALA CANTT
2020_MES_343953_1
GE(U)/AMB-08/2020-21
Open Tender
Civil Works
Item Rate
180 days
AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹28,000
Yes
6 Oct 2020
14 May 2020
13 Jun 2020
14 May 2020
11 Jun 2020
28 May 2020
14 May 2020 - 27 May 2020
Amount
Taking out Non Clog submersible sewage pumping set from sewage well foundation (after and including dewatering of sewage well) of 60 HP capacity Make - Kirloskar by lifting and dismantling the same for assesing and carrying out the repair/servicing and replacement of unserviceable parts with new parts as listed in subsequent items and making good in running condition with hydraulic air testing and balancing, reassembling and lowering the same in well & fixing on the foundation making connections and testing complete all as specified & directed by Engrineer-in-Charge. Note :- (a) The replaceed parts of pump shall be measured & paid separately here-in-after as supply only. (b) Dewatering of sewage well shall be included in the quoted rate of item.
Description all as per Srl Item No 1 here-in-before but of Capacity 40 HP
Description all as per Srl Item No 1 here-in-before but of Capacity30 HP
Description all as per Srl Item No 1 here-in-before but of Capacity 20 HP
Description all as per Srl Item No 1 here-in-before but of Capacity 7.5 HP to 10 HP
Description all as per Srl Item No 1 here-in-before but of Capacity 3 HP to 5 HP
Taking out old unserviceable lubricating oil from the chamber, cleaning and refilling the fresh lubricating oil complete all as specified & directed by Engrineer-in-Charge.
Rewinding of motor 60 HP non clog submersible sewge pumping set Make - Kirloskar with suitable size and proper guage of copper winding wire using best quality of insulation material provided with thermal switches for protection against excessive temp flee and replacing O ring set full fastner set, nitrile O ring and bearing, seals and varnish the motor using fine quality varnish complete all as specified & directed by Engrineer-in-Charge. Note : Parts replaced will be measured and paid for as supply only.
Description all as per Srl Item No 8 here-in-before but cap of pump motor 40 HP.
Description all as per Srl Item No 8 here-in-before but cap of pump motor 30 HP.
Description all as per Srl Item No 8 here-in-before but cap of pump motor 20 HP.
Description all as per Srl Item No 8 here-in-before but cap of pump motor 7.5 to 10 HP.
Description all as per Srl Item No 8 here-in-before but cap of pump motor 3 to 5 HP.
Supply only CI impeller with guide bush suitable for 60 HP Non clog submersible sewage pumping set complete all as specified & directed by Engrineer-in-Charge.
Description all as per Srl Item No 14 here-in-before but cap of pump 40 HP
Description all as per Srl Item No 14 here-in-before but cap of pump 30 HP
Description all as per Srl Item No 14 here-in-before but cap of pump 20 HP
Description all as per Srl Item No 14 here-in-before but cap of pump 7.5 to 10 HP
Supply only lubricated upper/lower bearing No C3 ATNS - 3308 for non clog submersible pump complete all as specified & directed by Engrineer-in-Charge.
Description all as per Srl Item No 19 here-in-before but C3 ATNS-3313 -do-.
Description all as per Srl Item No 19 here-in-before but 6312 -do-.
Description all as per Srl Item No 19 here-in-before but 6310 -do-.
Description all as per Srl Item No 19 here-in-before but 6309 -do-.
Description all as per -Srl Item No 19 here-in-before but 6313 -do-.
Supply only hard metal double upper and lower mechanical seal assembly combination for non clog submersible pump, of capacitor 60 HP complete all as specified & directed by Engrineer-in-Charge.
Description all as per Srl Item No 25 here-in-before but cap of pump 40 HP
Description all as per Srl Item No 25 here-in-before but cap of pump 30 HP
Description all as per Srl Item No 25 here-in-before but cap of pump 20 HP
Description all as per Srl Item No 25 here-in-before but cap of pump 7.5/ 10 HP
Supply and fix in replacement PVC insulated submersible copper cable flat/round of size 10 Sqmm 3 core complete all as specified & directed by Engrineer-in-Charge.
Description all as per Srl Item No 30 here-in-before but 16 Sqmm 3 core.
Description all as per Srl Item No 30 here-in-before but 25 Sqmm 3 core.
S&F in replacement CI column pipe both end flanged ISI marked of size 100 mm dia including lowering down the column pipe complete all as specified & directed by Engrineer-in-Charge.
Supply and fix in replacement MS adjustable spiral bottom plate suitable for 40 to 60 HP Motor complete all as specified & directed by Engrineer-in-Charge.
Description all as per Srl Item No 34 here-in-before but for size 20 to 30 HP motor.
Description all as per Srl Item No 34 here-in-before but for 7.5 HP to 10 HP motor.
Supply and fix in replacement Shaft AISI -410 suitable for 20 to 30 HP motor all as directed.
Description all as per Srl Item No 37 here-in-before but suitable for size 40 to 60 HP motor.
Supply and fix in replaement MS hexagonal nut and washers MS Steel eye Bolts, Allen Screws etc ISI Marked.
S&F in replacement GI tubing medium grade 40 mm dia complete all as specified & directed by Engrineer-in-Charge.
S&F in replacement Rubber gasket 150 mm dia ISI marked complete all as specified & directed by Engrineer-in-Charge.
Description all as per Srl Item No 41 here-in-before but 100 mm dia -do-
S&F in replacement profile gasket (MS bracket) 100 mm dia ISI marked suitable for non clog submersible pump complete all as specified & directed by Engrineer-in-Charge.
M&L PCC foundation of size 75cmX75cmX20cm with PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including 8 mm thick ms base plate of size 40cmX40cm suitable for 40 to 60HP Non clog Submersible Pump including self drill bolt of size 150mm long and 15mm dia of shank fully threaded 04 Nos made of stainless steel complete all as specified & directed by Engrineer-in-Charge. Note : The platform shall be constructed in sewage well of approximate 12mtr deep including dewatering of water and taking out of sewage if required and the contractor shall quote rate keeping in view the depth of sewage well and dewatering.
S&F in replacement Single phase preventor suitable for low/high voltage cut, over current, phase failure complete all as specified & directed by Engrineer-in-Charge.
S&F in replacement over load relay suitable for 60 HP motor complete all as specified & directed by Engrineer-in-Charge.
Description all as per Srl Item No 46 here-in-before but 40 HP motor.
Description all as per Srl Item No 46 here-in-before but 20 HP motor.
Description all as per Srl Item No 46 here-in-before but 10 HP motor.
S&F in replacement 3 pole power contactor 415 volt, NO & NC 110 Amp type-MDX110 Cat Part No C596558 complete all as specified & directed by Engrineer-in-Charge.
S&F in replacement 3 pole power contactor 415 volt, NO & NC 95 Amp type-MDX95 Cat Part No CS96557 complete all as specified & directed by Engrineer-in-Charge.
S&F in replacement 3 pole power contactor 415 volt, NO & NC 80 Amp type-MDX80 Cat Part No CS96556 complete all as specified & directed by Engrineer-in-Charge.
S&F in replacement 3 pole power contactor 415 volt, NO & NC 50 Amp type-MDX50 Cat Part No CS96554 complete all as specified & directed by Engrineer-in-Charge.
S & F in replacement electronic overload relay 0.6 to 60A 220 V complete all as specified & directed by Engrineer-in-Charge.
S & F in replacement fully automatic citation star delta starter in sheet metal enclosure with contactor & Penumatic timer of cap 50 HP 3 phase complete all as specified & directed by Engrineer-in-Charge.
S & F in replacement fully automatic citation star delta starter in sheet metal enclosure with contactor & Penumatic timer of cap 40 HP, 3 phase complete all as specified & directed by Engrineer-in-Charge.
S & F in replacement fully automatic citation star delta starter in sheet metal enclosure as in repair with contactor & Penumatic timer of cap 10 to 30 HP, 3 phase complete all as specified & directed by Engrineer-in-Charge.
Supply and fix cast iron sluice valve PN-1.6 with flanged ends 200 mm nominal bore ISI marked complete with gun metal or stainless steel spindle and cast iron cap including rubber /fiber board gasket nuts, washers etc including taking down old unserviceable sluice valves complete all as specified and as directed by Engineer-in-Charge
Dscription all as per item No 58 here-in-before but 150mm dia.
Supply & fix in replacement MS nut, bolts and washers of size 5/8" x 3", 5/8" x 4" long complete all as specified & directed by Engrineer-in-Charge.
Supply & fix in replacement rubber gasket joint for 150mm dia CI pipe complete all as specified & directed by Engrineer-in-Charge.
Dscription all as per item No 61 here-in-before but 200mm dia CI pipe.
M&L earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less than 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wirewith GI strip of 32 x 6mm by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through and including 40mm dia GI pipe for protection including 20mm dia GI pipe for watering GI funnel , PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing all as directed by Engr-In-Charge.
Desilting/cleaning of sewage well of depth 12 Mtr and 9 Mtr dia taking out sludge in the form of solid manually and getting out and removal to a distance exceeding 250mtr but not exc 500 Mtr and burried the same in low laying area as directed by Engineer-in-Charge
M/s Guddu Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .