GE AF AMBALA
GE AF AMBALA
GE AF/AMB-67/2020-21 REPLACEMENT OF GEYSERS, CEILING FANS AND EXHAUST FANS AGAINST BER AT AF STATION AMBALA UNDER GE (AF) AMBALA
2021_MES_429768_1
GE AF/AMB-67/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE AF AMBALA
₹28,800
Yes
8 Jun 2021
11 Mar 2021
10 Apr 2021
11 Mar 2021
8 Apr 2021
26 Mar 2021
18 Mar 2021 - 23 Mar 2021
Amount
M&L for taking down unserviceable water heaters (geysers) 25/50litres capacity from existing location / position including disconnecting from electric and water connections and depositing in MES store yard complete all as specified and as directed
M&L for taking down unserviceable ceiling fans 1200mm sweep from existing location / position including disconnecting from electric connections and depositing in MES store yard complete all as specified and as directed
M&L for taking down unserviceable exhaust fans 300mm sweep with louvers from existing location / position including disconnecting from electric connections and depositing in MES store yard complete all as specified and as directed
Notes for item Nos. 1 to 3: (i) Geysers, ceiling fans, exhaust fans shall be taken down from any location, height, positions, etc. as per site (ii) Disconnection from mains and supply shall be done with requisite safety measures (iii) All cost of loading, unloading, carting, T&P, etc. as required to deposit taken down items to MES storeyard shall be deemed to be inclusive in the quoted rates
S&F electric water heaters (geysers), steel body, 25litres capacity, storage type, vertical mounting, with glass lined inner tank, energy efficient 5 star rated of approved design and colour, including all necessary clamps, grouting duly with holding bolts & nuts and all necessary connections at locations complete all as specified and as directed
S&F electric water heaters (geysers), steel body, 50litres capacity, storage type, vertical mounting, with glass lined inner tank, energy efficient 5 star rated of approved design and colour, including all necessary clamps, grouting duly with holding bolts & nuts and all necessary connections at locations complete all as specified and as directed
S&F heavy duty, steel body with metal blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 230/240V, single phase, 450mm sweep with lauvers and connecting up including cutting into brick walls to make suitable opening, making good the inside surfaces of holes in CM 1:4, etc. and provisioning of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts complete all as specified and as directed
S&F energy efficient BEE five star rated ceiling fan, 230/240V, single phase, 1200mm sweep and connecting up with provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to ceiling fan complete all as specified and as directed
S&F steel water tubing, 15mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS: 1239 fixed to walls / ceilings or laid in floor / trenches or as inlets of geysers duly cut to required shape and size complete all as specified and as directed
S&F 15mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. for cold water connection of geysers complete all as specified and as directed
S&F 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. for hot water connection of geysers complete all as specified and as directed
S&F metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket with and inlcuding one SP MCB 20A 10kA 240V and testing on installation complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core 4sqmm, PVC insulated, FRLS unsheathed suitable for 1100V multistranded copper conducter cable and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked concealed in wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
Notes for item No. 14: (i) 2 runs of 4sqmm main cable, 1 run of 2.5sqmm earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
Dashmesh Enterprises
M/S HARCHARAN SINGH
The Rahul Vig
M/S Sonu Traders
UNITED ENGINEERING CORPORATION
Baliyan Electrical Works
Swami Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .