Tender Value
₹52 L
EMD Value
₹1.0 L
Closing Date
31 Jul 2026, 12:00 pm5d left
Exe.Engr._I, KSHED, P.W.Dte.
75 D H Road Kidderpore Kol_23
IPGMER-SSKM Hosp.- Prov. FDS, Fire Damper System at Fire Control Room Emerg. Escape lighting as per Revised Fire safety Recom. of Trauma Care Centre (G X), New OPD bldg (B G Viii), Sports Medicine(G III) and BIN New OPD bldg (G VIII)_SITC of FDS
2026_WBPWD_5016700_1
WBPWD/EE-I/KSHED/Q25/26-27
Open Tender
FIRE FIGHTING ORG
Item Rate
90 days
SSKM Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.0 L
O/o EE, KSHED, P.W.Dte.
13 Jul 2026
13 Jul 2026
3 Aug 2026
13 Jul 2026
31 Jul 2026
21 Jul 2026
20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing & Commisioning of Microprocessor based addressable fully networkable fire alarm control panel ( VDS / UL / FM /ULC / LPCB / approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to NBC / IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice. | 1 | No. | - | - |
| 1.01 | The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. | - | - | - | - |
| 1.02 | The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software. (Approved Make : Cerberus Pro / Johnson Controls / Securiton/Edward) | - | - | - | - |
| 2 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 (VDS / UL / LPCB / FM / ULC approved) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Johnson Controls / Securiton/Edward) | 250 | Items | - | - |
| 3 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat Detector (VDS / UL /LPCB / FM / ULC approved) with combination of fixed type and rate of rise of tempature feature.Detector shall have maximum triggering temparature programmable from 60 deg C to 80 der C having high level of immunity to electromagnetic influence and show alarm signal limit temparature is reached.Detector shall have inbuild short circuit fault isolation as per NEPA style 7 wiring complete with base(Note Detector without built in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost the detectors should have built in response indicator with LED indicator.(Approved Make : Cerberus Pro /Johnson Controls/Securiton/Edward) | 10 | Nos | - | - |
| 4 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( FM / ULC / VDS / UL/LPCB approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Cerberus Pro / Johnson Controls / Securiton/Edward) | 15 | Nos | - | - |
| 5 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( FM / ULC / VDS / UL / LPCB approved) approved. (Approved Make : Cerberus Pro / Johnson Controls / Securiton/Edward) | 15 | Nos | - | - |
| 6 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make.Havells / Gloster / RR Kable / Polycab) through 19 mm dia PVC 'FR' type Rigid Conduit pipe including S & laying of the 19 mm dia PVC 'FR' type Rigid Conduit pipewith necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 480 | Mtrs. | - | - |
| 7 | Supply & Fixing of motorised Fire damper made out of 18 G GI sheet and frame with actuator , control circuit compateble with fire detection system (3 rd Party).[Make - Systemair / Air Enterprise / Premire/ Caryaire / Airmaster] | 30 | Sq.Mtr. | - | - |
| 8 | S&F of control panel for interlock between Fire Alam system and AHU of AC system in SS encloser (1.6 mm thick) with power coated with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of suitable copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall icl necessary connections as per direction of EIC:- | 75 | Sets | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
TenderForm.pdf
Tender Documents • 0.69 MB
BOQ_5086393.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].