Loading…
Loading…
Tender Value
₹3.3 Cr
EMD Value
₹3.3 L
Closing Date
1 Apr 2026, 6:10 pmClosed
Office of The Executive Engineer, Panchayat (R&B) Division, Chhotaudepur
Construction of Taluka Panchayat office building at Kawant Ta. Dist : Chhotaudepur Under CDP-3 (2025-26)
289261
14 of 2025-26
Open
Civil Works - Buildings
Works
Chhotaudepur
₹6,000
Executive Engineer, Panchayat (R&B) Division, Chhotaudepur
₹3.3 L
24 Mar 2026
24 Mar 2026
24 Mar 2026
1 Apr 2026
24 Mar 2026
Name of Work :- Construction of Taluka Panchayat office building at Kawant Ta. Dist :
Chhotaudepur Under CDP-3 (2025-26)
Sr No. Clause no Page
1 Principle Approval Date and - - :- CDP-3 (2025-26)
Amount (Attach letter)
2 Administrative Approval Date and - - :- PRHRDD/JRT/e-file/ 14/ 2022/
Amount (Attach letter ) 2710/section-J Dtd.11/07/2025 for Rs.
398.00 lacs Under CDP-3 Year 2025-26
3 Technical Approval Date and - - :- Ts. For Rs 3,98,00,000.00 By S.E.Panchyat
Amount (Attach letter) ,R & B Vadodara Circle , as per Sr No.477
Pg No.85 in Dtd. 28-01-2026
5 DTP amount IFB 4 :-
6 Tender Fee Rs. - - :- 6000.00 Rs
(As per GR- PRCH-102000-IB-
Above 10.0 Cr.- Rs 18000)
7 Earnest Money Deposit (Bid IFB 4 :-
Security-1% of DTP amount) Rs. point 6
8 Time Limit (Months) Section 3 41 :- 12 (months) including Monsoon
9 Annual Financial Turnover Section 1 cl. 9 :-
Amount Rs. 4.5.3(a)
10 Defect Liability Period (In Section 3 46 :-
Months & includes no. of cl. 33.1 ( C ) 48 Months (including 4 monsoons)
11 Free Maintenance Guarantee Period Section 3 46 :-
(for Road & Bridge Construction) cl. 33.2 (b)
12 Registration/Category - - :- "A” class with Sp. Cat II for Building
required and above
13 Site Possession Date Section 3 42 :- 1st day of Work order#
14 Period between Program Update Section 3 44 :- 30 days
15 Amount to be withheld for late Section 3 44 :- 1.00 Lakh
submission of Program cl.
16 Milestone: - Section 3 53 :- % of work Days
(A) Milestone 1 - - :- 10% 92 Days
(B) Milestone 2 - - :- 40% 184 Days
(C) Milestone 3 - - :- 80% 275 Days
(D) Milestone 4 - - :- 100% 365 Days
#In case of LA/FRA is in progress give likely date.
17 Price Adjustment Components Section 4 66 :- % Input index/price*
(A) Labour, PL Section 4 66 :- PL= 28.56% Lo=
(B) Cement, PC Section 4 66 :- PC= 9.06% Co=
(C) Steel, PS Section 4 67 :- PS= 21.66% So=
(D) Bitumen, Pb Section 4 67 :- Pb= 0.00% Bo=
(E) POL, Pf Section 4 68 :- Pf= 2.47% Fo=
(F) Plant and Machinery Spares Pp Section 4 68 :- Pp= 12.24% Po=
(G) Other Materials, Pm Section 4 69 :- Pm= 26.01% Mo=
18 Amount to be withheld for Section 3 56 :-
failing to supply “as built” cl.
19 Percentage Rate Contract Section 7 78 :-
(upto INR 50 Cr. )/ Item Rate
Percentage Rate
Contract (above INR 50 Cr.)
*Input index/price for each component on 28 days preceding the date of opening of technical bid shall be
This is to certify that the contract document prepared for the work
Construction of Taluka Panchayat office building at Kawant Ta. Dist : Chhotaudepur
Under CDP-3 (2025-26)
is based on the Standard Bidding Document Procurement of Civil Works published by
R&B department letter No. RBD/0346/10/2023 dated 12/10/2023.
No further modification and alteration in this standard format has been made by this office.
Deputy Executive Engineer Executive Engineer
Panchayat (R & B) Sub Division Panchayat (R&B) Division
Chhotaudepur Chhotaudepur
Name of Work :- Construction of Taluka Panchayat office building at Kawant Ta. Dist :
Chhotaudepur Under CDP-3 (2025-26)
SPECIFICATION INDEX
It. Applicable specification
Description of Item
1 Excavation for Foundation upto 1.5 m depth including Sorting out and stacking of As per Separate Sheet
useful materials and disposing of the excavated stuff upto 50 M. Lead.(a) Loose or attached.
2 Excavation for Foundation from 1.50m to 3.0m depth including Sorting out and As per Separate Sheet
stacking of useful materials and disposing of the excavated stuff upto 50 M. Lead. attached.
(B) Dense or Hard soil.
3 Brick work using common burnt Clay building bricks having crushing strength not As per Separate Sheet
less than 35 kg / sq.cm in foundation and plinth in Cement mortar 1:6 (1 Cement : attached.
6 fine sand) (b) Conventional
4 Brick work using common burnt Clay building bricks having crushing strength not As per Separate Sheet
less than 35 kg / sq.cm in foundation and plinth in Cement mortar 1:6 (1 Cement : attached.
6 fine sand) (b) Conventional (GF)
5 Providing and laying controlled cement concrete M.150 and curing complete As per Separate Sheet
including the cost of formwork in (A) Foundations and plinth . attached.
6 Providing and laying Controlled cement concrete M.250 work with curing etc. As per Separate Sheet
complete including the cost of formwork but excluding the cost of reinforcement for attached.
R.C.C. work in for Foundation footing base of columns.
7 Providing and laying controlled cement concrete M.250 and curing etc. complete As per Separate Sheet
including the cost of formwork but excluding the cost of reinforcement for R.C.C. attached.
work in for COLUMNS Up to Plinth Level
8 Providing and laying controlled cement concrete M.250 and curing etc. complete As per Separate Sheet
including the cost of formwork but excluding the cost of reinforcement for R.C.C. attached.
work in for COLUMNS for super structure.
9 Providing and laying controlled cement concrete M-250 and curing etc. complete As per Separate Sheet
including the cost of formwork but excluding the cost of reinforcement for R.C.C. attached.
work in for COLUMNS for First floor.
10 Providing and laying controlled cement concrete M-250 and curing etc. complete As per Separate Sheet
including the cost of formwork but excluding the cost of reinforcement for R.C.C. attached.
work in for COLUMNS for Second floor.
11 Providing and laying controlled cement concrete M.250 work with curing etc. As per Separate Sheet
complete including the cost of formwork but excluding the cost of reinforcement for attached.
R.C.C. work in for BEAMS upto plinth level.
12 Providing and laying controlled cement concrete M.250 work with curing etc. As per Separate Sheet
complete including the cost of formwork but excluding the cost of reinforcement for attached.
R.C.C. work in for BEAMS above plinth level.
13 Providing and laying controlled cement concrete M.250 work with curing etc. As per Separate Sheet
complete including the cost of formwork but excluding the cost of reinforcement for attached.
R.C.C. work in for BEAMS for First floor.
14 Providing and laying controlled cement concrete M-200 work with curing etc. As per Separate Sheet
complete including the cost of formwork but excluding the cost of reinforcement for attached.
R.C.C. work in for Slab for Ground floor.
15 Providing and laying controlled cement concrete M-200 work with curing etc. As per Separate Sheet
complete including the cost of formwork but excluding the cost of reinforcement for attached.
R.C.C. work in for Slab for First floor.
16 Providing and laying controlled cement concrete M-200 work with curing etc. As per Separate Sheet
complete including the cost of formwork but excluding the cost of reinforcement for attached.
R.C.C. work in for Slab for Second floor.
17 Filling available excavated earth (excluding Rock) in trenches, plinth, sides of As per Separate Sheet
foundation etc. in layers not exceeding 20.cm. in depth consolidating each attached.
deposited layer by ramming and watering.
18 Filling in foundation and plinth with murrum or selected soil in layers of 20cm. As per Separate Sheet
thickness including watering, ramming and consolidating etc. completed. attached.
It. Applicable specification
Description of Item
19 Filling in plinth with sand under floors including watering ramming, As per Separate Sheet
consolidating and dressing etc. Complete attached.
20 Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- As per Separate Sheet
handbroken stone aggregates 40 mmnominal size) and curing complete excluding attached.
cost of formwork in Foundation and Plinth (flooring concrete)
21 Providing and laying Damp proof course 25mm thick cement concrete 1:2:4 (1 As per Separate Sheet
Cement : 2 coarse Sand : 4 stone aggregate 10 mm nominal size) and Curing attached.
22 Brick work using common burnt Clay building bricks having crushing strength not As per Separate Sheet
less than 35 kg / sq.cm in super structure above plinth level up to floor two level in attached.
Cement mortar 1:6 (1 Cement : 6 fine sand) (b) Conventional (F.F)
23 Brickwork using common burnt clay building bricks having crushing strength not As per Separate Sheet
less than 35 kg./Sq.cm. in super structure above plinth level up to floor two level in attached.
Cement Mortar 1:6 (1 Cement : 6 fine sand) (B) Conventional for First Floor
24 Brick work using common burnt Clay building bricks having crushing strength not As per Separate Sheet
less than 35 kg / sq.cm in super structure above floor level 3 in C.M 1:6 (1 Cement attached.
: 6 fine sand) (b)Conventional
25 Half brick masonary in common burnt Clay building bricks having crushing As per Separate Sheet
strength not less than 35 kg / sq.cm in in C.M 1:3 (1 Cement : 3 coarse sand) in attached.
with 2 nos. of 6 mm dia.mild steel round bars after every three coarse embedded
in cement mortar in super structure above plinth level up to floor two level
26 Half brick masonary in common burnt Clay building bricks having crushing As per Separate Sheet
strength not less than 35 kg / sq.cm in in C.M 1:3 (1 Cement : 3 coarse sand) in attached.
with 2 nos. of 6 mm dia.mild steel round bars after every three coarse embedded
in cement mortar in super structure above floor two level.
27 Providing and fixing colour anodised single/double shutters having standard As per Separate Sheet
extruded alluminium colour anodized hollow sections frame Equvalent to Jindal attached.
Door section No.19552 of size 38 mm x 63.5 mm (aproximate wt. 1.2 kg per Rmt)
with wooden inserts for Durable grip of door hinges. with 3.8 cm th. shutter flush
door solid core finished with 1 mm Lamination on Both side with S.S Handle &
other Fixtures . complete
28 Providing and fixing FRP frame size 100 x 50 mm and 35 mm thick FRP depress As per Separate Sheet
panel Shutter with 3.2 mm High Dencified moulded wood fiber skin with steel attached.
hinges having extra reinforcement on sides & edges in Gel coat finish. The core of
the shutter & frame is to be filed up with injected fire retardant grade polyurethene
foam done in situ alongwith embedded wooden pieces for stiffening & also taking
hinges & fintures. The whole FRP frame & shutter is to be water proof weather
proof, termite proof & resistance to mild acid/alkali. Rates are to be inclusive of S.S
hinges with necessary screws & alluminium fixtures & fastenings & fastener
29 Providing and fixing Standrad extrured alluminium window having extruded As per Separate Sheet
alluminium colour anodised section frame (Weight 1.094 Kg /Rmt) with partly attached.
fixed & partly sliding shutters with 5 mm thick transparent bronze colour tinted
float glass with transperent silicon Gasket with Alluminium powder coated fitting &
Fixture. for Window
30 Providing and Fixing standard extruded alluminium section of size 95 mm x 24 mm As per Separate Sheet
x 0.95 mm (Jindal Section no: 2458, wt @ of 0.601 kg/m) with colour anodized attached.
alluminium frame for Ventilation with 3 mm thick Bajari Figured Adgesteble glass
louvers of Standrad make as details etc complete for Ventilation
31 Providing and Fixing polished Green marble stone with moulding around Sill & As per Separate Sheet
Jamb of Window attached.
32 Providing and fixing M.S grills of required pattern 16 mm Dia round Polished bars As per Separate Sheet
with M.S flats, fixing to masonary or R.C.C as directed including one coat of red attached.
oxide and two coats of red oxide and two coats oil paintings etc. complete …
It. Applicable specification
Description of Item
33 Providing & Fixing M S railing with 3 - Raw M S Flats of 50 x 12 mm size and As per Separate Sheet
Teak Wood hand Rail incl. 25 mm thick M S bars at 15 cms center ot center with attached.
necessary welding bolting as necessary including Enamel paint etc. complete.
34 Providing and laying Controlled cement concrete M-200 and curing complete As per Separate Sheet
including the cost of form work and excluding the cost of reinforcement for attached.
reinforced concrete work for R.C.C LINTEL.
35 Providing and laying Controlled cement concrete M-200 and curing complete incl. As per Separate Sheet
the cost of form work and excluding the cost of reinforcement for reinforced attached.
concrete work for RCC LINTEL.
36 Providing and laying Controlled cement concrete M-200 and curing complete As per Separate Sheet
including the cost of form work and excluding the cost of reinforcement for attached.
reinforced concrete work for R.C.C Chhajas.
37 Providing and laying Controlled cement concrete M-200 and curing complete incl. As per Separate Sheet
the cost of form work and excluding the cost of reinforcement for reinforced attached.
concrete work for R.C.C Chhajas.
38 Providing and laying controlled cement concrete M.200 and curing complete As per Separate Sheet
including the cost of formwork and excluding reinforcement for reinforced attached.
concrete work in For Vertical and Horizontial fins upto floor two level.
39 Providing and laying Controlled cement concrete M-200 and curing complete As per Separate Sheet
including the cost of form work and excluding the cost of reinforcement for attached.
reinforced concrete work for Horizontal and Vertical R.C.C Fins.
40 Providing and laying Controlled cement concrete M-200 and curing complete As per Separate Sheet
including the cost of form work and excluding the cost of reinforcement for attached.
concrete work in Staircase for all floors incl.Finishing the exposed work with
cement mortar to give smooth even surface.
41 Providing and laying Controlled cement concrete M-200 and curing complete As per Separate Sheet
including the cost of form work and excluding the cost of reinforcement for attached.
concrete work in Staircase for all floors incl.Finishing the exposed work with
cement mortar to give smooth even surface.
42 Providing T.M.T Fe 500 D Reinforcement for R.C.C work including bending As per Separate Sheet
binding and placing in position complete up to floor two level. attached.
43 Providing & Laying 24" x 24" Vitrified 8 mm thick tiles Flooring over 20 mm As per Separate Sheet
(average) base of Cement Mortar 1:6 (1 Cement: 6 Coarse Sand) on new surface attached.
or fixing on exiting flooring by adhesive material including dismentalling of exiting
flooring & jointed with colour cement slurry including finishe with flush pointing &
cleaning the surface etc. complete. For dark shade with colour pattern.
44 Providing & Laying Vitrified Flooring Tiles 8 mm thick in Skirting, Risers of Steps As per Separate Sheet
& dado on 10 mm thick Cement Plaster 1:3 (1Cement:3 Coarse Sand) & Jointed attached.
with white cement slurry.
45 Providing & Laying 24" x 24" Vitrified 8 mm thick tiles Flooring over 20 mm As per Separate Sheet
(average) base of Cement Mortar 1:6 (1 Cement: 6 Coarse Sand) on new surface attached.
or fixing on exiting flooring by adhesive material including jointed with colour
cement slurry including finishe with flush pointing & cleaning the surface etc.
complete.For Antiskid.
46 Providing & Laying Ceramaic Flooring Tiles in Skirting, Risers of Steps & dado on As per Separate Sheet
10 mm thick Cement Plaster 1:3 (1Cement:3 Coarse Sand) & Jointed with white attached.
47 Providing and laying Mirror polished Granite flooring over 20 mm (average) thick As per Separate Sheet
base of cement mortar 1 : 6 (1 cement : 6 course sand) or L.M. 1 : 1.5 laid over attached.
and jointed with grey cement slurry including rubbing and polishing etc. complete
48 Providing and laying Mirror polished Granite 20 mm thick in risers of steps, dado As per Separate Sheet
and pillars laid on 10 mm thick cement mortar 1 : 3 (1 cement : 3 course sand) and attached.
jointed with gray cement slurry including rubbing and polishing etc. complete
It. Applicable specification
Description of Item
49 Providing 20 mm thick double coat mala cement plaster on interior brick/ concrete As per Separate Sheet
work for plastering comprising of base coat of 12 mm thick cement plaster in attached.
cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top
coat of cement mortar 1:2 ( 1 Cement : 2 coarse sand) finished with trovel
including scaffolding curing & Providing 10 mm x 10 mm Groove at junction of
Structural member etc. complete.
50 Providing 10 mm thick cement plaster in single coat on fair side Brick/Concrete As per Separate Sheet
walls for interior plastering on ceiling and soffits of stair upto floor two level finished attached.
even and smooth and finishishing with floating coat of neat cement slurry &
Providing 10 mm x 10 mm Groove at junction of Structural member (1) Cement
Mortar 1:3 (1 Cement : 3 sand)
51 Providing 10 mm thick cement plaster in single coat on brick/concrete walls for As per Separate Sheet
interior plastering upto floor two level and finished even and smooth in (i) Cement attached.
mortar 1:3 (1-cement : 3 sand) finishing with a floating coat of neat cement slurry
including 10mm x 10mm groove at junction of structural member for First floor.
52 Providing 10 mm thick cement plaster in single coat on fair side Brick/Concrete As per Separate Sheet
walls for interior plastering on ceiling and soffits of stair upto floor two level finished attached.
even and smooth and finishishing with floating coat of neat cement slurry.(1)
Cement Mortar 1:3 (1 Cement : 3 sand)
53 20 mm thick Sand faced cement plaster on wall upto height 10 mts.above ground As per Separate Sheet
level consisting of 12 mm thick backing coat of C.M 1:3 (1 cement : 3 sand )and 8 attached.
mm thick finishing coat of C.M 1 : 1(1 cement : 1 Sand) etc. complete.
54 Wall painting (three coats) with Plastic emulsion paint of approved brands like As per Separate Sheet
Apex or equivalante and manufacture on undecorated wall surfaces to give an attached.
even shade including thorougnly brushinf the surface free from mortar droppings
and other foreign matter and sand papered smooth.
55 Finishing wall with water proofing cement paint of approved brand and As per Separate Sheet
manufacturand of of required shade on wall surface (two coats) to give an even attached.
shade after throughly brshuing the surface to remove all dirt and remains of loose
powdered materials.
56 Construction of B. B. masonary paniyara 23 cm x 75 cm walls and 15 cm x 15 cm As per Separate Sheet
curbing including fixing precast R. C. C. marble mosaic (Tarrazo) slab of 75 mm attached.
thickness on top and smooth finishing in cement plaster in C. M. 1:3 curing etc.
comp. Including drainage out waste water arrangements.
57 Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- As per Separate Sheet
40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / attached.
FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on
the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and
fixing the same with adhesive solvent, including cost of all materials.
58 Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- As per Separate Sheet
40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / attached.
FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on
the wall with the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and joints and
fixing the same with adhesive solvent, including cost of all materials.
59 Providing and fixing gun metal check or non return full way wheel valve.(E) 40 mm As per Separate Sheet
60 Providing and fixing gun metal check or non return full way wheel valve.(C) 25 mm As per Separate Sheet
61 Providing and fixing gun metal check or non return full way wheel valve.(A) 15 mm As per Separate Sheet
62 Providing & fixing Chromium plated brass half turn flush cock of approved quality As per Separate Sheet
including fixing in pipe line etc. complete.(ii) 25 mm dia. attached.
It. Applicable specification
Description of Item
63 Providing and fixing 600 mm x 450 mm. bevelled edge Mirror or superior glass As per Separate Sheet
mounted on 6 mm. thick A. C. sheet or plywood sheet and fixing to wooden plugs attached.
with C. P. Brass screws and washers.
64 Providing and fixing C.P.Brass Towel rail complete with C. P. Brass brackets fixed As per Separate Sheet
to wooden plugs with C. P. brass screw..(b) 600 mm x 20 mm size attached.
65 Providing and fixing Brass screws down Bib tap chromium plated of 15 mm dia. As per Separate Sheet
66 Providing and fixing water closet squatting pan (Indian type W.C.Pan) size 580 As per Separate Sheet
mm. vitereous china long pattern white colour 100 mm. size P or S trap with attached.
jointing the trap with the pan & soil pipe in C. M. 1:1 and fixing a pair of footrest of
size 250 mm. x 130 mm. x 30 mm., in C. M. 1:3 fixing and G. I. Inlet connentions
for flush pipe with W.C.PAN etc. comp.
67 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter As per Separate Sheet
with jali of the following nominal diameter of self cleansing design with C.I scread attached.
down or hinged grating including the cost of cutting and making good the walls.
68 Providing and fixing S.W Gully trap with C.I grating brick masonary chamber and As per Separate Sheet
water tight C.I.cover with frame of 300 mm x 300 mm size (inside) with standard attached.
weight. (i)Square mouth traps.(B) 150 mm x 100 mm size -P or R type.
69 Providing and fixing cast iron spigot and socket soil waste and ventilating pipes of As per Separate Sheet
the following nominal size.(C) 100 mm dia. attached.
70 Providing and laying (to level or slopes) and joining with stiff muxtures of cement As per Separate Sheet
mortar in proportion 1:1 salt glazed stone ware pipe incl.testing of pipes and joints attached.
etc. comp.(A) 100 mm dia
71 Providing and laying (to level or slopes) and joining with stiff muxtures of cement As per Separate Sheet
mortar in proportion 1:1 salt glazed stone ware pipe incl.testing of pipes and joints attached.
etc.comp. (B) 150 mm dia
72 Providing and fixing on wall face C.I. rain water pipe including jointing with spun As per Separate Sheet
yarn soaked in bitumen and cement 1:2 (1-cement : 2-coarse sand complete. (A) attached.
73 Constructing brick masonary chamber for underground C. I. Inspection chamber As per Separate Sheet
and bends with bricks having crushing strength not less than 35kg./sq. cm. In C. attached.
M. 1:5 C.I. Cover with frame (lightn duty) 455 x 610 mm internal dimensions. Total
wt. of cover with frame to be not less than 38kg. (weight of cover 23 kg. & wt. of
frame 15kg.) R. C. C. top slab with 1:2:4 (1 cement :2 coarse sand :4 graded stone
agg. 20 mm. nominal size) foundation concrete 1:5:10. Inside plaster 15 mm thick
with C. M. 1:3 finished smooth with a floating coat of neat cement on wall & bed
concrete etc. comp. (i) inside dimensions 455 x 610 mm. x 450 mm. deep for
single pipe line.
74 Supplying and fixing PVC water tank of ISI make including delivery at site, supply As per Separate Sheet
and fixing of inlet, outlet, air vent overflow, Ball cock, drainage sleeves of the attached.
specified size, with necessary neo-prene gasket / packing / washers, GI washer &
check nuts etc. complete as directed on terrsce, loft in bathrooms etc in any
height. The rate shall include for fixing additional accessories supplied by the
supplier accessories.
75 Providing and fixing wash basin with single hole for pillars tap with C.I. or M. S. As per Separate Sheet
brackets painted white incl. cutting holes and making good the same including attached.
fixing M. I., fisher union of 40 mm. dia.,C. P. Brass waste of 40 mm. dia,15 dia
pillar tap and brass screw down stop tap of 15 mm dia and etc. complete.(A)
Vitreous china (ii) flat back wash basin 550 mm x 400 mm size in white colour
76 Providing and fixing urinal of approved quality connecting the urinal with waste As per Separate Sheet
pipe trap etc. complete. (A) White eathern ware flat back or corner type Size:- 430 attached.
It. Applicable specification
Description of Item
77 Providing and fixing wash down water closet (european type,W.C.Pan with integral As per Separate Sheet
`P' or `S' trap including jointing the trap with soil pipe in cement mortar 1:1 (1 attached.
cement : 1 fine sand)(seat and cover to be measured and paid seperately) with
Black plastic seat and cover for wash down water closet with C.P.brass hinges and
rubber buffers.
78 Providing cement VATA (10 cmx10 cm size)quartar round in cement mortar 1:1 As per Separate Sheet
including neat cement finishing watering etc.complete attached.
79 Providing and fixing 12.5 Liters low level flushing cistern with a pair of C.I.or Mild As per Separate Sheet
brackets,complete with fittings such as lead value syphon,15 mm.nominal size attached.
brass ball valve-less with polythene float,c.p.Brass handle unions and couplings
for connections with inlet,outlet and over flow pipes,40 mm dia.porcelain
enamelled flush bend including cutting holes in walls and making the flush bend
with cistern and closet (over flow pipe te be measured and paid for seperately) (A)
Vitreous china (i) In white colour
80 Providing and laying cement concrete flooring 1:2:4(1 cement : 2 coarse sand : 4 As per Separate Sheet
graded stone aggregate 20 mm nominal size) laid in one layer finished with a attached.
floating coat of neat cement (B) 50 mm thick.
81 Providing and laying both side polished Kotah stone for shelves (A) 25 mm thick As per Separate Sheet
82 Providing and laying both side polished Kotah stone for shelves (B) 30 mm thick. As per Separate Sheet
83 Providing upto floor two level precast cement concrete jali or grill 1:2:4 (1 cement As per Separate Sheet
:2 coarse sand : 4 graded stone aggregate 6 mm nominal size) reinforced with 1.6 attached.
mm dia mild steel wire including roughening, cleaning, fixing and finishing in
cement mortar 1:3 and curing complete.(a) 50 mm thick
84 Carrying out plinth treatment to post constrution/existing structrue by spraying As per Separate Sheet
chemical solution for termite control treatment including labour and material attached.
consistent with I.S.I specification.
85 Providing and laying broken chine mosaic flooring for terrace using 12 mm As per Separate Sheet
to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain attached.
or slope and to be tempered to bring mortar creme out upto surface using
white cement including rounding off junctions and extending them upto 15 cm
along the wall,clearing with water and oxalic acid etc. as directed.
86 Providing and Constructing a junction Chamber of size 0.35 x 0.35 x 0.60 mt, As per Separate Sheet
including connecting rainwater pipes as per detail Drawing or as directed by attached.
engineer in charge.
87 Providing and laying in ground 100 mm Diameter, P.V.C. Rain water pipe with As per Separate Sheet
necessary fittings connection as per detail drawing or as directed by engineer in attached.
88 Providing and laying in ground 150 mm Diameter,P.V.C. Rain water pipe with As per Separate Sheet
necessary fittings connection as per detail drawing as directed by engineer in attached.
89 Providing & Constructing filter Chamber of size 2.06 x 1.21 x 1.20 mt. including As per Separate Sheet
connecting rain water pipes as per detail drawing or as directed by engineer attached.
90 Constructing Percolation Sockwell of 2.54 mt internal clear diameter and 5.00 Mt As per Separate Sheet
depth including brick masonary in C.M 1:6.,R.C.C. Top slab of 10 cm thick.filling attached.
witth gravel etc.complete as per detail drawing or as directed by engineer in
91 Providing and filling in foundation with ordinary Cement concrete M-100 mix and As per Separate Sheet
providing necessary vertical pin headers including formwork, vibrating, ramming attached.
and curing complete.
It. Applicable specification
Description of Item
92 Providing and laying in position Ready Mixed M-250 grade concrete for reinforced As per Separate Sheet
cement conctere work , using cement content as per approved Design Mix attached.
manufactured in fully automatic batching plant and transported to site of work in
transit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete
work including pumping of R.M.C. from transit mixer to site of laying, excluding the
cost of centering shuttering finishing and reinforcement including cost of
admixtures in recommended proportions as per IS: 9103 to accelerate/ retard
setting of concrete, improve workability without impairing strength and durability as
per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as
per latest IS 456 shall be maintained) (Cement level 450 kg )
93 Providing Trimix Machine for levelling smooth, finishing including channel fixing As per Separate Sheet
electric supply etc and dewatering of excess water through vaccum pump attached.
including transporting for machine including expansion joints filling asphalt filler
etc. complete as directed.
94 Providing and laying compacted WBM of Grading-II MCBT metal of size 45 mm to As per Separate Sheet
63 mm in required layers including using 13% stone screening 13.2mm size and attached.
8% stone dust as filler including spreading watering & consolidation by vibratory
roller etc. comp.
95 Providing and laying Cement Concrete 1 : 3 : 6 ( 1 Cement : 3 Coarse Sand : 6 As per Separate Sheet
Crushed stone aggregates 20 mm nominal size ) and curing complete including attached.
cost of form work in ( a ) Wall Caps / Copings)
96 Providing and fixing pre-cast Rubber Dye inter locking concrete block 60mm thick As per Separate Sheet
with grade of concrete M300 pnumatic compressed by mechanically pressed and attached.
as per approved design including 75mm sand layer for levelling and filling the joint
with sand in proper line and level etc. completed
97 Providing and fixing pre-cast concrete kerb stone of gray cement based concrete As per Separate Sheet
block 30cm length, 30cm height and 15 cm thick of M 250 grade concret as per attached.
approved design and including excavation for fixing in proper line and level, filling
the joint with C:M 1:3 (1 Cement : 3 fine sand) etc complete
98 Providing & fixing 2 mm thick UPVC shade with necessary MS Hollow section As per Separate Sheet
frame work with necessary fastening and fittings etc. complete with two coats of attached.
automotive paint.
99 Drilling of 215mm dia. Bore in over burden strata (0-30) including lowering and As per Separate Sheet
fixing of 175 mm nominal dia UPVC pipe upto required depth and further drilling of attached.
165mm dia bore hole in rocky strata by DTH rig.
100 Providing & fixing bore plug Suitable for 175mm UPVC Pipe having 100 mm As per Separate Sheet
Height made from 5 mm thick M.S. plate (For top also) with 3 holes at equal attached.
distance on circumference for nut – bolts type, locking arrangement with nuts –
bolts & lock nuts of std. make complete.
101 Providing and supplying & delivery of ISI marked (IS 12818 with latest As per Separate Sheet
amendment) 175.00 mm nominal dia " CS " Type. attached.
102 Water sample analysis charges. As per Separate Sheet
103 Geohydrological ground water investigations.(With vehicle charges) i) 100mm/ As per Separate Sheet
165mm / 200mm dia DTH Bore. attached.
104 Photocopy of bore with bore plug showing latitude –longitude and Photocopy of As per Separate Sheet
pump installation showing latitude –longitude in Post card size. attached.
105 Providing Single phase Borewell sub pump motor set MOC: Casing: CI-FG260, As per Separate Sheet
Impeller : Bronze & Shaft : SS:410 , Q 1.2 , 20 LPM, 110 Mtr , 1.5 HP. attached.
106 Providing PVC insulated flat submersible cable as per detailed technical As per Separate Sheet
specifications of R/C of GWSSB conforming to IS 694, IEC 60227 / attached.
60228. complete. 1 R x 3 C x 4.0 mm2.
It. Applicable specification
Description of Item
107 Providing 40 mm dia ISI marked H.D.P.E. Pipes (IS:4984/1985 with latest As per Separate Sheet
amendment) having material Grade PE-80 in approximate 100 mtr. Coil length or attached.
as per GWSSB requirement with SS-316 Nipple at both end having 11 TPI
threading as per specification, press fitted and bolted having nominal diameter as
under as per detailed Technical Specification. Rates are based on IOCL Resin A
Grade 45 GP 004DP44 as on dated 01.12.2017 (Without GST) Rs. 90284/-
providing Rates are Exclusive of GST.
108 Lowering of Single Phase Submersible Pump set complete with required length of As per Separate Sheet
HDPE pipe cable in borewell and fitting of control panel board including wiring attached.
work and satisfactory testing as per instruction of Engineer in charge at different
villages of including carting loading / unloading of materail to site for 90-120 mtr
109 Providing and fixing Clamp made from M.S. plate with 3 holes on either side with As per Separate Sheet
nuts & bolts of Std. Make and suitable size. 450 mm X 65 mm X 10 mm flat attached.
suitable upto 50 mm dia.Pipe.
110 providing and fixing 175 mm X 40 mm Bore cap in 2 halves having 40 mm hole. As per Separate Sheet
111 Providing 15 mm thick cement plaster in single coat on fair side brick/ concrete As per Separate Sheet
walls for interior plastering and finished even and smooth in cement mortar 1:4 (1 attached.
cement : 4 sand) with floating cost of neat of cement slurry [G.F)
112 Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR As per Separate Sheet
13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of attached.
following dia. Noral bore tube fitting and clamps including making good the wall,
ceiling and floor etc. complete.(A) 40 mm
113 Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR As per Separate Sheet
13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of attached.
following dia. Noral bore tube fitting and clamps including making good the wall,
ceiling and floor etc. complete.(C) 25 mm
114 Provoding & Fixing C.I. Manhole cover 0.60 M x 0.45M size having weight not less As per Separate Sheet
than 35kg. attached.
115 Providing and fixing non–asbestos cellulose cement board of SHERA FLEXY As per Separate Sheet
BOARD in False Ceiling celluloid make to the Alluminium tabular / rolled section as attached.
framing of Cladding on Ceiling, 6mm thick of approved make and size preferably
1200 mm in width fixed with S.S. screw etc. complete & work shall be done as per
drawing or directed by Engineer in charge.
116 Providing & fixing Wooden Office Table having a 0.76 m height & 1.52 m in length As per Separate Sheet
x 0.91 width using 19 mm thick plywood & 25mm & 50mm x 15mm Teakwood attached.
patti, formica handle, fastening & fixture including cost of all material & labours,
inside one priming coat & two coat of oil painting etc. complete as per drawing &
as per instruction of Engineer in charge.
117 Providing & fixing Wooden as Computer (Modular Type) Table size : 1.20 length x As per Separate Sheet
0.70 width x 1.22 height with box size 0.45 x 0.53 x 0.70 height 3 drawers and Key attached.
board try with using 18 mm W.P. ply wood, 6mm W.P. Ply wood, 12 mm W.P.
plywood, Laminate Sheet Teak wood hardware lumpsum Two Glass, Key board
Try labour charges, CPU Trolley polish work as directed.
118 Providing & fixing Wooden Cub board for file storage 0.762 height & 0.40 m in As per Separate Sheet
width using 19 mm thick Water proof plywood & 25mm x 12 Teak wood patti, attached.
50mm x 12mm Teak wood patti, sunmaika ply, magnet, stopper, Handle fastening
& fixture including cost of all material & labours, one priming coat & two coats of oil
painting etc. completed as per detail drawing & as directed by Engineer in charge.
119 Providing & fixing Wooden three seated sofa with using Indian Teak wood size in As per Separate Sheet
frame and support and 19 mm thick W.P. plywood in box of the sofa with 100 mm attached.
thick high density "U" foam in seat and 50mm thick high density "U" foam in back
portion with imported polyteel recron covering on back portion with textured
tapestry black leather covering and S.S. legs with necessary fixtures and fastening
etc. complete or as directed by the Engineer in charge.
It. Applicable specification
Description of Item
120 Providing & fixing files Storage Rack made out by M.S. angle slotted 40 x 40 mm As per Separate Sheet
weight-2.5 kg per pcs with partition / shelves M.S. sheet with 7 shelves weight 3 kg attached.
each and depth 380mm including labour, material as directed by Engineer in
charge etc. complete.
121 Providing & supplying Revolving E Buzz Mid back chair permanent contact single As per Separate Sheet
position looking mechanism. 5-prong low rise PP base fitted with twin wheel nylon attached.
castors. Elegant fixed PP armrest. Premium pneumatic gas lift. Standard fabric
upholstery. BB-EP-1 CT.
122 Providing & supplying Visitor Chair E-PRO centiliver BB-EP1 - CT. As per Separate Sheet
123 Providing & Supplying PRO-active Back Chair : 1) Single - Position Locking As per Separate Sheet
Synchro Tilt Mechanism. 2) 5-prong Nylon Highrise bas heavy duty twin wheeled attached.
nylon castors. 3) Elegant Height Adj. PU padded armrest. 4) Class IV gas lift as
per DIN standards. 5) Elegant leather upholstery.BB-PA II
124 Providing & supplying revolving vecta high back chair (BB-VC-02-B) single position As per Separate Sheet
locking synchrotilt mechanisum with "return-prevention" facility with heavy duty attached.
twin wheeled castors & elegant fabric etc.
125 Providing Curtain of vertical blinds with runners blind fabric, roller thread, manual As per Separate Sheet
powder coated channel with necessary fittings, fixtures & fastening for moving of attached.
blinds etc. completed as directed by Engineer in charge.
126 Providing and fixing coffee table with necessary wooden supports and framing of As per Separate Sheet
18mm in century make ply and century make formica / veneer laminated in attached.
combination make 8 mm glass and with necessary fixtures and fastenings etc. as
directed by Engineer in-charge
127 Providing & fixing Conference Table with necessary teak wood framing and water As per Separate Sheet
proof plywood - 18 mm of century make formica / polish laminated with necessary attached.
fixtures and fastening etc. as directed by Engineer in-charge.
128 Supply & Installation of Mobile Storage system with ruling wheel & handle As per Separate Sheet
mechanism (Hydrolic system) of size 1'.18" x 0'.45" x 2'.13" made up of 70-80 attached.
microns. Loading capacity of 350 kg with 5 adjustable level made of 20 swg thick.
The rail of 30mm bright bar pressed in the proposed mobile storage system comes
with a centralized locking arrangement.
F.F. Record Room - I.
Single Face - Size - 2160 x 450 x
Supply & Installation of Mobile Storage system with ruling wheel & handle
mechanism (Hydrolic system) of size 1'.18" x 0'.90" x 2'.13" made up of 70-80
microns. Loading capacity of 350 kg with 5 adjustable level made of 20 swg thick.
The rail of 30mm bright bar pressed in the proposed mobile storage system comes
with a centralized locking arrangement.
G.F. Record Room - I.
Double Face - Size - 2160 x 900 x
129 Providing & Supplying Gang Seater (Three Seater) Made Out by SS pipe As per Separate Sheet
130 Providing & Suupying Godrej make books Storage sliding door Cub Board. Model As per Separate Sheet
No. VSDU-8 having Size-1830mm Height x 900mm Width x 450mm Depth. 04 attached.
Nos of full shelves 78-80 Microns. As per Drawing or directed by Engineer in
131 Providing and fixing in position collapsible steel shutters with vertical channels 20 x As per Separate Sheet
10 x 2mm braced with flat iron diagonals 20 x 5mm size with top and bottom rails attached.
of T-Iron 40 x 40 x 6mm with 38 mm dia. steel pulleys complete with bolts, nuts,
locking arrangement, stoppers, handles including applying a priming coat of red
132 Horizantally mounted, centrifugal type single stage fire Booster pump capable of As per Separate Sheet
delivering 5 HP against total head of 45 mtrs. Along with necessaty fittings, Squrrel attached.
cage induction toror, enclosed fan cooling typer. Motor & Pump assembly will be
erected on common base frame (MS) fitted By proper nut bolts.(MR)
133 Control pannel for pumps (MR) SITC of Contol panel for fabricated out of 14 SEG As per Separate Sheet
CRCA sheets steel, modular construction, floor mounted, front operating type, top attached.
and bottom entru for cables for Main pump-1, Jockey pump-1 Along with
necessaty cabeling for connection of both pumps (MR)
It. Applicable specification
Description of Item
134 SITC of CI body, Butterfly valve fomplete with all fittings & matching flange (PN 16) As per Separate Sheet
(MR) 100 mm dia attached.
135 SITC of CI body, Butterfly valve fomplete with all fittings & matching flange (PN 16) As per Separate Sheet
(MR) 80 mm dia attached.
136 SITC of CIDF Non return valve, Gun metal internals, Rubber sealed conforming to As per Separate Sheet
IS specification PN 1.6 rating with bolt, nut and washer & Gasket - duel gate type attached.
(MR) 100 mm dia
137 SITC of 100 mm dial size pressure gauges with all accessories like isolation valve, As per Separate Sheet
bushets. (Glycerine filled) (MR) attached.
138 SITC of Pressure switches for auto operation of pumps (MR) As per Separate Sheet
139 SITC of Type - B G.I pipe line as per relevant IS along with fittings like sockets, As per Separate Sheet
bends, elbows, tees, plugs, nipples, flanges, reducers etc for wcternal yard attached.
network & riser (MR) 100 mm dia
140 SITC of Type - B G.I pipe line as per relevant IS along with fittings like sockets, As per Separate Sheet
bends, elbows, tees, plugs, nipples, flanges, reducers etc for wcternal yard attached.
network & riser (MR) 80 mm dia
141 SITC of First Aid fire hose reel, having 30 mtr hose with drum and shut off nozzle As per Separate Sheet
and all accessories as per the relavent standard (MR) attached.
142 SITC of Air release Valve with Isolation Valve (MR) As per Separate Sheet
143 SITC of 2 way fire brigade inlet with CI body and GM coupling (MR) As per Separate Sheet
144 SITC of MS steel for supports of fire hydrant network going along with the MS As per Separate Sheet
Structure from the wall to wall support (MR) attached.
145 Co2 Type fire extinguisher as per new IS15683 - capacity 4.5 kg (MR) As per Separate Sheet
146 ABC Type fire As per Separate Sheet
extingusher as per new IS 15683 capacity 6 kg (MR) attached.
147 MCP As per Separate Sheet
148 HOOTER As per Separate Sheet
149 FIRE ALARM PANEL As per Separate Sheet
150 2 CORE CABLE As per Separate Sheet
151 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) As per Electrical Specification
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper Booklet attached.
wires up to 10 mtr length , in below type of pipe erected with 6A Modular type
switch / bell push & accessories and earth continuity of following type, erected on
PVC / Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (f)
with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete. Cat-III
152 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are As per Electrical Specification
of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to Booklet attached.
10 mtr length, in below type of pipe erected with 6A Modular type switch and hum
free EME step type electronic fan regulator mounted and accessories with earth
continuity of following type erected on PVC / Metallic/Wooden box, single mounting
base frame covered with textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as
directed. (f) with medium class Rigid PVC pipe and accessories erected concealed
in wall/ ceiling complete, Cat-III
It. Applicable specification
Description of Item
153 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of As per Electrical Specification
ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 Booklet attached.
mtr length, in below type of pipe erected complete with Modular type switch &
pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front
plate modules erected on / in wall / ceiling as per pipe erected with following type
of accessories. [II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire
from mcb db board. (f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete, Cat-III
154 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of As per Electrical Specification
ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 Booklet attached.
mtr length, in below type of pipe erected complete with Modular type switch &
pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front
plate modules erected on / in wall / ceiling as per pipe erected with following type
of accessories. [I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from
nearby switchboard/mcb db board, (f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete
155 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket As per Electrical Specification
erected on PVC / Metallic/Wooden box, single mounting base frame covered with Booklet attached.
textured / metallic/white front plate modules erected on / in wall / ceiling with
following type accessories, Cat-III
156 Providing following type of Modular Type Accessories mounted with PVC/ As per Electrical Specification
metallic/Wooden box, single mounting base frame covered with textured / Booklet attached.
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge. (14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double
Pole Modular MCB Switch, Cat-III
157 Providing following type of Modular Type Accessories mounted with PVC/ As per Electrical Specification
metallic/Wooden box, single mounting base frame covered with textured / Booklet attached.
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge.(10) 6/16Amp. Universal socket, Cat-III
158 Providing following type of Modular Type Accessories mounted with PVC/ As per Electrical Specification
metallic/Wooden box, single mounting base frame covered with textured / Booklet attached.
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge.(3) Two Pin/RJ-11 Telephone Socket, [A]
For One Gang, Cat-III
159 Providing following type of Modular Type Accessories mounted with PVC/ As per Electrical Specification
metallic/Wooden box, single mounting base frame covered with textured / Booklet attached.
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge.(8) Computer RJ-45 socket, Cat-III
160 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked As per Electrical Specification
stranded Copper conductor wire in following type of pipe to be erected concealed Booklet attached.
in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of following size, (A) with medium
class Rigid PVC pipe and accessories, (b) 2 wire 2.5 sq. mm
161 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked As per Electrical Specification
stranded Copper conductor wire in following type of pipe to be erected in / on wall / Booklet attached.
ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size, (A) with medium class Rigid PVC
pipe and accessories, (h) 4 wire 6 sq. mm
162 Providing & erecting Switch board for Computer or electric apparatus consisting As per Electrical Specification
of following modular type accessories mounted with PVC / Metallic Booklet attached.
concealed/open box with single mounting base frame covered with
textured/metallic /white front plate,modules erected with necessary connections as
directed, 1 no. 6A/16A universal plug-switch combined. 3 nos. 6A Switch, 3 nos.
6A 5 pin Plug, For Modular Type Accessories, Cat-III
It. Applicable specification
Description of Item
163 Call bell / Buzzer,250 volts, complete erected. As per Electrical Specification
Booklet attached.
164 Call bell gong type suitable for 230 volts, 50 c/s. AC supply complete Erected As per Electrical Specification
Booklet attached.
165 Decorative call bell Ting-tong box type 250 volts complete erected As per Electrical Specification
Booklet attached.
166 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 As per Electrical Specification
Watt assembled on single MCPCB, with housing used as a heat sink shall be Booklet attached.
made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more than 0.95, THD < 15%,CCT 3000 K
to 6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 % (fitting
required LM-79 & LM-80 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Tube Light with integral driver.
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Ca-III
167 Supplying and erecting led lamps with following wattage capacity of 220 to 240 As per Electrical Specification
voltage, minimum 15000 burning hours life, 500 V in built-surge protection, Booklet attached.
Polycarbonate diffuser, mounting suitable for E14 / E27 / B22 lamp holders, pf >=
0.5, (A) LED Lamps integral type, with PC diffuser suitable LAMP holder (ii)
watts and above, Cat-III
168 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 As per Electrical Specification
Watt assembled on single MCPCB, with housing used as a heat sink shall be Booklet attached.
made of thick sheet Steel conforming to IS: 513/ CRCA/ aluminium pressure die
cast powder coated and high U.V. & corrosion resistance with diffuser housed in
aluminium casted body with company mark/ name 160V to 270V, Power Factor
more than 0.95, THD < 15 %, CCT 3000 K to 6500K, Luminaire efficacy>
lumens/ watt , LED driver efficiency > 85 % (fitting required LM-79 & LM-80
Certificates) (NOTE: Below description have shown ranges of Wattage capacity of
LED fittings. The Engineer incharge may select any wattage capacity between the
ranges shown.) (A) Square/ Circular shaped Surface/Recessed Mount Downlight
with provision for spring loaded mounting clips complete.IP20, (C) 20 watts, Surge-
169 Supplying and erecting LED street light / Flood light fittings with High power White As per Electrical Specification
LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more Booklet attached.
than 130 lm/w and corrosion free High pressure die cast aluminum housing with
smooth finish powder coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %,
CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt
. LED driver efficiency > 85 %.(fittings required LM-79 & LM-80 certificates),
(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the
ranges shown.) (A) Street Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage protection. (ii) 60 Watts and
It. Applicable specification
Description of Item
170 Supplying and erecting LED street light / Flood light fittings with High power White As per Electrical Specification
LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more Booklet attached.
than 130 lm/w and corrosion free High pressure die cast aluminum housing with
smooth finish powder coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %,
CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt
. LED driver efficiency > 85 %.(fittings required LM-79 & LM-80 certificates),
(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the
ranges shown.)(C) Post Top Lantern LED fitting comprises of Copper dust finish
cast aluminum spigot and spun aluminum canopy fixed with opal polycarbonate,
pipe arrangement for vertical mounting driver and accessories wired upto terminal
block.IP 65, (ii) 40W, Cat-III
171 Providing and erecting Approved make Four pole moulded case circuit breaker As per Electrical Specification
having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to Booklet attached.
25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C.
supply 50 c/s. with all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing. ICS=100% of ICU only, Cat III , Cat III
172 providing and erecting Approved make Four pole moulded case circuit breaker As per Electrical Specification
having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to Booklet attached.
25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C.
supply 50 c/s. with all internal connections, spreader tinned copper & complete
erected With 16 G.M.S. housing. ICS=100% of ICU only, Cat III , Cat III
173 Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper As per Electrical Specification
Busbars with four equal Nos. of electrolyte bus having current density not more Booklet attached.
than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with
colour insulating tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable socket to each
bar, erected in existing cubical panel with necessary connections. (A) Suitable for
100 Amp. Capacity
174 Providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and As per Electrical Specification
having breaking capacity 10 KA to be erected in existing box. confirming to IS Booklet attached.
8828/1996 with ISI Mark. Ca-III
175 providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to As per Electrical Specification
operate on 240 V A.C. system and having breaking capacity 10 KA to be erected Booklet attached.
in existing box. confirming to IS 8828/1996 with ISI Mark, Cat-III
176 Providing & erecting 240 V MCB double pole switch for motor & inductive load (C As per Electrical Specification
Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box Booklet attached.
having following capacity, (B) 40 Amp., Cat-III
177 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) As per Electrical Specification
having 10KA breaking capacity & confirms to IS :8828 in existing box having Booklet attached.
following capacity, (b)40 Amp. Cat-III
178 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) As per Electrical Specification
having 10KA breaking capacity & confirms to IS :8828 in existing box having Booklet attached.
following capacity,(a) 6 to 32 Amp.
179 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / As per Electrical Specification
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms Booklet attached.
to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of
MCBs.(The DBs should be used of same company of MCB to be used) suitable
for, (A) single phase incoming and horizontal single phase outgoing, (a) single
door (IP-30), (i)4 way
It. Applicable specification
Description of Item
180 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / As per Electrical Specification
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms Booklet attached.
to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of
MCBs.(The DBs should be used of same company of MCB to be used) suitable
for,(B) three phase incoming and single phase horizontal type outgoing Per phase
isolation type (PPI), (b) sheet steel double door, (ii) 6 way
181 Providing and erecting Approved make RCCBs conforming to IS: 12640 and As per Electrical Specification
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and Booklet attached.
suitable for operation on single phase 240 V,50Hz. having characteristic of quick
action & tripping with all advance feature & do not incorporate any electronic
component. for following Max. rating erected as directed (iI) 40 Amps. DP Cat-III
182 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia. As per Electrical Specification
galvanised iron pipe with coupling and buch burried in specially prepared earth pit Booklet attached.
complete with necessary 8 SWG earth wire with using salt and charcoal/coke as
required for pipe type earthing.
183 Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade As per Electrical Specification
ISI marked copper wires of following size to be erected as directed. e) 1.50 Sq.mm Booklet attached.
3 core round PVC sheathed
184 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid As per Electrical Specification
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in Booklet attached.
existing trench / pipe of following size of cables, (a) 4 core 6 Sq. mm
185 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid As per Electrical Specification
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in Booklet attached.
existing trench / pipe of following size of cables,(C) 4 core 10 Sq. mm
186 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand As per Electrical Specification
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in Booklet attached.
existing trench / pipe of following size of cables3 1/2 core 50 Sq. mm ( 25 Sq.
187 Supplying & erecting earth pit of minimum bore dia.150mm size approved make As per Electrical Specification
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made Booklet attached.
of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-
200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with constant ohmic value
surrounded by highly conductive compound with high charge dissipation suitable
for following type of applications with chamber and heavy duty cover.(approved
make OEM has to submit test certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:- 0.2 Ὠ/ meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted. (a) For Electrical
Installation up to 440V in normal soil, Length of pipe - 1 Mtr, Back filling compound -
1 Nos Bag of 15 Kg.
188 Making trench in soft soil of suitable width of 90 cm deep for laying cable or As per Electrical Specification
locating the fault all over the run and back filling the same and making the surface Booklet attached.
as normal ground.
189 Providing & laying approved make Double walled corrugated pipes (DWC) of As per Electrical Specification
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of Booklet attached.
same material at required depth in existing trench for laying of cable. below
ground / road surface for enclosing cable. (A) 50 mm outer dia
It. Applicable specification
Description of Item
190 Providing & erecting weather proof, dust & vermin proof, floor mounted front As per Electrical Specification
operated indoor type cubical panel board necessary IP-42 and above protection Booklet attached.
as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet
for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with
necessary accesories , supporting angles/ flats channel including cutting,
bending, drilling, welding, riveting with internal partitions & cable alley as per
requirements & instruction of engineer-in-charge with erection of supplied switch
gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-
aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring
instruments, earth bus & earth bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with locking arrangement and rubber
gasket,heavy duty end terminal nnection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be painted with epoxy powder
coating. (The rates excludes the cost of switchgears, bus bars, inter connecting
mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall be supplied with following
approved manufacturers with following size.(A) locally fabricated panel board (i)
with 350 mm depth
191 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for As per Electrical Specification
PVC insulated armoured cable complete with out going tails, insulating tape etc for Booklet attached.
following size of cables. (a) 2 to 4 core 2.5 / 4 Sq. mm
192 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for As per Electrical Specification
PVC insulated armoured cable complete with out going tails, insulating tape etc for Booklet attached.
following size of cables (C) 2 to 4 core 10 Sq. mm
193 Providing and, fixing heavy duty flange type brass double compression type cable As per Electrical Specification
gland with rubber ring for PVC insulated armoured cable complete with out going Booklet attached.
tails, insulating tape etc for following size of cables. (B) 3½ core 50 Sq. mm
194 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of As per Electrical Specification
following size evenly crimped with high pressure tool & connected to switchgear Booklet attached.
terminals with brass/cadmium plated nut bolts in an approved manner. (D) 35/50
195 Solder less crimping type Aluminium lugs conforming to IS suitable for cable of As per Electrical Specification
following size evenly crimped with high pressure tool & connected to switchgear Booklet attached.
terminals with brass/cadmium plated nut bolts in an approved manner. (B)
196 Providing and erecting Approved make Ceiling fan with double ball bearing ISI As per Electrical Specification
mark with condenser A.C. 23OV, 50 c/s, 1200 mm. sweep complete, canopy Booklet attached.
erected on existing hook or clamp with earthing. [Make shall be approved by
Engineer in charge]
197 Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC As per Electrical Specification
bars up to 50mm length each side and pierced through a 16 Gauge M.S. box / Booklet attached.
Heavy Duty PVC box complete erected concealed in Ceiling with necessary
198 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down As per Electrical Specification
rod erected duly painted for fan complete with proper insulation without leakage Booklet attached.
199 Supplying & erecting approved make low noise decorative exhaust fan having As per Electrical Specification
square frame ABS body with inbuilt lowers & square frame. 200mm with 1350 Booklet attached.
RPM Cat.II Ca-II
It. Applicable specification
Description of Item
200 Supplying and erecting approved make Octagonal pole made from HR sheet steel. As per Electrical Specification
The pole should be made as per IS. and shall be coated with hot dip galvanizing Booklet attached.
as per IS 2629/2633/4759, suitable suspend local wind speed with integral
Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for
cable termination to be erected With Suitable foundation (Included) as per details
given by manufacturer considering site requirement. ((C) 5 Mtr. Long 70 mm Top
X 130 mm bottom dia, 3 mm thickness with 200mmX200mmX12mm base plate, 4-
M16 Bolts and 600mm long with necessary G.I. J Bolts .Approx Pole weight 46 kg
201 Supplying and erecting Street light pole bracket comprising main B Class GI pipe As per Electrical Specification
of 4.2 cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of Booklet attached.
approx. 45cms.length and suitable for 76.5mm/80mm/require size of pole top
having nuts and bolts for fixing the brackets and having spread of 0.5 mtr. Length
with 110 deg.with vertical plane and suitable welded stiffener reducer and nipple
with check nut complete painted with one coat.of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following nos of arms. [A] Single Arm
bracket 0.5 Mtr
202 Supplying & erecting approved make Digital time switch having lithium cell 6 years As per Electrical Specification
operative and operate battery backup 1 channel day clock with 14 memory Booklet attached.
programme, suitable to operate on 240V + 5%, 16A with, floating contacts
Minimum switching setup time 1 minimum & LCD display. Also comprised
permanent ON/OFF switching. Programming switches & housed in fire proof
thermoplastic enclosure & transparent cover erected as required with necessary
connection erected as directed.
203 Supplying & erecting power contactor ,AC3 duty for time switch complete erected As per Electrical Specification
as per direction Cat III [C] 4 pole 440V 16 Amp. Booklet attached.
204 Providing and erecting Inverter based approved make split air-conditioning unit As per Electrical Specification
consisting of condensing unit with variable speed fan motor, inverter type Booklet attached.
hermetically sealed rotary compressor with accessories etc. duly connected
separately erected evaporating unit and blower motor with its accessories by
means of extra supplied proper insulated copper tubing,drain PVC pipes suitable
for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote
Control & MS Stand) with necessary core cutting. (1)For ISEER Range
(KWH/KWH)(3.1 to 3.99) (C) for 1.7 to 2 ton capacity - Premium Cat.
205 Supplying and erecting insulated pair of soft copper tubing open or concealed As per Electrical Specification
including power and control cable,necessary PVC drain pipes for Split AC Booklet attached.
machine up to 4 TR capacity
206 Supply and Erecting of Static Stabilizer suitable for following capacity of A.C As per Electrical Specification
Machine the Stabilizer Must have Minimum Technical Specification are Input Booklet attached.
working Single Phase Voltage Range Up to 150V-280V.50Hz, Output Voltage
Range Up to 200V-240V,50Hz,Autoreset Facility,LED Display for Indicating
Voltage,Spike/Surge Protection,Time Delay Facility,Proper Wall Mount Facility with
Required Accessries & on site 3 year Replacement/Repairing Warranty.
(2) For 2 Ton Thermal Overload Protection 15 Amp.
207 Providing & erecting water cooler having storage capacity 150 Ltr. & cooling As per Electrical Specification
capacity 150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the Booklet attached.
water should drop by 15˚C within a hour, The water cooler should be comprising of
hermetically sealed compressor, fan motor, condensing unit, water tank
surrounded by evaporating, coil, thermostats, relay etc.complete with necessary
inlet & outlet connection. The body of water cooler will be made from Stainless
It. Applicable specification
Description of Item
208 Supplying & erecting reverse osmosis (RO) water purification system with M.S. As per Electrical Specification
powder coated pedestal frame, prefilter housing carbon filter suitable buster DC Booklet attached.
pump, auto low & high pressure switches with following size of LPH capacity &
erected as directed with one year comprehensive maintenance guarantee. [D]
LPH with 3 phase Raw water pump of 500LPH @ 2.5kg/cm2 - (1N0 - Kirloskar
/CRI/Lubi), Dual media filter 10"x54" - (1 No), Micron cartridge filter 20" x 2.5" (
1No), High pressure pump 500LPH @ 10kg/cm2 - (1No - Shimge /CRI /Lubi), RO
Membrane housing with RO membrane of 40*40 - (1No), RO pressure tube 4" x
1E - ( 1No), 0 - 1200LPH Rotameter -(2 Nos), with Recovery Rate 50%.
209 Supplying and erecting approved make panel mounting type Digital Voltmeter As per Electrical Specification
having 3 digits LED display, 0 to 750 AC Volts range erected on existing panel Booklet attached.
board with all connection, wiring etc .with manufacturers calibration certificate.
210 Supplying and erecting approved make panel mounting type Digital Ammeter As per Electrical Specification
having 3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps Booklet attached.
suitable to operate on 500 Volt AC , erected on existing panel board with all
connection, wiring etc. with manufacturers calibration certificate.
211 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 As per Electrical Specification
ratio 15 VA burden erected in existing CRCA box duly secured with insulating Booklet attached.
materials connected to the meter.
212 Supplying and erecting approved make suitable panel indicator lamps of LED type As per Electrical Specification
lamp, lens cover, Bakelite holder complete erected with necessary connections. Booklet attached.
213 Supplying & erecting approved make Telephone Cable electrolytic copper As per Electrical Specification
conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & Booklet attached.
sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring &
confirming to C-DOT erected in existing pipe. of following size of conductors &
nos.of pairs. With necessary connections. [A] Conductor Size 0.5 mm, (a)
Unarmoured, 2) Two Pairs
214 Supplying & erecting approved make Telephone Cable electrolytic copper As per Electrical Specification
conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & Booklet attached.
sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring &
confirming to C-DOT erected in existing pipe. of following size of conductors &
nos.of pairs. With necessary connections. [A] Conductor Size 0.5 mm, (a)
Unarmoured,5) Ten Pairs
215 Supplying & erecting approved make LAN cable of following size in existing pipe As per Electrical Specification
as per direction, [C] CAT - 6 Booklet attached.
216 Providing & erecting main Distribution (MDF) indoor type, back mounted frame as As per Electrical Specification
per DoT standard approved with krone strips, (a) Suitable for 10 pair Booklet attached.
217 Providing and erecting Small EPABX System with In Built 4 Port Voice Mail As per Electrical Specification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Booklet attached.
[B] No. Extension - 16 , No. of Junction -8 , No. of expandable ports -64
Operators Console -01 Compatible - ISDN
218 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size As per Electrical Specification
complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Booklet attached.
Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in
approved manner as directed, (a) 20 mm
It. Applicable specification
Description of Item
219 Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar As per Electrical Specification
Power Plant with Solar Panels (ALMM approved): Frame Material : Anodized Booklet attached.
Aluminum alloy Frame With Twin Wall Profile, Front Cover : High Transmission
Low-Iron Tempered Glass (AR Coated), High efficency and positive power
tolerance Pmax: 0/+5, Module Efficiency should be approx. 19.5%-22%, Normal
operating temperature 45'C, Junction Box with Waterproof IP67 & MC4
Compatible and Enclosed with Bypass diodes, 100% Electroluminescence test to
ensure error free Modules, Thep. temp. co-efficient of the PV module shall equal
or better than -0.45%/degree C. Solar PV modules of minimum fill factor 75% to be
used. Unit Production:- More than 4.5 Unit /kw /day (Actual)(1Year Avg) With
year Product warranty and 25 year Linear Power Warranty includes all mechanical
and electrical parameters of the Solar panel. Modules must be complied to the
DCR(Domestic content requirements). The Ration of AC to DC is 5:6 for the
Installation capacity which are given in AC KW. Solar Inverter: MPPT Range:
MPPT Range: 80-1000 V , Max efficiency: 97.5% - 98.9%, O/p Frequency:
50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%,
Operating Tempreture Range: -25~60°C, Integrated protection of Inverter are Anti-
islanding Protection, Input Reverse Polarity Protection, Insulation Resistor
Detection, Ground fault protection, Residual Current Monitoring Unit, Output Over
Current Protection, Output Short Circuit Protection, Output Over Voltage
Protection, PV array string fault Protection. Protection Degree: IP65, User Interface
LCD & APP, Datalogger & Communication: GPRS / Wi-Fi. Integrated, Input
Reverse Polarity Protection Integrated, Insulation Resistor Detection Integrated,
Residual Current Monitoring Unit Integrated, Output Over Current Protection
Integrated, Output Short Circuit Protection Integrated, Output Over Voltage
Protection Integrated, Protection Degree: IP65, User Interface LCD &
APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure:
The mounting (Rectangular pipe / square pipe / circular pipe) with requisite cross
bars, nuts and bolts, etc. shall be Hot deep galvanized with minimum 80micron
coating. The Rectangular / square /circular hollow pipe section used for the
structure should have a minimum thickness of 2.0 mm. other than above, the
material thickness should be minimum 2.5 mm. A certificate of a structural
engineer certifying the strength and stability of the mounting structure to withstand
the weight and wind speed of 150 km/hour throughout the life span of 25 years of
the system, shall be submitted by the vendors. Hot Dipped Galvanized steel coils.
suitable arrangement for base plate for foundation , solar panel mounting, the
structure should be suitable for carry the load of solar panel,wiring, sprinkler
system etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc.
the nut bolt used for installtion of stucture should be (SS 304) quality.The ground
clearance of the bottom most edge of solar panel shall not be less than 300 mm to
1200 mm or as per site’s technical/feasibility requirement. a. Column –The
minimum section (thickness) should be 60MM*40MM b. Rafter - The minimum
section (thickness) should be 60MM*40MM c. Purlin - The minimum section
(thickness) should be 40MM * 40MM Balane of System with necessary Swichgears
(Suitabel size and protection of ACDB & DCDB), inter connecting wiring, earthing
system as per the CEIG drawing approval, lightining arrester system as per the
CEIG drawing approval, all liasoning work with various gov. dipartment like state
nodal agency,DISCOM & CEIG is included in agency scope (Excluding GEDA
Application fees, Solar connectivity Charges, Meter connectivity Charges, Meter
testing Charges.) (B) Grid Tied Solar Power System: 7 - 10 kW (3 - phase)
Deputy Executive Engineer, Executive Engineer
Panchayat (R & B) Sub Division Panchayat (R & B) Division
Chhotaudepur Chhotaudepur
Name of Work :- Construction of Taluka Panchayat office building at Kawant Ta. Dist : Chhotaudepur
Under CDP-3 (2025-26)
1 All works shall be carried out as per latest MORTH Specification Booklet and other specification of
Division as directed.
2 All Rates quoted include clearance of site (prior commencement of work and at its close) in all
respects and hold good for work under all conditions, site moisture, weather etc.
3 The contractor shall exhibit a board as per Government Circular No. Vernacular TNC/1090/24/S
dated 05.03.2011 with details specifications and details of works and amount involved at site at his
own cost as directed by Engineer-in-charge.
4 Testing of material shall be done as per statement attached with specification. The material should
be tested in GERI or Private laboratory approved by Govt. of Gujarat. Bill for testing charges
should be paid by Executive Engineer and computed after deducting the cost of materials to be
supplied by the Govt. and shall be recovered from the contractor's running bill as per Govt., R&B
Department No. TNC-1085/(4)/C dtd 20-12-91.
5 1.00 % of Construction cost shall be deducted form Bill. Amount of Contract as per the Building
and other Construction worker's welfare cess Act - 1996 (Labour & Employment Department Letter
No. CWA - 2004 - 1831 - M (3). Dt. 9-12-05, Notification of Labour & Employment Department
Dtd. 03-01-05 and Labour & Employment Department letter No. CWA / 2004-841-M(3), Dt. 14-12-
6 In all R.C.C. items in rate analysis, standard cement consumption has been taken as per Govt. GR,
PRC-10/2017/Cement Consumption/16/C, Dtd. 11/05/2017 as stated in SOR therefore in RCC
items where there is a change as per actual mix design the cost of difference of cement consumption
shall be deducted from the rate of original item at the rate of input rate mentioned in the tender.
7 Bidders are advised to visit the site & make himself / themself aware of the scope & specification
of the work to be done & of conditions and other factors bearing on the execution of the work
before on line submission of his / their bids. Once the bid is finalized, under no circumstances
arguments for crust deficiency / additional / altered works will be heard until & unless Engineer in
charge deem so. Engineer in charge shall have right to reject & decision of Engineer in charge shall
be final & binding.
8 If found necessary, contractor will be intimated for negotiation. He will be intimated maximum
three times within validity period for negotiation. If contractor does not respond in time, his earnest
money will be forfeited and his tender will be rejected. Paneltative action will be taken on such
Name of Work :- Construction of Taluka Panchayat office building at Kawant Ta.
Dist : Chhotaudepur Under CDP-3 (2025-26)
Sr. Name of Type of Test To be Qty Frequency of Test No of
No. Materials Performed As per Govt. Circular Test
(For all Type of tests). Reqd.
1 M.C. Kapchi 1 Agg. Impact Value 946.71 100 Cum 1
10 to 20 mm 2 Gradation Cum 101-500 Cum
3 Flakiness Index 501-1500 Cum
4 Abrasion Test 1501-5000 Cum
5 Crushing Test 5001 to 8000 Cum
2 Murrum 1 Plasticity Limit 390.00 101-500 Cum 3
2 Liquid Limit Cum
3 Bricks 1 Dimention 234990.00 20 Bricks upto 10000 Nos
2 Efflorescence Nos. 32 Bricks upto 35000 Nos
3 Water absorption 50 Bricks upto 50000 Nos
4 Compressive Strength
4 Steel TMT Fe-500D 1 Bend Rebend 120.00 1 test per 1 1 test per
IS 1599-1960 M.T. 40 Tonne each
2 Tensille, yield elongation for each category category
3 Dimension Test
4 Ulitimate Test
5 Cement 1 Consistency 569.80 50 MT 1
2 Setting time M.T. 51 to 100 MT
3 Compressive Strength 101 to 200 MT
4 Fineness 201 to 300 MT
5 Chemical Analysis 301 to 500 MT
6 Concrete Cube Compressive Strength 1 to 5 Cum 1
(For All Grade of 6 to 15 Cum
Concrete Ordinary / 16 to 20 Cum
Controlled) 21 to 50 Cum
C.C. 1:2:4 Each 50 Cu.M
CC- M-150 90.00 part thereof
Sr. Name of Type of Test To be Qty Frequency of Test No of
No. Materials Performed As per Govt. Circular Test
(For all Type of tests). Reqd.
7 Sand 1 Silt Content 3431.67 150 to 5000 Cum 7
2 F.M Cum 5000 to 8000 Cum
8 Water 1 Chemical Analysis - 1 Test / 1 Source
9 Crushed Metal 1 Agg. Impact Value 35.09 100 Cum 1
25 to 40mm nominal 2 Gradation Cum 101-500 Cum
size 3 Flakiness Index 501-1500 Cum
4 Abrasion Test 1501-5000 Cum
5 Crushing Test
10 Aggregates ---- do -------
11 Teak wood 1 Anatomy test -
3 Moisture content test
12 Tiles 1 Dimension test
2 Transverse strength Sq.m.
3 Water Absorption
4 Abrasion test
DTP for Approval
Deputy Executive Engineer Executive Engineer
Panchayat (R & B) Sub Division Panchayat (R & B) Division
Chhotaudepur Chhotaudepur
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
91.2 SBD Const. Taluka Panchayat Office Kawant Ta..pdf
Bill of Quantities.pdf
Schedule B.pdf
91.2 Specification Taluka Panchyat Kawant.pdf
91.3 Electrical Tender General and Technical Condition SPECIFICATION.pdf
Condition for Nominated Contractor _C Ele.pdf
make list ELE.pdf
Memorandum of Understanding ELE.pdf
Scan Drawing Ta. Panchyat Kawant.pdf
SOLAR CONDITION.pdf
GR_to_be_attached_with_DTP_SBD_with_Index (1).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .