| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAccepted-AOC 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹7.3 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹7.5 Cr+₹15.8 L (2.15%)Rejected-Finance | ₹7.5 Cr+₹15.8 L (2.15%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹7.9 Cr+₹55.5 L (7.57%)Rejected-Finance | ₹7.9 Cr+₹55.5 L (7.57%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹13.1 Cr+₹5.8 Cr (78.9%)Rejected-Finance | ₹13.1 Cr+₹5.8 Cr (78.9%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | Rejected-Technical 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | - | - | Rejected-Technical Not validated due to two class below |
Tender Value
Refer Docs
EMD Value
₹7.1 L
Closing Date
26 Dec 2020, 6:00 pmClosed
CE Jodhpur Zone
HQ CE Jodhpur Zone Jodhpur
PROVISION OF SEWAGE TREATMENT PLANT AND CONNECTED WORKS AT GANDHINAGAR UNDER GE (ARMY) GANDHINAGAR (JOB NO.007/AMWP/12C/2019-20)
2020_MES_361857_2
800505/GNR/2020-21/E8
Open Tender
Civil Works
Lump-sum
1380 days
Gandhinagar
Please refer Tender documents.
10 documents required · 10 mandatory
₹3,000
GE (A) Gandhinagar
₹7.1 L
Yes
2 Feb 2021
9 Nov 2020
28 Dec 2020
9 Nov 2020
26 Dec 2020
11 Dec 2020
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 27
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 29
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 30
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 33
Lump sum price worked out by the contractor for "ROAD, PATH, & CULVERT etc." as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 35
Lump sum price worked out by the contractor for "SEWAGE NETWORK" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 36
Lump sum price worked out by the contractor for "RECYCLING OF TREATED WATER " as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No 37
Lump sum price worked out by the contractor for "FENCING AND GATE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 39
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY AND RISING MAIN-STP EM" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 41
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 46
Lump sum price worked out by the contractor for "DG SET " as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 47
Sch 'A' Sec-XII (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-II (Excavation and earthwork schedule).
INTERNAL WATER SUPPLY
S & F 15 mm Bib taps brass of long body with capstain head screwed up or down complete all as specified and directed.
S & F fancy type pillar taps, cast copper alloy with capstain heads chromium plated, screwed down high pressure with or without lettered HOT or COLD with long screwed shanks and fly nuts screweed for iron pipe and fixed complete all as specified and directed.
S & F CP brass angular stop cock suitable for 15 mm bore fitting with capstain head screwed up or down complete all as specified and directed.
S & F 8 mm dia brass, CP health faucet (Hand shower) with 1 meter long flexible tube and wall hook complete all as specified and directed .
INTERNAL ELECTRIFICATION:
Supply and fixing LED light fitting, batten type, housed in extruded from powder coated aluminium, 20 watt complete set flexible three core copper conductor cable of suitable size complete all as specified and directed.
S & F LED light fitting batten type 10 watt complete all as specified and as directed.
S & F LED oval bulk head 10 watt complete all as specified and as directed.
Supply, fixing and testing ceiling fan of 1200 mmsweep, 230 Volts, single phase, 50 Hz 3 blades, double ball bearing BLDC FAN , BE rating connection up (Dust Resistance) complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 sqmm from ceiling rose / connector, including extra GI / MS pipe down rode, as per site requirement (approximate length 01 Mtr) complete all as specified and directed
Supply, fixing and testing Metal body heavy duty Exhaust Fan 450mm sweep 230V,50 Hz with copper winding including fixing arrangement, making connection with 1.5 Sq mm copper conductor cable from exhaust fan to connector & writing MES No with black synthetic enamel paint complete all as specified and as directed.
S & F ISI marked MCB for AC applications till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed.
5 A to 32 Amps SP MCB, C- curve
32 A, SPN MCB, C- curve
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, two runs of 4.00 sqmm main cable and one runs of 4.00 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB UPVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Two runs of main cable + one runs of earth conductor and one run of UPVC conduit shall be measured as one RM.
S & F electronic ceiling fan regulator steeped type AC 230 volts complete
ROAD/PATH/CULVERT & HARDSTANDING
M&L for 150 mm thick (compacted thickness) ready mix wet mix macadam (WMM) using materials of 30 CBR, in two layers each of 75 mm thick (each layer to be rolled and consolidated seperately) confirming to the grading given in table 400-13 and physical requirements given in table 400-12 spread with mechanical means as specified, hollows made upto for true surface, spread, surface binding with and including screening and moorum, watered, consolidated and rolled with vibratory roller 8 to 12 tonne as per clause 406.3.5 of MORT&H to required gradient and camber complete all as specified and as directed.
M&L for Preparing bituminous surfaces of road and applying road marking paint 2.5mm thick centre lines ,stops lines ,dashes, arrows etc and the like not exc 15 cm wide on roads pavement with hot applied thermo plastic road marking paint of approved colour confirming to BS-3262-1989 with fully/semi automatic thermopoplastic paint applicator filled with profile shoe , glass beads dispensor, propen tank heater and profile shoe heater driven by experience operator on road surface free from all dirt,dust etc complete all as manufacturer instruction and specified.
SEWAGE NETWORK
Supply and Fixing of Dubble Wall Corrugated (DWC) HDPE pipe of Class SN8 ,Laid and jointes complete with collars of following size :-
150 MM dia pipe
200 mm dia pipe
250 mm dia pipe
300 mm doa pipe
SEWAGE MANHOLES M & L for constructin of manholes as under :- Note : (a) Quoted rate shall be inclusive for construction of all manholes upto a height of 300 mm above the ground level. (b) Depth of manhole for payment as herein under for item No 31.01 to 31.08, 33.01 to 33.03, 35 to 36 shall be measured from GL upto the top of manhole floor/invert level of sewer pipe. (c) Earthwork in excavation, returning filling, removal of surplus excavated soil and precast manhole cover with frame shall be measured and paid separately. (Refer Drg No CEJZ/WD/120/2020 Sheet 1/1).
M & L for construction of sewer, scraper manholes Type A circular type internal dia 1200 mm all as per Drg No CEJZ/WD/120/2020 Sheet 1/1 with 100mm thick PCC 1:3:6 type C2 in bedding and 200mm thick solid PCC block 1:2:4 type B1 mix walling in CM 1:4, internal and external plastering 10mm thick in CM 1:3, PCC benching and flooring in 1:2:4 mix type B1 and RCC M-20 grade coping (Manhole frame and manhole cover measured separately) including PVC encapsulated rungs etc complete all as shown in drg for fixed depth of 1.0 metre from GL
Extra over item 31.01 for extra depth of manhole Type A circular type internal dia 1200 mm beyond the fixed depth of 1.00 metre (catered for in item No 31.01 above) upto 1.5 metre built all as per Drg No CEJZ/WD/120/2020 Sheet 1/1
M & L for construction of sewer, scraper manholes Type B circular type internal dia 1500 mm all as per Drg No CEJZ/WD/120/2020 Sheet 1/1 with 150mm thick PCC 1:3:6 type C2 in bedding and 150mm thick solid RCC M-30 grade walling and flooring complete with corrosion resistant steel reinforcement Fe-500 grade, 10mm thick internal and external plastering in CM 1:3, PCC benching and flooring in 1:2:4 mix type B1 and RCC M-30 grade coping (manhole frame and manhole cover measued separately) including PVC encapsulated rungs etc complete all as shown in drgs for fixed depth of 1.5 metre from GL.
Extra over iem 31.03 for extra depth of manhole Type B circular type internal dia 1500 mm all beyond the fixed depth of 1.50 metre (catered for in item No 31.03 above) upto 3.00 metre
M & L for construction of sewer, scraper manholes Type C circular type internal dia 1500 mm all as per Drg No CEJZ/WD/120/2020 Sheet 1/1 with 150mm thick PCC1:3:6 type C2 in bedding and 150mm thick RCC M-30 grade walling and flooring complete with corrosion resistant steel reinforcement Fe-500 grade, 10mm thick internal and external plastering in CM 1:3, PCC benching and flooring in 1:2:4 mix type B1 and RCC M-30 grade coping (manhole frame and manhole cover measued separately) including PVC encapsulated rungs etc complete all as shown in drgs for fixed depth of 3.00 metre from GL.
Extra over item 31.05 for extra depth of manhole Type C circular type internal dia 1500 mm all as per Drg No CEJZ/WD/120/2020 Sheet 1/1 beyond the fixed depth of 3.00 metre (catered for in item No 31.05 above) upto 4.50 metre
M & L for construction of sewage scraper manholes Type D circular type internal dia 1500 mm all as per Drg No CEJZ/WD/120/2020 Sheet 1/1 with 150mm thick PCC 1:3:6 type C2 in bedding and 200mm thick RCC M-30 grade walling and flooring complete with corrosion resistant steel reinforcement Fe-500 grade, 10mm thick internal and external plastering in CM 1:3, PCC benching and flooring in 1:2:4 mix type B1 and RCC M-30 grade coping (manhole frame and manhole cover measued separately) including PVC encapsulated rungs etc complete all as shown in drgs for fixed depth of 4.50 metre from GL.
Extra over item 31.07 for extra depth of manhole Type D circular type internal dia 1500 mm all as per Drg No CEJZ/WD/120/2020 Sheet 1/1 beyond the fixed depth of 4.50 metre (catered for in item No 31.07 above) upto 6.00 metre
M & L for providing GI safety chain 8mm dia of length exceeding 90 cm but not exceeding 1.5 m including eye nuts washers, shackles and fixing to RCC manhole walls with through bolts complete all as specified and directed Note : Safety chain shall be installed in down stream sides of manholes for dia of pipe 600 mm and more
VERTICAL DROP MANHOLES: -M&L Providing and Constructing vertical drop arrangement of 0.6 m and more height as required including providing and jointing special such double T.Bend required stoneware pipe fixed in PCC 1:3:6 type C2 at required level as type design cutting,jointing and filleting as per specification etc complete (Refer Drg No CEJZ/WD/120/2020 Sheet 1/1) for following
(i) "B" type Manhole Avg.Depth 2.573 Mtr.
(ii) "C" type Manhole Avg.Depth 3.819 Mtr.
(iii) "D" type Manhole Avg.Depth 4.905 Mtr.
M & L for providing factory made pre-cast FRC (Fibre reinforced concrete) manhole cover and frame 900mm dia (600mm dia clear opening) HD-20 grade including provn of mild steel flat framing for edge protection and finishing etc complete all as per IS-12592 of 2002, setting in cement mortar 1:3 and haunching with cement concrete 1:2:4 type B-1 all as specified and directed
M & L for providing and constructing rectangular brick masonry chamber for house connection chamber internal size 610mm x 455mm and depth 450mm with brick masonry 230mm thick walling built in CM 1:4 including PCC 1:3:6 type C2 100mm thick bedding & benching in PCC 1:2:4 type B1 and plastering in CM 1:3 10mm thick with RCC coping and precast manhole cover and frame etc complete (Excludng excavation for house connection chamber all as per Drg No CEJZ/WD/120/2020 Sheet 1/1)
Ditto all as per above item No 35 but additional depth beyond the first 450mm upto 750mm
Drilling of horizontal boring under the road etc for watertermain/ sewermain pipeline crossing under the road including in any type of strata with required length incl.fixing of DWC pipe with pushing etc.complete various size of pipe (For Maximum of 45 mtr length) below road level complete all as specified. Note : Pipe will be measured and paid separately)
(i) 450 mm dia pipes
(ii) 600 mm dia pipes
RECYCLING NETWORK
Supply and fixing of 40mm dia ball valve (brass insert) heavy duty as per requirement on site
Supply and fix Valve ,reflux,with by-pass Arrangement ,50mm (2") dia
S&F sluice valve,150 mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.60, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
S&F sluice valve,100 mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.60, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
M&L for contruction of valve pit Brick/stone/PCC block masonary constructed of size 60cmx 60cmx 75cm (Internal dimensions) complete with mild steel sheet cover 3mm thick and angle iron frame of size 40x 40x 6mm , heavy duty fabricated hinges duly painted with two coats of synthetic enemal paint over a coat of red oxide primer and including locking arrangement and lifting handle including PCC 1:4:8 type D2 in bed concrete, brick work in CM 1:4, PCC coping 1:2:4 type B1, plastering in 1:4 cement mortar, 15mm thick complete internally and externally upto 150mm below GL, complete all as specified including excavation and earth work in any type of strata, plastering all walls surfaces internally and flush pointing to brick work externally competely all as specified and as directed.
M&L Supply, installation, testing and commissioning of 80 cum/hr @ 35 mtr head non-clog vertical submersible pumps with chrome steel impeller and cutter, non clog to pass 40mm size particle including supply, installatin of guiding rail and lifting chain, cables, earthing, testing complete for two years maintenance to pump treated water from earthen pond to 1 lakh ltr treated water tank
PUMPING STATION EM ITEMS
Supply Installtion Testing and Commissioning (SITC) of 26 Cu.m/hr. & 24 mtr head Submersible non clog sewage transfer pump for Pumping Station at Node No. 529 Note : Cost of foundation as specified by OEM included in quoted rate.
Supply, installation, testing and commissioning of Mechanical screen of 0.65 m width x 7 m height capacity with all necessary fittings for Bar screen channel
Supply, installation, testing and commissioning, Supply, install testing and commisioning of Non return valve 100 mm dia For sewage pump at pumping station
S & F sluice valve,100 mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.60, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
Supply, installation, testing and commissioning of Butterfly valve 100 mm dia for for sewage pump at pumping station.
Supply, installation, testing and commissioning of Float type Level switch (vertical) for equalization tank,chlorine contact tank,teritary treated water tank,sludge tank.
Supply, installation, testing and commissioning of 100 mm dia of 0-7 Kg/cm2 Pressure gauge for pumps,blowers etc.
Hook suspension type Heavy Duty Chain pulley Block with monorail Geared Travelling Trolley CAP: 2.0 T LIFT: 6.0 MTR/20.00 feet (ISI Mark)
S & F Elect Control Panel 3.0 Kw, 3 phase DOL Starter, Ammeter , Voltmeter, SPP, Thirmister, Moisture Sensor,Over Load Relay , Contactor, in – Out Terminal, Connector, Fuse Unit, Dully wn metal box.
Supply and fix GI bracket of 25mm medium grade of length 1.5 mtr including nut, bolts, washers and clamps for fixing complete all as specified and directed
Supply and fix LED street light 45 W IP 65 complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of make Bajaj cat part No BRLEP45WLED & equivalent of Havells/ Crompton.
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized iron strip earth 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete as detailed below and all as directed.
NOTES :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
EXTERNAL WATER SUPPLY AND RISING MAIN
supply and lay DI pipes of size 100 mm dia with spigot and socket ends with tyton joint S/S class K-9, in any length, laid in trenches including testing on completion complete all as specified and directed. Note: - 1. Ductile Iron Specials/Fittings , excavation and earthwork shall be measured and paid separately. 2. Unit rates includes for all jointing and jointing materials.
Supply and lay DI FITTINGS such as bends (any radius and angle) tapers any type (straight bend, increasing, decreasing or double socket etc. tee pieces etc. 80 to 150 mm bore with tyton joint S/S class K-9, Note: - 1. excavation and earthwork shall be measured and paid separately. 2. Unit rates includes for all jointing and jointing materials.
S & F nut bolt alongwith washers suitable for 150mm flanged DI pipe as per OEM recommendation complete all as specified and directed
EXTERNAL ELECTRIC SUPPLY
Supply, install, testing and commissioning including transportation at site, transformer of Energy efficient level-3, step down outdoor ONAN type copper wound of capacity 100 KVA , 11 KV on HT side and 433 Volt on LT side at no load, 3 phase 4 wire, 50 Hz, AC supply oil immersed, laminated iron core naturally cooled with external cooling tubes, delta connected on HT side and star connected on LT side, corresponding to vector group DYN- II with neutral brought out separately for earthing, off load tap changing arrangements on HT side to vary secondary voltage +7.5% in steps of + 2.5%, with and including cable box on HV and LV side complete complete on and including stone masonry platform of size 2 m x 2 m.x 2 m with appropriate foundation plastered all over top laid with 100 mm PCC 1:2:4 finished even and smooth and applied black synthetic enamel paint two coats over priming coat all over with first filling of transformer oil upto appropriate level conforming to IS complete as per manufacturer recommendation complete with standard fittings conforming to latest edition of IS-1180 (part-I)-2014 and mainly comprising of ECBC norms or latest IS complete all as specified & directed including following accesories all as specified and directed by engineer-in-charge. (a) One cable box HV side consisting of 3 nos porcelain terminal points incl nuts and washer with two nos cable gland suitable for up to 3 core 120 sqmm HT UG cable (b ) Suitable cable box LV side for mounting two LV cable consisting of 4 Nos porcelain with brass bushing rods , complete with nuts and washer with two nos cable gland suitable for LT UG cable providing with bimettalic lugs . ( c ) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover incl thermometer. (g) Rating plate and terminal marking plate. (h) The earthing terminal two nos to tank to faciliate fixing to earth strip. (i) Oil level gauge. (j) Lifting lugs (k) Oil filling hole with cap / plug with connection plate complete. (l) Air relief valve plug. (m) four plan solid cast steel detachable roller for transformer (n) 01 No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade (o) All other items as specified under particular specification.
Supply & fix cable path indicator made of RCC (size 0.2 m * 0.1 m * 0.75 m hight) 1 : 2 : 4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars 100 mm c/c horizontally vertically , Voltage & Cable size mentioned in bold letters painted with brown paint & black ground with two coats of yellow paint in foundation PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregated of size 0.3 mtr * 0.2 mtr * 0.2 mtr including necessary exavation & earth work removal compete all as specified and directed.
Supply, install, testing and commissioning of LT main panel box company fabricated, outdoor type made out of MS CRCA sheet 3.0 MM thick with angle iron frame 50x50x6mm floor mounted support suitable for 3 phase 4 wire 50 Hz, 415V system weather and vermin proof double door including front and back opening, all internal connections incoming to outgoing with Bus bar, chromium plated brass cable glands painting with a coat of red oxide primer and powder coated paint of approved colour and make complete with structure, insulators, nuts and bolts, washers etc including PCC for fixing and consisting of the follow :- (a) MCCB TPN, 160 Amps, 415 volts (for incoming) 35 KA- 01 No (b) Bus bar with aluminium strip of capacity 200 Amps for 3 phase and neutral system with CTS-01 Set (c) Digital panel meter for volt, Amp, KWH, PF and other parameter flush mounting of size 96x96mm (d) MCCB, 4 pole TPN, 100 Amps 415 Volts (for outgoing) 35 KA - 02 Nos (e) MCB SPN 20 Amps, 415 Volts (for outgoing) 10 KA - 01 No (f) Internal fine wiring with suitable size and rating of wire
Supply, install, testing and commissioning of copper cable for power 4 core x 2.5 Sqmm area for internal connections of STP Plant in and including PVC conduit complete all as specified and directed
DG SET
Supply, installation, testing and commissioning of manufacture of OEM manufactured static silent (Sount proof enclosure) diesel engine driven Generator Set capacity of 100 KVA water cooled, 415 volts (AC 3 phase 4 wire system of supply) 50 Hz at power factor 0.8, minimum. The DG Set shall consist of diesel enginer coupled to a matching alternator through flexible coupling and mounted on common based frame and complete with control panel standardized by manufacture, fuel tank with mounting arrangment and inlet outlet return inlet oil arrangement exhaust pipe complete and suitable for condition (capacity of engine alternator shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for easy of movement and 0.5 m height) and vibration parts including all features to complete with latest CPCB guideline and comprising of following :- (a) Engine (Prime mover). Diesel engine 100 KVA direct injection, type four stroke conforming to IS 3046/BS 5514, water cooled, naturally turbo changed, capable of giving adequate BHP to drive laternator capable of delivering 100 KVA at outdoor atmospheric conditions. (Taking all derating factor into consideration), 240 volts (As per manufacture recommendatoin) electric battery start with suitable battery, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with techometer lubricant oil, temperature, pressure guage and frequency meter and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and engine protection system (shut down, high water temperature, low lubricant oil, oil pressure, over speed etc) fuel tank and first fill of lubricant oil and other consumables etc (b) Alternator. Brushless AC alternator, 3 phase, 415 Volts, 4 wire, rated for output of 100 KVA, minimum power factor 0.8, 1500 RPM, IP-23 protection class enclosure, induction class 'H' sailent pole, revolving field single bearing automatic voltage regulator coupled through flexible coupling with and to match above engine. (c) Base Plate. Made out of structural steel as per manufacturer recommended designs/specification.
(d) Automatic Control Panel. Factory made cubical type floor mounted LT panel board, indoor type made out of MS angle not less than 25x25x5mm and 1.6mm thick MS CRCA sheet, front opening type, protection class IP-54 duly powder coated after seven tank process with electrolytic grade copper bus bar of 250 Amp capacity for four poles, with all standard switchgear and protection internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of following :-
(i) AMF logic panel including wiring power contactor with MCCB/ACB suitable capacity for DG set of main supply, single phase preventor, digital multifunction meter (Showing Amps, volts, Hz, KWH etc) emergency stop button, DG over load, high water temperature, low lubricant oil pressure, auto charging unit and failure to start, phase indication lamp LED type RYB including all relay, circuit and protection required for automatic operatin of DG Set (e) Accoustic Enclosure. Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75DB (A) at a distance of 1 m at 75% load under field condition and OX, 70 DB at 3 m from gen set when DG set is working at full load alongwith testing conformance, levelling certificatoin etc as laid down in GSR NO 371 (e) dt 17 May 2002 (f) Foundation/Plinth/Base. Shall be provided as per manufacturer recommendations, how ever minimum 0.5m space should be available all around the set and height of plinth shall not be less than 0.5 m. (g) Diesel storage tank of capacity adequate for storage of diesel for 12 hrs operation of Gen Set (h) Misc - Tool kit operation and maintenance catalogue spare part list overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices
Supply, installation, testing and commissioning of manufacture of OEM manufactured static silent (Sount proof enclosure) diesel engine driven Generator Set capacity of 15 KVA water cooled, 415 volts (AC 3 phase 4 wire system of supply) 50 Hz at power factor 0.8, minimum. The DG Set shall consist of diesel enginer coupled to a matching alternator through flexible coupling and mounted on common based frame and complete with control panel standardized by manufacture, fuel tank with mounting arrangment and inlet outlet return inlet oil arrangement exhaust pipe complete and suitable for condition (capacity of engine alternator shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for easy of movement and 0.5 m height) and vibration parts including all features to complete with latest CPCB guideline and comprising of following :- (a) Engine (Prime mover). Diesel engine 15 KVA direct injection, type four stroke conforming to IS 3046/BS 5514, water cooled, naturally turbo changed, capable of giving adequate BHP to drive laternator capable of delivering 15 KVA at outdoor atmospheric conditions. (Taking all derating factor into consideration), 240 volts (As per manufacture recommendatoin) electric battery start with suitable battery, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with techometer lubricant oil, temperature, pressure guage and frequency meter and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and engine protection system (shut down, high water temperature, low lubricant oil, oil pressure, over speed etc) fuel tank and first fill of lubricant oil and other consumables etc (b) Alternator. Brushless AC alternator, 3 phase, 415 Volts, 4 wire, rated for output of 15 KVA, minimum power factor 0.8, 1500 RPM, IP-23 protection class enclosure, induction class 'H' sailent pole, revolving field single bearing automatic voltage regulator coupled through flexible coupling with and to match above engine. (c) Base Plate. Made out of structural steel as per manufacturer recommended designs/specification.
(d) Automatic Control Panel. Factory made cubical type floor mounted LT panel board, indoor type made out of MS angle not less than 25x25x5mm and 1.6mm thick MS CRCA sheet, front opening type, protection class IP-54 duly powder coated after seven tank process with electrolytic grade copper bus bar of 250 Amp capacity for four poles, with all standard switchgear and protection internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of following :- (i) AMF logic panel including wiring power contactor with MCCB/ACB suitable capacity for DG set of main supply, single phase preventor, digital multifunction meter (Showing Amps, volts, Hz, KWH etc) emergency stop button, DG over load, high water temperature, low lubricant oil pressure, auto charging unit and failure to start, phase indication lamp LED type RYB including all relay, circuit and protection required for automatic operatin of DG Set (e) Accoustic Enclosure. Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75DB (A) at a distance of 1 m at 75% load under field condition and OX, 70 DB at 3 m from gen set when DG set is working at full load alongwith testing conformance, levelling certificatoin etc as laid down in GSR NO 371 (e) dt 17 May 2002 (f) Foundation/Plinth/Base. Shall be provided as per manufacturer recommendations, how ever minimum 0.5m space should be available all around the set and height of plinth shall not be less than 0.5 m. (g) Diesel storage tank of capacity adequate for storage of diesel for 12 hrs operation of Gen Set (VIII) Misc - Tool kit operation and maintenance catalogue spare part list overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to strip earthing 4mm dia GI earth wire by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete as detailed below and all as directed.
NOTES :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
STP EM ITEMS
Supply, install, testting and commisioning of SS 304 Mechanical coarse screen of 0.800 m x 7.5 m capacity with all necessary fittings for screen channel complete all as specified and directed.
Supply, installation, testing and commissioning of 70 Cum/Hr flow rate capacity pump submersible non clogging at 15 mtr head for Wet well complete with suitable motor and all connected accessories complete all as specified and directed Note : Cost of foundation as specified by OEM included in quoted rate.
Supply and fix Non Return Valve, (Reflux), with by-pass Arrangement, 100 mm (4”) dia, 1.6 PN complete all as specified and directed.
Supply and fix Valve, butterfly conforming to IS 13095,100 mm (4”) dia complete all as specified and directed.
Supply, installation, testing and commissioning of Float type Level switch (vertical) for pumping station for equalization tank,chlorine contact tank,teritary treated water tank,sludge tank and Wet well complete all as specified and directed.
Supply, installation, testing and commissioning of 100 mm dia dial Pressure gauge 0-7 kg/cm2 for pumps complete all as specified and directed
Supply, installation, testing and commissioning of Manual Fine Screen (SS 316 screen of 0.400 m wide x 2 m length) complete all as specified and directed.
Supply, installation, testing and commissioning of 50 Cum/Hr flow rate capacity pump submersible non clogging at 12 mtr head for Equilization tank complete all as specified and directed Note : Cost of foundation as specified by OEM included in quoted rate
Supply, installation, testing and commissioning of Air blower (twin lobe Blower) with standard accessories, Twin lobe blower, suction cap 500 M3/hr, suction pressure atmosphere, suction temp ambient, discharge pressure 0.5/kg cm2, blower speed 1400 RPM, BHP at duty point 15.8 BHP, motor 20HP/1500 RPM, Drive V blet, cooling Air cooled, duty continueous, rotation clockwise, lub oil viscocity -ISO-VG 320/ servosystem, Suitable std elect motor-01 complete all as specified and directed.
Supply, installation, testing and commissioning oF Fine Bubble EPDM Diffuser Dia 90mm x 1000 mm diffuser with 1 inch Air inlet connection and SS nipple EPDM membranes duly clamped all as specified for MBBR tank complete all as specified and directed
Supply, installation, testing and commissioning oF Coase Bubble Wide band Diffusers Dia 90mm x 800 mm diffuser with 3/4 inch Air inlet connection and SS nipple all as specified for Equalization tank complete all as specified and directed
Supply, installation, testing and commissioning of MBBR Media float CD BF 22, PP with UV stabilized. Dia 22mm, ht 20 mm, surface area 500 m2/m3, Loose media in bags Tank: 4 m X 7 m X 4.2 m LD complete all as specified and directed
Supply, installation, testing and commissioning of Tube Settler Media PVC Tubes CD-TS120 (Loose Leaves) Surface Area: 11m2/m3 at 60 deg Angle inclination; vertical ht 750 mm Tank: 4.5 m X 4.5 m X 4.5 m complete all as specified and directed
Supply, installation, testing and commissioning of the vessel 2 mtr dia & 2 m Height of multigrade media filter with necessary fitting and piping complete all as specified and directed
Supply, installation, testing and commissioning of the vessel 2 mtr dia & 2 m Height of activated carbon filter with necessary fittings and piping complete all as specified and directed
Supply, installation, testing and commissioning of Filter feed pump of capacity 25 Cum/hr and 22 mtr head near chlorine contact tank alongwith suitable motor and connected accssories complete all as specified and directed Note : Cost of foundation as specified by OEM included in quoted rate
Supply and fix Non Return Valve, (Reflux), with by-pass Arrangement, 80 mm (3”) dia, 1.6 PN complete all as specified and directed
Supply and fix Valve, butterfly conforming to IS 13095,80 mm (3”) dia. complete all as specified and directed
Supply, installation, testing and commissioning of submersible non clog Sludge transfer pump of capacity 8 cum/hr and 15 mtr head near sludge tank complete all as specified and directed.
Supply and fix Valves, Sluice, flanged of class 1.6 PN ,100 mm (4”)dia. drain/TS media drain/MBBR Drain/grit chamber complete all as specified and directed
Sliding Gate 32 x 32 mm MS square frame structure with cast iron plate with dia 32 mm thraded shaft with 75 mm x 40 mm top side channel support included fixture fitting and accessories Size 200 mm x 200 mm
Supply, installation, testing and commissioning of dosing pumps Hypochloride solutions and conneted accessories complete all as specified and directed
Supply, installation, testing and commissioning of dosing pump for poly dosing including conneted accessories alongwith Pump set model name: DMX 27-10 Grundfos dosing head: PVC complete all as specified and directed
Supply, installation, testing and commissioning of Poly dosing Mechanical Aggitator for suitable RPM with gear box assembly and motor including connecting accessories complete all as specified and directed.
Supply, installation, testing and commissioning of submersible non clog dewatering pump of capacity 8 Cum/hr and 15 mtr head as per requirement complete all as specified and directed. Note : Cost of foundation as specified by OEM shall deemed to be included in quoted rate.
Supply, installation, testing and commissioning of Digital Flow transmitter Flanged & type Supply -230 V * 5 Amp, Output 4-20-uA, Housing:Weather proof, for nominal dia 100 & 150 mm Protection Class for Sensor : IP 65 complete all as specified and directed.
Supply, installatin, testing and commissioning of DO analyzer with output 4 day 20VA, DC with LCD display range 0-20PPM, accuracy + 1% FS, response time <500ms, flame proof, IP-65 protected CMRI certified complete all as specified and directed
Supply, installation, testing and commissioning of Proportionate weir SS 304 of capacity 400 mm x 650 mm for grite chamber complete all as specified and directed.
Supply and lay Pipe PVC class “B” conforming to IS 13592 including Special OD 160 mm dia complete all as specified and directed.
Supply, installation, testing and commissioning of filter press with Electro Mechanical Plate Shifting Device Plates type Filter Press of SIZES 1200 X 1200 mm for 7 bar Filtration Pressure with hydraulic closing devices.Moc of Filter Element : Polypropylene Cast Iron, SS 304, SS 316 Liquid Holding capacity - 55 Lit Moc of Skeleton : Cast Iron or Mild Steel complete all as specified and directed
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible copper cable, four runs of 2.50 sqmm main cable and two runs of 2.50 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB UPVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - four runs of main cable + two runs of earth conductor and one run of UPVC condduit shall be measured as one RM.
Supply, install, testting and commisioning of LT panel box company fabricated, indoor type made out of MS CRCA sheet 2.0mm thick with angle iron frame 40x40x6mm floor mounted support suitable for 3 phase 4 wire 50 HZ, 415V system weather and vermin proof, all internal connections incoming to outgoing with BUS BAR of capacity 200 Amps. Incoming MCCB 4 Pole-160 Amp 50 KA, outgoing fully automatic star delta 3 phase starter 5 kw-03, fully automatic star delta 3 phase starter 0.5 kw-01, fully automatic star delta 3 phase starter 3.5 kw-02, fully automatic star delta 3 phase starter 12 kw-03, fully automatic star delta 3 phase starter 2.5 kw-03, fully automatic star delta 3 phase starter 0.75 kw-02, fully automatic star delta 3 phase starter 14 kw-03, fully automatic star delta 3 phase starter 2.3 kw-01, MCB TPN 63A-01, including push button for start/stop for each starter including multifunctin meter (KWH, Amp, Voltage), indicaiton lamp, MCCB of suitable capacity for each starter complete all as specified and directed
Supply, install, testting and commisioning of LT Main panel box company fabricated, outdoor type made out of MS CRCA sheet 3.0mm thick with angle iron frame 50x50x6mm floor mounted support suitable for 3 phase 4 wire 50 HZ, 500V system weather and vermin proof double door including front and back opening, all internal connections incoming to outgoing with BUS BAR, chromium plated brass cable glands painting with a coat of redoxide primer and powder coated paint of approved colour and make complete with structure, insulators, nuts and bolts, washers etc includng PCC for fixing and consisting of the following :- (a) MCCB TPN, 160 Amps, 415 volts (for incoming) 35 KA-01 No (b) Bus bar with copper strip of capacity 200 Amps for 3 phase and neutral system with CTs - 01 Set (c) Digital panel meter for volt, Amp, KWH, PF and other parameter flush mounting of size 96 x 96mm Make : Secure/AE/Conzerv (d) MCCB, 4 pole TPN, 100 Amps, 415 Volts (for outgoing) 35 KA - 02 Nos (e) MCB SPN 20 Amps, 415 Volts (for outgoing) 10 KA - 01 No (f) Internal fine wiring with suitable size and rating of wire
Supply, installation, testing and commissioning of Cu cable for power 4 core x 2.5 Sqmm area for internal connections of STP plant in and including PVC conduit complete all as specified and directed
S & F wall security street light 45 Watt IP-65 LED type prewired and including connecting up with twin core flexible copper conductor cable ,complete with and inlcuidng GI pipe 40 mm dia bend to shape required of length 1.5 mtr and fixing on wall/pole with clamp, nut & bolt complete all as directed and specified by Engr-In-Charge. CAT Part No.BRLEP45WLED watt of Make Bajaj or technocommercial equivalent of make as approved by GE.
Outsourcing services for running of sewage treatment plant and installation comprising of all plants/machinery/equipment/ devices etc and operation of two pumps at earthenpond includng Sunday and holiday with mobile connectivity to receive instruction at installation during duty Note : One FGM and two helpers in 02 (two) shifts each of 8 hrs each in a day. Duration of shifts as directed by GE. Note : After completion of work for a period of 11 months.
Outsourcing services for running of sewage treatment plant installation comprising of all plants/machinery/equipment/ devices etc and operation of two pumps at earthenpond including Sunday and holiday with mobile connectivity to receive instruction at installation during duty Note : One FGM and two helpers in 02 (two) shifts each of 8 hrs each in a day. Duration of shifts as directed by GE. Note : After completion of item No 108.00 above for period of next 11 months
Notes for Item No 108.00 to 109.00 (i) The contractor shall employ one FGM and two helpers per shift. The FGM shall be qualified & experienced in field and experience not less than 2 years in the same field. (ii) Cost of the periodical maintanance of various equipments / parts shall be deemed to be included in quoted rate of respective items. (iii) The contractor shall strictly follow the operation and maintanance manual of the plant. (iv) Periodic cleaning and manintanance of plant. (v) The log sheet shall be maintained by the contractor including provision of required printed log sheet book as directed.
Ms Hari Deva Builders
S AND A ENGINEERS CONSTRUCTION CO
M/s Gujarat Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .