Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹27.7 L+₹7.4 L (33.9%)Accepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L2 | Accepted-AOC L1 Bidder among bonafide bidders | |
| 2 | L1₹21.9 LRejected-Finance | L1 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. APPROVAL OBTAINED FROM PCDA | |
| 3 | L3₹31.2 L+₹9.3 L (42.6%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. APPROVAL OBTAINED FROM PCDA | |
| 4 | L4₹38.1 L+₹16.2 L (73.9%)Rejected-AOC 6 341 RATAN VIHAR NANGLOI DELHI 110041 | DELHI | WEST DELHI | DELHI | 110041 | L4 | Rejected-AOC L2 Bidder among bonafide bidders | |
| 5 | L5₹39.4 L+₹17.5 L (79.7%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L5 | Rejected-AOC L3 Bidder among bonafide bidders |
Tender Value
₹47.4 L
EMD Value
₹94,760
Closing Date
3 Nov 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
OUTSOURCING OF SERVICES FOR MANNING AND OPERATION OF WATER SUPPLY INSTALLATION, RO PLANT IN ANUSANDHAN VIHAR, RO PLANT IN CENTRAL PARK AND LIFT INSTALLED IN ADMIN BUILDING AT INMAS SOF E BLOCK AND NAG CHAUDHARY HOSTEL UNDER GE I RND DELHI
2020_MES_363579_1
GE/RND-45/DLI/2020-2021
Open Tender
Manpower Supply
Item Rate
330 days
DELHI
Class D, Cat d(v)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹94,760
Yes
21 Dec 2020
23 Jul 2020
7 Nov 2020
23 Jul 2020
3 Nov 2020
22 Oct 2020
Amount
PART-1 OUTSOURCING SERVICES Outsourcing services for manning and operation of RO Plant at central park of capacity 10000 ltrs/hrs by deploying one experienced qualified skilled mechanic cum operator, round the clock including Sunday and holidays in three shifts per day of 08 hours each (Ist shift from 0600hrs to 1400hrs, IInd shift from 1400hrs to 2200hrs and IIIrd shift from 2200hrs to 0600hrs) complete inclusive of daily maintenance of equipments. Scope of work as given below & as directed by Engr-in-charge complete all as specified and as directed.
Scope of Work for srl item No. 1 comprises:- (i) Main panel Board having main incommer MCCB 250A, 36kA, 4 Pole (ii) Automatic panel having main incommer MCCB 250A, 36 kA, 3 Pole L&T -01 No. (iii) LT panel having main incommer MCCB 125A, 36 kA, 3 Pole L&T -01 No. (iv) UG Sump 50000 ltrs-02 Nos (v) 5.5 KW VT monoblock pump and motor-02 Nos (vi) Filter Media-01 No. (vii) Primary filter with SS casing-02 Nos having 10 filter each of 30 inch height. (viii) High pressure VT monoblock pump and motor of capacity 15 KW-02 Nos. (ix) Membrane tubes 3 Nos having 5 membrane each (x) PH Controller tank with blower and motor-01 No. (xi) Clear water VT monoblock pump and motor of capacity 5.5 KW -02 Nos. (xii) 7.5 KW monoblock pump and motor for cleaning of membrane for citric acid tank with two filters of 20 inch height. (xiii) 06 Nos Chemical dosing pump with tank capacity 100 ltrs. (xiv) Operation of valves for feeding of Block Nos-A,B,C,D,E,P-25,P-28,Nag choudhary, Bhagwantam hostel,Raman hostel,& PVC tanks at Mandhir, complaint cell, NGO, Transit facilities and further to DSC lines SSPL outer,inside DIPR with 3 HP monoblock Pump and motor. (xv) Cleaning of RO plant room and five meters around the outside of building and roof. (xvi) Bore well with submersible pump set 5 HP / 7.5 HP capacity. Make : KSB. (xvii) Maint and operation of all the Valves and Pipe lines in the RO plant room.
Outsourcing services for manning and operation of RO Plant at Anusandhan vihar of capacity 10000 ltrs/hrs by deploying one experienced qualified skilled mechanic cum operator per shift per day, round the clock including Sunday and holidays in three shifts per day of 08 hours each (Ist shift from 0600hrs to 1400hrs, IInd shift from 1400hrs to 2200hrs and IIIrd shift from 2200hrs to 0600hrs) complete inclusive of daily maintenance of equipments. Scope of work as given below & as directed by Engr-in-charge complete all as specified and as directed.
Scope of Work for srl item No. 2 comprises:- (i) Main incommer MCCB 400A, 35kA, 4 Pole (ii) LT panel having main incommer MCCB 200A, 35 kA, 3 Pole-01 No. (iii) Automatic control panel -01 No. (iv) UG Sump 200000 ltrs. (v) Raw water VT monoblock pump and motor of capacity 7.5 HP-02 Nos. (vi) Filter Media-02 Nos & Softener with air blower-01 Nos. (vii) High pressure VT monoblock pump and motor of capacity 22 KW-02 Nos. (viii) Membrane tubes 4 Nos having 5 membrane each including 20 inch filters-12 Nos. (ix) PH Controller tank with one blower and 02 Nos monoblock pump and motor of capacity 1.2 KW. (x) PVC RO water tank 04 Nos having capacity 10000 ltrs each. (xi) 5.5 KW VT monoblock pump and motor for cleaning of membrane for citric acid tank with two filters of 20 inch height. (xii) Clear water pump and motor 5.5 KW -02 Nos. (xiii) Supply soft water for bathing & cleaning having VT monoblock pump and motor of capacity 7.5 HP-02 Nos. (xiv) Supply water for flushing having VT monoblock pump and motor of capacity 7.5 HP-02 Nos.
Rate required to be quoted for executing the work as described in Ser item No 1.00 to 2.00 above
Workers wage per person as per existing rules
ESIC (Employees state insurance contribution) as mentioned in tender document
Bonus as mentioned in tender documents
Overhead & Profit on Ser No 3.01 to 3.03
LWC as mentioned in tender documents.
GST as mentioned in tender documents.
Notes : Rate quoted by the contractor shall deemed to be included the following :- (i) Operator cum mechanic (skilled) shall be of Diploma/ITI passed with having training certificate in relevent trade not less than three year shall be employed for each shift.. (ii) It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/State Govt/Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC , Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable. (iii) In case the rates quoted by tenderer are less than the notified minimum wages as on bid submission end date including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable, his tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongst valid/bonafide bids only. (iv) The firm/contractor shall be solely and fully responsible to his reprsentative/personal for any accident/damage during maintenance/operation/health related liabilities/compensation, penelty etc on this account. (v) T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost.
(vi) Contractor shall be responsible to maintain log books, duty roster attendance register and spare for repair/renewal of parts register, earth register, serviceability register of lifts and as directed by Engr-in-charge. (vii) Shift Operator (reliever) shall neither leave the installations without prior permission of JE/Engineer-in-Charge. Proper handing/taking over to the next operator will be made. (viii) Two pairs of uniform with name plate of operator & firm and shoes shall be provided to each operator by the contractor. (ix) Cleaning of complete lift, machine room of lift, greasing, tightening of nuts , bolts will be carried out by the operator employed by the contractor. (x) First Aid box will be provided by contractor at each installation. (xi) Any increase in minimum wages of labour as fixed by the Govt of India/state Govt/ union Territory, whichever is higher shall be paid to the contractor in accordance with the provision made vide condition 63 of IAFW-2249. Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. no other claim whatsoever shall be addmissible on this account and the bidders shall consider this aspect while quoting their rates. It must be noted that in compliance of the statutory provisions, the increased will be passed over to the workers. (xii) Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt for this shall be maintained by the Engineer-in-Charge & contractor.
(xiii) The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates. (xiv) Duty roster for detailement of operators shall be approved by Engr-in-charge within first three days of every month and the same shall be kept on record and properly displayed at each installation. (xv) The contractor will arrange the earth tester, Megger & clamp meter for installation and will check all the earthings of lifts for its serviceability in presence of JE E/M, Engr-in-Charge and test report shall be submitted to the office of AGE E/M duly signed by the contractor on commencement of work for record. (xvi) For any damage to the installations due to negligence of operator such as loose connections, improper routine check up/maintenance etc. the contractor shall be held fully responsible to replace the same damage at his own cost all as directed by Engr-in-charge. (xvii) Original certificates regarding qualifications of operators engaged in the work, police verification and identity proof shall be produced by the contractor to the Engineer-in-Charge for verification and approval.
PART-II: REPAIR/MAINT WORKs Excavation in trenches in soft/loose not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep and getting out complete all as specified and as directed.
All as per item No. 4.00 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc.
Returning, filling in and including spreading, leveling, watering and well ramming in layers not exceeding 25 cm to achieve desired compactness complete all as specified and directed.
Removing surplus soil to a distance exceeding 1.5Km but not exceeding 5Km and deposited where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M&L for Brick work with sub class 'B' old size bricks straight or curved on plain exc. 6 m mean radius bult in CM 1:4 including demolition of old brick work complete all as specified and directed.
M&L for PCC (1:4:8) type D-1(using 40 mm graded stone aggregate) as in foundation complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) finished even and smoooth without using extra cement as in floor, coping etc complete all as specified and directed.
M&L for Rendering 10 mm thick on brick work/concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed.
Taking down/out GI pipe water mains of size 80mm bore including all fittings complete all as specified and directed.
Taking down/out GI pipe water mains of size 100mm bore including all fittings complete all as specified and directed.
Taking down/out GI pipe water mains of size 150mm bore including all fittings complete all as specified and directed by Engr-in-Charge
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor of size 15mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor of size 20 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor of size 25 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor of size 40 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor of size 50 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor of size 80 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor of size 100 mm bore complete all as specified and directed.
Supplying, Laying, jointing, testing and commmisioning of DI Pipe of 150 mm bore size, with spigot and socketed ends centrifugally cast Class K-7 Push on joint confirming to IS 8329 laid in trenches complete all as specified and directed.
M&L for DI fittings for spigot/socket pipes such as bends of any radious and angle, collars, tapers, tail pieces, Tee pieces, Caps and plugs suitable upto 150 mm bore dia all socketed or socket and spigot or side flanged complete all as specified and directed.
M&L for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrieved lead adding minimum 700gm new lead for CI pipe of 150mm bore pipes complete all as specified and directed.
M&L for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrived lead and adding minimum 500gm new lead for CI pipe of 100mm bore pipes complete all as specified and directed.
M&L for burning out lead joint in any position including removing old lead joint and making new lead joint for CI pipe of 80mm bore complete all as specified and directed.
S&F in repair for Rubber Gasket Joint (tyton joint) including jointing material for DI/CI pipe of size 150 mm bore dia, complete all as specified and directed.
Supplying, laying jointing testing MS pipe, of 80 mm dia Heavy duty class 'C' confirming to IS-1239 laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed. (Note : Welded flanges will be measured and paid seperately.)
All as ser item No. 28.00 above but 100mm dia.
Supply and fixing welded to flanges on ends for MS pipe of 80 mm dia, flange not less than 15mm thick, complete all as specified and directed.
Supply and fixing welded to flanges on ends for MS pipe of 100mm dia, flange not less than 15mm thick, complete all as specified and directed.
Supply and fixing welded to flanges on ends for MS pipe of dia 150 mm, flange not less than 15mm thick, complete all as specified and directed.
M&L for Joints with rubber or fibre board gasket of size 80 mm complete with nut,bolt and double washers complete all as specified and directed.
M&L for Joints with rubber or fibre board gasket of size 100 mm complete with nut,bolt and double washers complete all as specified and directed.
M&L for Joints with rubber or fibre board gasket of size 150 mm complete with nut,bolt and double washers complete all as specified and directed.
S&F in repair of cast iron Sluice Valve of dia 80 mm ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
All as per ser item No. 36.00 above but 100mm.
All as per ser item No. 36.00 above but 150mm.
All as per ser item No. 36.00 above but 200mm.
S&F in repair CI Non return Valve of dia 80 mm with GM seat, PN-1.0 ISI marked, including flange joints such as packing, nut and bolts etc complete all as specified and directed.
All as per ser item No. 40.00 above but 100mm.
All as per ser item No. 40.00 above but 150mm.
All as per ser item No. 40.00 above but 200mm.
S&F in repair foot valve flanged type of dia 80 mm with strainer confirming to IS:4038 with flanged ends complete all as specified.
All as per ser item No. 44.00 above but 100mm.
All as per ser item No. 44.00 above but 150mm.
Labour for cutting of existing CI/DI pipe of dia 80 mm for insertion of CI specials /valves etc. including dewatering of lekage water all as required complete all as specified and directed.
All as per ser item No. 47.00 above but 100mm.
All as per ser item No. 47.00 above but 150mm.
S&F in repair PTMT Float valve of dia 15 mm with epoxy coated aluminium rod and high density ball including fitting complete all as specified and directed.
All as per ser item No. 50.00 above but 20mm.
All as per ser item No. 50.00 above but 25mm.
All as per ser item No. 50.00 above but 40mm.
All as per ser item No. 50.00 above but 50mm.
S&F in repair Gun Metal gate valves of size 15 mm dia with iron wheel head,screwed both ends for iron pipe, ISI Marked, as per IS: 778 complete all as specified and directed.
All as per ser item No. 55.00 above but 20mm.
All as per ser item No. 55.00 above but 25mm.
All as per ser item No. 55.00 above but 40mm.
All as per ser item No. 55.00 above but 50mm.
S&F in repair flanged water meter woltman type of dia 50 mm complete all as specified and directed.
S&F in repair flanged water meter woltman type of dia 80 mm complete all as specified and directed.
S&F in repair flanged water meter woltman type of dia 100 mm complete all as specified and directed.
S&F in repair flanged water meter woltman type of dia 150 mm complete all as specified and directed.
S&F in repair Strainer Y type conforming to IS, size 80 mm (3”) dia.
S&F in repair Strainer Y type conforming to IS, size 100 mm (4”) dia.
S&F in repair Strainer Y type conforming to IS, size 150 mm (6”) dia.
M&L for painting with two coat of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel surface all as specified and directed.
M&L in repair of mild steel work, i.e MS sheet/angle iron, hinges etc incluidng cutting, welding etc complete all as specified and directed.
S&F in repair of power contactor of current rating upto 60 Amps and standard coil voltage 240v, 50Hz type ML-2 of aux contact (2 NO + 2 NC) including reconnection of cable complete all as specified and directed.
All as ser item No. 69.00 above but current rating upto 60 Amps and standard coil voltage 240v, 50Hz type ML-3.
All as ser item No. 69.00 above but current rating upto 125 Amps and standard coil voltage 240v, 50Hz type ML-4.
S&F in repair of chemical Dosing System consisting of FRP solution tank (made out of Bisphenol resin) of 100 Ltr. Capacity with lid cover and input port with electronic operated Diaphargm pump of capacity 06 ltrs per hour against maximum pressure of 4 Kg/cm2 (40mtr) complete with low level switch to stop pump at set level, level gauge. Make-CHLOROMAX/EDOSE/MILTON ROY UNICHLOR/ION EXCHANGE
M&L for bocky system under path/road to pass the GI/CI/DI Pipes upto 150 mm dia manually as directed..
Vishal Traders
BRIJ MOHAN LAL AND CO.
M/s Wazer Enterprises
Pradeep Bros
M/s Adhikari construction co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .