Executive Engineer STD Ganderbal
Executive Engineer STD Ganderbal
Stage contract for Maintenance Stabilization Improvement of 33 KV lines
2024_PDD_250709_1
STD GBL 02 OF 2024-25 DATED 20-06-2024
Open Tender
Electrical Works
Item Rate
7 days
Ganderbal and Bandipora
Refer SBD
8 documents required · 8 mandatory
₹1,000
Executive Engineer STD Ganderbal
₹30,000
19 Jul 2024
20 Jun 2024
10 Jul 2024
20 Jun 2024
9 Jul 2024
20 Jun 2024
20 Jun 2024 - 25 Jun 2024
Amount
Supply, Transportation, Erection, testing and commissioning including loading, unloading and carriage upto 50 mtr, as per REC standards
13 mtr ST Pole ST-410 SP69
11 mtr ST Pole ST-410 SP56
9 mtr ST Pole ST-410 SP33
Transportation from Divisional Store to Site, Erection, testing and commissioning including loading, unloading as per REC standards
13 mtr ST Pole ST-410 SP69
11 mtr ST Pole ST-410 SP56
9 mtr ST Pole ST-410 SP33
Erection, testing and commissioning of Dismantled/available at site ST pole including loading, unloading and manual carriage upto 50 mtr, as per REC standards
13 mtr ST Pole
11 mtr ST Pole
9 mtr ST Pole
Straightening of Tilted H- Frame after opening of half pits and refilling after straightening.
Straightening of Tilted ST poles after opening of half pits and refilling after straightening.
13 mtr ST Pole ST-410 SP69
11 mtr ST Pole ST-410 SP56
9 mtr ST Pole ST-410 SP33
Supply and painting of red oxide for Steel Tabular Poles
Supply and painting of Aluminum Paint for Steel Tabular Poles
Providing and laying of Cement Bottoming of ST Poles with 1:2:4 Mix including material and carriage
0.5 Cums for 9 Mtr pole
0.6 Cums for 11 Mtr pole
0.7 Cums for 13 Mtr pole
Refixing of Tilted Wooden poles after opening of pits and refilling after straightening.
Manual Carriage Charges for Steel Tabular Pole 13Mtr/11mtr/9 mtr for every additional 50 mtr or part thereof (including unloading/Loading)
Supply, Transportation,laying, Stringing, testing and commissioning of
200 sqmm ACSR Conductor
150 sqmm ACSR Conductor
100 sqmm ACSR Conductor
Transportation, laying, Stringing, testing and commissioning of
200 sqmm ACSR Conductor
150 sqmm ACSR Conductor
100 sqmm ACSR Conductor
Re- Straightening of loose Conductor/Fallen Conductor after opening of bindings and refixing thereof.
Shifting of Conductor from existing pole to the replaced pole within the 50 mtr which includes dismantling from existing pole to the newly erected pole
Supply, Transportation and fixing of GI Clamps/Collars for fixing X-arms using Flat iron
Supply, Transportation and fixing of GI Channel Iron /Cross arms/v cross arm/ F-Top of different sizes duly fabricated including clamps and collars
Transportation and fixing of GI Channel Iron /Cross arms/v cross arm/ F-Top of different sizes duly fabricated including clamps, Nuts & Bolts and collars
Supply, Transportation and fixing of GI Angle iron/Flat Iron/Brace of sorts including necessary fabrication as per site requirement.
Providing and fixing of Jumper for
200 sqmm ACSR Conductor
150 sqmm ACSR Conductor
100 sqmm ACSR Conductor
Supply, installation, testing and commissioning of Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8mm), nut-bolts,2 Nos turn-buckles, 1.8m long, 20mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete
SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (450x 450 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete.
Re-Fixing of Up-rooted Guys after opening of pits and refilling thereof.
Fixing of Guy with Turn Buckle and Guy Insulator
Providing and installation of Eathing Complete by GI Pipe 40 mm or GI rod 20 mm 3 mtr long through GI strip (Including transportation)
Supply, Transportation, fixing, testing and commissioning of 33 KV Isolator complete set with all accessories and clamps as per specification mentioned in DDUGJY SBD vol-III
With earthing Blade (36 KV, 800 A, Outdoor 3 poles, 25 KA)
Without earthing Blade (36 KV, 1250 A, Outdoor 3 poles, 25 KA)
Transportation, fixing, testing and commissioning of 33 KV Isolator (Including arranging of necessary accessories, Clamps and collar, Modification, fabrication for installation of 33 KV isolator, if required)
With earthing Blade (36 KV, 800 A, Outdoor 3 poles, 25 KA)
Without earthing Blade (36 KV, 1250 A, Outdoor 3 poles, 25 KA)
Supply, installation, testing and commissioning of 11 kV Isolator, double break,3-pole, 600Amp, horizontal mounting Type, with Earth Switch complete set including all accessories, Clamps and Collars. Specification of isolator should be as per the specifications mentioned in DDUGJY SBD vol-III
Transportation and fixing of 11 kV Isolator, double break,3-pole, 600Amp, horizontal mounting Type, with Earth Switch complete set (Including arranging of necessary accessories, Clamps and collar, Modification, fabrication for installation of 33 KV isolator, if required)
Supply and fixing of 33kv isolator parts including dismantling of existing damaged parts and necessary modification as per site requirment.
Fixed/movable post insulators including allied accessories
Vertical/horizontal GI rods of required sizes
Multi fingered female contacts including housing.
Isolator copper blade as per design and requirement
Supply and fixing of 11kv isolator parts including dismantling of existing damaged parts and necessary modification as per site requirment.
Fixed/movable post insulators including allied accessories
Vertical/horizontal GI rods of required sizes
Multi fingered female contacts including housing.
Isolator copper blade as per design and requirement
Supply and fixing of LED Street lights of 70/72 watts street IP-67 protected including providing of pipe fixture as per requirement, Providing of 2A MCB with box and 3-core 2.5 sq,mm copper cable complete job.
Fixing of LED Street lights of 70/72/90/120 watts including supply pipe fixture with necessary modification as per requirement, Supply of 2A MCB with box and 3-core 2.5 sq,mm copper cable complete job.
Supply, fixing, testing and commissioning of 33kV Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm of below mentioned typ
Polymeric composite Type
Porcelain type with out pins
porcelain type with pins
Transportation and fixing of Pin insulator complete-Porcelain/Polymeric with pins
Supply, fixing, testing and commissioning of 33kV Disc Insulator set 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting
Polymeric composite Type with fittings as per Conductor
Porcelain type with fittings (fitting as per Conductor)
Transportation and fixing of Disc Insulator with fitting
Repair of Damaged 33 KV Isolator by way of
Replacing damaged whole limb with new limb (limb mean isolator set has 3 limbs each limb contains 3 post insulator, copper blade/Rod clamps and collars, mechanism etc)( The damaged material is to be transported to Divisional Store).
Operating/Closing/opening Rod with handle
Supply and Fixing of 33 KV link Set with Copper blade/Knife of 50x6mm along with link/Operating Rod
Transportation and Fixing of 33 KV link Set after dismantling damaged one and transporting damaged one back to Divisonal Stores.
Supply and Fixing of 11 KV link Set with copper blade/Knife 50x6mm with link/Operating Rod
Transportation and Fixing of 11 KV link Set after dismantling damaged one
Supply, transportation, fixing of Guard netting with 6 & 8 SWG GI wire including Galvinized Nuts and Bolts and GI Channel X-arm including clamps and braces for single span ( standard span 116mtr)
Clearance of 33 KV Lines by way of cutting down trees, branches etc by means of
Conventional tools
Motorised Chainsaw cutter
Motorised Chainsaw cutter Provided by department
Supply and fixing of Galvanised Nuts and Bolts of various sizes
Supply and fixing of PG Clamps for
200 mm² ACSR Conductor
150 mm² ACSR Conductor
100 mm² ACSR Conductor
Transportation and fixing of PG Clamps for
200 mm² ACSR Conductor
150 mm² ACSR Conductor
100 mm² ACSR Conductor
Supply, Transportation and fixing of T-Clamps
Supply, Transportation and fixing of Pad Clamps/ tension clamps
Supply, Transportation and fixing of Danger Plates with Clamps
Supply, Transportation and fixing of Anti-Climbing Device with Clamps
Dismantling charges along with transportation charges upto Division Store.
13 mtr ST Pole with complete accessories
11 mtr ST Pole with complete accessories
9 mtr ST Pole with complete accessories
Wooden Poles with complete accessories
Lattice poles with complete accessories
200 mm² ACSR Conductor
150 mm² ACSR Conductor
100 mm² ACSR Conductor
Pin Insulator with pins
Disc insulator set with fittings
Channel iron cross arms/V-cross arms/F-tops
Angle iron Braces
Stay Set complete
Guard Netting (Standard Span116 mtr.)
Fixing of Pin insulator with pins
Fixing of Disc insulator set with fittings
Dismantlling and Re-erection of Dismantled material within the radius of 100 mtr.
Pin Insulator with pins
Disc insulator set with fittings
Channel iron cross arms/V-cross arms/F-tops
Angle iron Braces of any sorts
Guard Netting (Standard Span116 mtr.)
Hiring charges of Vehicle excluding fuel for Transportation of ST Poles- 13 mtr/11 mtr/9 Mtr/ACSR Conductor along with all alied material from Divsional store to Site or vice versa or from one site to another or for utilizing same vehicle for carrying restoration works during Heavy Rainfall/Snowfall or critical times.
Fuel Consumption of above hired vehicle per litre for Transportation of above material (fuel Charges shall be paid as per actual rates)
SHEIKH ELECTRICALS
M/S SALIQ TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .