Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Responsive |
| 2 | Accepted-Technical | Accepted-Technical Responsive |
| 3 | Accepted-Technical | Accepted-Technical Responsive |
| 4 | Accepted-Technical | Accepted-Technical Responsive |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹11.3 L
EMD Value
₹22,500
Closing Date
5 Aug 2026, 2:00 pmClosed
Superintending Engineer (Civil) New Power House
Superintending Engineer (Civil) New Power House
Maintenance for air conditionrs at Corporate office at NPH and Rest house Shastri circle and Zonal office, Jodhpur.
2026_JdVVN_579521_8
NIT No 05/D-726 Dt 21-07-2026
Open Tender
Civil Works
Percentage
360 days
Jodhpur
Tender Fee, Processing Fee, EMD, GST, IT, PF and ESI Reg. copy, Registration Copy, Stamp etc.
2 documents required · 2 mandatory
₹1,180
EA cash Jodhpur Discom Jodhpur
₹22,500
Yes
12 Aug 2026
30 Jul 2026
7 Aug 2026
30 Jul 2026
5 Aug 2026
30 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter.2.0 TR Window/ Split A.C. (E-26.42.3) | - | Each | - | - |
| 2 | Replacement of defective compressor by company repaired compressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.2.0 TR A.C. E-26.43.3) | - | Each | - | - |
| 3 | P & Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor 2.0 TR A.C.E-26/26.44.3 | - | Each | - | - |
| 4 | Servicing of 1.0/1.5/2.0 TR capacity Split/ Window type air conditioner E-26.45 | - | Each | - | - |
| 5 | P & Replacement of thermostat of A.C./ Water cooler/fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.(E-26.47) | - | Each | - | - |
| 6 | P & Replacement of selector switch of 1.0/1.5/2.0 TR A.C Fan as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.(E-26.48) | - | Each | - | - |
| 7 | P & Replacement of fan motor of evaporator/ condensor complete as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. (E-26.71) | - | Each | - | - |
| 8 | S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire Starting capacitor 40-60 micro farad E-26.72.1.2 | - | Each | - | - |
| 9 | P & Replacement of starting relay of A.C/water cooler/fridge compressor as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.E-26.49 | - | Each | - | - |
| 10 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Armoured 2 core x 2.5 Sq.mm E-22.38.2.3 | - | Meter | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.26 MB
BOQ_1030424.xls
BOQ • 0.25 MB
acnph.pdf
Tender Documents • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .