Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹50.0 LAccepted-AOC FLAT NO A 1108 TOWER P 2 ASHIYANA PALM COURT RAJNAGAR EXTENSION GHAZIABAD UP | GHAZIABAD | UTTAR PRADESH | 201001 | ₹50.0 L | L-1 | Accepted-AOC Work awarded |
| 2 | L-2₹50.8 L+₹81,134 (1.62%)Rejected-Finance | ₹50.8 L+₹81,134 (1.62%) | L-2 | Rejected-Finance Rejected due to higher rate |
| 3 | L-3₹51.2 L+₹1.2 L (2.49%)Rejected-Finance | ₹51.2 L+₹1.2 L (2.49%) | L-3 | Rejected-Finance Rejected due to higher rate |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
19 Jul 2023, 11:00 amClosed
Superintending Engineer
Electricity Distribution Circle, Rudrapur
Preventive Maintenance of 250 KVA, 400 KVA, 500 KVA. Transformers related to Electricity Distribution Sub Division, Rurapur-I under Electricity Distribution Division, Rudrapur-I
2023_UPCL3_60388_1
EDC(USN)30/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Rudrapur
Pl. refer tender documents.
4 documents required · 4 mandatory
₹5,900
EE ETD Rudrapur
₹1.0 L
5 Jun 2024
3 Jul 2023
20 Jul 2023
3 Jul 2023
19 Jul 2023
3 Jul 2023
Amount
Annexure -A ( Works )
Cartage of T/F oil drum from Store Center Haldwani/ Rudrapur/ Kashipur to Work Site Including Loading & Unloading safely (Distance upto 70 Km)
Cartage of Cable and other materials from Store Center Haldwani/ Rudrapur/ Kashipur to Work Site Including Loading & Unloading safely (Distance upto 70 Km)
Head load charges of T/F oil drum
Head load charges of cable and other materilas
Charges of Dismentaling of transformer from plinth, opening of all connections, circuits with help of required T&P of 250 KVA. Transformer. As per direction of Engineer-In-Charge.
Charges of Dismentaling of transformer from plinth, opening of all connections, circuits with help of required T&P of 400 KVA. Transformer. As per direction of Engineer-In-Charge.
Charges of Dismentaling of transformer from plinth, opening of all connections, circuits with help of required T&P of 500 KVA. Transformer. As per direction of Engineer-In-Charge.
Charges of Top up of oil including replacement of LT/HT bushing /bushing rod and gasket including opening of top cover of transformer and refixing of 250 KVA, as per direction of Engineer-In-Charge.
Charges of Top up of oil including replacement of LT/HT bushing /bushing rod and gasket including opening of top cover of transformer and refixing of 400 KVA, as per direction of Engineer-In-Charge.
Charges of Top up of oil including replacement of LT/HT bushing /bushing rod and gasket including opening of top cover of transformer and refixing of 500 KVA, as per direction of Engineer-In-Charge.
Charges of Inspection of transformer body leakeage and repairing of that by Oxy-accetelne gas welding afer lift up of core and drainage of oil and refixing of 250 KVA as per direction of Engineer-In-Charge.
Charges of Inspection of transformer body leakeage and repairing of that by Oxy-accetelne gas welding afer lift up of core and drainage of oil and refixing of 400 KVA as per direction of Engineer-In-Charge.
Charges of Inspection of transformer body leakeage and repairing of that by Oxy-accetelne gas welding afer lift up of core and drainage of oil and refixing of 500 KVA as per direction of Engineer-In-Charge.
Charges of Mounting of Transformer on plinth and LT/HT connections and balancing of load on all three phases and missing current flowing through nutral upto minimum permission limit of 250 KVA as per dirrection of Engineer-In-Charge.
Charges of Mounting of Transformer on plinth and LT/HT connections and balancing of load on all three phases and missing current flowing through nutral upto minimum permission limit of 400 KVA as per dirrection of Engineer-In-Charge.
Charges of Mounting of Transformer on plinth and LT/HT connections and balancing of load on all three phases and missing current flowing through nutral upto minimum permission limit of 500 KVA as per dirrection of Engineer-In-Charge.
Charges for fabrication of MS angle, as per direction of Engineer in charge.
Charges for fabrication of fuse set by M.S. angle 65x65x6mm and GI strip as per requirment.
Charges of Replacement of L.T. Cable 630 mm/400 mm incduing crimping of Aluminium Lugs.
Charges for providing and fixing of breather assembly with fresh Silica gel as per direction of Engineer-In-Charge.
Charges for providing and fixing of chemical earthing (3 mtr long) electrod including fixing of G.I. Strip after cutting/drilling for nuetral and body as per direction of Engineer-In-Charge.
Charges for replacement of 11KV Jumper at double pole structure.
Annexure - B ( Supply )
Supply of Alluminium Lugs 630 MM. ( As per sample ) Sample may be seen at JE Store Rudrapur
Supply of Alluminium Lugs 400 MM. ( As per sample ) Sample may be seen at JE Store Rudrapur
Supply of synthetic rubber ball for HT bushing
Supply of Clamps for Fuse Set. ( As per sample ) Sample may be seen at JE Store Rudrapur
Supply of all strip for LT bushing (80x200x8) mm
Supply of Gasket as per standards (neo k tex type or similar)
Supply of H.T. side porceleain/Epoxy Bushing 17.5 KV.
Supply of H.T. Bushing Rod (brass) ( As per sample) Sample may be seen at JE Store Rudrapur
Supply of arcing horn.
Supply of L.T. Bushing rod for 250 KVA T/F (Complete set) (As per sample) Sample may be seen at JE Store Rudrapur.
Supply of L.T. Bushing rod for 400 KVA T/F (Complete set) (As per sample) Sample may be seen at JE Store Rudrapur.
Supply of L.T. Bushing rod for 500 KVA T/F (Complete set) (As per sample) Sample may be seen at JE Store Rudrapur.
UTTARANCHAL ENTERPRISES
J AND J COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .