Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC | ₹16.2 L Quoted ₹20.1 L | L1 | Accepted-AOC BEING L1 AND REASONABLE |
| 2 | L2₹23.9 LRejected-Finance C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | ₹23.9 L | L2 | Rejected-Finance BEING OTHER THAN L1 |
| 3 | L3₹27.9 LRejected-Finance WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | ₹27.9 L | L3 | Rejected-Finance BEING OTHER THAN L1 |
| 4 | L4₹30.7 LRejected-Finance 164 ASRAF KHAN CHAWANI OPP HARTMAN COLLEGE BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | ₹30.7 L | L4 | Rejected-Finance BEING OTHER THAN L1 |
| Sl No | Description | Qty | Unit | N S ELECTRICALS L3 | D K THUKRAL AND SONS L2 | S.S.ENTERPRISES L1 | indiatraders L4 |
|---|---|---|---|---|---|---|---|
| 1.00REPAIR TO DESERT COOLER (Summer King/AVIN/SummerCool/Khaitan /ANY OTHER MAKE) | |||||||
| 2.00 | Disconnection, taking down desert coolers from any floor of building and cleaning /removing of old paint and painting with two coat of enamelled paint of colour as specified by Engr in charge over a coat of red oxide and internally with black bitumenous paint complete all as specified and directed. | 600 | Each | 50 ₹30,000 | 80 ₹48,000 | 5 ₹3,000 | 50 ₹30,000 |
| 3.00S&F in repair of following spares parts of desert coolers of different sizes including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed. | |||||||
| 4.00 | S& F Desert cooler body fabricated with 20 mm gauge metallic sheet of GI with side grills filled with wood wool pads , front grill and equiped with one piano switch, selector switch, PVC distributors and PVC pipes complete all as specified and directed. | 55 | Each | 2,600 ₹1.4 L | 3,400 ₹1.9 L | 2,000 ₹1.1 L | 2,800 ₹1.5 L |
| 4.01 | S & F Electric Fan motor exhaust exhaust fan turbo force 450 mm sweep type heavy duty of Desert/air cooler of capacity 1300-1400 RPM single shaft of power rating 100 - 150 watt 230 Volt 50 Hz Single phase Make- Summerking/Summercool/Khaitan | 200 | Each | 850 ₹1.7 L | 950 ₹1.9 L | 1,200 ₹2.4 L | 1,050 ₹2.1 L |
| 5.00 | S& F Electric Fan motor of Desert/air cooler of capacity 1300-1400 RPM single shaft of power rating 100 - 150 watt 230 Volt 50 Hz Single phase Make- Summerking/Summercool/Khaitan complete all as specified and directed. | 400 | Each | 450 ₹1.8 L | 750 ₹3 L | 800 ₹3.2 L | 550 ₹2.2 L |
| 6.00 | S& F Water lifting submersible type tullu pump 18 watt and water lifting upto 1.8 Mtr for desert coolers Make- Summerking/Summercool complete all as specified and directed. | 600 | Each | 120 ₹72,000 | 95 ₹57,000 | 90 ₹54,000 | 90 ₹54,000 |
| 7.00 | S& F Float valve plastic ball for 15 mm dia bore of pipe of desert cooler with ISI mark complete all as specified and directed. | 45 | Each | 70 ₹3,150 | 50 ₹2,250 | 10 ₹450 | 50 ₹2,250 |
| 8.00 | S& F PVC stop cock suitable for 15 mm dia GI pipe ISI Mark complete all as specified and directed. | 40 | Each | 50 ₹2,000 | 30 ₹1,200 | 10 ₹400 | 60 ₹2,400 |
| 9.00 | S& F PVC connection 15 mm dia with CP nut 450 mm long ISI Mark complete all as specified and directed. | 50 | Each | 40 ₹2,000 | 40 ₹2,000 | 20 ₹1,000 | 25 ₹1,250 |
Updated dates
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Jan 2026, 6:00 pmClosed
GE (WEST) BAREILLY
GE WEST BAREILLY
REPAIR/MAINT OF SUMMER APPLIANCES AT VARIOUS LOCATIONS UNDER GE (WEST) BAREILLY.
2025_MES_743645_1
8287/C/E
Open Tender
Electrical and Maintenance Works
180 days
GE (WEST) BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) BAREILLY
₹80,000
Yes
2 Mar 2026
8 Dec 2025
7 Jan 2026
8 Dec 2025
5 Jan 2026
23 Dec 2025
Amount
REPAIR TO DESERT COOLER (Summer King/AVIN/SummerCool/Khaitan /ANY OTHER MAKE)
Disconnection, taking down desert coolers from any floor of building and cleaning /removing of old paint and painting with two coat of enamelled paint of colour as specified by Engr in charge over a coat of red oxide and internally with black bitumenous paint complete all as specified and directed.
S&F in repair of following spares parts of desert coolers of different sizes including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed.
S & F Electric Fan motor exhaust exhaust fan turbo force 450 mm sweep type heavy duty of Desert/air cooler of capacity 1300-1400 RPM single shaft of power rating 100 - 150 watt 230 Volt 50 Hz Single phase Make- Summerking/Summercool/Khaitan
S& F Electric Fan motor of Desert/air cooler of capacity 1300-1400 RPM single shaft of power rating 100 - 150 watt 230 Volt 50 Hz Single phase Make- Summerking/Summercool/Khaitan complete all as specified and directed.
S& F Water lifting submersible type tullu pump 18 watt and water lifting upto 1.8 Mtr for desert coolers Make- Summerking/Summercool complete all as specified and directed.
S& F Float valve plastic ball for 15 mm dia bore of pipe of desert cooler with ISI mark complete all as specified and directed.
S& F PVC stop cock suitable for 15 mm dia GI pipe ISI Mark complete all as specified and directed.
S& F PVC connection 15 mm dia with CP nut 450 mm long ISI Mark complete all as specified and directed.
S& F Capacitor 4 MFD of make Usha/Asain/Epcos/ISI complete all as specified and directed.
S& F Set of legs with clamp and nut bolt & washer for mounting of fan motor on body for desert cooler complete all as specified and directed.
S& F Aluminium Fan leaf blade complete all as specified and directed.
S& F PVC fan leaf blade complete all as specified and directed.
S& F Iron Stand made out of angle iron of each size 35x35x4mm for installation of desert cooler of height 3 to 6 feet, lengthxwidth as per site requirement on the ground floor,/Ist /2nd floor complete all as specified and directed.
S& F Switch regulator with controlling knob low med high control of any size complete all as specified and directed.
S& F Wire mesh of Pannel doors/side grills for supporting of Wood wool grass pad of size as required at site as per panell door size complete all as specified and directed.
S& F PVC water distributor heavy duty 15mm size fixed with bolts & Nut & washers complete all as specified and directed.
S& F PVC elbow 15mm dia for inside water distribution complete all as specified and directed.
S& F Front grill suitable for desert coolers complete all as specified and directed.
S& F Plug top 3 pin 5/6 Amps, 230 Volt complete all as specified and directed. Make: Anchor/Schenider/Havells
S& F Piano type switch 5/6 Amps, 230 Volt complete all as specified and directed. Make: Anchor/Schenider/Havells
S& F Flexible Copper Cable 2 Core multistranded, PVC insulated of size 70/.0076 for internal wiring of desert cooler complete all as specified and directed. Make: Plaza/Havells/polycab
S& F Two core connection lead cable, PVC insulated and sheathed Copper cable size 1.5 Sqmm complete all as specified and as directed Make: Plaza/Havells/Polycab
S& F PVC flexible water tubing pipe of 15 mm dia heavy duty for desert cooler inside water distributing complete all as specified and directed.
S& F GI Water tubing medium grade of bore dia 15 mm with all fittings for connection of Desert cooler water pipe line including fixing with clamp and fiitings complete all as specified and directed.
S& F GI sockets/union/elbow/tee of size 15 mm complete all as specified and directed.
REPAIR OF WATER COOLER 80/40,60/120,150/150, 150/180, LTR (Bluestar/Voltas /USHA/ANY OTHER MAKE)
S& F Maintenance/ Servicing of water coolers 40/80/,60/120,150/150,150/180 Ltrs Capacity by removing , cleaning the dust and dirt and mud from water storage tank and tray and from the complete unit, cleaning of water tank, cleaning of condensing coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed.
S& F Taking down/out by cutting unserviceable compressor unit from the machine of size 180/150/120/60/80/40 and of differnt capacity ltrs capacity including flushing out/cleaning of refrigerator system by CTD/Nitrogen gas complete all as specified and directed.
S&F compressor (sealed unit) with charging of refrigerant gas complete and testing on full load. for following capacity in Water Cooler all as specified and as directed by Engineer-in-Charge complete all as specified and directed.Make:LG/Emerson
S& F 180/150 ltrs capacity of water Cooler complete all as specified and directed.
S& F 60/120 ltrs capacity of water Cooler complete all as specified and directed.
40/80 ltrs capacity of water Cooler
S&F in repair of following spares parts of water cooler of 40/80/,150/180, 120/160 Ltrs Capacity including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed.
S& F Capacitor 36 MFD, complete all as specified and directed. Make-Asian/Epcos/Siemns/ISI
S& F Capacitor 10 MFD complete all as specified and directed. Make-Asian/Epcos/Siemns/ISI
S& F Starting capacitor 80/100 Mfd of complete all as specified and directed. Make Unistar/Usha/Asian/ISI
S& F Thermostat switch assly of suitable size complete all as specified and directed. Make - Indfoss/classic/danfoss
S& F Overload protector Relay for water cooler of makes as above complete all as specified and directed. Make - Indfos/classic/ danfoss
S& F Blower motor 1/5 HP with mounting stand for water cooler of different capacity for water coolers complete all as specified and directed.
S & F Fan leaf blade of blower motor for water cooler of different capacity for water coolers complete all as specified and directed.
S& F Float valve complete with PVC ball and brass spindle for size 15 mm bore of pipe in water coolers of makes as above complete all as specified and directed.
S& F PVC connection with brass union nut 450 mm long suitable for 15 mm GI pipe in water coolers of makes as above complete all as specified and directed.
S& F Push cock (Push Tap) cast copper alloy chromium plated heavy duty complete of size 15 mm of suitable type as per site requirement complete all as specified and directed.
S& F Drain pipe flexible including clamp for water cooler after repair of leakage of water tray complete all as specified and directed.
S& F Plug top 3 pin 15 Amps, 230 Volt complete all as specified and directed. Make: Anchor/Schenider/Havells
S& F Supply and fixing of Connection Pipe and socket for connection of Water cooler from Aquaguard /water purifier complete all as specified and as directed.
S& F Repair to top cover of water cooler including replacement of rubber Gasket and locks complete including replacement of old nut and bolts, screws, hinges etc. complete all as specified and directed.
S& F Repair to body of water cooler including water tray of any make/size capacity by welding of MS sheet not less than 1.6 sqmm thick to match with existing after removing old rusted/unserviceable portion including painting and replacement of old nut and bolts, screws, hinges etc. complete all as specified and directed.
M&L for removing of dents, putty filling, spray painting with two coats of synthetic enamelled paint after preparation of surfaces by burning of old paint for water cooler of 180/150/120/60/80/40 ltrs capacity for makes as above complete all as specified and directed.
Repair to Split Type/Window Type AC 1/1.5/2.0 TON Make : (Carrier/LG/Haier/Hitachi/Bluestar/Samsung/Panasonic/videocon/Voltas)
Maintenance and Servicing of split type air conditioner of capacity 1.5/2.0 TR of any make and type by removing , strip opening, cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensing and cooling coil and complete outdoor and indoor unit using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing of blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed.
Maintenance and Servicing of Window type air conditioner of capacity 1.0/1.5/2.0 TR of any make and type by removing , strip opening, and taking out the window type AC from the cabinet frame and cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensing and cooling coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing of blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed.
Taking down/out unserviceable sealed/rotary/Reciprocating type compressor unit from the outdoor unit of Split type AC/ Window type ACs of makes-Carrier/LG/haier/blue star/Voltas and any other make of capacity 1/1.5/2.0 Ton capacity including flushing of cooling system by Nitrogen gas complete all as specified and directed.
compressor (sealed unit) of following capacity in Split type/window type Air Conditioner complete and testing on full load complete all as specified and directed. Make:LG/Hitachi/Emerson/Carrier
(a) Reciprocating type 1.5 Ton complete all as specified and directed.
(b) Reciprocating type 2.0 Ton complete all as specified and directed.
(c) Rottery type 1.0 Ton complete all as specified and directed.
(d) Rottery type 1.5 Ton complete all as specified and directed.
(e) Rottery type 2.0 Ton complete all as specified and directed.
Supply, fixing , installation ,commissioning and testing of indoor unit complete with remote and valves of capacity 1.5 TR suitable for fixing up in the existing model of outdoor unit of Split ACs complete after disconnecting electrical connection and dismantling/ taking out indoor unit of split type ACs of any make and capacity from any place and fixing of the same after recharging of refrigerant gas including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge complete all as specified and directed. Make: LG/Voltas/Carrier/Bluestar/Hitachi/Samsung
Ditto- all as above but of indoor unit capacity 2.0 Ton complete all as specified and directed.
S&F in repair of following spares parts of Split type/Window type ACs of capacity 2.0/1.5/1.0 Ton including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed.
S& F Remote suitable for various makes of Split type/Window ACs for 1/1.5/2.0 Ton capacity complete all as specified and directed. Make: LG , Carrier, Voltas, Bluestar, Hitachi
S& F Condenser motor of outdoor unit for 1.5/2.0 Ton capacity of AC as per existing makes complete all as specified and directed.
S& F Indoor motor of Blower for 1.5/2.0 Ton capacity of split AC as per existing makes complete all as specified and directed.
S& F Condenser PVC blade of fan motor for 1.5/2.0 Ton Split AC complete all as specified and directed.
S& F SP plug and socket in sheet steel enclosure including SP MCB 32 Amps complete all as specified and directed. Make : HPL/Havells/L&T
S& F Running capacitor 50/2,/50/6 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs complete all as specified and directed.
S& F Running capacitor 45 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs complete all as specified and directed.
S& F Starting capacitor 100/120 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs complete all as specified and directed.
Indoor capacitor of size 1.5 MFD/2 MFD suitable for 1.5/2.0 Ton AC complete all as specified and directed.
S& F Swing motor suitable for indoor unit of 1.5/2.0 Ton Split type AC complete all as specified and directed.
S& F Contactor suitable for 1.5/2.0 Ton AC as per make/size approved by Engr-in-Charge complete all as specified and directed. L&T/C&S/SIEMENS
S& F Copper tubing of size 3/8" including cutting and brazing all as directed by Engr-in-Charge complete all as specified and directed.
S& F Copper tubing of size 5/8" including cutting and brazing all as directed by Engr-in-Charge complete all as specified and directed.
S& F Copper tubing of size 1/4" including cutting and brazing all as directed by Engr-in-Charge complete all as specified and directed.
S& F Copper tubing of size 1/2" including cutting and brazing all as directed by Engr-in-Charge complete all as specified and directed.
S&F three core connection lead two single core, PVC insulated and sheathed Copper cable size 2.5 Sqmm including one earth wire of full guage complete all as specified and as directed complete all as specified and directed. Make : Plaza/Havells/Polycab
S&F Nitril vinyl insulation foam suitable for fixing with copper tube of size 3/8", 5/8" , 1/2" and 1/4" and packing with wide pvc tapes of black/white colour compete all as specified and directed.
S& F Reverse valve suitable for 1.5/2 ton ACs including dismantling and reinserting of valve and refilling of reqd refrigerant and testing all as specified and directed by Engr-in-Charge
S& F Wall/floor mounting type iron stand for outdoor unit complete all as specified and as directed
S& F Dead plug made out of brass of sizes 5/8" ,3/8" , 1/4" & 1/2" as per requirement on site for outdoor unit valves complete all as specified and directed.
S& F Pin Valve made out of brass for compressor of Acs complete all as specified and directed.
S& F Brass Thimble/U clip lugs made out of brass for internal connection & wiring of ACs of 100 pcs per Pkt complete all as specified and directed.
S& F Suction valves made out of brass of size 5/8"/1/2"/3/8"/1/4" as per required for outdoor unit of split type Acs complete all as specified and directed.
S& F Discharge valves made out of brass of size 5/8"/1/2"/3/8"/1/4" as per required for outdoor unit of split type Acs complete all as specified and directed.
S& F Blower complete with fins suitable for indoor unit of Split type AC complete all as specified and directed.
S& F Metal clad socket of 20 Amps 240 volts for AC complete all asspd and directed. complete all as specified and directed. Make:Havells/Schneider/Anchor/L&T
S& F Metal clad Plug top of 20 Amps 240 volts for AC complete all asspd and directed. Make:Havells/Schneider/Anchor/L&T
S& F Electronic PCB card complete with Display and sensor complete for split AC indoor unit of any make as per requirement at site complete all as specified and as directed. Make: LG, Carrier, Voltas, Bluestar,Hitachi
S& F Display unit with sensor complete for split AC indoor unit of any make as per requirement at site complete all as specified and as directed. Make: LG, Carrier, Voltas, Bluestar
S& F Unplasticised PVC pipes 25 mm outer dia of pressure rating 100 Kg/Cm2 for drain of water of split type ACs fixed complete to walls,ceilings or in floors etc, including chase cutting on wall & making good as per existing complete all as specified and as directed.
S& F Air dust filter for indoor unit of Split type ACs for 1.5/2.0 Tonne capacity of Acs complete all as specified and directed.
S& F Relay for 1.5/2.0 Ton of makes Classic/Indfos/Annapurna for Split/window ACs complete all as specified and directed.
S& F Thermostat Switch for 1.5/2.0 Ton of makes Classic/Indfos/Annapurna for window ACs as makes above complete all as specified and directed.
S& F Air dust filter for window type ACs for 1.5/2.0 Tonne capacity of ACs as per makes above complete all as specified and directed.
S& F Switch Controlling Knob complete with high low med function for 1/1.5/2.0 Tonne capacity of window type Acs complete all as specified and directed.
S& F Condenser motor for 1/1.5/2.0 Ton capacity of window type AC as per site requirementcomplete all as specified and directed.
S& F Condenser PVC round Fan Blade for 1/1.5/2.0 Ton window type AC Make : Carrier/LG/Bluestar /Videocon/Onida/Samsung complete all as specified and directed.
S& F Front grill suitable for 1.5/2.0 Ton window type AC complete all as specified and directed Make : Carrier/LG/Bluestar /Videocon/Onida/Samsung
S& F MCB SP 32 Amps 230 Volt used in the DB/MCB Enclosure Box of ACs complete all as specified and directed.
S& F MCB SP 25 Amps 230 Volt used in the DB/MCB Enclosure Box of Acs complete all as specified and directed.
Supply and gas charging with refrigerent gas required in any make and type of split and window type ACs to its full capacity where less gas detected in the split type and window type air conditioners complete all as specified by Engr in charge
S& F Taking down unserviceable PCBs card with sensors of Split/Window type AC and refix the same after complete repair and testing as of Cap 1.5/2.0 ton as directed by Engr-in-charge.
Taking down unserviceable condensor coil from outdoor unit of Split AC or from Window type ACs and Supply & Fixing and installation of condenser coil by brazing and testing complete by refilling the refrigerant gas after flushing with nitrogen gas complete all as directed by Engr-in-charge.
Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out indoor and outdoor unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge.
S& F Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out window type air conditioning complete with frame cabinet of any make and capacity from any place and installation, commissioning and testing to another location including transportation cutting of hole on wall and making platform complete with wooden strip/iron frame for fixing of Window AC Cabinet and making good of disturbed surface with matching colour/distampercomplete all as specified and directed.
S& F REPAIR OF VOLTAGE STABILIZER 1/2/3/4/ 5 KVA (Bluebird/Blueline/Sinetrac/Vintec/ANY OTHER MAKE)
S& F Opening/ stripping of voltage stablizer of capacity ranges 1 to 5 KVA make- Bluebird/Bluline/Sinetrac/Vintec/ V Guard/any other make for checking of components for their serviceablity as per makes above and repair to its internal circuits and wiring including minor repair to circuit plate and refix to its original position all as specified and directed
All as Per Srl Item No 111 above here-in-before but for capacity 7.5 KVA complete all as specified and directed.
S& F Rewinding of main transformer with super enamelled coper wire of suiltable size or guage including insulation material applying varnish and drying properly at slow temprature, , replacing nut bolts with washer including removing of burn wire of voltage stablizer single phase 220 V of 1 to 2 KVA complete all as specified and directed.
All as Per Srl Item No 113 above but for 3 KVA.
All as Per Srl Item No 113 above but for 4 KVA.
All as Per Srl Item No 113 above but for 5 KVA.
All as Per Srl Item No 113 above but for 7.5 KVA.
S&F in repair of following spares parts of Voltage stabilizer single phase of cap 2/3/4/5/7.5 KVA including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed.
S& F Trigger transformer of suitable for 2 to 3 KVA complete all as specified and directed.
S& F Trigger transformer of suitable for 4 to 7.5 KVA complete all as specified and directed.
S& F Circuit Plate 2 to 7.5 KVA complete all as specified and directed.
S& F Volt Meter indicating 100 to 300 volt make AE for stabilisers as per make above complete all as specified and directed.
S& F Time Delay Relay System for 2 to 3 minutes with high cut above 250 volt and low cut 190 V in 2 to 7.5 KVA V/stablizer complete all as specified and directed.
S& F Circuit jack/ST3 socket for in out connection platecomplete all as specified and directed.
S& F Walk-in Coolers & Mortury cabinets MAKE :Bluestar/ANY OTHER MAKE
S& F Maintenance/Servicing of Walk-in- cooler/Mortuary Cabinet of any size and type by removing , cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, cleaning of condensing coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed.
S&F in repair of following spars parts of Walk-in Coolers cold storage and mortury cabinets of different sizes including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed.
S& F Compressor (sealed unit) of cap 1.5/2.0 Ton/ esixting capacity in mortury cabinet/walk-in coolers cold storage complete and testing on full load all as specified and as directed complete all as specified and directed.
S& F Electric blower motor of Walk-in Cooler cold room/mortuary cabinet for indoor blower unit of existing make and capacity complete with grills complete all as specified and directed.
S& F Contactor switches of suitable sizes for outdoor units of walk-in coolers and mortury cabinets complete all as specified and directed.
S& F Running capacitors of sizes 50/6 MFD for outdoor units complete all as specified and directed.
S& F Indoor motor capacitors complete all as specified and directed.
S& F Sub Zero Temperature Controller for Walk-in- Cooler Cold Storage complete all as specified and directed. Make -Danfoss/Thermo Sensors
S&F in repair of Mortuary Cabinet door handles with locks complete of existing makes and sizes and repair of dents and rusting in the mortury cabinet and testing complete re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed.
M&L for repair of floor of walk-in cooler cold room by using suitable metallic flooring sheets and welding works and insulation thermocol materials works and refixing of matting and repair of dents and rusting complete all as specified and directed for proper cooling and smooth functioning complete all as specified and directed.
M&L for repair of door locks, handles and hinges of walk-in cooler cold room complete all as specified and directed.
S& F Repair of PCB circuit plate including display card sensor & switches by disconnecting and refixing the same after complete repair and testing of walk-in cooler cold room by using suitable cement works and refixing of metallic flooring and repair of dents and rusting including repair of door locks complete all as specified and directed for proper cooling and smooth functioning complete all as specified and directed.
REFRIGERATOR 320/310/280/215/180/185/165 LTR MAKE: LG/GODREZ/Whirlpool/Kelvinator ANY OTHER MAKE
Repair and Maintenance of refrigerator of Capacity 165 to 400 Ltrs by removing ,strip opening, cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, re-assembling,dismantling the unserviceable parts & re-installing in the original position after replacement of U/S parts and testing for proper cooling and smooth functioning complete all as specified and directed. Make-LG/GODREZ /Samsung/Voltas/Whirlpool/any other make
Repair and Maintenance of deep freezers 310/320 Ltrs by removing , cleaning the dust and dirt from the complete unit, defrosting and cleaning of cabinet, cleaning of condensing coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing condenser fan motor etc re-assembling, re-installing in the original position after replacement of U/S parts and testing and testing for proper cooling and smooth functioning Make-LG/Samsung/Voltas/Bluestar any other make
Taking down by cutting unserviceable Sealed/ rotary compressor unit from the refrigerator/deep freezer machine of size 310/320/300/280/215/170/165 litres capacity of MAKE LG/GODREZ /Whirlpool/ANY OTHER MAKE including flushing out refrigeration system such as condensor tubing capillery evaporator by nitrogen gas complete including cleaning complete all as specified and directed.
S&F compressor (sealed unit) for following capacity in Refrigerators/Deep Freezers complete and testing on full load after reharging of refrigerant all as specified and as directed by Engineer-in-Charge Make: LG/Samsung/Voltas/Whirlpool/Bluestar a
S& F 350/400/500 ltrs capacity deep freezers complete and testing on full load complete all as specified and directed.
S& F 310/280 ltrs capacity refrigerators/deep freezers complete and testing on full load complete all as specified and directed.
S& F 215 ltrs capacity Refrigerators complete and testing on full load complete all as specified and directed.
S& F 180/165 ltrs capacity Refrigerators complete and testing on full load complete all as specified and directed.
Supply and gas charging with refrigerent gas used for any type and make of water coolers, refrigerators, deep freezers,walk-in cooler/mortury cabinets to its full capacity where less gas detected in the Water coolers,deep freezers, refrigerators and walk-in-coolers/cabinets complete all as specified by Engr in charge
S&F in repair of following spares parts of refrigerators/deep freezers of different sizes including testing complete after dismantling of old respective unserviceable spares complete all as specified and directed.
S& F Thermostat switch suitable different capacity refrigerator complete all as specified and directed. Make: LG/Whirlpool/Samsung
S& F Relay & Overload assembly universal type/Chip type complete suitable for all type of Refrigerators as per the existing model/size.complete all as specified and directed.
S& F Freezer with door of suitable make and size as per the existing model/size complete all as specified and directed.
S& F Cooling coil cabinet complete for refrigerators of suitable make and size as per the existing model/size.complete all as specified and directed.
S& F Door light switch (push button type ) with lamp holder of any make and size as per the existing model/size.
S& F Electric blower fan motor of existing capacity in deep freezers complete all as specified and directed.
S& F Electric bulb 15 watt 250 V AC or pin type of make Philips or equivalent complete all as specified and directed complete all as specified and directed.
S& F Evaporator/condenser coil assembly for capacity 165 to 310 Ltrs including brazing and fixing and testing complete all as specified and directed.
S& F Capillary 0.33 mm dia of brass including brazing and fixing and testing complete all as specified and directed.
S& F Magnetic door gasket/rubber beading for capacity 165 to 310 Ltrs complete all as specified and directed.
S& F Taking down unserviceable PCBs card with sensors of Refrigerators of inverter model or any make and type and refix the same after complete repair and testing complete all as specified and directed.
M&L for sub main wiring with two single core 4.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 4.0 sqmm (FRLS) and one run of 4.0 sqmm (FRLS) copper conductor shall be measured as one unit length.)
Notes:- 1.The time limit for attending the job/complaints complaints within 24 hour. 2 In case the contractor fails to attend/rectify the defects within the above time limit i.e 24 Hrs (excluding reapair of Electronic PCB cards and replacement of compressor in which a specified time duration of 3 days required) penalty will be imposed as under :- Rs 200/- per day per complaints for first seven days after that Rs 500/- per day per complaint. 3. The representative of contractor shall report to the E/M refrigeration Sec complaint cell on all working days to receive the complaints. 4. A register shall be maintained by the contractor/his Rep to record the complaints and its progress. 5. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge. (6) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
D K THUKRAL AND SONS (BID ID -3509868)
N S ELECTRICALS (BID ID -3506570)
indiatraders (BID ID -3516570)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
BOQ_832674.xls
BOQ • 1.20 MB
completetender8287.pdf
Tender Documents • 1.52 MB
Download all tender documents and submit your bid