Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹46.8 L+₹3.5 L (7.96%)Rejected-Finance BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹47.2 L+₹3.8 L (8.78%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Jun 2022, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR AND MAINT OF DISTRIBUTION SYSTEM AND ALLIED WORK, PUMPING SET OF DIFFERENT CAPACITY, CHLORINE OR DOSING PLANT AND ALLIED WORK UNDER GE (E) BAREILLY.
2022_MES_527921_1
8202/E8
Open Tender
Civil Works
Item Rate
183 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹98,000
Yes
18 Aug 2022
2 Jun 2022
2 Jul 2022
2 Jun 2022
30 Jun 2022
16 Jun 2022
2 Jun 2022 - 9 Jun 2022
Amount
Lifting/taking out defective submersible pump of any capacity alongwith column pipe of any size and submersible cable , dismantling the pump from motor, setting aside for repair /servicing / overhauling including lowering the pump set into borewell replacement of packing and nut bolts (if required) and testing after the completion of repair works in the presence of Engr in charge.
Rewinding to submersible pump 50 HP of any make with super enameled copper winding wire PVC coated 2 mm thick as per taken out qty, Providing PVC separators, PVC sleeves & jointing compound complete all as specified and directed. Note :- Rewinding, replacement items will be measured and paid seprately under relevent item.If the same motor copper winding wiring burnt second time in the above CA Period, The contractor is responsible to paid and rewind the same at their own cost.
All as per Srl item No 02 here in before but capacity 41 Hp
All as per Srl item No 02 here in before but capacity 10/15Hp
All as per Srl item No 02 here in before but capacity 5/7.5Hp
Repair/Replacement of following parts of the submersible pump and motor for capacity 40/41/50 HP of original company as approved by GE. Make : KSB, Crompton, Kirlosker
Thrust bearing plate made out of carbon for submersible motor
Gun metal bush for submersible motor
Shaft sleeve made out of stainless steel for submersible motor
Clamp stud for submersible motor
Rotor balancing of submersible motor
Shaft grinding of submersible motor
GM Neck Ring for submersible pump
Stainless steel sleeve for submersible pump
Stainless steel pump shaft for submersible pump
Stainless steel impeller for submersible pump
Cast iron bowl for submersible pump
Rubber bush for submersible pump
M&L for Painting to pipe of pump house rising mains hydrants, sluice valves, pipe, fittings, NRV, discharge head etc after cleaning, scrapping and making the surfaces free from rust of main externally and painting with two coats synthetic enamelled paint in black/ blue/ red including marking/ writing on pipe etc complete as specified and directed
S&F in repair electric shock treatment chart coloured of size approximetely 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete all as specified and directed.
S&F in repair machinary maintenance chart coloured of size approximately 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete all as specified and directed.
M&L for trimming vegetation or small inequalities clearing all grass vegetation, saplings, shrubs, brushwood, roots, and tree of surroundings area up to 500 sq mtr including cleaning and removing rubbish upto a distance of 50 mtr outside the periphery of the area under clearance of water supply installations complete all as specified and as directed.Note-trimming will be done two times during contrct period at all installations of water supply. etc complete as specified and directed
S&F in repair for Aviation light on OH tank 18/21 mtrs staging (on top of OH tank) with all fittings, fixtures,and accessories including 2.5 sqmm wire, three core through and including 20 mm PVC conduit from light to connection points, and also including 2-way MCB DB with isolator (10 Amp) capacity complete all as specified and directed.
Supplying, Laying, jointing and testing 2.5 Sq mm 2 core, PVC insulated, armoured, heavy duty, Copper conductor cable 1100 volts grade, laid in trenches/ducts, floors, fixed to pole/ walls etc. complete all as specified and directed.
S&F in repair for glow sign board (box type) LED of required size 600 x 600 mm made out of MS sheet of suitable size with sheet fixed on front and quality marked with details of Pump House etc on front and rear with different colours including provision of LED power- fittings & fixtures in equal distance to illuminate board including connections with 2.5 sqmm single core stranded copper conductor cable and writing with 10 mm size letters as specified and directed .
Supply & fix in repair 1100 volts grade heavy duty cable PVC insulated aluminum conductor screenedserved with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm GI suspension wire, one twin core cables flat or circular of size 10 Sqmm etc complete all as specified and directed.
S&F in repair Off load change over switch 200 Amp, 4 pole 415 Volt, etc. complete all as specified and directed
Supply and fix in repair energy saving and environemntal friendly long life versatile pressure die-cast aluminium IP-65 roadway luminaire 72 W LED fitting with high power LEDs light source and electronic driver etc complete as specified and directed
S&F in replacement new generation post top energy saving environment friendly, long aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with power LED,s of 35 Watt as light source of 35 Watt suitable for pole dia 76 mm of complete all as specified and directed
S & F in replacement of street light brackets 40 mm bore GI pipe medicum grade upto 1.5 mtr long bend to shape including flat iron clamps and sutable nuts and bolts etc complete all as specified and directed
M&L in replacement of PVC insulated single core multistranded copper cable of size 1.5 sq mm unsheathed 1100 volts grade drawn through conduit / cassing capping on surface / pole /wall concealed and making good of disturbed surface including taking down unserviceable wire etc complete all as specified and directed
S&F Bldg Security light energy efficient 1X20 Watt LED 6K Endura cityliner leaf (with Toughned glass) die cast aluminium and fixing arrangement of fitting including 1 mtr 35/50mm GI 90 degree bend pipe complete all as specified. (Make: Havells cat No; LHETBXU7PA6S025 equivalent cat part in Philips /Bajaj /CG)
M&L earthing complete with GI earth plate electrode of size 60cm x 60cm x 6.0mm thick burried directely in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate at a depth not less than 1.5m below normal ground level connected to and including earth lead of GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI and connected to Earthing test point and earth dolly all as shown in elect plate No 3 SSR Pt-I including all necessary excavation earth work, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40mm dia protection pipe and 20mm dia watering pipe and wire mesh funnel etc complete all as specified and as directed.
Supply & replacement of Contactor ML-3, suitable to operate 35-45 HP submersible pumping set Cat part No SS-90721 Make-L&T or equivalent to approved make as specified in CA.
Supply & replacement of Contactor ML-4, suitable to operate 50-60 HP submersible pumping set Cat part No SS-90910 Make-L&T or equivalent to approved make as specified in CA.
M&L for cleaning of RCC Over Head Tanks capacity 1 lakh gallon and removing and taking out sand, sludge and mud etc including disposal of the same at a distance not exceeding 100 mtrs from the tank,including two coats of whitewash on whole internal walls of OH Tank all as directed. NOTE:-All the safety equipments for workers working on OHT and U/G Sumps will be provided by the contactor.Cleaning of OH tank is in every 6 month or contracor is responsible to clean all OH tank two time in their contract at same cost quoted rate.
All as per Srl item No 24 here in before but capacity 50000 gallon.
All as per Srl item No 24 here in before but capacity 25000/35000 gallon.
Supply only Calcium based granularhypo chlorite 65% to 70% disinfectant for water treatment ,Packing in 45 KG ,plastic drums complete all as specified and directed .
M&L MCCB, 4 pole, 415 Volt, fixed type 125 to 160 amp with breaking capacity 36 Ka complete all as specified and directed.
M&L MCCB, 4 pole, 415 Volt, fixed type 160 to 200 amp with breaking capacity 35 kA complete all as specified and directed.
Repair and servicing of powder base vacuum type chloronome/dosing plant for smooth functioning including necessary spares as their own cost required for rectifying the defects to be included for smooth functioning the plants for the following plants :- Location :- Pump house No. 12, 25, 27, 28, 29, 30, 31, 32, 33, 34, 36, 37, 38, MH and swimming pool etc Note:- (i) For smooth functioning the complete spares plants and rewinding & repair of mixing motor has to concluded in the quoted rate. (ii) All testing equipments to be used in installations. (iii) Contractor should be well equiped with proper protection of chlorine gas and mask should be kept with all operators.
Taking out connection of Chlorine / Altoch dosing system , detecting fault and repair /replacement of unserviceable parts and refixing same after completion job and connecting dosing system and testing complete all as specified and directed. Make : Aquafit, Chloromax or equivalent as approved by GE. (NOTE:- Spares parts shall be measured and paid separately as Supply only as under)
Supply only rotor assembly with bearing brackets and tolerance rings suitable for decree dosing pump complete all as specified and directed.
Supply only pump tube suitable for dosing pump complete all as specified and directed.
Supply only injectior assembly suitable for dosing pump complete all as specified and directed.
Supply only duckwill suitable for dosing pump complete all as specified
Supply only diaphragm assembly suitable for dosing pump complete all as specified
Supply only weighted suction line stainer suitable for dosing pump complete all as specified and directed.
Supply only Agitator Motor electric driven 230 Volt 50 Hz,single phase, 120 W & 900 RPM copper wounded complete all as specified and directed.
Supply only PVC pipe as per existing size all as specified
S&F in repairs electronic timer type ST 100 suitable for operation on 415 volts 50 Hz for 3-30 Sec all as specified and as directed.
S&F in repairs electronic Single phase preventer operation on 415 volts 50 Hz all as specified and as directed.
Supply only grass and weeds killer chemical of make Roundup all as specified and directed.
S&F rubber mat of size 1.0mtr x 2.0mtr x 12 mm at installation of etc complete as specified and directed
S&F pressure gauge of dial 30 to 60 suitable for fixing at 100/150 header mm pipe with all fiting andf fixtures etc complete as specified and directed
S&F mini motor protection relay for 35-51hp submersibble motores of make L&T all as specified and directed.
Supply and fix in repair spare conntact kit for ML 3 contractor complete all as specified and directed .
Supply and fix in repair spare conntact kit for ML 4 contractor complete all as specified and directed.
S&F in replacement of PVC bib tap 15 mm bore etc complete as specified and directed.
M&L for dismantling of motor, 3 phase, 7.5 KW, taking out burnt winding wire from stator, cleaning all slots properly, repair of pump/rewinding the motor with proper guage of super enamelled winding wire and varnishing properly including baking and providing insulation and packing properly re-assembling the motor with pump and installed at its proper position and testing the same including connection plate etc complete as specified and directed.
M&L for dismantling of non clog type centrifugal pump set of capacity 12.5hp either fixed or floor or on trolley mounred and taling out unsv spares and performin following operation to complete the task:- (i) Rewinding of the motor centrifugal pumping set with insulated copper winding including sleeves as per original approved and replacement of worn out parts including griding of parts testing & transport charges complete all as specified and directed. (ii) replacement of motor bearing with lock nut -02 Nos (iii) Repalcement of fan motor-01 No (iv) Replacement of star coupling set with rubber-01 Each
Take the water sample from the bore well at Pump House No. 12, 25, 27, 28, 29, 30, 31, 32, 33, 34, 36, 37, 38, 41, 26, 20, 21, 22, 37 MH PH and two consumer end and send it for physical / Chemical / Bateriological test from any recognised govt agency (two times in contract period) and provide its report to Engr in charge.
S& F in replacement submersible pump / motor electric driven 415 Volts, TP suitable for 200/250 mm bore well casing pipe size 200/250 mm supply complete of 41 HP all as specified and directed.
S& F in replacement submersible pump / motor electric driven 230 Volts, SP suitable for 25 mm bore well casing pipe size 50 mm supply with staster complete of 01 HP all as specified and directed.Make Kirloskar/Cromption and Havells
S& F in replacement Pressure Booster Pump / motor electric driven 230 Volts , SP suitable for 20/25 mm bore with staster complete of 01 HP all as specified and directed.Make Kirloskar/Cromption and Havells
S& F in replacement HI Flow 1 HP Centrifugal pump / motor electric driven 230 Volts, SP suitable for 20/25 mm bore with staster complete all as specified and directed.Make Kirloskar/Cromption and Havells
Supply fixing testing and commissioning submersible cable flat 16 sqmm 3 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer foe every column pipe of 3 mtr lenght all as specified and directed.
Supply fixing testing and commissioning submersible cable flat 1.5 sqmm 2 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer foe every column pipe of 3 mtr lenght all as specified and directed.
Supply install in repair and commissioning of Granular chlorination dosing pump of high pressure single head gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U S GPD and adjustable high pressure of up to 100 PSI (7 kg/cm2)or more, power input 230 V,50 HZ self priming with nonmetalic with connecting nuts, ferrules and with all accessories including lead, tubing connection injection check valve complete all as specified and directed. [A]. Preparation tank (300 ltr), (i) Water inlet line, (ii) Outlet with strainer, (iii) Drain, (iv) Overflow, (v) Conical bottom for sludge deposition, (vi) Pot hole with over, (vii) Level gauge, (viii) Inspection port, (ix) Agitator 120 watt 900 RPM single phase mounted with plastic shaft and impeller. [B]. Service Tank (100 ltr), (i) Water line inlet, (ii) Dosing pump inlet arrangement, (iii) Drain, (iv) Overflow, (v) Level gauge (vi) Inspection port, make-Pearl, filter/ Briozing/ Declibec/ Aqufit. Note :- Tenderer may note that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract
Supply install in repair and commissioning of Multi-Cavity wter sanitiser/ conditioning stationproportinal dosing arrangement at zero discharge of the power ree automatic system, 100 Ltr. Tank, Cavities are compieted with Lids. Attachement -Centrifugal pump with following specifications:- Power-1 HP,0.75 KW,pipe size (suction ), 1", Delivery pipe 1",Total Head up to 6 bars, Discharge- up to 3700 LPM,Over flow valve,water inlet valve,outlet valve ( for o line automated gravity flow ) drain valve. Model-STEQUA ADS PRO System. , Make- Declibac technologies oe equivalent as specified and directed. with all assessary completed all as specified and directed.
Supply only Chlorine tablets contained in plastic cylindrical -sealed disposable sanitizer refill for disinfeetion of drinking water with arrangement for controlled relese of disinfectant in water suitable for operationthrough for recommended dosing system . (a) Relacecement indication visual & weight variation water cotact orifice design : Sealed when dry , exposed upon immersion oxperation type, Non contct ,non inhalatory complete all as specified and directed. Note :- Each Set of 25 refill.
Supply install in repair and commissioning of Granular chlorination dosing pump of high pressure single head gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U S GPD and adjustable high pressure of up to 100 PSI (7 kg/cm2)or more ,power input 230 V,50 HZ self priming with nonmetalic with connecting nuts, ferrules and with all accessories including lead, tubing connection injection check valve complete all as specified and directed. Note :- Tenderer may note that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract Make- Declibac technologies,Potter & watts all equvalant make all as specified and directed.
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified and directed
M & L for 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) complete all as specified and directed .
M & L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, whilst concrete making good as per existing surface etc complete all as specified and directed .
Taking up and down steel tubing and connections, of 15 mm to 25 mm bore of pipes complete all as specified and directed.
Supply and laying 25 mm bore steel water tubing medium grade of following bore fixed with wall/laid in floor with and including all GI fittings as required at site complete all as specified and directed.
All as per Srl item No 68 here in before but 20 mm bore
All as per Srl item No 68 here in before but 15 mm bore
S&F 50mm bore gun metal iron gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked, including dismantling the old unserviceable existing valve complete all as specified and directed.
All as per Srl item No 71 here in before but 40 mm bore
All as per Srl item No 71 here in before but 25mm bore
All as per Srl item No 71 here in before but 20 mm bore
All as per Srl item No 71 here in before but 15mm bore
S&F of 'D' Joint of 80 mm bore size complete all as specified and directed.
All as per Srl item No 76 here in before but 100 mm bore
All as per Srl item No 76 here in before but 150 mm bore
All as per Srl item No 76 here in before but 200 mm bore
M&L for repair / rectification of leakage / blockage to water supply distribution lines 15mm bore to 20mm bore of GI tubing by necessary excavation, returning / filling as required , tightening of lose joints of union, elbow, socket nipple as per site requirement including for replacement of GI union, socket, nipple as required complete all as directed.
All as per Srl item No 80 here in before but 25 mm bore to 40mm bore
All as per Srl item No 80 here in before but 50 mm bore
M&L for dewatering complete trenches manually for repairing joints by cocking and inserting spurn yarn and Run lead joint, making good/ leakless the existing joint including necessary excavation and earth work like returning, filling etc for pipes of 80 mm bore complete all as directed.
All as per Srl item No 83 here in before but 100 mm bore
All as per Srl item No 83 here in before but 150 mm bore
All as per Srl item No 83 here in before but 200 mm bore
M&L for dewatering complete trenches, repair/rectification of leakage and blockageof PPR pipes manually repairing joints by inserting proper accessories and fittings of PPR pipes making good/ leakless the existing joint including necessary excavation and earth work like returning, filling etc for pipes of 110 mm bore complete all as directed.
All as per Srl item No 87 here in before but 90 mm bore
All as per Srl item No 87 here in before but 75mm bore
Supply and fixing DI fittings for Socketed pipe, DI Bends, connecting pieces, bell mouth pieces, tapers, tee pieces of one end flanged and other end spigot or socket upto 150 mm bore complete all as specified and directed.
S&F in repairs 150 mm bore Non Return Valve at various pump houses complete as specified and directed. Make: KIRLOSKAR, RAMCO or equivalent as approved by GE.
All as per Srl item No 91 here in before but size 200 mm bore
All as per Srl item No 91 here in before but size 100 mm bore
M&L for provision of new wash out points by proper cutting and screwing of existing DI/CI/GI pipe fixing reducer tee of suitable size, supplying and fixing, Jointing, testing CI sluice valve of following size by fixing 02 Nos at each wash out point with flanged ends including necessary mountings nuts, bolts washers and packing fibers gasket on both end and making pit chamber including iron frame cover 3.15 mm thick with locking arrangements complete all as specified and directed. Wash out point at 150 mm bore pipe
All as per Srl item No 94 here in before but Wash out point at 100 mm bore pipe
All as per Srl item No 94 here in before but 80 mm bore pipe
S&F in replacement of Bib tap of PVC 15 mm bore complete
S&F in repair sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for 150 mm bore pipe, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve including making arrangement for safe working all as specified and directed. Make: BIR, KIRLOSKAR ,Kartar or equivalent as approved by GE.
S&F in repair sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for 100 mm bore pipe, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve including making arrangement for safe working all as specified and directed. Make: BIR, KIRLOSKAR or equivalent as approved by GE.
Dismantling and taking out sluice valve any size and ,M&L for repair sluice valve for 80 mm to 200 mm bore , high tensile stainless steel spindle, including nuts, bolts and gas kit ,glands and refixing after repair etc. complete all as specified and directed.
Taking up and down PP-R and PVC pipe and connections, 75 mm to 90 mm bore of pipes complete all as specified and directed.
Supply & laying/ fixing Floor & Trench, 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete all as specified and as directed of size PN-16, 75mm OD (SDR– 7.4)
All as per Srl item No 102 here in before but PN-16 pipe, 90mm OD (SDR – 7.4)
S&F in replacement PPR gate valve (brass insert) of size 75 mm bore including connection and testing complete all as directed.
S&F in replacement PPR gate valve (brass insert) of size 90 mm bore including connection and testing complete all as directed.
M&L for construction of brick masonry valve pit of size 90x90x90cm (internal dimension) one brick thick wall built in CM (1:4) on 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) both externally and internally, external plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate, including provision of hinges, handle and locking arrangement including 40 X 40 X 5mm angle iron frame fixed on top of valve pit by means of MS hold fast 40x5mm and 150mm long, embedded in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil including demolition of old unserviceable existing valve pit & pit cover complete all as specified & directed.
M&L for screwing existing steel tubing of bore 40/50mm in position for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and as directed.
M&L for screwing existing steel tubing of bore 20 mm in position for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and as directed.
M&L for running welding in any position as and where directed n.exc 6mm gitrh (thickness of metal to be welded) complete all as specified and as directed.
Laying only 80 mm bore steel water tubing with and including all GI fittings as required at site complete all as specified and directed. (NOTE:- GI pipe of 80 mm bore shall be issued under Sch B free for laying/fixing.)
Laying only 50 mm bore steel water tubing with and including all GI fittings as required at site complete all as specified and directed. (NOTE:- GI pipe of 50 bore mm shall be issued under Sch B free for laying/fixing.)
Laying only 40 mm bore steel water tubing with and including all GI fittings as required at site complete all as specified and directed. (NOTE:- GI pipe of 40 bore mm shall be issued under Sch B free for laying/fixing.)
Taking up cast iron/ PVC /HDPEwater mains of following bore of pipes (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead. 100 mm 150 mm bore
Supply and laying of 150 mm bore centrifugally cast (Spun) ductile iron pressure pipe with spigot & socket end, class K-9 in any length laid in trenches, conforming to IS-8329/2000 with cement mortar lining with and including rubber gasket jointing conforming to IS-15382/tyton joint complete with all fittings e.g Tee, Bends etc all as specified and directed.
All as per Srl item No 114 here in before but for 100 mm bore complete all as specified and directed.
M&L for run lead joint Spigot and socketed pipes and fittings, for the 100mm bore of pipe complete all as specified
All as per Srl item No 116 here in before but for 150 mm bore
M&L for preparation of old concrete/plastered surfaces by scrapping, brooming etc and applying two coats of exterior emulsion weather proof paint (Apex of Asian paints or equivalent) over dome, wall, columns, beams including all pipe lines etc of overhead reservoir using scaffolding & necessary safety precaution complete all as specified and directed for the following RCC over head reservoir:- (a) RCC overhead reservoir 100000/50000/25000 gallon capacity, 50 to 60 feet staging. Note :- Colour status shall be as under :- (i) Rising main - Blue colour. (ii) Delivery main - Green colour. (iii) Washout main - Red colour. (iv) Overflow main - Yellow colour.
Making connection of PP-R distribution branches 50 to 75 with PP-R main of following size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
Making connection of PP-R distribution branches 16 to 40 with PP-R main of following size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
Making connection of PP-R distribution branches 75 to 110 with PP-R main of following size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
S&F in replacement cast iron medium pressure Air Release Valve of following sizes complete all as specified and directed for 150 mm bore.
All as per Srl item No 122 here in before but for 100 mm bore.
S&F in replacement Pneumatic Actuator valve of size 80mm bore as per site requirement complete all as specified and as directed.
S&F in replacement foot valve 100 mm all as specified and as directed.
S& F in replacement submersible pump & motor electric driven 415 Volts, TP suitable for 200/250 mm dia bore well casing pipe of size 200/250 mm supply complete of 41 HP all as specified and directed.
S& F in replacement submersible pump & motor electric driven 415 Volts , TP suitable for 200/250 mm dia bore well casing pipe of size 200/250 mm supply complete of 50 HP all as specified and directed.. Note :- Tenderer may note that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down protection pipe,PCC Cover/Bricks etc all as specified and directed by the Engineer-in-Charge for the following sizes:(a) 70 Sqmm to 120sqmm any core
Supply, laying, jointing and testing XLPE/ P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-Make:-HAVELLS Ref No-(A2XWY/A2XFY) ,ICL,CCI,Fort GloSter Etc.
(c) 70 Sqmm 3.5 core
(d) 95 Sqmm 3.5 core
(e) 120 Sqmm 3.5 core
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed.
Removal of surplus excavated soil exc. 50 mtr but n. exc. 250 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 M above the starting point etc complete all as directed.
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed . NOTE: - Punned thickness only 18cm shall be measurement & paid.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed
Taking down the Unseviceable LT panel installed at PH and replacement with new one cpri approved with following parts including panel board Wall mounted LT panel board indoor type of size 1200 x 1200 x400 mm with sheet CRCA sheet of 2 mm thickness comprising of the following :- ( a) 3 pole power contactor type ML 4 suitable for operation on,440 Volts, AC, 50 Hz -03 Nos (b) over load protection relay with relay range 45-75A suitable for operation on 3 phase, 415 V -01 Nos (c) voltmeter three phase anologue type class 1 voltage range 0-500 V flush mounting 96x96mm, (d) ammeter three phase anologue type 5A class 1 of range 0-200 A flush mounting 96x96mm inculding CT 200/5 (e) MCCB 125 A capacity 3 pole for 415V -01 Nos (f) Supply and fix in repair MCCB 200 A capacity 4 pole for 415V -01No (g) indicating lamp on all 3 phases R Y B -01 set (h) PVC insulated multistranded copper conductor single core cable 4 sq mm (Nominal cross sectional area) as per site requirement including suitable size of copper lugs etc all as specified and directed-01 Job (j) single phase preventer direct mounting type with relay range 28-40 A 230 Volts suitable for electric motor of water supply installation-01 No (k) Electronic timer type ST 100 suitable for operation on 240/360/415 volts 50 Hz for 3-10 Sec-01 Nos. (l) Painting complete panel board with one coat of silver inside and outside -01 Job
S&F for RMG three phase GSM-SPAT pump Controllers with all protection features (Mobile Motor Pump Starter) Along with Overhead Tank Full Cut Off are most unique and specially designed for farmers,agriculturists and industries to operate and monitor remotely located submersible pumps and motors. They can switch ON and switch OFF the motor pumps from their from their homes or anywhere by using a SMS / CALL/ Android Application.It also saves water, time and electricity. Our GSM based mobile pump controller are manufactured with advanced embedded microcontroller based advanced all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .