Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
13 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT BAHL
16 conditions · 2 needing a document upload
Financial Eligibility Criteria: In terms of clause 1.1.12.2(ii) of the tender document, the tenderer must have minimum average annual contractual turnover of V/N or 'V" whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-15, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. The tenderers shall submit Certificates to this effect which may be an attested Certificate from the concerned department / client and/or Audited Balance Sheet duly certified by the Chartered Accountant etc
Tenderer / Contractor shall upload a statement of contractual payments received during last three financial years and current financial year on prescribed Performa as per Annexure-15. Details shall be based on Form 16-A issued by the employer i.e. certificate of deduction of tax at source under Section-203 of the Income Tax act 1961. Self-attested photocopies of the form 16-A / form 26AS shall be enclosed in support of the above. Railway may invite the tenderer for online verification of Form-26AS.
In terms of clause 1.1.12.2 of the tender document, the (a)The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Similar work is defined as under: "Design, Supply, Installation, testing & commissioning of 11 KV or above Sub-Station including associated electrical works with or without AMC" .
In terms of clause 1.1.12.2 (iii) of the tender document,: The tenderer must submit attested copy of valid Electrical contractor license along with his offer. The Electrical License must be issued for HT level and 1.1.1 should be in the name of the firm, any partner, or the sole proprietor. Offer shall be summarily rejected if tenderer does not have Electrical contractor license issued by State / Central government
71 conditions · 20 needing a document upload
Requisite earnest money, (ON ONLINE mode (No Documentary Proof required))
Cost of tender document
Requisite earnest money ,(ONLINE mode )
Requisite earnest money ,(ONLINE mode )
Tenderers are required to upload Annexure -19A & Annexure-20 without which the offer is summarily rejected .
PAN CERTIFICATE : PAN The tenderer shall submit the photocopy of Permanent Account Number (PAN) issued by Income Tax authority attested by Gazetted officer / self attested.
GSTIN number: Bidder shall submit the photocopy of GSTIN number
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions. Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are required to upload PAN Certificate, GSTIN Certificate as well as Certificates as per Annexure-9, Annexure- 10, Annexure-11, Annexure-12, Annexure-13, Annexure-14, Annexure-15, Annexure-16, Annexure-18, Annexure-21.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Payment of Earnest money Deposit (EMD) and Tender Document Cost (TDC) in respect of E- tendering will only be accepted through Net-Banking and payment Gateway only. No other mode of payment except this will be accepted and any offer without the same will be treated as invalid. Details of bank account no. a n d technical details have bee n provided for in the software (IREPS) to which prospective registered tenderers will have access at the time of tendering.
However, For service contracts, MSMEs registered with District Industries Centres, Khadi and Village Industries Commission, Khadi and Village Industries Board, Coir Board, National Small Industries Corporation, Directorate of Handicraft and Handloom, Any other body specified by Ministry of MSME, shall be supplied such tender document free of cost on confirmation (Xerox Copy) of their evidence to this effect.
Partnership deeds, Power of Attorney etc.: - The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / company / Joint Venture (JV) / Registered Society / Registered Trust etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
Sole proprietor Firm: The Tenderer shall submit the NOTARIZED COPY OF AFFIDAVIT.The tenderer whether sole proprietor, a partnership firm or a limited company, if they want to act through agent or individual partner(s) should submit alongwith the tender, a power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person specifically authorized him/them to submit the tender, sign the agreement, receive money, witness measurements, sign measurement books, compromise, settle relinquish any claim(s) preferred by the firm and sign NO CLAIM CERTIFICATE and refer all or any disputes to arbitration.
Statement of works being executed in hand by contractor indicating description of work, contract value, approximate value of balance work yet to be done and date of award (ANNEXURE 14).
List of engineers/personal: They have established technically competent and adequately staffed organization and proposed to be engaged , the details given at Annexure-12 to ensure that the services required under this tender can be satisfactorily rendered at all stages of the work.
EQUIPMENT DETAIL : They have sufficient equipment, plants and machinery along with necessary document to establish ownership/hiring to meet the obligation under contract and to complete the work contracted well within the stipulated time schedule and accepted by him/them. (ANNEXURE-11)
Tenderers are required to upload requisite details in prescribed proforma as per Annexure-9(Declaration form regarding site etc.) in document
PAN CERTIFICATE : PAN The tenderer shall submit the photocopy of Permanent Account Number (PAN) issued by Income Tax authority attested by Gazetted officer / self attested.
GSTIN number: Bidder shall submit the photocopy of GSTIN number
(ii) In case tenderer is other than sole proprietorship firm, following documents shall be submitted by the tenderer:
(a) Partnership Firm: The tenderer shall submit (i) a copy of Partnership Deed and (ii) a copy of Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm.
(b) Joint Venture (JV): The tenderer shall submit documents as mentioned in Clause 17 of the Tender Form (Second Sheet).
(c) Company registered under Companies Act-2013: The tenderer shall submit (i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.
(d) LLP (Limited Liability Partnership) Firm: If the tender is submitted on behalf of a LLP Firm registered under LLP Act-2008, the tenderer shall submit alongwith the tender- (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii)a copy of Power of Attorney/Authorisation issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm.
(e) Registered Society & Registered Trust: The tenderer shall submit (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust.
(iii) If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole Proprietorship firm / Partnership firm / Joint Venture / Registered Company etc., then the tender shall be treated as having been submitted by the individual who has signed the tender.
(iv) After opening of the tender, any document pertaining to the constitution of Sole Proprietorship Firm / Partnership Firm / Registered Company/ Registered Trust / Registered Society etc. shall be neither asked nor considered, if submitted.
(v) A tender from JV / Partnership firm etc. shall be considered only where permissible as per the tender conditions.
15. The tenderer whether sole proprietor, a company or a partnership firm / joint venture (JV) / registered society / registered trust etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person specifically authorizing him/them to submit the tender, sign the agreement, receive money, co-ordinate measurements through contractor's authorized engineer, witness measurements, sign measurement books, compromise, settle, relinquish any claim(s) preferred by the firm and sign "No Claim Certificate" and refer all or any disputes to arbitration.
16. Employment/Partnership etc. of Retired Railway Employees: (a) Should a tenderer be a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, whether in the executive or administrative capacity or whether holding a pensionable post or not, in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, or should a tenderer being partnership firm / company / joint venture (JV) / registered society / registered trust etc have as one of its partners a retired Engineer or retired gazetted officer as aforesaid, or should a tenderer being an incorporated company have any such retired Engineer or retired officer as one of its directors or should a tenderer have in his employment any retired Engineer or retired gazetted officer as aforesaid, the full information as to the date of retirement of such Engineer or gazetted officer from the said service and in case where such Engineer or officer had not retired from government service at least 1 year prior to the date of submission of the tender as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, or to take the employment under the Contractor, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender. Tenders without the information above referred to or a statement to the effect that no such retired Engineer or retired gazetted officer is so associated with the tenderer, as the case may be, shall be rejected.
(b) Should a tenderer or Contractor being an individual on the list of approved Contractors, have a relative(s) or in the case of partnership firm/ company / joint venture (jv) / registered society / registered trust etc. one or more of his shareholder(s) or a relative(s) of the shareholder(s) employed in gazetted capacity in the Engineering or any other department of the _____________ railway, the authority inviting tenders shall be informed of the fact at the time of submission of tender, failing which the tender may be disqualified/rejected or if such fact subsequently comes to light, the contract may be rescinded in accordance with provision in clause 62 of standard general conditions of contract.
PAN CERTIFICATE : PAN The tenderer shall submit the photocopy of Permanent Account Number (PAN) issued by Income Tax authority attested by Gazetted officer / self attested.
GSTIN number: Bidder shall submit the photocopy of GSTIN number
Payment of Earnest money Deposit (EMD) and Tender Document Cost (TDC) in respect of E- tendering will only be accepted through Net-Banking and payment Gateway only. No other mode of payment except this will be accepted and any offer without the same will be treated as invalid. Details of bank account no. and technical details have been provided for in the software (IREPS) to which prospective registered tenderers will have access at the time of tendering.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Electrical works in connection with provision of crossing station alongwith goods facilities at Sopore station and one additional loop line at Baramulla station on BAHL-BRML section.
17-ELECT-C-GPS-SB-26~NR
17-ELECT-C-GPS-SB-26
Open
Works - General
6 Months
Ramban, Jammu And Kashmir
₹0
₹2.0 L
23 Oct 2026
23 Oct 2026
30 Oct 2026
172 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 82,07,419.05 | ||
| — | 20000.00 | — | — | ||
| Provision Hiring of vehicle for Transportation of man & Material per Km Basis. | — | — | — | 4,88,400 | |
| — | 2.00 | — | — | ||
| Prov. of 11Mtr 4 Pole 410-SP-56 structure with foundation and MS structure made of MS ISMC 100X50X50X6 mm size & MS Angle 50x50x6 mm size a set of pin insulator 33KV , 2 No DO Fuse Set and 2 Nos. 33 KV gang operated horizontal isolator with handle and 33KV Disc insullators, Stay Sets, sets of Cross Channels, of size as required at site including Nuts, Bolts, Hardware etc as required for complete job. Job includes making of Foundation of suitable size for Erection of 4 Pole structure connection to 2 Nos. Distinct earth pits complete in all respects. . | — | — | — | 13,04,796.8 | |
| — | 2.00 | — | — | ||
| Supply, erection/fixing of safety items complete with :- a). Fire extinguisher, dry chemical powder type(ISI marked) suitable for electric fire 10Kgs. capacity -2 Nos.(b). GI Fire buckets, 24 gauge fitted on steel stand as per approved drawing, each 10Ltr. Capacity filled with clean dry ordinary sand - 6 Nos.(c). First aid box complete with medicines of approved make -1 No. (d). Electric shock treatment chart (larger size) with aluminium frame and glass on front or laminated as approved. -2 Nos.(e) 11 KV danger plate conforming to relevant IS - 8 Nos. (f). Schematic diagram of HT/LT installation screen printed on Hylum sheet with aluminium frame. Approx size 1200x600 mm -1 No. (g). Data's of transformer screen printed on white Hylum sheet with aluminium frame as approved. Approx size 900x600 mm. - 2 Nos. | — | — | — | 47,615.04 | |
| — | 1.00 | — | — | ||
| Supply, erection, testing and commissioning of pole mounted 33 KV CT/PT combined Metering unit, 3- phase, 50 Hz, ONAN Cooled, outdoor type having CT ratio 50A/5A & PT ratios 33KV/110V, with weather proof metering cubical, outdoor type suitable for 3phase HT tri-vector meter, fabricated out of 2mm mild steel, powder coated with sealing and locking facility, HT, Tri- vector meter 3-phase 4 wire 50/5A and 33KV/110V along with sealing and testing from JKPDCL etc. as a complete job. | — | — | — | 3,50,000 | |
| — | 2.00 | — | — | ||
| Dismantling of transformer/DG set from existing sub-station & transportation other city reinstallation, testing & commissioning in other sub-station | — | — | — | 45,080 | |
| — | 50.00 | — | — | ||
| Connection with 40x6 mm copper strip as per IS 3043/1987 (Latest Version) in 50 mm dia GI pipe B-class 300 mm deep in ground/ recessing in floor for neutral of transformer/Alternator as per drawing approved and neutral including supply and laying of GI pipe of suitable size as required for protection of copper strip as laid in open including painted with red signal paint to avoid corrosion. | — | — | — | 45,764.5 | |
| — | 4.00 | — | — | ||
| Supply and providing of Maintenance Free Earthing with primary MS conductor 40 mm dia 3000 mm long and secondary MS Electrode 80 mm dia 3000 mm long including digging pit of size 5ft.x5ft.x10ft. and using earth enhancement chemical compound minimum 75 kg. Per pit suitable for 40 KA current capacity and as per RDSO specification No. RDSO/PE/SPEC/PS/0109(REV- 0)-2008 and as per explanatory note. | — | — | — | 71,616 | |
| — | 6.00 | — | — | ||
| Earthing with 600x600x6mm thick GI plate earth electrode as per IS 3043 (Latest Version) to achieve earth resistance less than one ohm including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement (Approx. size 600x600mm) on top, watering pipe,connections from earth plate to top with 40x10mm GI strip in 50mm dia GI pipe class 'B', provision of earth plate as per drawing and technical specification | — | — | — | 29,220.3 | |
| — | 30.00 | — | — | ||
| Connection with GI strip 300mm deep in ground/recessing in floor/clamping in Trenches of sub station by grouting clamps manufacture with MS sheet 14 SWG, from earth electrode strip to HT panel/LT panel/AMF panel/Transformer/DG set etc. as per approved drawing and technical specification.including supply of material, of size: 40x5mm | — | — | — | 4,514.7 | |
| — | 60.00 | — | — | ||
| "Supplying and fixing suitable size GI box including providing and fixing 3 pin 5/6 A Piano Type socket outlet and 5/6A Piano Type switch, connections etc as required. as per IS, IE rule & site requirement of reputed make " | — | — | — | 6,327 | |
| — | 60.00 | — | — | ||
| Supply of 100x100x60mm deep M.S switch box conforming to IS5133 ( Part - I ) - 1969(latest version) with white Phenoliclaminated sheet cover of approved make on front of box withbrass screws & cup washers, recessing as per Tech. Specificationincluding earthing. | — | — | — | 4,884.6 | |
| — | 50.00 | — | — | ||
| Supply of 180x100x60mm deep M.S switch box conforming to IS5133 ( Part - I ) - 1969(latest version) with white Phenoliclaminated sheet cover of approved make on front of box withbrass screws & cup washers, recessing as per Tech. Specificationincluding earthing. | — | — | — | 5,550.5 | |
| — | 40.00 | — | — | ||
| Supply of 300x200x100mm deep M.S switch box conforming toIS 5133 ( Part - I ) - 1969(latest version) with white Phenoliclaminated sheet cover of approved make on front of box withbrass screws & cup washers, recessing as per Tech. Specificationincluding earthing. | — | — | — | 10,657.6 | |
| — | 40.00 | — | — | ||
| "Supplying and fixing suitable size GI box including providing and fixing 3 pin 15/16 A Piano Type socket outlet and 15/16A Piano Type switch, connections etc as required. as per IS, IE rule & site requirement of reputed make" | — | — | — | 7,102 | |
| — | 700.00 | — | — | ||
| Supply of Piano type switch 5A (1-way) as per IS 4949-1968(latest version) /Bell push as per IS 4794 ( Part 2 )-1986(latest version)/flush type socket outlet as per IS 1293-1988(latest version) & installation on the recessed switch boxincluding cutting of phenolic laminated sheet, connection, testing& commissioning as per Tech. Specifications. | — | — | — | 17,269 | |
| — | 6000.00 | — | — | ||
| Supply, laying, fixing,testing and commissioning of 1.5sq mm FRLS, PVC insulated multistranded copper conductor single core cable 1100 Voltsconfirming to IS-694(latest version),make Finolex,Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wi | — | — | — | 1,02,000 | |
| — | 4.00 | — | — | ||
| "Supply, fixing, testing and commissioning of 380mm sweep, 1400 rpm (approx) propeller type exhaust fan complete as per IS, IE rule & site requirement. Make Bajaj, Usha, Havells, Orient or equivalent" | — | — | — | 17,940 | |
| — | 4000.00 | — | — | ||
| Supply, laying, fixing,testing and commissioning of 2.5sq mm FRLS, PVC insulated multistranded copper conductor single core cable 1100 Voltsconfirming to IS-694(latest version),make Finolex,Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wi | — | — | — | 1,20,000 | |
| — | 300.00 | — | — | ||
| Supply, fixing,testing and commissioning of 3-pin ceiling rose 5 Amp capacity on existing MS/PVC conduit junction boxes/casing caping Anchor, Cona, Kinjal, SSK or equivalent as per IS, IE rules and site requirement. | — | — | — | 8,139 | |
| — | 4000.00 | — | — | ||
| Supply, laying, fixing,testing and commissioning of 4 sq mm FRLS, PVC insulated multistranded copper conductor single core cable 1100 Voltsconfirming to IS-694(latest version),make Finolex,Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wi | — | — | — | 1,72,000 | |
| — | 4500.00 | — | — | ||
| supplying and recessing/ fixing of 25 mm dia medium regid PVC conduit pipe conforming to IS9537 part- III / 1983 (latest version) with accessories, junction box, bend including making chase, plastering / clamping as approved by railway and as per explanatory notes | — | — | — | 3,44,160 | |
| — | 300.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaries,having system wattage 1x > 22w (Max.), LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be of make Phillips, Bajaj,Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3'), & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') or latest | — | — | — | 2,11,800 | |
| — | 30.00 | — | — | ||
| Supply, Fixing, Testing and commissioning of of Super energy efficient BLDC elect Ceiling Fan of <=35W heving BEE five star rating 1400mm Sweep, 230V AC 50 HZ Speed 320 RPM with tolerance limit plus minus to 10% as per IS 374-1979, power Factor more than or equal to 0.94, class of insulation B | — | — | — | 94,980 | |
| — | 2.00 | — | — | ||
| SET&C of Double door wall mounted Pre- fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCCB 4Pole 125 A 35 KA B/C - 1 No. (ii). Outgoing MCB 6 to 32 A. SP 10 KA B/C - 21 Nos. | — | — | — | 41,092 | |
| — | 5.00 | — | — | ||
| SET&C of Double door wall mounted Pre- fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; with IC MCB TPN 63A and O/G MCB SP 6-32A = 18 nos | — | — | — | 43,070 | |
| — | 3750.00 | — | — | ||
| Laying, underground/road/Railway track, recessing in platform/wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KVgrade LT XLPE insulated armoured, aluminum conductor cable ofsize Above 25 sqmm to 120 sq mm including making chase &plastering after laying of cable/digging of cable trench, sandcushioning, protective covering with second class bricks,provision of cable route marker as per Tech. Specfn. includingend terminations with Alu. Clamping socket/lugs, testing andcommissioning.Laying, underground/road/Railway track,recessing in platform /wall along with Rly. Track/in laid RCC/GIpipe as required 1.1 KV grade LT XLPE insulated armoured,aluminum conductor cable of size Upto 25 sqmm includingmaking chase & plastering after laying of cable/digging of cabletrench, sand cushioning, protective covering with second classbricks, provision of cable route marker as per Tech. Specfn.including end terminations with Alu. Clamping socket/lugs,testing and commissioning.LT cables size 25 to 120 sqmm (item no 27,28,56) | — | — | — | 2,86,800 | |
| — | 4500.00 | — | — | ||
| Laying, underground/road/Railway track, recessing in platform/wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KVgrade LT XLPE insulated armoured, aluminum conductor cable ofsize Upto 25 sqmm including making chase & plastering afterlaying of cable/digging of cable trench, sand cushioning,protective covering with second class bricks, provision of cableroute marker as per Tech. Specfn. including end terminationswith Alu. Clamping socket/lugs, testing and commissioning. | — | — | — | 3,33,045 | |
| — | 1300.00 | — | — | ||
| Supply & erection of 103 mmInner dia and 120mm outer diaDouble Walled Corrugated pipe(DWC pipe) in ground underRailway track/road as required andas per explanatory note. | — | — | — | 6,00,600 | |
| — | 20.00 | — | — | ||
| Design, manufacturing of floor mounted MS feeder post made of MS sheet 16 SWG Die pressed of size 550mm x 450mm x 275mm deep complete with Aluminium bus bars four Nos. having cable glands 2 Nos. duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals. | — | — | — | 94,780 | |
| — | 20.00 | — | — | ||
| Supply, fixing,testing and commissioning of hot dip galvanized octagonal pole 5 Mtrs. (Single Arms) long, confirming to IS 2629/BSEN ISO 1461 latest version including casting, muffing with cement concrete foundation (1:2:4) painting, earthing etc as per tech. specification at Annexure 'H', ISS & IE rules & site requirement. The pole shall be complete with holes, Anchor bolts, bottom plate etc and manufactured by any ISO: 9001 certified firm. Make - Bajaj, Surya, UtkArsh or eq | — | — | — | 1,96,660 | |
| — | 2000.00 | — | — | ||
| Supply & recessing/fixing on surface 6 SWG GI wire for loopearthing as required as per technical specification. | — | — | — | 24,660 | |
| — | 20.00 | — | — | ||
| Supply, fixing,testing and commissioning of hot dip galvanized octagonal pole 5 Mtrs. (Double Arm)long, confirming to IS 2629/BSEN ISO 1461 latest version including casting, muffing with cement concrete foundation (1:2:4) painting, earthing etc as per tech. specification at Annexure 'H', ISS & IE rules & site requirement. The pole shall be complete with holes, Anchor bolts, bottom plate etc and manufactured by any ISO: 9001 certified firm. Make - Bajaj, Surya, UtkArsh or eq | — | — | — | 2,22,320 | |
| — | 16.00 | — | — | ||
| Supply, installation,testing and commissioning of 150 Watt LED based flood light fitting, operating voltage single phase 230V AC, 50Hz complete with led lamp & all mounting arrangement, accessories & flexible copper wire for connetion as per ISS/IR rules & as per CEE/NR Specification No. CEE/NR/121-Elect/PS/2018 (Rev.03) dated 28.06.2018 & CEE/NR/121-Elect/PS /2019 (Rev.4) dated 04.11.2019 respectively or latest | — | — | — | 2,72,976 | |
| — | 30.00 | — | — | ||
| Earthing with 40mm dia GI pipe class 'B', 3 meter long earthelectrode as per IS:3043 (Latest Version) to achieve earthresistances less than 5 ohms including construction of masonryenclosures with hinged cover plate of cast iron with lockingarrangement (approx. size 400mmx400mm) on top, provision ofearth plate, connections from earth electrode to switch gear/poleas per drawing. | — | — | — | 65,353.2 | |
| — | 1.00 | — | — | ||
| Design, manufacture, supply,installation, testing &commissioning of Outdoor typeTimer Control Panel suitable tooperate 3 phase 4 wire 415 V ACsupply system for automaticswitching OFF & ON of allluminaries as per explanatory notewith following accessories :- (i)MCB (TPN) 63 A. B/C 10 kA -oneno.- (ii)Timer with CM 40Contactor Chargeablecells/battery- one No. (iii)ToggleSwitch - one no. | — | — | — | 21,457 | |
| — | 60.00 | — | — | ||
| Supply and erection of minimum 45 W LED Street light fitting operating voltage single phase 230 volts AC, 50Hz complete with all accessories as per CEE/NR Specification. No.CEE/NR/121-Elect/PS/2018 (Rev '3') Dated 28.06.2018 & CCE/NR/121-Elect/PS /2019 (Rev.4) dated 04.11.2019 or latest respectively including connection with 2x2.5 sq.mm PVC insulated multi stranded FRLS copper conductor cable, testing, commissioning & earthing required and as per explanatory note. | — | — | — | 2,41,080 | |
| — | 1.00 | — | — | ||
| Supply of 16 M High Mast lightingsystem complete with raisinglowering arrangement and suitableLantern Carriage for 9 Nos. floodlight luminaries and control gearincluding accessories i.e. lightningconductor, Aviation neon light,integral drum winch compensatingdisc head frame, power tool,manual tool, double frame withfoundation bolts etc. includingcasting of RCC foundation asrecommended by Manufacturerand as per explanatory note.including erection, testing andcommissioning. | — | — | — | 2,92,493 | |
| — | 4.00 | — | — | ||
| SETC SH rail post 1.5/ 2.5 mtrs. Long for safety of high mast. Work includes cutting of 50 or60 or 75 or 90 lbs capacity rails in pieces of desired length (1.5/2.5 mtrs.),digging of pit and erection of rail pole (Rails will be supplied by railway and is to be collected by contractor from concerned SSE). | — | — | — | 4,360.92 | |
| — | 100.00 | — | — | ||
| Supply & laying of HDPE Pipe 140mm Inner dia and 160 mm outerdia through trenchless methodunder railway track/road PF etc oras required at site | — | — | — | 1,38,300 | |
| — | 4.00 | — | — | ||
| Earthing with 600x600x6mm thick Cu plate earth electrode as per IS 3043 (Latest Version) to achieve earth resistance less than one ohm including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement (Approx. size 600x600mm) on top, watering pipe,connections from earth plate to top with 40x10mm Cu strip in 50mm dia GI pipe class 'B', provision of earth plate as per drawing and technical specification | — | — | — | 35,584.64 | |
| — | 300.00 | — | — | ||
| "Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with Piyno switch, SUN micar plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. as required of reputed make complete conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.10.3. Group C" | — | — | — | 67,794 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing and commissioning of 250mm poly carbonate Exhaust fan | — | — | — | 9,236 | |
| — | 15.00 | — | — | ||
| Supply of 7/9 W LED Bulb | — | — | — | 2,280 | |
| — | 2.00 | — | — | ||
| Supply, erection, testing and commissioning of the following Double door wall mounted Pre-fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCB 40 A DP 10 KA B/C - 1 No. (ii) Outgoing MCB 6 to 32 A. SP 10 KA B/C - 6Nos. | — | — | — | 7,166 | |
| — | 1.00 | — | — | ||
| Design, Manufacture Supply,erection, testing & Commissioningof outdoor type LT Distributionboard suitable for 3 phase 4 wire415 V AC supply systemcomprising: i) I/C MCCB 4P 250 Awith adjustable thermal magneticrelease & 35 KA B/C -1No ii) Outgoing MCCB 4P 125 A with 35 KAB/C -2No. iii ) Out going MCCB 63A 4P with 35 KA B/C- 1No. iv)) Outgoing MCCB 32 A 4P with 35 AB/C-4No. v) O/G MCB 32 A DP 10 KAB/C- 12 Nos, The Distribution board shall be complete with 1 No. digital Amp. & Volt Meter withselector switch, LED indication lamps on incoming feeder 400Amps. Copper bus bars for Phases and 200Amps for Neutral as per drawing approved by Railways and explanatory note | — | — | — | 2,05,786 | |
| — | 20.00 | — | — | ||
| Supply and fixing of bracket on pillar or as required made out of GI pipe 1 M 40mm dia class B GI pipewith ISI marked of approved make & shape suitable bracket shall be fixed with double clamp made of 40x5 mm GI clamp & suiatable GI nut bolt & washer & as per explanatory note | — | — | — | 11,480 | |
| — | 100.00 | — | — | ||
| Supply, laying and connection with GI Strip GI 25x5 mm (galvanized) conforming to relevant IS and as per IS 3043/1987(or Latest Version) 300mm deep in ground/recessing in flooras required. | — | — | — | 8,000 | |
| — | 20.00 | — | — | ||
| Dismantling of one rail/TubularPole by digging /cutting of 450 mmfrom ground level includingoverhead conductor, bracket,insulators, earth wire, ground wireetc. and transported the samefrom site to the store . | — | — | — | 24,260 | |
| — | 25.00 | — | — | ||
| Supply and laying of 50 mm dia. GI pipe class B ISI markedunder road/clamping with erected pole or wall as per technicalspecifications and drawing for passing cable | — | — | — | 7,771.25 | |
| — | 25.00 | — | — | ||
| Supply and laying of 100 mm dia. GI pipe class B ISI marked under road/clamping with erected pole or wall as per technical specifications and drawing for passing cable | — | — | — | 17,948 | |
| — | 1.00 | — | — | ||
| SITC of 33 KV DO fuse set ( Knife Type ) 800 Amp | — | — | — | 26,794 | |
| — | 1.00 | — | — | ||
| Supply of 25HP, 18.75KWOpen well Submersible pump, Horizontal type suitable for three phase, 50Hz as per the detailed description. make-lubimodel no.LHS38 or similar | — | — | — | 83,614 | |
| — | 1.00 | — | — | ||
| Supply, Erection, Fixing,Testing and commissing of LTpanel having incoming 1x 400Amp MCCB 35kA FP withoutgoing of 3x250 Amp MCCB35 kA FP, 3x125 Amp MCCB35 kA FP and 1x63 AmpMCCB 35 kA FP with Ampmeter, volt meter andindicator. Make of MCCB&MCB M/s Legrand, Havells,Schenider | — | — | — | 1,99,721 | |
| — | 3.00 | — | — | ||
| Design,manufacturing,supply erectiontesting & commissioning ofoutdoor type feeder pillertype 9 panel LT distributtionsystem suitable for 3 phase 4wire 415 V AC supplycomprising : i) I/C MCCB 4P125A with adjustable thermalmangnetic release & 35A KAB/C-1No. ii) Out going MCCB4P 63 A with 35 KA B/C -2Nosiii)Out going MCCB 32A 4Pwith 5KA B/C-6Nos. Thefeeder pillar shall be completewith copper bus bars 150Amps. for phases and 75Amps for neutral as per drawing approved by railway sand explanatory Notes. | — | — | — | 3,67,920 | |
| — | 150.00 | — | — | ||
| Supply, Fixing, Testing and commissioning of 70 watt LED medium bay light fitting | — | — | — | 4,93,200 | |
| — | 1.00 | — | — | ||
| Provision of Temporary lighting arrangement During NI/PNI | — | — | — | 2,50,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
tenderdocumentfinalsopore.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .