Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-Finance | L1 | Accepted-Finance Lowest Bid | |
| 2 | L2₹9.0 L+₹31,081.18 (3.58%)Rejected-Finance 189 SUKANTA NAGAR MILANPALLY SONARPUR SOUTH 24 PARGANAS WEST BENGAL 700150 | SONARPUR | SOUTH 24 PARGANAS | WEST BENGAL | 700150 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹10.2 L+₹1.5 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Higher Bid | |
| 4 | L4₹10.2 L+₹1.5 L (17.3%)Rejected-Finance P O DHAP DHAPI MALLICKPUR P S BARUIPUR 24PGS S PIN 743387 | 24 PARAGANAS SOUTH | WEST BENGAL | 743387 | L4 | Rejected-Finance Higher Bid | |
| 5 | L5₹10.6 L+₹1.9 L (22.2%)Rejected-Finance | L5 | Rejected-Finance Higher Bid |
Tender Value
Refer Docs
EMD Value
₹22,712
Closing Date
11 Jun 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, South 24 Pgs. Elect. Divn.
57/2 Diamond Harbour Road, Kolkata -700 023
Proposed Urgent Repairing and Renovation Work of Raidighi RH, Mathurapur-II Block in the District of South 24 Parganas - EI Works.
2025_WBPWD_851593_1
WBPWD/EE/S24PED/eNIT16/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
Mathurapur-II
Please refer Tender documents.
4 documents required · 4 mandatory
₹22,712
South 24 Parganas Electrical Division
1 Nov 2025
26 May 2025
13 Jun 2025
26 May 2025
11 Jun 2025
31 May 2025
30 May 2025
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 nos. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. Average run 8 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish On Board
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2×56/0.3 (4 sqmm) + 1×36/0.3 (2.5 sqmm) ECC [HTPN DB to AC]
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [VTPN to TPN DB ]
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Supply & Fixing 240V, 25A, Modular type starter (Brand approved by EIC) with 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240V, 25A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top, on 2 module GI Modular Switch Board complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. (For AC)
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 2 nos. 240 V, 6 A, 3 pin Piano key type type plug socket (Brand approved by EIC) with 2 nos. 6A Piano key type type switch, on sheet metal switch board embedded in wall incl. S&F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (6A+6A Socket Board)
SUPPLY & FIXING OF LIGHTS:
Supply and delivery of Single LED Fitting with all accessories as directed by EIC. [Make: Philips Havells, Bajaj, CG, Wipro or as per EIC]
Supply and delivery of Twin LED Fitting with all accessories without LED Tube as directed by EIC. [Make: Philips, Havells, Bajaj, CG, Wipro or as per EIC]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Extra for suspension exceeding 25 cm with S&F additional 2 nos. 20 mm dia E.I. Conduit(14 SWG) support as per G.S & necy. PVC insulated copper wire and painting etc, as per required
Supply and delivery LED Tube 18Watt, 230V AC, 50Hz, 4000K NW, THD<10%, bult in 2.5KV SPD with all accessories as directed by EIC. [Make: Philips, Havells, Bajaj, CG, Wipro or as per EIC]
Fixing only LED/ florescent tube light on existing fitting .
Supply, Delivery and fixing of LED PANEL LIGHT RECESS SQUARE suitable for mounting with Armstrong/Grid false ceiling. 22 W in 200 x 200 mm² (>100 Lumen/Watt) as per EIC (Make - Philips/CG/Wipro/Jaguar or Equivalent) [In-replace of damaged light at BMOH Chamber]
Supply, Delivery and Fixing of PANEL LIGHT SURFACE SQUARE suitable for mounting with ceiling. 22 W in 225 x 225 mm² (>100 Lumen/Watt) as per EIC. To be fitted with the help of screws and plate provided at the back side of the fitting. (Make - Philips/CG/Wipro/Jaguar or Equivalent) [In-replace of damaged light at OT]
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set. [Waiting Room]
Supply, Delivery Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong / Grid ceiling. 24 W in 2 ft x 2 ft (>100 Lumen/Watt) as per EIC (Make - Havells/ Philips/CG/Wipro/Jaguar) [Labour Room]
Fixing only above fitting after cutting false ceiling incl. S&F 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed copper wire in 20mm size PVC rigid conduit 'FR' (Precision make) & mending good damages.
Supply & Fixing of 220-240 V B22 9 Watt CDL/ 6500K LED Lamp as per EIC. [Replace of Damage Lamp] (Make-Havells/Philips/Crmpton or Equivalent)
Supply & Fixing of 220-240 V LED COLOUR LAMP 0.5W as per EIC [Night lamp for ward] (Make- Havells / Philips / Crmpton or Equivalent)
S&F angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
SUPPLY & FIXING OF FANS:
Supply & delivery of 1200 mm sweep 230 volt AC Ceiling fan incl. Blades, canopy etc. With 18" down rod(14SWG), Fork (10SWG), Heavy type insulator, 3/8th Inch bolt with nut, heavy type split pin etc.with safety wire & PS2 type capacitor, as directed by EIC. [Make: Orient/ Crompton/Usha (Safety Wire & S3/P2 Capacitor)]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. As per GS
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire as per GS
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991) As per GS
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supply & Delivery 230V, 50 HZ, 400 mm sweep full metal body, heavy duty AC wall bracket Fan (Orient/ Havells/EPC) complete with all accessories.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20PVC insulated flexible copper wire 0.5 mt. length
Supply and delivery of 230V 230mm (12"), 920 RPM Exhaust fan with all necessary accessories, as directed by EIC. [Make: EPC Heavy Duty, Usha, CG, Bajaj or equiv Make]
Supply and delivery of 230V 230mm (9") Exhaust fan with all necessary accessories, as directed by EIC. [Make: EPC Heavy Duty, Usha, CG, Bajaj or equiv Make]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: As per GS a)23 cm (9")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) Al. 23 cm (9") Exhaust fan
Al. 30 cm (12") Exhaust fan
COMPOUND LIGHTS:
Supply & delivery of 250V, 70W (Maximum) LED street light with IP-66, individual Secondary Optics Peanut Lens and Separate Toughned Glass Diffuser, Potted Driver to be used, 7000 lumen (minimum) output fittings, as directed by EIC. [Make: Havells/ Philips / Crompton]
Fixing only outdoor / street light after removing existing light with necessary items as per direction of EIC.
TIMERS:
S&F of 250V double door AC Timer DB [equivalent of 2+10 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCB ('C' curve 10KA), 1 no. 6-25A SP MCB ('C' curve 10kA), 1no. Programmable Digital time switch-24 hrs with minimum switching of 15 minutes and 1 no. 18A/25A 2-Pole power contractor with inner plate & 1 no. 25A Modular starter on outer plate and internal wiring by suitable size of Cu wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement, as directed by EIC.
SUPPLY & LAYING OF CABLES:
Supply & Delivery 1.1KV grade Al/XLPE/SWA/PVC cable as per choice of EIC. (Make - Polycab / Havells / RR Kabel / Gloster) 2C × 10 sqmm (for Compound Light)
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2C × 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2C × 10 sqmm
MISCELLANEOUS:
S&F of 6A, piano key type Switch
S&F of 20A Piano key type Switch
S&F of 5A, 5 pin Piano flush type Socket
S&F of 15A flushed type 3 pin Plug Socket
S&F of 6A Modular type Switch
S&F of 16A Modular type Switch
S&F of 6A Modular type 5 pin Plug Socket
S&F of 16A Modular type 3 pin Plug Socket
S&F of 6 module GI box
S&F of 2 row 12 module GI box
AC Timmer Repairing:
Supply & Fixing 240V, 25A, Modular type starter (Brand approved by EIC) on existing Timmer DB's door, after making necy. Position and connections with PVC Cu wire and earth continuity wire etc.
Supply & Change of Programmable Time Switch (L&T - 67DDT0)
S & Change of 25A 2-pole Power Contactor (L&T - AUMC2002501)
2.5 sqmm copper wire
Socketing for 2.5 sqmm copper wire
Fan Repairing:
Charges for Taken down the AC ceiling fan from it's original position and refixing the same at original position after overhauling and repairing.
Opening the fan part by part, testing, cleaning the fan blade & body by supplying cleaning materials and remove the dust from blade & body with satisfactorily. After cleaning the fans making the overhauling, varnishing, greasing the bearing and refitting & testing the same with satisfactory RPM.
Rewinding by supplying super enameled copper wire of appropriate gauge, mina lax paper, mica sheet, changing the loops, overhauling, backing, varnishing & refitting, testing and measuring the appropriate RPM.
Exhaust fan
Ceiling Fan
Supply & Changing of ball bearing:
i) TATA/SKF 6201
i) TATA/SKF 6202
Supply & Changing split pin
Supply & Changing 2.5 mfd fan condenser (TIBCON)
Supply & Changing Rubber insulator
Supply & Changing nuts bolt for hanging (3x3/8)"
Supply & Changing of fan Spindle/Fan shaft of mild steel, 12 to 17 mm dia and 6 to 8 inch long as required.
Supply & Changing of fan hanging clam of Fan as necy.
Supply & Changing of condenser carrier.
Painting of fan body, blades, down rod etc. by spray with suitable paint.
Carrying charge for fans from work site to CO.'s workshop & back to Site.
Repairing of Glow-sign/ Back-lead sign board:
Supply and Fixing of LED Batten 2 ft with Tube 12Watt, 230V AC, 50Hz, 6500K NW, THD<10%, bult in 2.5KV SPD with all accessories as directed by EIC. [Make: Philips/ Havells/Bajaj/CG/Wipro as per EIC]
Supply and fixing LED Batten 4 ft with Tube 22Watt, 230V AC, 50Hz, 6500K NW, THD<10%, bult in 2.5KV SPD with all accessories as directed by EIC. [Make: Philips/ Havells/Bajaj/CG/Wipro as per EIC]
Repairing of Back light Glow signage board by removing back side plate, dismentalling damaged lights & fixing new lights with necessary clip, screw, tie incl. internal wiring with of S&F 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed copper wire & cleaning the board.
S&F SMD LED inside the ACP board. Two run for each letter including wiring and proper SMPS fixing. The specification of the SMD is given below: a) LED – white, GE/Samsugn (Cat No. Tetra mini max, Code No. GEWHMMTS8) vin b) Type – straight, 3 No, Led per module c) Life – 70,000 burning hours. d) Visibility – 100 mtr, at least for normal eye e) Power supply-20 Amp. (GE/VIN) f) Power consumption – 1.5 watt per module g) Input – 230V, AC output 12V DC (Double LED layer)
S&F imported heavy duty 12V, DC 100VA SMPS power supply with properly with properly rated isolation transformer in suitable water proof enclosure to be fixed with signage frame for driving total LED system of the signage in adristribution manner for uniform load sharing in view of long run continuous use incl. necessary interconnection.
Removing & Refixing:
Removing of existing surface wiring and kept in suitable place as per guideline , given by dept. After civil work refixing of these wiring proper way incl S&F of PVC or MS saddle as required.
Removing of existing switch board , power board and computer board and kept in suitable place as per guideline , given by dept. After civil work refixing of these board proper way incl S&F of nuts bolts and washers as required.
Removing of existing SPN DB, TPN DB etc and kept in suitable place as per guideline , given by dept. After civil work refixing of these DB proper way incl necy. Nuts bolts and iron frame.
SITC of :- 1250 VA Inverter ( Min):
SITC of 1250VA/12V Pure Sine Wave Inverter, 200Ah Battery with All in One Plastic Container Trolley (AIO Trolley) Support Single/Double/Jumbo/Flat Plate/Tall Tubular Battery)1 Inverter , 1Battery, User Manual, Float Indicator, Petroleum Jelly, Nut Bolt Set. INPUT *Input Voltage: 230V,5% tolarence *Operating Frequency :50 Hz (autosensing) Inverter Details- Type: Pure Sine wave inverter; VA Rating: 1250VA/12V Peak Load :- 1050W Battery Details- Capacity: 200Ah/12V; Futuristic Design using Leak Proof PPCP to ensure durability and zero electrolyte leakage; water level indicators: 6 (Make:- Microtek/Exide/Luminous)
Battery Protection: Intelligent battery management features to prolong battery life. It prevents overcharging, deep discharge, and other potential issues that can damage the battery.It can be add more batteries to increase your backup capacity without needing to replace the entire system. Flat 3 years warranty on Inverter and Battery
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
ELECTROMAX (BID ID -6491359)
JANA ELECTRICALS (BID ID -6497854)
PUSPA ELECTRIC (BID ID -6512644)
G.G. PROJECT (BID ID -6511427)
BIKASH ENTERPRISE (BID ID -6516261)
MAHESWAR ELECTRICAL INDUSTRIES (BID ID -6495675)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .