Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC 127 GYAN LOK DEFENCE COLONY ROORKEE DISTT HARIDWAR UK PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹11.8 L Quoted ₹12.1 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹13.1 L+₹1.0 L (8.59%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | ₹13.1 L+₹1.0 L (8.59%) | L2 | Rejected-Finance Being Not Lowest |
| 3 | L3₹13.9 L+₹1.8 L (14.6%)Rejected-Finance | ₹13.9 L+₹1.8 L (14.6%) | L3 | Rejected-Finance Being Not Lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical No, as per WLR CECC QE Sep 2021 |
| 5 | Rejected-Technical | - | - | Rejected-Technical documents not submitted as per un-enlisted contractor criteria as per NIT |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
11 Mar 2022, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR/MAINT OF LT PANELS, LT UG CABLES AND OTHER WORKS AT LANSDOWNE UNDER AGE (I) LANSDOWNE
2021_MES_478927_4
8649/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
Class E Cat b i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹19,600
26 Mar 2022
25 Feb 2022
14 Mar 2022
25 Feb 2022
11 Mar 2022
27 Feb 2022
Amount
Disconnecting, dismantling and taking out of unsv capacitors bank and S&F new cylindrical type capacitor bank in existing APFC panel of capacity 30 KVAR, 3 phase, 440Volt, 50 HZ complete incl making all necessary connections and cutting chasing if required in existing APFC panel incl testing complete all as specified and directed.
Disconnecting, dismantling and taking out of unsv analog type ammeter for LT Panel box and supply and fixing new three phase ampere meter digital type including CT of range (0-500), amp of size 96x96mm for LT including necessary control wire connection and necessary thimbles nut bolts etc testing incl cutting if required in existing LT panel complete all as directed.
Disconnecting, dismantling and taking out of unsv analog type voltmeter for LT Panel box and supply and fixing new three phase volt meter digital type including PT of range (0-500V), of size 96x96mm for LT including necessary control wire connection and necessary thimbles nut bolts etc testing incl cutting if required in existing LT panel complete all as directed.
Disconnecting, dismantling and taking out of unserviceable indicator lamp assemble LED type from LT panel and supply and fixing new indicator lamp assemble LED type RYB including making connections with 2.5sqmm copper conductor single core PVC insualted cable and necessary thimbles nut bolts etc incl cutting the slot if required in existing LT Panel complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 25 x4 bles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
M&L for tinkaning, welding, denting/painting to damage door and MS Iron framework, including hinges of door, nuts, bolts, washers, welding , bending cold and hot drillling hole for bolts , in any size as directed and inclusive of one primer coat of red oxide primer one under coat and one finishing coat of paint with existing colour and having letter writing (required instruction) in white/Red paint, complete and taking out to existing old U/S MCCBs, Bus bar from LT Panel carefully and replacement with new one aluminium lugs to incoming and outgoing LT cable, complete servicing testing and commissioning in all respect all as directed.
M&L for replacement of burnt copper bus bar of rating 200 A to 600A on LT panels of size 8.00mm thick and 45mm width with proper color coding as directed after unmounting all switchgears and refixing the same after replacement of busbars complete all as specified and directed
S&F in replacement of MCCB 4 pole, 415 volt , adjustable type 250 Amp breaking capacity 36 KA complete all as specified and directed. Make : ABB/Siemens/Schneider/Havells
S&F in replacement of MCCB 4 pole, 415 volt , adjustable type 200 Amp breaking capacity 36 KA complete all as specified and directed. Make : ABB/Siemens/Schneider/Havells
S&F in replacement of MCCB 4 pole, 415 volt , adjustable type 160 Amp breaking capacity 36 KA complete all as specified and directed. Make : ABB/Siemens/Schneider/Havells
S&F in replacement of MCCB 4 pole, 415 volt , adjustable type 100 Amp breaking capacity 25 KA complete all as specified and directed. Make : ABB/Siemens/Schneider/Havells
S&F in replacement of MCCB 4 pole, 415 volt , adjustable type 63 Amp breaking capacity 25 KA complete all as specified and directed. Make : ABB/Siemens/Schneider/Havells
Supply and straing in replacement of over head ACSR conductor any size i.e weasel, Ferret and Dog and any type including binding/jointing the conductor to insulator with binding wire complete all as specified and directed.
M&L in replacement for galvanized steel wire 3.15mm or 4mm dia continous eath wire on pole or guard wire for protecting fallen overhead conductor including binding wire of suitable size complete all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed.
Supply & fixing in replacement pin type porcelain, vitreous, white/brown insulator including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut, 100mm height 65mm dia, 1100V grade complete all as specified and directed by Engr-in-Charge.
S&F in replacement of steel tubular swaged poles complete as per IS-2713 MS base plate of size 300mmx300mmx6mm , final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 mtr long) including necessary earth work and excavation, PCC in foundation 1:4:8 type D-2, using 40 mm graded stone aggregate and PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting two coats of aluminium paint over one coat of red oxide primer including 5 Nos band/straps with yellow and black colour in alternatete way (250mm wide each) synthetic enamelled paint two coat at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed.
M&L for prepration of old treated surface of existing steel tubular poles 8/9 mtr long( upto 1.20 mtr from coping/ground level (whichever is on upper side) but incl brackets, clamp cross arms etc with two coat of aluminium paint over one coat of red oxide primer incl writing MES No complete as specified and directed.
M&L for refixing of poles in same poles or other place as directed after taking out pole from earth, incl transportation if required and refixing the same place or other place as directed incl necessary earth work, coping and fixing of existing over head conductor complete all as specified and directed.
Dismantling stay assembly complete all as specified and as directed.
Supply & fixing in eplacement of stay assembly complete with all accessories, such as stay plate 300x300x6mm, stay rod 215cm long and 16mm dia with nuts including GI Bow turn buckle etc, all as per Electrical Plate No 1 SSR-2009 Part-I complete all as specified and as directed.
M&L in replacement for loop type insulators vitreous porcelain white, brown or green large size with overall dimensions 90x140 mm clearance of hole 25.5mm complete.
M&L for cross arms,bracings,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers welding,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including of one primer coat,one under coat and one finishing coat and one finishing coat of paint.complete all as specified and directed.
Taking down of old U/S service cable and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, twin core cable flat or circular 10 Sqmm complete all as specified and directed.
Disconnecting the unservicable under ground cable, taking out the same and supplying, laying, commissioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured stranded aluminium conductor LT UG cable (Conforming to IS 1554) in trenches/ducts/through GI Pipes under roads of size 16 Sqmm 4 Core complete all as specifed and directed. Note : The earth work, GI pipe shall be measured and paid separately under appropriate item of Sch A
All as per Item No 27 here in above but Cable of size 25 Sqmm 3.5 Core complete all as specified and directed.
All as per Item No 27 here in before but Cable of size 50 Sqmm 3.5 Core complete all as specified and directed.
All as per Item No 27 here in befire but Cable of size 70Sqmm 3.5 Core complete all as specified and directed.
All as per Item No 27 here in before but Cable of size 120 Sqmm 3.5 Core complete all as specified and directed.
All as per Item No 27 here in before but Cable of size 185 Sqmm 3.5 Core complete all as specified and directed.
Supply and fix in replacement of cable jointing kit(straight through) for 1.1 KV grade cable complete with jointing material heat shrink type and acessories suitable for 3.5/4 core core XLPE, armoured. AI conductor cable of size 16 to 50 Sqmm, Indoor/Outdoor type complete all as specified and directed.
Supply and fix in replacement cable jointing kit (Straight through) for 1.1 KV grade cable complete with jointing material heat shrink type and acessories suitable for 3.5/4 core core XLPE, armoured. AI conductor cable of size 70 to 185 Sqmm, Indoor/Outdoor type complete all as specified and directed.
Excavation in trenches in soft/disintegrated soil not exc 1.5mtr wide and not exc. 1.5mtr depth for laying of UG Cable/foundation etc complete all as specified and directed
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n exc 25cm each layer complte all as pecified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed by Engg-in-Charge. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
M&L for cable protection bricks common burnt clay sub class B designation 75 for protectioon of UG Cable laid in trenches complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (Using 40mm graded stone aggregte) as in mass concrete/foundation complete all as specified and directed.
M&L for PCC 1:4:8, type D2, (using 40mm stone aggregate) in pole foundation bed complete all as specified as direccted
M&L for PCC 1:2:4, type B1 (using 20mm stone aggregate) in pole coping complete all as specified as direccted
Disconnecting and taking out old unserviceable GI Pipe and supplying, laying & jointing GI Water tubing 80mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed.
Disconnecting and taking out old unserviceable GI Pipe and supplying, laying & jointing GI Water tubing 50mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed.
Bhardwaj Construction Co
CHAUDHARY FURNITURE HOUSE
Bidder Name
Shikha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .